Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal processing algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Ultrasonic, Non-Invasive Classification/Discrimination of Liquid Explosives (LEs) and Threat Liquids from Non-Threat Liquids in Sealed Containers

Government agencies and homeland security organizations are searching for more effective approaches for dealing with the increasing demand for inspections involving potential threat liquids and hazardous chemicals, including liquid explosives (LEs). The quantity and variability of hand-held and cargo-sized containers being shipped worldwide drives the need for rapid and effective ways for conducting non-intrusive inspections of liquid-filled containers of a diverse range of types, shapes and sizes. Such inspections need to quickly classify/discriminate between liquids within containers and also ascertain the presence of unexpected objects within a container. The science base, methodology and prototype device for classification/discrimination between classes of liquids has been developed. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device for classification/discrimination of a wide variety of liquids (including threat liquids and their precursors), providing noninvasive liquid classification/discrimination capabilities using a nondestructive ultrasonic measurement approach for inspecting sealed containers. The Container Screening Device (CSD) employs frequency-modulated (FM) chirp excitation and pulse-compression signal processing techniques to measure ultrasonic velocity and a relative attenuation value for liquids within a container, and is capable of determining other acoustic properties from through-transmission, contact measurements over a wide frequency range. Recent algorithm developments are beginning to address the issues of container wall variations and thickness. A description of the basic science, measurement approach and sources of variability in the measurement will be presented and laboratory measurements acquired from a suite of commercial products and precursor liquids used in the manufacturing of Homemade Explosives (HMEs) will be given.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Solving structure with sparse, randomly-oriented x-ray data

Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing hundreds of thousands of images that contain very few x-rays. Each low-fluence image of the diffraction pattern is produced by a single, randomly oriented particle, such as a protein. We demonstrate the feasibility of recovering structural information at these extremes using low-fluence images of a randomly oriented 2D x-ray mask. Successful reconstruction is obtained with images averaging only 2.5 photons per frame, where it seems doubtful there could be information about the state of rotation, let alone the image contrast. This is accomplished with an expectation maximization algorithm that processes the low-fluence data in aggregate, and without any prior knowledge of the object or its orientation. The versatility of the method promises, more generally, to redefine what measurement scenarios can provide useful signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonance Control System for the CEBAF Separator Upgrade

Abstract The Continuous Electron Beam Accelerator Facility (CEBAF) energy upgrade from 6 GeV to 12 GeV includes the installation of four new 748.5 MHz normal conducting deflecting cavities in the 5th pass extraction region. The RF system employs two digital LLRF systems controlling four normal conducting cavities in a vector sum setting. Cavity tune information of the individual cavities is obtained using a multiplexing scheme of the forward and reflected RF signals. Water skids equipped with heaters and valves are used to control resonance. A new FPGA-based hardware and EPICS-based predictive control algorithm has been developed to support reliable operation of the beam extraction process. This paper presents the architecture design of the existing hardware and software as well as a plan to develop a model predictive control system.

Plawski, Tomasz↗

Dark Energy Survey Year 3 Results: Photometric Data Set for Cosmology

In this work, we describe the Dark Energy Survey (DES) photometric data set assembled from the first three years of science operations to support DES Year 3 cosmologic analyses, and provide usage notes aimed at the broad astrophysics community. Y3 GOLD improves on previous releases from DES, Y1 GOLD, and Data Release 1 (DES DR1), presenting an expanded and curated data set that incorporates algorithmic developments in image detrending and processing, photometric calibration, and object classification. Y3 GOLD comprises nearly 5000 deg 2 of grizY imaging in the south Galactic cap, including nearly 390 million objects, with depth reaching a signal-to-noise ratio ~10 for extended objects up to iAB ~ 23.0, and top-of-the-atmosphere photometric uniformity <3 mmag. Compared to DR1, photometric residuals with respect to Gaia are reduced by 50%, and per-object chromatic corrections are introduced. Y3 GOLD augments DES DR1 with simultaneous fits to multi-epoch photometry for more robust galactic color measurements and corresponding photometric redshift estimates. Y3 GOLD features improved morphological star–galaxy classification with efficiency >98% and purity >99% for galaxies with 19 < i AB < 22.5. Additionally, it includes per-object quality information, and accompanying maps of the footprint coverage, masked regions, imaging depth, survey conditions, and astrophysical foregrounds that are used to select the cosmologic analysis samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A parallel-pipeline architecture of the fast polynomial transform for computing a two-dimensional cyclic convolution

