Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Sample mount for electron backscatter diffraction

A sample mount having a bottom surface, a front surface, and a second portion is disclosed. The first portion is perpendicular to the bottom surface. The second portion has an external surface and an internal surface and extends from the first portion to form a 70-degree angle relative to the bottom surface. The sample mount may also have a top surface, an opening extending through the second portion of the front surface, and a receiving area configured to receive a sample, wherein the top surface presents an unimpeded path between the sample and an SEM pole piece. The sample mount may include a spring-loaded handle configured to push the sample against the internal surface of the second portion of the front surface, wherein pushing the sample against the internal surface places the sample at the 70-degree angle relative to the bottom surface.

Wieliczka, David M.↗

Sample rotating turntable kit for infrared spectrometers

An infrared spectrometer sample rotating turntable kit has a rotatable sample cup containing the sample. The infrared spectrometer has an infrared spectrometer probe for analyzing the sample and the rotatable sample cup is adapted to receive the infrared spectrometer probe. A reflectance standard is located in the rotatable sample cup. A sleeve is positioned proximate the sample cup and adapted to receive the probe. A rotator rotates the rotatable sample cup. A battery is connected to the rotator.

47 OTHER INSTRUMENTATION↗

Measurements of NaI(Tl) electron response: comparison of different samples

This paper measures the sample to sample variation in the light yield proportionality of NaI(Tl), and so explores whether this is an invariant characteristic of the material or whether it depends on the chemical and physical properties of the tested samples. We report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. We observe that while samples produced by the same manufacturer at approximately the same time have virtually identical electron response curves, there are significant sample to sample variations among crystals produced by different manufacturers or at different times. In an effort to correlate changes in the electron response with details of the scintillation mechanism, we characterized other scintillation properties, including the gamma response and the x-ray excited emission spectra and decay times, for the nine crystals. While sample to sample differences in these crystals were observed, we have been unable to identify the underlying fundamental mechanisms that are responsible for these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double superconducting transition in the filled skutterudite PrOs4Sb12 and sample characterizations

Through the characterization of many samples of the filled skutterudite compound PrOs4Sb12, we found that even though the double superconducting transition in the specific heat (Tc1 {approx}1.89 K and Tc2 {approx} 1.72 K) appears in samples of good quality, there are various pieces of evidence that cast doubt on its intrinsic nature. First, three samples exhibit a single sharp transition of {approx}15 mK width at Tc{approx}1.7 K. The quality of the samples exhibiting a single transition is clearly better; the width of the transition is smallest and the normalized specific heat jump ((C-Cnormal)/Cnormal)Tc is larger than the sum of the two specific heat jumps when a double transition exists. Second, the ratio of the two specific heat jumps Delta C(Tc1)/Delta C(Tc2) exhibits a wide variation with samples not only among different batches but also even within a batch. Finally, this ratio was strongly reduced by polishing a sample down to {approx}100 {micro}m, which points to bulk inhomogeneities as an origin of the spurious transition. Our x-ray diffraction analysis points to Pr-vacancy problem in the samples, but it does not show that they are the origin of the double transition. We provide the superconducting phase diagram under magnetic field of a sample exhibiting a single transition and fit the curve Hc2(T) with a two-band model taking into account the appropriate values for the gap as deduced from thermal conductivity measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bounds on the sample complexity for private learning and private data release

Learning is a task that generalizes many of the analyses that are applied to collections of data, and in particular, collections of sensitive individual information. Hence, it is natural to ask what can be learned while preserving individual privacy. [Kasiviswanathan, Lee, Nissim, Raskhodnikova, and Smith; FOCS 2008] initiated such a discussion. They formalized the notion of private learning, as a combination of PAC learning and differential privacy, and investigated what concept classes can be learned privately. Somewhat surprisingly, they showed that, ignoring time complexity, every PAC learning task could be performed privately with polynomially many samples, and in many natural cases this could even be done in polynomial time. While these results seem to equate non-private and private learning, there is still a significant gap: the sample complexity of (non-private) PAC learning is crisply characterized in terms of the VC-dimension of the concept class, whereas this relationship is lost in the constructions of private learners, which exhibit, generally, a higher sample complexity. Looking into this gap, we examine several private learning tasks and give tight bounds on their sample complexity. In particular, we show strong separations between sample complexities of proper and improper private learners (such separation does not exist for non-private learners), and between sample complexities of efficient and inefficient proper private learners. Our results show that VC-dimension is not the right measure for characterizing the sample complexity of proper private learning. We also examine the task of private data release (as initiated by [Blum, Ligett, and Roth; STOC 2008]), and give new lower bounds on the sample complexity. Our results show that the logarithmic dependence on size of the instance space is essential for private data release.

99 GENERAL AND MISCELLANEOUS↗

Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self-absorption effects. The microscopy analysis compares different filter loadings and shows that smaller particle sizes (under 10 micron) can readily be seen on the more lightly loaded filters. At higher loadings, however, the particle size is harder to differentiate. This study provides data on actual stack emission samples showing a range of mass loading conditions and visual evidence of particle size and distribution and also presents the difficulties in quantifying self-absorption effects using actual samples.

air sampling↗

Enhanced Sampling and Analysis, Selection of Technology for Testing

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. This report details the progress made in the first half of FY 2010 and includes a further consideration of the research focus and goals for this year. Our sampling options and focus for the next generation sampling method are presented along with the criteria used for choosing our path forward. We have decided to pursue the option of evaluating the feasibility of microcapillary based chips to remotely collect, transfer, track and supply microliters of sample solutions to analytical equipment in support of aqueous processes for used nuclear fuel cycles. Microchip vendors have been screened and a choice made for the development of a suitable microchip design followed by production of samples for evaluation by ANL, LANL, and INL on an independent basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

An asixymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples

Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an axisymmetric diffusion experiment coupled with tracer profiling may be a promising approach to estimate of diffusion anisotropy of sedimentary rocks.

