Autoencoder Based Analysis of RF Parameters in the Fermilab Low Energy Linac

Machine learning (ML) has the potential for significant impact on the modeling, operation, and control of particle accelerators due to its ability to model nonlinear behavior, interpolate on complicated surfaces, and adapt to system changes over time. Anomaly detection in particular has been highlighted as an area where ML can significantly impact the operation of accelerators. These algorithms work by identifying subtle behaviors of key variables prior to negative events. Efforts to apply ML to anomaly detection have largely focused on subsystems such as RF cavities, superconducting magnets, and losses in rings. However, dedicated efforts to understand how to apply ML for anomaly detection in linear accelerators have been limited. In this paper the use of autoencoders is explored to identify anomalous behavior in measured data from the Fermilab low-energy linear accelerator.

Edelen, Jonathan P. (ORCID:0000000215180652)↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗

Mechanisms of superconductivity investigated by nuclear radiation

Investigation focused on the behavior of superconducting magnet and its constituent materials during and after exposure to nuclear radiation. The results will indicate the feasibility of their use in diverse applications and various environments.

Autler, S. H.↗

The internal Compton effect

Internal Compton effect, and use of superconducting magnet spectrometer to determine multipolarity assignments

MAGNET↗

36 GHz travelling wave maser.

Traveling wave maser with 6 db amplification at 36 GHz, using Cr ion doped rutile as active material and superconducting magnet for DC magnetic field

Hagen, J. P.↗

Low temperature uses of helium

Helium is used for purging and pressurizing cryogenic rocket propellants, welding, atmosphere control, leak detection, and refrigeration. It provides the lowest possible liquid-bath temperature and produces superconductivity in certain materials. Its superfluid effects are used in superconducting magnets.

Brown, G. V.↗

Multiwire proportional counter development

A test run was made at the Bevatron to check the character of signals induced in an electromagnetic delay line capacitively coupled to the wire cathode plane of a multiwire proportional chamber. In particular, these signals and the behavior of the readout electronics as a function of associated delta-ray production are studied. These measurements are important in assessing the effect of delta-ray background on the spatial resolution attainable for the primary ions. Test results are used to design a multiwire proportional chamber and readout system for use as spatial detectors in a superconducting magnetic spectrometer experiment.

Source record↗

Search for antimatter in primary cosmic rays.

Data from two flights of a new superconducting magnetic spectrometer are reported. This instrument was capable of a direct matter-antimatter separation in the cosmic rays. Antimatter events would appear in the spectrometer as trajectories which curve in the opposite direction to common matter, because of their negative charge. A brief description of the equipment and of the characteristics of the instrument is presented, along with the data processing techniques used. A new upper limit on the amount of antimatter in primary cosmic rays has been established. The limits are considerably lower than those for any previous experiment.

Buffington, A.↗

Hot ion plasma heating experiments in SUMMA

Initial results are presented for the hot-ion plasma heating experiments conducted in the new SUMMA (superconducting magnetic mirror apparatus) at NASA Lewis Research Center. A discharge is formed by applying a radially inward dc electric field between cylindrical anodes and hallow cathodes located at the peak of the mirrors. Data were obtained at midplane magnetic field strengths from 1.0 to 3.5 tesla. Charge-exchange neutral particle energy analyzer data were reduced to ion temperatures using a plasma model that included a Maxwellian energy distribution superimposed on an azimuthal drift, finite ion orbits, and radial variations in density and electric field. The best ion temperatures in a helium plasma were 5 keV and in hydrogen the H2(+) and H(+) ions were 1.2 keV and 1 keV respectively. Optical spectroscopy line broadening measurements yielded ion temperatures about 50 percent higher than the charge-exchange neutral particle analyzer results. Spectroscopically obtained electron temperature ranged from 3 to 30 eV. Ion temperature was found to scale roughly linearly with the ratio of power input-to-magnetic field strength, P/B.

Reinmann, J. J.↗

Search for antinuclei in the primary cosmic rays

Results of a search for primary cosmic-ray antinuclei with charges 2 less than or equal to Z less than or equal to 26 with rigidities above 5 GV/c using a second-generation superconducting magnetic spectrometer with an average bending power of 5.1 kG-m. The addition of new data doubles the sample of cosmic-ray nuclei previously reported and greatly increases the percentage of the more highly charged nuclei.

Smoot, G. F.↗

Hot ion plasma heating experiments in SUMMA

A new superconducting magnetic mirror apparatus (SUMMA) is described using photographs, diagrams, characteristics graphs, and block diagrams. The apparatus consists of a magnet facility, a plasma test section, the electrode assembly, a charge-exchange neutral particle analyzer, and apparatus for emission spectroscopy. Initial results of hot ion plasma heating experiments conducted in this facility are reported. The purpose of these experiments was twofold: (1) to make a reliable electrode assembly for steady-state operation in the new SUMMA magnetic field configuration and test-section geometry; and (2) to see how ion heating scales as the midplane magnetic field is varied up to 3.5 tesla.

Reinmann, J. J.↗

Low-noise K(u)-band receiver input system

Improved maser and superconducting magnet, which operates in vacuum of closed-cycle helium refrigerator, comprise a low-noise, reliable, field-operational receiver input system.