Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Geometric invariants of quantum metrology

Here, we establish a conservation law for the Quantum Fisher Information Matrix (QFIM) expressed as follows; when the QFIM is constructed from a set of observables closed under commutation, i.e., a Lie algebra, the spectrum of the QFIM is invariant under unitary dynamics generated by these same operators. Each Lie algebra therefore endows any quantum state with a fixed “budget” of metrological sensitivity—an intrinsic resource that we show, like optical squeezing in interferometry, cannot be amplified by symmetry-preserving operations. The Uhlmann curvature tensor naturally inherits the same symmetry group, and so quantum incompatibility is similarly fixed. As a result, a metrological analog to Liouville's theorem appears; statistical distances, volumes, and curvatures are invariant under the evolution generated by the Lie algebra. We discuss this as it relates to the quantum analogs of classical optimality criteria. This enables one to efficiently classify useful classes of quantum states at the level of Lie algebras through geometric invariants.

Wilson, Christopher [University of Colorado, Bould↗

New Cross Section Measurements and Evaluations of Zirconium Isotopes [Slides]

This presentation gives a look to new cross section measurements and evaluations of Zirconium (Zr) isotopes. This lecture includes highlights of accomplishments made in 2022. Additionally, it explains the motivation for investigation, new measurements, and re-evaluation of the Zr isotopes. This presentation concludes with a preliminary evaluation result from RPI 90 Zr evaluation and preliminary results from Eigenvalue sensitivity study on Zr sensitive critical benchmark experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Rare earth and zinc layered hydroxide salts intercalated with the 2-aminobenzoate anion as organic luminescent sensitizer

Rare earth (RE = Eu, Y and Tb) and zinc layered hydroxide salts intercalated with nitrate anions were synthesized, followed by exchange with 2-aminobenzoate. The UV absorption ability was improved after intercalation/grafting in relation to that shown by the parent material. - Highlights: • Rare earth (RE = Eu, Y and Tb) and zinc layered hydroxide were synthesized. • Intercalated nitrate anions were exchanged by 2-aminobenzoate. • In all the 2-aminobenzoate containing compounds, the grafting reaction was detected. • The UV absorption ability was improved after the exchange reactions. • Rare earth hydroxide salts are potential matrixes to produce luminescent materials. - Abstract: Rare earth (RE = Eu, Y and Tb) and zinc layered hydroxide salts intercalated with nitrate anions were synthesized, followed by exchange with 2-aminobenzoate. The obtained compounds were characterized by powder X-ray diffraction (PXRD), Fourier transform infrared (FTIR) and ultraviolet visible (UV–vis) spectroscopies, fluorescence measurements and thermal analysis (TGA/DTA). The results from FTIR spectroscopy suggest a direct coordination of 2-aminobenzoate to the metal cations of the inorganic layered structure. The organic derivative products from the intercalation reactions absorb a broader range of UV-light in relation to that shown by the parent material; the photoluminescence measurements present a strong violet, blue and green luminescence under UV-light excitation for layered compounds with, Zn, Y and Tb, respectively. Rare earth hydroxide salts (RE-LHS) are potential alternative matrices for the immobilization of organic species to produce luminescent materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PDE-constrained high-order mesh optimization

Here, we present a novel framework for PDE-constrained r-adaptivity of high-order meshes. The proposed method formulates mesh movement as an optimization problem, with an objective function defined as a convex combination of a mesh quality metric and a measure of the accuracy of the PDE solution obtained via finite element discretization. The proposed formulation achieves optimized, well-defined high-order meshes by integrating mesh quality control, PDE solution accuracy, and robust gradient regularization. We adopt the Target-Matrix Optimization Paradigm to control geometric properties across the mesh, independent of the PDE of interest. To incorporate the accuracy of the PDE solution, we introduce error measures that control the finite element discretization error. The implicit dependence of these error measures on the mesh nodal positions is accurately captured by adjoint sensitivity analysis. Additionally, a convolution-based gradient regularization strategy is used to ensure stable and effective adaptation of high-order meshes. We demonstrate that the proposed framework can improve mesh quality and reduce the error by up to 10 times for the solution of Poisson and linear elasto-static problems. The approach is general with respect to the dimensionality, the order of the mesh, the types of mesh elements, and can be applied to any PDE that admits well-defined adjoint operators.