54 ENVIRONMENTAL SCIENCES↗

Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Humidity-controlled preparation of frozen-hydrated biological samples for cryogenic coherent x-ray diffraction microscopy

Coherent x-ray diffraction microscopy (CXDM) has the potential to visualize the structures of micro- to sub-micrometer-sized biological particles, such as cells and organelles, at high resolution. Toward advancing structural studies on the functional states of such particles, here, we developed a system for the preparation of frozen-hydrated biological samples for cryogenic CXDM experiments. The system, which comprised a moist air generator, microscope, micro-injector mounted on a micromanipulator, custom-made sample preparation chamber, and flash-cooling device, allowed for the manipulation of sample particles in the relative humidity range of 20%-94%rh at 293 K to maintain their hydrated and functional states. Here, we report the details of the system and the operation procedure, including its application to the preparation of a frozen-hydrated chloroplast sample. Sample quality was evaluated through a cryogenic CXDM experiment conducted at BL29XUL of SPring-8. Taking the performance of the system and the quality of the sample, the system was suitable to prepare frozen-hydrated biological samples for cryogenic CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements

We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{sub 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Surface Water FTICR-MS, NPOC, TN, Anions, Stable Isotopes, Bacterial Abundance, and Dissolved Inorganic Carbon (v8)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the surface water samples and does not include any results from the sediment. Sediment data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1729719. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in March 2020. It was updated in October 2020 (v2, new and modified files), July 2021 (v3, new and modified files), January 2023 (v4, new and modified files), February 2023 (v5, new and modified files), August 2023 (v6, new and modified files), July 2025 (v7,new and modified files), and August 2026 (v8, new and modified files). Version 8 includes major restructuring of the files and their formats. See the change history section in readme for more details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, and (9) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods, (2) dissolved inorganic carbon (DIC), (3) stable water isotopes (O and H), (4) specific conductivity, (5) total dissolved nitrogen (TN), (6) anions, (7) flow cytometry bacterial abundance data, (8) laboratory methods, and (9) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL, https://www.pnnl.gov/environmental-molecular-sciences-laboratory), and (12) a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .html, .jpg, or .jpeg.

18-O↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Sediment FTICR-MS, Dissolved Organic Carbon, Aerobic Respiration, Elemental Composition, Grain Size, Total Nitrogen and Organic Carbon Content, Bacterial Abundance, and Stable Isotopes (v10)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the sediment samples and does not include any results from the surface water. Surface water data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1603775. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in December 2020. It was updated in April 2021 (v2; modified files), May 2022 (v3; new and modified files), November 2022 (v4; new and modified files), January 2023 (v5 and v6; new and modified files), February 2023 (v7; new and modified files), August 2023 (v8; new and modified files), July 2025 (v9; new and modified files), and June 2026 (v10; new and modified files). Version 10 includes major restructuring of the files and their formats. See the change history in the readme for details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, (9) a folder of site photos, and (10) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods; (2) respiration rates and normalized respiration rates calculated from laboratory sediment incubations, (3) X-ray fluorescence (XRF) elemental composition, (4) grain size distribution from the < 2 millimeter fraction of sediment, (5) total organic carbon and total nitrogen content, (6) bacterial abundance flow cytometry data, (7) sediment stable isotopes (C and N), (8) laboratory methods, (9) water and sediment mass and volume used in incubations, (10) a folder with code, inputs, and plots for the respiration rates, (11) a folder containing XRF data, (12) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory), (12) and a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .jpg, or .jpeg.

13C↗

Spatial Study 2022: Surface Water Samples, Cotton Strip Degradation, and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. The dataset provides data and photos generated from sample collection during the same one-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. The contents include surface water geochemistry data; river substrate grain size photos; stream depth data; manual chamber open channel respiration data; and field metadata (including qualitative information on instream and river corridor characteristics). Grain size photos can be used to improve estimates of channel substrate D50 data. The dataset also includes tensile strength and photos from cotton strip field degradation experiments; five-week sensor time series temperature, dissolved oxygen, pressure, pH, specific conductance, chlorophyll A, and turbidity data; plots of the sensor data; and R scripts used to generate the plots. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. SSS data published in the CM data package were not included in this data package. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Additionally, sensor data from a similar 2021 spatial study can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1892052 and 2021 sample data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1898914. The 2021 spatial study had some sites in common with this 2022 spatial study. This dataset is comprised of three photo folders and one main data folder with six subfolders. The photo folders contain photographs and videos of cotton strip retrieval and sediment quadrats. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) total suspended solids (TSS) data and cotton strip tensile strength data and averages; (5) field protocol; (6) readme; (7) methods codes; (8) international generic sample number (IGSN) mapping file; (9) sensor installation methods summary; (10) stream depth and averages; and (11) Ultrameter data and averages. The Sonar subfolder consists of Sonar time-series depth data and a processing script. The BarotrollAtm, DepthHOBO, MantaRiver, miniDOT, and miniDOTManualChamber subfolders contain time-series data, plots, and summary files. All files are .csv, .pdf, .txt, .R, .Rmd, .jpg, .jpeg, .AVI, .mp4, or .mov. The data package was originally published in April 2023. It was updated in August 2023 (v2; modified files) and September 2024 (v3; modified files). See the change history section in the readme for details. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