Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models

The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.

Jones, William T.↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Sensitivity of C-Band Polarimetric Radar-Based Drop Size Distribution Measurements to Maximum Diameter Assumptions

The estimation of rain drop size distribution (DSD) parameters from polarimetric radar observations is accomplished by first establishing a relationship between differential reflectivity (Z(sub dr)) and the central tendency of the rain DSD such as the median volume diameter (D0). Since Z(sub dr) does not provide a direct measurement of DSD central tendency, the relationship is typically derived empirically from rain drop and radar scattering models (e.g., D0 = F[Z (sub dr)] ). Past studies have explored the general sensitivity of these models to temperature, radar wavelength, the drop shape vs. size relation, and DSD variability. Much progress has been made in recent years in measuring the drop shape and DSD variability using surface-based disdrometers, such as the 2D Video disdrometer (2DVD), and documenting their impact on polarimetric radar techniques. In addition to measuring drop shape, another advantage of the 2DVD over earlier impact type disdrometers is its ability to resolve drop diameters in excess of 5 mm. Despite this improvement, the sampling limitations of a disdrometer, including the 2DVD, make it very difficult to adequately measure the maximum drop diameter (D(sub max)) present in a typical radar resolution volume. As a result, D(sub max) must still be assumed in the drop and radar models from which D0 = F[Z(sub dr)] is derived. Since scattering resonance at C-band wavelengths begins to occur in drop diameters larger than about 5 mm, modeled C-band radar parameters, particularly Z(sub dr), can be sensitive to D(sub max) assumptions. In past C-band radar studies, a variety of D(sub max) assumptions have been made, including the actual disdrometer estimate of D(sub max) during a typical sampling period (e.g., 1-3 minutes), D(sub max) = C (where C is constant at values from 5 to 8 mm), and D(sub max) = M*D0 (where the constant multiple, M, is fixed at values ranging from 2.5 to 3.5). The overall objective of this NASA Global Precipitation Measurement Mission (GPM/PMM Science Team)-funded study is to document the sensitivity of DSD measurements, including estimates of D0, from C-band Z(sub dr) and reflectivity to this range of D(sub max) assumptions. For this study, GPM Ground Validation 2DVD's were operated under the scanning domain of the UAHuntsville ARMOR C-band dual-polarimetric radar. Approximately 7500 minutes of DSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSD's were then used as input to a T-matrix model for computation of polarimetric radar moments at C-band. All necessary model parameterizations, such as temperature, drop shape, and drop fall mode, were fixed at typically accepted values while the D(sub max) assumption was allowed to vary in sensitivity tests. By hypothesizing a DSD model with D(sub max) (fit) from which the empirical fit to D0 = F[Z(sub dr)] was derived via non-linear least squares regression and a separate reference DSD model with D(sub max) (truth), bias and standard error in D0 retrievals were estimated in the presence of Z(sub dr) measurement error and hypothesized mismatch in D(sub max) assumptions. Although the normalized standard error for D0 = F[Z(sub dr)r] can increase slightly (as much as from 11% to 16% for all 7500 DSDs) when the D(sub max) (fit) does not match D(sub max) (truth), the primary impact of uncertainty in D(sub max) is a potential increase in normalized bias error in D0 (from 0% to as much as 10% over all 7500 DSDs, depending on the extent of the mismatch between D(sub max) (fit) and D(sub max) (truth)). For DSDs characterized by large Z(sub dr) (Z(sub dr) > 1.5 to 2.0 dB), the normalized bias error for D0 estimation at C-band is sometimes unacceptably large (> 10%), again depending on the extent of the hypothesized D(sub max) mismatch. Modeled errors in D0 retrievals from Z(sub dr) at C-band are demonstrated in detail and comparedo similar modeled retrieval errors at S-band and X-band where the sensitivity to D(sub max) is expected to be less. The impact of D(sub max) assumptions to the retrieval of other DSD parameters such as Nw, the liquid water content normalized intercept parameter, are also explored. Likely implications for DSD retrievals using C-band polarimetric radar for GPM are assessed by considering current community knowledge regarding D(sub max) and quantifying the statistical distribution of Z(sub dr) from ARMOR over a large variety of meteorological conditions. Based on these results and the prevalence of C-band polarimetric radars worldwide, a call for more emphasis on constraining our observational estimate of D(sub max) within a typical radar resolution volume is made

Carey, Lawrence D.↗

Sensitivity of Downward Longwave Surface Radiation to Moisture and Cloud Changes in a High-elevation Region