It is pointed out that the two-dimensional cyclic convolution is a useful tool for many two-dimensional digital signal processing applications. Two important applications are related to spaceborne high-resolution synthetic aperture radar (SAR) processing and image processing. Nussbaumer and Quandalle (1978) showed that a radix-2 polynomial transform analogous to the conventional radix-2 FFT algorithm can be used to compute a two-dimensional cyclic convolution. On the basis of results reported by Arambepola and Rayner (1979), a radix-2 polynomial transform can be defined to compute a multidimensional cyclic convolution. Truong et al. (1981) used the considered ideas together with the Chinese Theorem to further reduce the complexity of the radix-2 fast polynomial transform (FPT). Reed et al. (1981) demonstrated that such a new FPT algorithm is significantly faster than the FFT algorithm for computing a two-dimensional convolution. In the present investigation, a parallel-pipeline architecture is considered for implementing the FPT developed by Truong et al.

Truong, T. K.↗

Neuromorphic Learning From Noisy Data

Two reports present numerical study of performance of feedforward neural network trained by back-propagation algorithm in learning continuous-valued mappings from data corrupted by noise. Two types of noise considered: plant noise which affects dynamics of controlled process and data-processing noise, which occurs during analog processing and digital sampling of signals. Study performed with view toward use of neural networks as neurocontrollers to substitute for, or enhance, performances of human experts in controlling mechanical devices in presence of sensor and actuator noise and to enhance performances of more-conventional digital feedback electronic process controllers in noisy environments.

Merrill, Walter C.↗

Interferometric direction finding with a metamaterial detector

We present measurements and analysis demonstrating useful direction finding of sources in the S band (2–4 GHz) using a metamaterial detector. An augmented metamaterial absorber that supports magnitude and phase measurement of the incident electric field, within each unit cell, is described. The metamaterial is implemented in a commercial printed circuit board process with off-board back-end electronics. We also discuss on-board back-end implementation strategies. Direction finding performance is analyzed for the fabricated metamaterial detector using simulated data and the standard algorithm, MUtiple SIgnal Classification. The performance of this complete system is characterized by its angular resolution as a function of radiation density at the detector. Sources with power outputs typical of mobile communication devices can be resolved at kilometer distances with sub-degree resolution and high frame rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAPLE v.1.0

SAND2025-00659O MAPLE is a software tool that uses epigenomic data to predict gene expression. MAPLE uses a set of epigenomic modifications to determine the effect on gene expression in a specific subset of species. The algorithm can be trained on additional species and epigenomic modifications, enhancing its predictive capabilities. EAGLE employs a hybrid neural network architecture, featuring a convolutional front-end and a multi-head attention layer, to process pre-processed signal data as input. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Davis IV, Warren↗

Concepts for on board satellite image registration. Volume 4: Impact of data set selection on satellite on board signal processing

The NASA NEEDS program goals present a requirement for on-board signal processing to achieve user-compatible, information-adaptive data acquisition. This volume addresses the impact of data set selection on data formatting required for efficient telemetering of the acquired satellite sensor data. More specifically, the FILE algorithm developed by Martin-Marietta provides a means for the determination of those pixels from the data stream effects an improvement in the achievable system throughput. It will be seen that based on the lack of statistical stationarity in cloud cover, spatial distribution periods exist where data acquisition rates exceed the throughput capability. The study therefore addresses various approaches to data compression and truncation as applicable to this sensor mission.

Ruedger, W. H.↗

Discrimination against interfering signals at the Poker Flat MST radar

Several on line and off line data processing techniques are used to remove interfering signals due to ground clutter, aircraft, instrumental effects, and external transmissions from the desired atmospheric echoes of Mesosphere Stratosphere, Troposphere (MST) radar. The on line, real time techniques are necessarily simple in order to minimize processing delays. This algorithm examines the individual Doppler spectra which are computed every two to four seconds (for oblique antenna beams). The total spectral power in each individual spectrum is computed by summing all the spectral points. If this integrated power increases from one spectrum to the next by a factor greater than a preselected threshold, then that spectrum is not added to the spectral sum. Succeeding spectra are compared to the last acceptable spectrum. Only a certain maximum number of spectra are allowed to be rejected in succession.

Carter, D. A.↗

Magellan radar to reveal secrets of enshrouded Venus

Imaging Venus with a synthetic aperture radar (SAR) with 70 percent global coverage at 1-km optical line-pair resolution to provide a detailed global characterization of the volcanic land-forms on Venus by an integration of image data with altimetry is discussed. The Magellan radar system uses navigation predictions to preset the radar data collection parameters. The data are collected in such a way as to preserve the Doppler signature of surface elements and later they are transmitted to the earth for processing into high-resolution radar images. To maintain high accuracy, a complex on-board filter algorithm allows the altitude control logic to respond only to a narrow range of expected photon intensity levels and only to signals that occur within a small predicted interval of time. Each mapping pass images a swath of the planet that varies in width from 20 to 25 km. Since the orbital plane of the spacecraft remains fixed in the inertial space, the slow rotation of Venus continually brings new areas into view of the spacecraft.

