Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Autler-Townes spectroscopy of a Rydberg ladder

Ladder-type two-photon excitation of an atom from a ground state $|g\rangle$, to an intermediate excited state $|e\rangle$, and finally, to a Rydberg state $|r\rangle$ has a variety of uses from quantum information to sensing. A common scheme for detecting this transition optically is through electromagnetically induced transparency (EIT). However, in inverted wavelength schemes, where the ground-to-excited transition wavelength is shorter than the excited-to-Rydberg transition wavelength, the strength of the EIT feature on the lower-leg beam is strongly reduced in a Doppler-broadened medium. Here, in this study, we report on an alternative two-photon spectroscopic feature, which we term the two-photon Autler-Townes resonance, observed on the upper-leg beam. Compared to the EIT signal, this feature's superior signal-to-noise ratio allows one to resolve Rydberg resonances with principal quantum number as high as n=80. We also show that such a feature can be utilized to generate an error signal for stabilizing the frequency of the upper-leg beam.

Xiang, Tai [University of California, Berkeley, CA↗

Dissipativity-based design of local and wide-area DER controls for large-scale power systems with high penetration of renewables

In this paper, an integrated and modular control design is developed for distributed energy resources (DERs) to stabilize power systems and minimize effects of load variations and intermittent generation. Traditionally, the droop control of each generator (or virtual power plant) works as a local feedback loop to track frequency during load disturbance, whereas automatic generation control (AGC) calculates control signals and sends them to each generator with the goal of matching the total generation and load in the overall system. The droop control and the AGC work separately, therefore the two controls often conflict each other. The proposed design enables us to modularly synthesize an integrated control for each of the DERs by using both local and wide-area measurements so that the controls work together in enhancing stability and performance of the power system. The design methodology admits the full nonlinear power flow equations, and it results in a data-driven control that in real-time takes into account the nonlinear power flow interactions (in terms of current angle measurements) and adaptively adjusts parameters of the controls that operate the DERs. The design framework uses the concept of passivity-short systems to analyze individual DERs and quantify their dynamic responses in such a way that the resulting system-wide implementation becomes plug-and-play. Simulations are done to demonstrate the effectiveness of the proposed methodology and design.

Harvey, Roland↗

Displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor

The experiments of displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor are presented. The CMOS APS image sensors are manufactured in the standard 0.35 μm CMOS technology. The flux of neutron beams was about 1.33 × 10{sup 8} n/cm{sup 2}s. The three samples were exposed by 1 MeV neutron equivalent-fluence of 1 × 10{sup 11}, 5 × 10{sup 11}, and 1 × 10{sup 12} n/cm{sup 2}, respectively. The mean dark signal (K{sub D}), dark signal spike, dark signal non-uniformity (DSNU), noise (V{sub N}), saturation output signal voltage (V{sub S}), and dynamic range (DR) versus neutron fluence are investigated. The degradation mechanisms of CMOS APS image sensors are analyzed. The mean dark signal increase due to neutron displacement damage appears to be proportional to displacement damage dose. The dark images from CMOS APS image sensors irradiated by neutrons are presented to investigate the generation of dark signal spike.

36 MATERIALS SCIENCE↗

In situ calibration of a light source in a sensor device

A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

58 GEOSCIENCES↗

AUTOMATED TRANSIENT IDENTIFICATION IN THE DARK ENERGY SURVEY

We describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm’s performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.

79 ASTRONOMY AND ASTROPHYSICS↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of the internal quantum efficiency in GaN via analysis of the heat generated by non-radiative recombination processes

The internal quantum efficiency (IQE) in a GaN epilayer is quantified using transient lens (TL) spectroscopy and numerical simulations. TL spectroscopy can optically detect temperature and carrier changes induced in a photo-pumped GaN layer, and the observed temperature change is closely associated with non-radiative recombination processes that create heat. Then numerically solving diffusion equations, which represent the diffusion processes of the photo-generated heat and carriers, provide the spatiotemporal distributions. These distributions are subsequently converted into the refractive index distributions, which act as transient convex or concave lenses. Finally, ray-tracing simulations predict the TL signals. Comparing the experimentally obtained and simulated TL signals quantifies the generated heat and the IQE without the often-adopted assumption that non-radiative recombination processes are negligible at low temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method for high power diode based additive manufacturing