Several studies have suggested enhanced rates of warming in high-elevation regions since the latter half of the twentieth century. One of the potential reasons why enhanced rates of warming might occur at high elevations is the nonlinear relationship between downward longwave radiation (DLR) and specific humidity (q). Using ground-based observations at a high-elevation site in southwestern Colorado and coincident satellite-borne cloud retrievals, the sensitivity of DLR to changes in q and cloud properties is examined and quantified using a neural network method. It is also used to explore how the sensitivity of DLR to q (dDLR/dq) is affected by cloud properties. When binned by season, dDLR/dq is maximum in winter and minimum in summer for both clear and cloudy skies. However, the cloudy-sky sensitivities are smaller, primarily because (1) for both clear and cloudy skies dDLR/dq is proportional to 1/q, for q>0.5 g/kg, and (2) the seasonal values of q are on average larger in the cloudy-sky cases than in clear-sky cases. For a given value of q, dDLR/dq is slightly reduced in the presence of clouds and this reduction increases as q increases. In addition, DLR is found to be more sensitive to changes in cloud fraction when cloud fraction is large. In the limit of overcast skies, DLR sensitivity to optical thickness decreases as clouds become more opaque. These results are based on only one high-elevation site, so the conclusions here need to be tested at other high-elevation locations.

cloud physics↗

Natural Ocean Carbon Cycle Sensitivity to Parameterizations of the Recycling in a Climate Model

Sensitivities of the oceanic biological pump within the GISS (Goddard Institute for Space Studies ) climate modeling system are explored here. Results are presented from twin control simulations of the air-sea CO2 gas exchange using two different ocean models coupled to the same atmosphere. The two ocean models (Russell ocean model and Hybrid Coordinate Ocean Model, HYCOM) use different vertical coordinate systems, and therefore different representations of column physics. Both variants of the GISS climate model are coupled to the same ocean biogeochemistry module (the NASA Ocean Biogeochemistry Model, NOBM), which computes prognostic distributions for biotic and abiotic fields that influence the air-sea flux of CO2 and the deep ocean carbon transport and storage. In particular, the model differences due to remineralization rate changes are compared to differences attributed to physical processes modeled differently in the two ocean models such as ventilation, mixing, eddy stirring and vertical advection. GISSEH(GISSER) is found to underestimate mixed layer depth compared to observations by about 55% (10 %) in the Southern Ocean and overestimate it by about 17% (underestimate by 2%) in the northern high latitudes. Everywhere else in the global ocean, the two models underestimate the surface mixing by about 12-34 %, which prevents deep nutrients from reaching the surface and promoting primary production there. Consequently, carbon export is reduced because of reduced production at the surface. Furthermore, carbon export is particularly sensitive to remineralization rate changes in the frontal regions of the subtropical gyres and at the Equator and this sensitivity in the model is much higher than the sensitivity to physical processes such as vertical mixing, vertical advection and mesoscale eddy transport. At depth, GISSER, which has a significant warm bias, remineralizes nutrients and carbon faster thereby producing more nutrients and carbon at depth, which eventually resurfaces with the global thermohaline circulation especially in the Southern Ocean. Because of the reduced primary production and carbon export in GISSEH compared to GISSER, the biological pump efficiency, i.e., the ratio of primary production and carbon export at 75 m, is half in the GISSEH of that in GISSER, The Southern Ocean emerges as a key region where the CO2 flux is as sensitive to biological parameterizations as it is to physical parameterizations. The fidelity of ocean mixing in the Southern Ocean compared to observations is shown to be a good indicator of the magnitude of the biological pump efficiency regardless of physical model choice.

Antarctic Ocean↗

How Well Satellite Remote Sensing Can Inform Surface Level Ozone Production Sensitivity to Precursor Trace Gas Emissions?