Computer science↗

A novel mitochondria-targeted two-photon fluorescent probe for dynamic and reversible detection of the redox cycles between peroxynitrite and glutathione

Highlights: • We report a two-photon fluorescent probe (TP-Se) for optical imaging. • TP-Se can monitor reversibly changes in ONOO{sup −}/GSH levels in mitochondria. • TP-Se will lead to significant development on redox events in cellular redox regulation. Redox homeostasis is important for maintenance of normal physiological functions within cells. Redox state of cells is primarily a consequence of precise balance between levels of reducing equivalents and reactive oxygen species. Redox homeostasis between peroxynitrite (ONOO{sup −}) and glutathione (GSH) is closely associated with physiological and pathological processes, such as prolonged relaxation in vascular tissues and smooth muscle preparations, attenuation of hepatic necrosis, and activation of matrix metalloproteinase-2. We report a two-photon fluorescent probe (TP-Se) based on water-soluble carbazole-based compound, which integrates with organic selenium, to monitor changes in ONOO{sup −}/GSH levels in cells. This probe can reversibly respond to ONOO{sup −} and GSH and exhibits high selectivity, sensitivity, and mitochondrial targeting. The probe was successfully applied to visualize changes in redox cycles during ONOO{sup −} outbreak and antioxidant GSH repair in cells. The probe will lead to significant development on redox events involved in cellular redox regulation.

60 APPLIED LIFE SCIENCES↗

N→Δ Asymmetry at Low Q2

The Qweak collaboration at Jefferson Lab is determining the weak charge of the proton. This is done by measuring the parity-violating asymmetry of polarized electrons scattered elastically from the proton at a low $Q^2$ of 0.026 $(GeV/c)^2$. The measured asymmetry is partially diluted by polarized electrons inelastically scattered off the proton. Some Qweak experiment running time was used to measure the asymmetry in the inelastic region, which is dominated by the $N \rightarrow \Delta$ transition. In addition to constraining backgrounds for Qweak the $N \rightarrow \Delta$ asymmetry measurement is sensitive to a weakly constrained and theoretically uncertain low energy constant $d_{\Delta}$. The term involving $d_{\Delta}$ (the ``Siegert'' term) is non-vanishing in the limit $Q^2 \rightarrow 0$, thus it can dominate the asymmetry at low $Q^2$. This hadronic electroweak radiative correction is driven by the same matrix element responsible for the large SU(3) breaking effects observed in hyperon decays. An update on the analysis will be presented.

Leacock, John↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

REVIEW OF PROPOSED METHODOLOGY FOR A RISK- INFORMED RELAXATION TO ASME SECTION XI APPENDIX G

The current regulations, as set forth by the United States Nuclear Regulatory Commission (NRC), to insure that light-water nuclear reactor pressure vessels (RPVs) maintain their structural integrity when subjected to planned normal reactor startup (heat-up) and shut-down (cool-down) transients are specified in Appendix G to 10 CFR Part 50, which incorporates by reference Appendix G to Section XI of the American Society of Mechanical Engineers (ASME) Code. The technical basis for these regulations are now recognized by the technical community as being conservative and some plants are finding it increasingly difficult to comply with the current regulations. Consequently, the nuclear industry has developed, and submitted to the ASME Code for approval, an alternative risk-informed methodology that reduces the conservatism and is consistent with the methods previously used to develop a risk-informed revision to the regulations for accidental transients such as pressurized thermal shock (PTS). The objective of the alternative methodology is to provide a relaxation to the current regulations which will provide more operational flexibility, particularly for reactor pressure vessels with relatively high irradiation levels and radiation sensitive materials, while continuing to provide reasonable assurance of adequate protection to public health and safety. The NRC and its contractor at Oak Ridge National Laboratory (ORNL) have recently performed an independent review of the industry proposed methodology. The NRC / ORNL review consisted of performing probabilistic fracture mechanics (PFM) analyses for a matrix of cool-down and heat-up rates, permutated over various reactor geometries and characteristics, each at multiple levels of embrittlement, including 60 effective full power years (EFPY) and beyond, for various postulated flaw characterizations. The objective of this review is to quantify the risk of a reactor vessel experiencing non-ductile fracture, and possible subsequent failure, over a wide range of normal transient conditions, when the maximum allowable thermal-hydraulic boundary conditions, derived from both the current ASME code and the industry proposed methodology, are imposed on the inner surface of the reactor vessel. This paper discusses the results of the NRC/ORNL review of the industry proposal including the matrices of PFM analyses, results, insights, and conclusions derived from these analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrogel nanoparticle based immunoassay