The present disclosure relates to a system for performing an Additive Manufacturing (AM) fabrication process on a powdered material, deposited as a powder bed and forming a substrate. The system makes use of a laser for generating a laser beam, and an optical subsystem. The optical subsystem is configured to receive the laser beam and to generate an optical signal comprised of electromagnetic radiation sufficient to melt or sinter the powdered material. The optical subsystem uses a digitally controlled mask configured to pattern the optical signal as needed to melt select portions of a layer of the powdered material to form a layer of a 3D part. A power supply and at least one processor are also included for generating a plurality of different power density levels selectable based on a specific material composition, absorptivity and diameter of the powder particles, and a known thickness of the powder bed. The powdered material is used to form the 3D part in a sequential layer-by-layer process.

El-Dasher, Bassem S.↗

D-DMTD: Digital Dual Mixer Time Difference

The digital design discussed in the following document is inspired by the digital dual mixer time difference circuit and based on the white paper, Digital femtosecond time difference circuit for CERN's timing system. DMTD is originally an analog technique that measures the time difference between two events with high precision using a commercial time interval counter. Our project applies this analog concept to a digital system programmed onto a Microsemi ProASIC3E FPGA (Field- Programmable Gate Array). D-DMTD is a digital system theoretically capable of measuring the time difference between two digital clock signals with very fine resolution (sub-picosecond) using a relatively low frequency counter. The system essentially acts as a digital phase detector with femtosecond time resolution. The main concern with this processing technique is its feasibility and accuracy when implemented on an FPGA. Another concern is the environmentally-induced, horizontal phase noise in the digital signals; this 'litter" jeopardizes the fidelity of the clocks and generates glitches in the signals. Thus, the majority of the work was focused on determining under what conditions the digital design performs optimally and generates the most accurate estimations for the phase shift.

42 ENGINEERING↗

Coherence Spectroscopy in the Condensed Phase: Insights into Molecular Structure, Environment, and Interactions

The role of coherences, or coherently excited superposition states, in complex condensed-phase systems has been the topic of intense interest and debate for a number of years. In many cases, coherences have been utilized as spectators of ultrafast dynamics or for identifying couplings between electronic states. In rare cases, they have been found to drive excited state dynamics directly. Interestingly though, the utilization of coherences as a tool for high-detail vibronic spectroscopy has largely been overlooked until recently, despite their encoding of key information regarding molecular structure, electronically sensitive vibrational modes, and intermolecular interactions. Furthermore, their detection in the time domain makes for a highly comprehensive spectroscopic technique wherein the phase and dephasing times are extracted in addition to amplitude and intensity, an element not afforded in analogous frequency domain “steady-state” measurements. However, practical limitations arise in disentangling the large number of coherent signals typically accessed in broadband nonlinear spectroscopic experiments, often complicating assignment of the origin and type of coherences generated. Two-dimensional electronic spectroscopy (2DES) affords an avenue by which to disperse and decompose the large number of coherent signals generated in nonlinear experiments, facilitating the assignment of various types of quantum coherences. 2DES takes advantage of the broad bandwidth necessary for achieving the high time resolution desired for ultrafast dynamics and coherence generation by resolving the excitation axis to detect all excitation channels independently. This feature is beneficial for following population dynamics such as electronic energy transfer, and 2DES has become the choice method for such studies. Simultaneously, coherences arise as oscillations at well-defined coordinates across the 2D map often atop those evolving population signals. By isolating the coherent contribution to the 2DES data and Fourier transforming along the population time, a 3D spectral representation of the coherent 2D data is generated, and coherences are then ordered by their oscillation frequency, ν2. Individual coherences can then be selected by their frequency and evaluated via their distinct “2D coherence” spectra, yielding a significantly more distinctive set of spectroscopic signatures over other 1D methodologies and single-point 2DES analysis. Given that coherences of different origin result in unique 2D coherence spectra, these characteristics can be catalogued and compared directly against experiment for prompt assignment, a strategy not afforded by traditional 2DES analysis. In this Account, a structure-driven time-independent spectral model is discussed and employed to compare the 2D fingerprints of various coherences to experimental 2D coherence spectra. The frequency-domain approach can easily integrate ab initio derived vibronic parameters, and its correspondence with experimental coherence spectra of a model compound is demonstrated. Several examples and applications are discussed herein, from 2D Franck–Condon analysis of a model compound, to identifying the signatures of interpigment vibronic coupling in a photosynthetic light-harvesting complex. The 3D spectral approach to 2DES provides remarkable spectroscopic detail, in turn leading to new insights in molecular structure and interactions, which complement the time-resolved dynamics simultaneously recorded. The approach presented herein has the potential to distill down the convoluted set of nonlinear signals appearing in 2D coherent spectra, making the technique more amenable to high-detail vibronic spectroscopy in inherently complex condensed phase systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exposing Key Vibrational Contributions to Properties of Organic Molecular Solids with High Signal, Low Frequency Neutron Spectroscopy and Ab Initio Simulations