Surface-level ozone (O3) pollution mitigation strategies rely on a clear understanding of the atmospheric chemical processes involving O3, NOx (nitric oxide (NO) + nitrogen dioxide (NO2)) and volatile organic compounds (VOCs). A robust spatiotemporal classification of O3 photochemical regimes with relative chemical sensitivity of local O3 formation to emission reductions of NOx (NOx-limited regime) versus VOCs (radical-limited regime) is required to design anthropogenic emission reduction policies in order to improve surface air quality. Numerous studies found that the ratio of satellite-retrieved Vertical Column Densities (VCDs) of formaldehyde (HCHO) to NO2 can diagnose O3 production sensitivity. However, uncertainty still remains about the accuracy of such estimates using satellite-based retrievals. This study conducts an investigation to identify how well satellite data can inform surface-level O3 sensitivity by validating satellite-based estimates against aircraft-based retrievals taken during the Long Island Sound Tropospheric Ozone Study (LISTOS-2018) and Ozone Water-Land Environmental Transition Study (OWLETS-2) field campaigns. For this study, we use HCHO and NO2 retrievals from the Ozone Monitoring Instrument (OMI) onboard the Aura satellite, and high spatiotemporal resolution TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite. The Community Multiscale Air Quality (CMAQ) modelling system is used to provide trace gas vertical profiles to recalculate air mass factor for deriving consistent satellite-based VCDs. To demonstrate the ability of satellites to diagnose O3 production regimes, we validate satellite-derived O3 sensitivity regimes, along with the OMI and TROPOMI products applied, using HCHO and NO2 retrievals from the aircraft-based instruments: Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) spectrometer and Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) instruments deployed during the LISTOS-2018 and OWLETS-2 campaigns. The results of this work will advance our fundamental knowledge of the spatiotemporal evolution of the complex O3-NOx-VOC chemistry, and will advance our understanding about the quality of remote-sensing, suborbital, and satellite data for accurately observing surface-level O3 production sensitivity.

Satellite↗

Genomic and Phenotypic Associations to Predict Human Sensitivity to SpaceRadiation

High-linear energy transfer (LET) ionizing radiation is a major health hazard for astronauts who will be exposed to galactic cosmic rays during upcoming lunar and Mars missions. Predicting and mitigating this risk requires understanding the factors underlying individual radiation sensitivity. We started to address this challenge by identifying the genomic and phenotypic associations with sensitivity to low and high-LET ionizing radiation ex vivo in over 750 healthy human donors. We exposed primary human blood mononuclear cells to simulated galactic cosmic ray components: 350MeV/n 28Si, 350MeV/n 40Ar and 600MeV/n 56Fe particles, at 1.1 and 3 particles/100 sq.m fluences, as well as 0.1 Gy and 1 Gy doses of gamma rays, and analyzed the outcomes at 4 and 24 hours post-irradiation. We quantified DNA damage and repair responses based on 53BP1+ radiation-induced foci formation, together with oxidative stress and changes in secreted factors including immune cytokines and exosomes. We also analyzed phenotypic associations with spontaneous DNA repair foci at baseline prior to irradiation. We identified an increase in spontaneous DNA repair associated with age and latent viral infection, and observed that human spontaneous DNA repair foci at baseline can serve as a negative predictor of DNA repair and immunoregulatory cytokine production after irradiation. Furthermore, we observed a wide variability of subject- and LET-dependent radiation responses, with radiation-induced DNA repair foci increasing by dose and LET, and high-LET particle radiation resulting in more residual DNA damage compared to low-LET particles and gamma rays. We have developed multiple metrics to quantify human radio sensitivity across the spectrum of conditions. Here we present their dependence on radiation quality and phenotypic variables, including an age-dependent decrease in DNA repair after irradiation, and genomic associations with radio sensitivity based on low-coverage whole genome sequencing. We anticipate that our work will pave the way for understanding the spectrum of human radio sensitivity and identifying targets for countermeasure development to reduce DNA and cellular damage and radiation carcinogenesis during deep space exploration.

GWAS radiation human↗

Holey Silicon-based Thermopiles for High-Sensitivity Broadband Thermal Detection in Space

Future planetary missions call for thermal detectors with high sensitivity over a wide range of temperature or wavelength. Conventional approaches based upon photon detectors are limited to a narrow and material-selective range of wavelength, and they often require cryogenic cooling for measurements of far-infrared (FIR) radiation or very low-temperature objects, which result in a significant increase in the system’s size, weight, and power (SWaP). While thermal detectors based upon thermopiles are uncooled and sensitive to a wide range of wavelengths including FIR radiation, their sensitivity, limited by the material’s thermoelectric response and heat losses, is an order of magnitude lower than photon detectors. To address the sensitivity requirements for future planetary science missions that target very cold objects such as ice giant planets, icy regoliths, planetary satellites, and primitive bodies, we introduce a high-sensitive broadband thermopile concept using holey silicon – a thin membrane of silicon with a microfabricated arrangement of pores that can be optimized to minimize heat losses and enable breakthrough thermoelectric performance. In this paper, we present our analytical model for the holey silicon-based thermopile, its performance expectations, and its performance comparisons with the state-of-the-art thermopile technology. We will investigate the roles of thermal conductance in holey silicon-based thermopile performance, the impact of thermal conduction and thermal radiation at different temperature limits, and the performance trade-off between the responsivity and noises.