Saunders, R. Stephen↗

Transiting Planet Search in the Kepler Pipeline

The Kepler Mission simultaneously measures the brightness of more than 160,000 stars every 29.4 minutes over a 3.5-year mission to search for transiting planets. Detecting transits is a signal-detection problem where the signal of interest is a periodic pulse train and the predominant noise source is non-white, non-stationary (1/f) type process of stellar variability. Many stars also exhibit coherent or quasi-coherent oscillations. The detection algorithm first identifies and removes strong oscillations followed by an adaptive, wavelet-based matched filter. We discuss how we obtain super-resolution detection statistics and the effectiveness of the algorithm for Kepler flight data.

Jenkins, Jon M.↗

Implementation of an Analytical Raman Scattering Correction for Satellite Ocean-Color Processing

Raman scattering of photons by seawater molecules is an inelastic scattering process. This effect can contribute significantly to the water-leaving radiance signal observed by space-borne ocean-color spectroradiometers. If not accounted for during ocean-color processing, Raman scattering can cause biases in derived inherent optical properties (IOPs). Here we describe a Raman scattering correction (RSC) algorithm that has been integrated within NASA's standard ocean-color processing software. We tested the RSC with NASA's Generalized Inherent Optical Properties algorithm (GIOP). A comparison between derived IOPs and in situ data revealed that the magnitude of the derived backscattering coefficient and the phytoplankton absorption coefficient were reduced when the RSC was applied, whilst the absorption coefficient of colored dissolved and detrital matter remained unchanged. Importantly, our results show that the RSC did not degrade the retrieval skill of the GIOP. In addition, a timeseries study of oligotrophic waters near Bermuda showed that the RSC did not introduce unwanted temporal trends or artifacts into derived IOPs.

SeaDAS↗

Smart sensor for online situational awareness in power grids

Waveforms in power grids typically reveal a certain pattern with specific features and peculiarities driven by the system operating conditions, internal and external uncertainties, etc. This prompts an observation of different types of waveforms at the measurement points (substations). An innovative next-generation smart sensor technology includes a measurement unit embedded with sophisticated analytics for power grid online surveillance and situational awareness. The smart sensor brings additional levels of smartness into the existing phasor measurement units (PMUs) and intelligent electronic devices (IEDs). It unlocks the full potential of advanced signal processing and machine learning for online power grid monitoring in a distributed paradigm. Within the smart sensor are several interconnected units for signal acquisition, feature extraction, machine learning-based event detection, and a suite of multiple measurement algorithms where the best-fit algorithm is selected in real-time based on the detected operating condition. Embedding such analytics within the sensors and closer to where the data is generated, the distributed intelligence mechanism mitigates the potential risks to communication failures and latencies, as well as malicious cyber threats, which would otherwise compromise the trustworthiness of the end-use applications in distant control centers. The smart sensor achieves a promising classification accuracy on multiple classes of prevailing conditions in the power grid and accordingly improves the measurement quality across the power grid.

Dehghanian, Payman↗

Poisson Log-Normal Process for Count Data Prediction

Modeling count data is important in physics and other scientific disciplines, where measurements often involve discrete, non-negative quantities such as photon or neutrino detection events. Traditional parametric approaches can be trained to generate integer-count predictions but may struggle with capturing complex, non-linear dependencies often observed in the data. Gaussian process (GP) regression provides a robust non-parametric alternative to modeling continuous data; however, it cannot generate integer outputs. We propose the Poisson Log-Normal (PoLoN) process, a framework that employs GP to model Poisson log-rates. As in GP regression, our approach relies on the correlations between data points captured via GP kernel structure rather than explicit functional parameterizations. We demonstrate that the PoLoN predictive distribution is Poisson-LogNormal and provide an algorithm for optimizing kernel hyperparameters. Furthermore, we adapt the PoLoN approach to the problem of detecting weak localized signals superimposed on a smoothly varying background - a task of considerable interest in many areas of science and engineering. Our framework allows us to predict the strength, location and width of the detected signals. We evaluate PoLoN's performance using both synthetic and real-world datasets, including the open dataset from CERN which was used to detect the Higgs boson at the Large Hadron Collider. Our results indicate that the PoLoN process can be used as a non-parametric alternative for analyzing, predicting, and extracting signals from integer-valued data.

Saha, Anushka [Rutgers U., Piscataway]↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