Stability and response of supramolecular forms is important to many areas in materials science, and contributions from vibrations can be crucial. In this study, we have collected the first spectra of organic molecular crystals and polymorphic cocrystals using the next-generation, high-signal VISION spectrometer in the far-infrared (FIR) and mid-infrared (MIR) range. Unambiguously different spectral signatures were found for carbamazepine and two polymorphs of the carbamazepine-saccharin cocrystal, including numerous modes undetectable with optical methods. For FIR-range frequencies, in addition to correct calculation of peak positions, accurate line-shape features were reproducible by simulation using ab initio vibrational calculations. Finally, high confidence spectral assignments and thermochemical information for this region are thus expected, and a benchmark for vibrational ab initio calculations is provided, creating a significant addition to methods used in investigation and design of organic materials.

36 MATERIALS SCIENCE↗

The large enriched germanium experiment for neutrinoless double beta decay (LEGEND)

We report the observation of neutrinoless double-beta decay (0νββ) would show that lepton number is violated, reveal that neu-trinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of ~0.1 count /(FWHM·t·yr) in the region of the signal. The current generation 76 Ge experiments GERDA and the Majorana Demonstrator, utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0νββ signal region of all 0νββ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale 76 Ge experiment. Lastly, the collaboration aims to develop a phased 0νββ experimental program with discovery potential at a half-life approaching or at 10 28 years, using existing resources as appropriate to expedite physics results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of a fiber-coupled Al{sub 2}O{sub 3}:C luminescence dosimetry system for online in vivo dose verification during {sup 192}Ir brachytherapy

A prototype of a new dose-verification system has been developed to facilitate prevention and identification of dose delivery errors in remotely afterloaded brachytherapy. The system allows for automatic online in vivo dosimetry directly in the tumor region using small passive detector probes that fit into applicators such as standard needles or catheters. The system measures the absorbed dose rate (0.1 s time resolution) and total absorbed dose on the basis of radioluminescence (RL) and optically stimulated luminescence (OSL) from aluminum oxide crystals attached to optical fiber cables (1 mm outer diameter). The system was tested in the range from 0 to 4 Gy using a solid-water phantom, a Varian GammaMed Plus {sup 192}Ir PDR afterloader, and dosimetry probes inserted into stainless-steel brachytherapy needles. The calibrated system was found to be linear in the tested dose range. The reproducibility (one standard deviation) for RL and OSL measurements was 1.3%. The measured depth-dose profiles agreed well with the theoretical expectations computed with the EGSNRC Monte Carlo code, suggesting that the energy dependence for the dosimeter probes (relative to water) is less than 6% for source-to-probe distances in the range of 2-50 mm. Under certain conditions, the RL signal could be greatly disturbed by the so-called stem signal (i.e., unwanted light generated in the fiber cable upon irradiation). The OSL signal is not subject to this source of error. The tested system appears to be adequate for in vivo brachytherapy dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-channel pulsed valve inlet system and method