thermopiles↗

Sensitivity Analysis of an LCC-LCC Compensated 20-kW Bidirectional Wireless Charging System for Medium-Duty Vehicles

In this paper, sensitivity analysis of an LCC-LCC compensated bidirectional wireless charging system is presented. In a wireless charging system for electric vehicle applications, the effective load impedance varies significantly with the state-of-charge (SOC)of the battery. Due to the change in system parameters, resonant frequency, and transferred power, the efficiency of the system varies significantly. Sensitivity analysis of the system characteristics reveals the optimal operating region and required control strategy to operate within that region. Sensitivity analysis is even more important for a bidirectional system with mismatched input and output voltage levels. In this paper, the sensitivity of a bidirectional 20 kW wireless charging system is investigated analytically and the results are validated experimentally. The experimental results for a geometrically matched Double-D (DD) coil-based LCC-LCC tuned bidirectional WCS with asymmetric voltage levels show that the voltage gains and input impedance of the system are highly sensitive near the resonant frequency.

Mostak, Mostak Mohammad↗

Method for lithograghic patterning of sensitive materials

Methods for patterning highly sensitive materials, such as organic materials, organic semiconductors, biomolecular materials, and the like, with photolithographic resolution are disclosed. In some embodiments, a germanium mask (304) is formed on the surface of the sensitive material (302), thereby protecting it from subsequent processes that employ harsh chemicals that would otherwise destroy the sensitive material (302). A microlithography mask (306) is patterned on the germanium mask layer (304), after which the germanium exposed by the microlithography mask (306) is removed by dissolving it in water. After transferring the pattern of the germanium mask (304) into the sensitive material (302), the germanium and microlithography masks (304, 306) are completely removed by immersing the substrate in water, which dissolves the remaining germanium and lifts off the microlithography mask material. As a result, the only chemical to which the sensitive material (302) is exposed during the patterning process is water, thereby mitigating or avoiding damage to the material (302).

36 MATERIALS SCIENCE↗

Reactivity Coefficient Measurements and Sensitivity Studies [Abstract]

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor (k eff ). K eff is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while k eff is a well-documented parameter with detailed sensitivity and uncertainty analysis, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific nuclear data by optimally designing experiments that are sensitive to a suite of measurement parameters beyond k eff . By identifying how each parameter's nuclear data sensitivity differs from others, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes reactivity coefficient sensitivities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Bayesian approach to the long-baseline neutrino oscillation sensitivity of DUNE

The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is evaluated using a Bayesian Markov Chain Monte Carlo (MCMC) approach. This analysis uses the same underlying sensitivity inputs as previous DUNE studies [Eur. Phys. J. C 80, 978 (2020)], and therefore does not present updated DUNE sensitivities, but instead explores the additional inferences accessible using a Bayesian approach. We present four-dimensional posterior probability distributions of the oscillation parameters, highlighting the breadth of correlation in the parameter space of interest, especially between $\sin^2 θ_{23}$ and $\sin^2 θ_{13}$. We exploit the flexibility of the Bayesian framework to incorporate parameter constraints post hoc and assess the impact of applying a reactor short-baseline $θ_{13}$ constraint. A significant increase in the sensitivity to the $θ_{23}$ octant is found when including the constraint. Posterior distributions of derived quantities can be easily constructed from MCMC results. This work presents the first study of DUNE's sensitivity to the Jarlskog invariant, $J$, a quantity that provides a parametrisation-independent measure of charge-parity violation in the leptonic sector.

Abbaslu, Saeed [IPM, Tehran] (ORCID:00000003356771↗

PDE 5 inhibitor improves insulin sensitivity by enhancing mitochondrial function in adipocytes