An immunoassay device incorporating porous polymeric capture nanoparticles within either the sample collection vessel or pre-impregnated into a porous substratum within fluid flow path of the analytical device is presented. This incorporation of capture particles within the immunoassay device improves sensitivity while removing the requirement for pre-processing of samples prior to loading the immunoassay device. A preferred embodiment is coreshell bait containing capture nanoparticles which perform three functions in one step, in solution: a) molecular size sieving, b) target analyte sequestration and concentration, and c) protection from degradation. The polymeric matrix of the capture particles may be made of co-polymeric materials having a structural monomer and an affinity monomer, the affinity monomer having properties that attract the analyte to the capture particle. This device is useful for point of care diagnostic assays for biomedical applications and as field deployable assays for environmental, pathogen and chemical or biological threat identification.

47 OTHER INSTRUMENTATION↗

Sterile Neutrino Search with the NOvA Detectors

NOvA is a two-detector experiment designed to observe neutrino oscillations from νµ toνe flavor states. Additionally, the location of the NOvA Near Detector is well situated to additionally observe short base line oscillations to sterile neutrino states. We expand upon previous NOvA sterile neutrino searches by using a covariance matrix fitting technique. This analysis is the first with NOvA to directly include neutrino interactions in the Near Detector while fitting the data. The NOvA Near Detector’s greater statistics to better constrain our Far Detector uncertainties in addition to increasing the range of Δ m$^2_{41}$ to which we are sensitive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rapid prediction of fuel research octane number and octane sensitivity using the AFIDA constant-volume combustion chamber

Current research octane number (RON) and motor octane number (MON) gasoline performance characterization techniques use dated, complex engine testing methodology and limit researchers’ ability to easily characterize small volumes of experimental fuels. A novel methodology is presented that correlates measured ignition delay (ID) time to RON in an Advanced Fuel Ignition Delay Analyzer (AFIDA) constant-volume combustion chamber device at a single pressure/temperature condition, with an r2 of 0.99 and standard error (SE) of 1.0. The correlation of the slope of the ID time between two additional temperature points to octane sensitivity (S) produces an r2 of 0.97 and SE of 0.69; however, fuels with S>12 are indistinguishable. These results are based on methodology calibration using 31 primary and toluene reference fuels containing 0%-40% ethanol with RON values ranging from 85 to 113. Validation of these methods using a 102-sample fuel matrix spanning an array of base fuels and additive chemistry designed to test the robust applicability of the method, along with pump gasoline and high-octane surrogate blend samples, demonstrates an r2 of 0.94 and SE of 1.3 for the RON correlation over all samples, whereas the equivalent S correlation produces an r2 of 0.78 and SE of 1.2 by excluding two additives, 3-pentanone and diisobutylene, which displayed poor S correlation results. This novel AFIDA analysis method can be performed in 1 h and with 40 mL of fuel, offering significant improvements in time and volume requirements over traditional techniques.

33 ADVANCED PROPULSION SYSTEMS↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Newly Released Capabilities in the Distributed-Memory SuperLU Sparse Direct Solver

We present the new features available in the recent release of SuperLU_DIST, Version 8.1.1. SuperLU_DIST is a distributed-memory parallel sparse direct solver. The new features include (1) a 3D communication-avoiding algorithm framework that trades off inter-process communication for selective memory duplication, (2) multi-GPU support for both NVIDIA GPUs and AMD GPUs, and (3) mixed-precision routines that perform single-precision LU factorization and double-precision iterative refinement. Apart from the algorithm improvements, we also modernized the software build system to use CMake and Spack package installation tools to simplify the installation procedure. Throughout the article, we describe in detail the pertinent performance-sensitive parameters associated with each new algorithmic feature, show how they are exposed to the users, and give general guidance of how to set these parameters. We illustrate that the solver’s performance both in time and memory can be greatly improved after systematic tuning of the parameters, depending on the input sparse matrix and underlying hardware.