A multichannel inlet system for a mass spectrometer includes a plurality of valve assemblies coupled to a manifold, and a pulsed valve driver. The manifold is configured to be connected in fluid connection with an ion trap of the mass spectrometer. Each valve assembly includes a valve and an injection port operably coupled to receive the reagent. The valve has an actuated state in which the valve provides fluid communication between the injection port and the manifold, and an unactuated state in which the valve substantially prevents fluid communication between the injection port and the manifold. The pulsed valve driver is operably connected to receive a pulse signal sequence from a processor, and is configured to generate pulsed valve drive signals for one or more of the valves based on the pulse signal sequence to cause a corresponding one of the valves to be in the actuated state.

Kenttamaa, Hilkka↗

Systems and methods for monitoring organisms within an aquatic environment

Systems and methods for monitoring organisms within an aquatic environment are described. According to one aspect, an injectable acoustic transmission device includes a body configured to be injected inside of an organism, a transducer within the body and configured to convert a plurality of electrical signals into a plurality of data transmissions which are transmitted externally of the body and the organism, a plurality of circuit components within the body and configured to use electrical energy from a power source to generate the electrical signals which are provided to the transducer, and wherein the transducer defines an internal volume and at least one of the circuit components is provided within the internal volume of the transducer.

Deng, Z. Daniel↗

THE FIRST VERY LONG BASELINE INTERFEROMETRIC SETI EXPERIMENT

The first Search for Extra-Terrestrial Intelligence (SETI) conducted with very long baseline interferometry (VLBI) is presented. By consideration of the basic principles of interferometry, we show that VLBI is efficient at discriminating between SETI signals and human generated radio frequency interference (RFI). The target for this study was the star Gliese 581, thought to have two planets within its habitable zone. On 2007 June 19, Gliese 581 was observed for 8 hr at 1230-1544 MHz with the Australian Long Baseline Array. The data set was searched for signals appearing on all interferometer baselines above five times the noise limit. A total of 222 potential SETI signals were detected and by using automated data analysis techniques were ruled out as originating from the Gliese 581 system. From our results we place an upper limit of 7 MW Hz{sup -1} on the power output of any isotropic emitter located in the Gliese 581 system within this frequency range. This study shows that VLBI is ideal for targeted SETI including follow-up observations. The techniques presented are equally applicable to next-generation interferometers, such as the long baselines of the Square Kilometre Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging Domain Walls in van der Waals Ferroelectrics Using Tip-Enhanced Second Harmonic Generation

van der Waals ferroelectrics have captured significant interest for applications in novel memory and neuromorphic computing devices. Within these materials, interfaces between regions of different ferroelectric polarizations (i.e., domain walls) exhibit distinctive behaviors. Characterization of these behaviors remains a challenge, as domain wall thickness resides at the nanoscale. Using tip-enhanced second harmonic generation (TESHG), we demonstrate nanoscale imaging of domain walls in 2D ferroelectric α-In 2 Se 3 . With a narrow-band near-IR laser, we take advantage of high-wavelength, off-resonant signal enhancement to generate robust and reproducible TESHG. In conclusion, a 16 nm spatial resolution is achieved, and we identify spectral features suggesting that nonlocal effects from domain walls persist nanometers into adjacent domains.

Mantilla, Alexander B. C. [Washington State Univ.,↗

Parametric amplification of angularly multiplexed waves for application to beam smoothing

The parametric amplification of angularly multiplexed waves is studied via modeling and experiments. The phase-matching properties of the amplification process with a single pump, including parasitic interactions of pairs of signal/idler, are investigated. An experimental demonstration with up to six signal waves is presented, with a quantification of the output properties, including stability relative to the input pump and seeds. A proof-of-concept study of beam smoothing induced by combining up to 12 speckle fields generated from six signal waves and six idler waves is shown.

Dorrer, C. [University of Rochester, NY (United St↗