Adipocytes are involved in many metabolic disorders. It was recently reported that phosphodiesterase type 5 (PDE5) is expressed in human adipose tissue. In addition, PDE5 inhibitors have been shown to improve insulin sensitivity in humans. However, the mechanism underlying the role of PDE5 inhibitors as an insulin sensitizer remains largely unknown. The present study was undertaken to investigate the role of the PDE5 inhibitor udenafil in insulin signaling in adipocytes and whether this is mediated through the regulation of mitochondrial function. To study the mechanism underlying the insulin sensitizing action of PDE5 inhibitors, we evaluated quantitative changes in protein or mRNA levels of mitochondrial oxidative phosphorylation (OxPhos) complex, oxygen consumption rate (OCR), and fatty acid oxidation with varying udenafil concentrations in 3T3-L1 cells. Our cell study suggested that udenafil enhanced the insulin signaling pathway in 3T3-L1 cells. Following udenafil treatment, basal mitochondrial OCR, maximal OxPhos capacity, and OxPhos gene expression significantly increased. Finally, we examined whether udenafil can affect the fatty acid oxidation process. Treatment of 3T3-L1 cells with udenafil (10 and 20 μM) significantly increased fatty acid oxidation rate in a dose-dependent manner. In addition, the expression of peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC-1α) significantly increased. We demonstrated that the PDE5 inhibitor udenafil enhances insulin sensitivity by improving mitochondrial function in 3T3-L1 cells. This might be the mechanism underlying the PDE5 inhibitor-enhanced insulin signaling in adipocytes. This also suggests that udenafil may provide benefit in the treatment of type 2 diabetes and other related cardiovascular diseases. - Highlights: • Udenafil enhanced the insulin signaling pathway. • Udenafil improved mitochondrial function by increasing oxygen consumption rate (OCR). • Udenafil upregulated mitochondrial OxPhos gene expression. • Udenafil was involved in increasing fatty acid oxidation (FAO).

60 APPLIED LIFE SCIENCES↗

Sensitivity Studies, Gap Analysis, and Benchmark Experiment Optimization for Reactor Physics and Criticality Safety Applications

Many new reactor designs, such as advanced reactors and micro reactors, have materials that lack nuclear data validation. This is also true for many other applications in criticality safety and global security. Both differential and integral experiments are needed to validate cross-section data. Without this, a user cannot have confidence in the predicted results of a radiation-transport code. This work describes an approach called ARCHIMEDES (Application Relevant Critical/Subcritical HEU/Pu-based Integral Measurements for Enhancing Data and Evaluating Sensitivities) to design new criticality experiments that have similar k eff cross-section sensitivities to an application of interest. This process involves simulations to generate cross-section sensitivities to a parameter of interest (such as k eff ), a gap analysis to determine which existing benchmarks are most similar to the application, and an experiment optimization. Recently, there has been a great deal of interest in the reactor physics community on advanced reactors, micro reactors, and accelerator driven systems (ADS). This work will apply the described method to specific examples in this area. The focus of this work will be on the sensitivity study and gap analysis, while future work will include experiment design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PEBBED Uncertainty and Sensitivity Analysis of the CRP-5 PBMR DLOFC Transient Benchmark with the SUSA Code

The need for a defendable and systematic uncertainty and sensitivity approach that conforms to the Code Scaling, Applicability, and Uncertainty (CSAU) process, and that could be used for a wide variety of software codes, was defined in 2008. The GRS (Gesellschaft für Anlagen und Reaktorsicherheit) company of Germany has developed one type of CSAU approach that is particularly well suited for legacy coupled core analysis codes, and a trial version of their commercial software product SUSA (Software for Uncertainty and Sensitivity Analyses) was acquired on May 12, 2010. This report summarized the results of the initial investigations performed with SUSA, utilizing a typical High Temperature Reactor benchmark (the IAEA CRP-5 PBMR 400MW Exercise 2) and the PEBBED-THERMIX suite of codes. The following steps were performed as part of the uncertainty and sensitivity analysis: 1. Eight PEBBED-THERMIX model input parameters were selected for inclusion in the uncertainty study: the total reactor power, inlet gas temperature, decay heat, and the specific heat capability and thermal conductivity of the fuel, pebble bed and reflector graphite. 2. The input parameters variations and probability density functions were specified, and a total of 800 PEBBED-THERMIX model calculations were performed, divided into 4 sets of 100 and 2 sets of 200 Steady State and Depressurized Loss of Forced Cooling (DLOFC) transient calculations each. 3. The steady state and DLOFC maximum fuel temperature, as well as the daily pebble fuel load rate data, were supplied to SUSA as model output parameters of interest. The 6 data sets were statistically analyzed to determine the 5% and 95% percentile values for each of the 3 output parameters with a 95% confidence level, and typical statistical indictors were also generated (e.g. Kendall, Pearson and Spearman coefficients). 4. A SUSA sensitivity study was performed to obtain correlation data between the input and output parameters, and to identify the primary contributors to the output data uncertainties. It was found that the uncertainties in the decay heat, pebble bed and reflector thermal conductivities were responsible for the bulk of the propagated uncertainty in the DLOFC maximum fuel temperature. It was also determined that the two standard deviation (2s) uncertainty on the maximum fuel temperature was between ±58oC (3.6%) and ±76oC (4.7%) on a mean value of 1604 oC. These values mostly depended on the selection of the distributions types, and not on the number of model calculations above the required Wilks criteria (a (95%,95%) statement would usually require 93 model runs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CASL L1 Milestone Report: CASL.P4.01, Sensitivity and Uncertainty Analysis for CIPS with VIPRE-W and BOA