97 MATHEMATICS AND COMPUTING↗

{beta}-delayed {alpha} decay of {sup 16}N

The {beta}-delayed {alpha} decay of {sup 16}N has been used to restrict the E1 fraction of the ground state {gamma} transition in the astrophysically important {sup 12}C({alpha},{gamma}){sup 16}O reaction in several experiments. A review of the published measurements is given, and GEANT4 simulations and R-matrix calculations are presented to further clarify the observed {alpha} spectra. A clear response function, in the form of a low-energy tail from the scattering of {alpha} particles in the catcher foil, is observed in these simulations for any foil thickness. Contrary to claims in the literature, the simulations show that the TRIUMF measurement and those performed at Yale and Mainz originate from the same underlying spectrum. The simulations suggest that the discrepancies between the Yale and TRIUMF final results can be attributed to incorrect deconvolution methods applied in the former case. The simulations show in general that the form (width) of the spectrum is very sensitive to the catcher foil thickness. It is concluded that the TRIUMF measurement most likely represents the currently closest approximation to the true {beta}-delayed {alpha}-decay spectrum of {sup 16}N.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proposal to search for mu- N -> e- N with a single event sensitivity below 10 -16

We propose a new experiment, Mu2e, to search for charged lepton flavor violation with unprecedented sensitivity. We will measure the ratio of the coherent neutrinoless conversion in the field of a nucleus of a negatively charged muon into an electron to the muon capture process: R{sub {mu}e} = {mu}{sup -} + A(Z,N) {yields} e{sup -} + A(Z,N)/{mu}{sup -} + A(Z,N) {yields} {nu}{sub {mu}} + A(Z-1, N), with a sensitivity R{sub {mu}e} {le} 6 x 10{sup -17} at 90% CL. This is almost a four order-of-magnitude improvement over the existing limit. The observation of such a process would be unambiguous evidence of physics beyond the Standard Model. Since the discovery of the muon in 1936, physicists have attempted to answer I.I. Rabi's famous question: 'Who ordered that?' Why is there a muon? What role does it play in the larger questions of why there are three families and flavors of quarks, leptons, and neutrinos? We know quarks mix through a mechanism described by the Cabbibo-Kobayashi-Maskawa matrix, which has been studied for forty years. Neutrino mixing has been observed in the last decade, but mixing among the family of charged leptons has never been seen. The current limits are of order 10{sup -11} - 10{sup -13} so the process is rare indeed. Why is such an experiment important and timely? A major motivation for experiments at the Large Hadron Collider (LHC) is the possible observation of supersymmetric particles in the TeV mass range. Many of these supersymmetric models predict a {mu}-e conversion signal at R{sub {mu}e} {approx} 10{sup -15}. We propose to search for {mu}-e conversion at a sensitivity that exceeds this by more than an order of magnitude. The LHC may not be able to conclusively distinguish among supersymmetric models, so Mu2e will provide invaluable information should the LHC observe a signal. In the case where the LHC finds no evidence of supersymmetry, or other beyond-the-standard-model physics, Mu2e will probe for new physics at mass scales up to 10{sup 4} TeV, far beyond the reach of any planned accelerator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of noncollinear parton dynamics in the prompt photon photoproduction at HERA

We investigate the prompt photon photoproduction at HERA within the framework of the k{sub T}-factorization QCD approach. Our consideration is based on the off-shell matrix elements for the underlying partonic subprocesses. The unintegrated parton densities in a proton and in a photon are determined using the Kimber-Martin-Ryskin prescription. Additionally, we use the Ciafaloni-Catani-Fiorani-Marchesini-evolved unintegrated gluon as well as valence and sea quark distributions in a proton. A conservative error analysis is performed. Both inclusive and associated with the hadronic jet production rates are investigated. The theoretical results are compared with the recent experimental data taken by the H1 and ZEUS Collaborations. We study also the specific kinematical properties of the photon-jet system which are strongly sensitive to the transverse momentum of incoming partons. Using the Kimber-Martin-Ryskin scheme, the contribution from the quarks emerging from the earlier steps of the parton evolution is estimated and found to be of 15%-20% approximately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