The CASL Level 1 Milestone CASL.P4.01, successfully completed in December 2011, aimed to 'conduct, using methodologies integrated into VERA, a detailed sensitivity analysis and uncertainty quantification of a crud-relevant problem with baseline VERA capabilities (ANC/VIPRE-W/BOA).' The VUQ focus area led this effort, in partnership with AMA, and with support from VRI. DAKOTA was coupled to existing VIPRE-W thermal-hydraulics and BOA crud/boron deposit simulations representing a pressurized water reactor (PWR) that previously experienced crud-induced power shift (CIPS). This work supports understanding of CIPS by exploring the sensitivity and uncertainty in BOA outputs with respect to uncertain operating and model parameters. This report summarizes work coupling the software tools, characterizing uncertainties, and analyzing the results of iterative sensitivity and uncertainty studies. These studies focused on sensitivity and uncertainty of CIPS indicators calculated by the current version of the BOA code used in the industry. Challenges with this kind of analysis are identified to inform follow-on research goals and VERA development targeting crud-related challenge problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of FEAST-Metal Fuel Performance Code: Initial Results

This memo documents the completion of the LANL milestone, M3FT-12LA0202041, describing methodologies and initial results using FEAST-Metal. The FEAST-Metal code calculations for this work are being conducted at LANL in support of on-going activities related to sensitivity analysis of fuel performance codes. The objective is to identify important macroscopic parameters of interest to modeling and simulation of metallic fuel performance. This report summarizes our preliminary results for the sensitivity analysis using 6 calibration datasets for metallic fuel developed at ANL for EBR-II experiments. Sensitivity ranking methodology was deployed to narrow down the selected parameters for the current study. There are approximately 84 calibration parameters in the FEAST-Metal code, of which 32 were ultimately used in Phase II of this study. Preliminary results of this sensitivity analysis led to the following ranking of FEAST models for future calibration and improvements: fuel conductivity, fission gas transport/release, fuel creep, and precipitation kinetics. More validation data is needed to validate calibrated parameter distributions for future uncertainty quantification studies with FEAST-Metal. Results of this study also served to point out some code deficiencies and possible errors, and these are being investigated in order to determine root causes and to improve upon the existing code models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Can nudging be used to quantify model sensitivities in precipitation and cloud forcing?

Efficient simulation strategies are crucial for the development and evaluation of high resolution climate models. This paper evaluates simulations with constrained meteorology for the quantification of parametric sensitivities in the Community Atmosphere Model version 5 (CAM5). Two parameters are perturbed as illustrating examples: the convection relaxation time scale (TAU), and the threshold relative humidity for the formation of low-level stratiform clouds (rhminl). Results suggest that the fidelity and computational efficiency of the constrained simulations depend strongly on 3 factors: the detailed implementation of nudging, the mechanism through which the perturbed parameter affects precipitation and cloud, and the magnitude of the parameter perturbation. In the case of a strong perturbation in convection, temperature and/or wind nudging with a 6-hour relaxation time scale leads to non-negligible side effects due to the distorted interactions between resolved dynamics and parameterized convection, while a 1-year free running simulation can satisfactorily capture the annual mean precipitation sensitivity in terms of both global average and geographical distribution. In the case of a relatively weak perturbation the large-scale condensation scheme, results from 1-year free-running simulations are strongly affected by noise associated with internal variability, while nudging winds effectively reduces the noise, and reasonably reproduces the response of precipitation and cloud forcing to parameter perturbation. These results indicate that caution is needed when using nudged simulations to assess precipitation and cloud forcing sensitivities to parameter changes in general circulation models. We also demonstrate that ensembles of short simulations are useful for understanding the evolution of model sensitivities.

54 ENVIRONMENTAL SCIENCES↗