Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small angle scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Analysis of textural properties of CaO-based CO 2 sorbents by ex-situ USAXS

Here in this work, the micro-textural properties of CaO-based CO 2 sorbents prepared in a thermo-gravimetric reactor were investigated by ex situ synchrotron-based Small Angle X-ray Scattering (SAXS), Ultra Small Angle X-ray Scattering (USAXS) and Wide Angle X-ray Scattering (WAXS). Six sorbent samples were produced by calcination in vacuum at different temperatures and durations of the heating step; additionally, four partially carbonated samples were produced, after calcination in vacuum, at different CaO conversions. The scattering intensity profiles were analyzed by means of the Unified Fit model. Bimodal pore size distributions (micro-pores and meso-pores) were identified and the micro-textural properties (porosity, specific surface and pore radius of gyration) of each of the two pore populations were quantified both for the calcined and for the carbonated samples. The micro-textural properties of a few calcined samples were compared with N 2 -adsorption measurements. For each pore population, the trends of porosity, specific surface and pore radius of gyration, in addition to the pore number density and sphericity factor, were obtained versus time during the calcination and versus the CaO conversion during the carbonation. The relevance of micro-pores with respect to macro-pores was assessed both as far as the porosity impact on the CO 2 capture capacity and as far as the specific surface impact on the carbonation kinetics. For the calcined samples, the micro-textural properties of a partially calcined sample were compared with those of the completely calcined samples, and pore correlation distances were determined. Finally, for the carbonated samples, the specific surface per unit of particle volume results linearly dependent on the CaO conversion and, if expressed per unit of mass of unreacted CaO, does not change significantly for most of the CaO carbonation.

36 MATERIALS SCIENCE↗

Alteration of water structure by peptide clusters revealed by neutron scattering in the small-angle region (below 1 Å –1 )

Solution scattering of neutrons and x-rays can provide direct information on local interactions of importance for biomolecular folding and structure. Here, neutron scattering experiments are combined with molecular-dynamics simulation to interpret the scattering signal of a series of dipeptides with varying degrees of hydrophobicity (GlyAla, GlyPro, and AlaPro) in concentrated aqueous solution (1:20 solute/water ratio) in which the peptides form large segregates (up to 50 60 amino acids). Two main results are found: 1), the shift to lower Q of the so-called water-ring peak (Q ≈ 2Å –1 ) arises mainly from an overlap of water-peptide and peptide-peptide correlations in the region of 1.3 < Q < 2Å –1 , rather than from a shift of the water signal induced by the presence of the clusters; and 2), in the low-Q region (Q ≈ 0.6Å –1 ) a positive peak is observed originating from both the solute-solute correlations and changes in the water structure induced by the formation of the clusters. In particular, the water molecules are found to be more connected than in the bulk with hydrogen-bonding directions tangential to the exposed hydrophobic surfaces, and this effect increases with increasing peptide hydrophobicity. Lastly, this work demonstrates that important information on the (hydrophobic) hydration of biomolecules can be obtained in the very-small-angle region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Universally Accessible Structural Data on Macromolecular Conformation, Assembly, and Dynamics by Small Angle X-Ray Scattering for DNA Repair Insights.

Structures provide a critical breakthrough step for biological analyses, and small angle X-ray scattering (SAXS) is a powerful structural technique to study dynamic DNA repair proteins. As toxic and mutagenic repair intermediates need to be prevented from inadvertently harming the cell, DNA repair proteins often chaperone these intermediates through dynamic conformations, coordinated assemblies, and allosteric regulation. By measuring structural conformations in solution for both proteins, DNA, RNA, and their complexes, SAXS provides insight into initial DNA damage recognition, mechanisms for validation of their substrate, and pathway regulation. Here, we describe exemplary SAXS analyses of a DNA damage response protein spanning from what can be derived directly from the data to obtaining super resolution through the use of SAXS selection of atomic models. We outline strategies and tactics for practical SAXS data collection and analysis. Making these structural experiments in reach of any basic and clinical researchers who have protein, SAXS data can readily be collected at government-funded synchrotrons, typically at no cost for academic researchers. In addition to discussing how SAXS complements and enhances cryo-electron microscopy, X-ray crystallography, NMR, and computational modeling, we furthermore discuss taking advantage of recent advances in protein structure prediction in combination with SAXS analysis.

Chinnam, Naga Babu↗

Ultra-small-angle x-ray scattering at the Advanced Photon Source.

The design and operation of a versatile ultra-small-angle X-ray scattering (USAXS) instrument at the Advanced Photon Source (APS) at Argonne National Laboratory are presented. The instrument is optimized for the high brilliance and low emittance of an APS undulator source. It has angular and energy resolutions of the order of 10{sup -4}, accurate and repeatable X-ray energy tunability over its operational energy range from 8 to 18 keV, and a dynamic intensity range of 10{sup 8} to 10{sup 9}, depending on the configuration. It further offers quantitative primary calibration of X-ray scattering cross sections, a scattering vector range from 0.0001 to 1 {angstrom}{sup -1}, and stability and reliability over extended running periods. Its operational configurations include one-dimensional collimated (slit-smeared) USAXS, two-dimensional collimated USAXS and USAXS imaging. A robust data reduction and data analysis package, which was developed in parallel with the instrument, is available and supported at the APS.

43 PARTICLE ACCELERATORS↗

Ultra-small-angle X-ray scattering study of second- phase particles in heat-treated Zircaloy-4

The ultra-small-angle X-ray scattering (USAXS) technique has been used to investigate and to quantify the morphology and size distribution of secondphase particles in Zircaloy-4 under various heat-treatment conditions. The alloy samples were solutionized in the phase field at 1293 K for 15 min and then cooled at different rates, including water quenching, air cooling and furnace cooling. The water-quenched samples were subsequently subjected to a thermal aging treatment at 873 K for different aging times (30, 60, 120 and 300 min). The USAXS results show that water quenching and air cooling from the phase field produces a narrow size distribution of fine-size precipitates with an average diameter of 300–800 A ° , while furnace cooling resulted in coarsening of the particles, with a broad size distribution having an average precipitate size of 600–1200 A ° . Further, the furnace-cooled sample shows a higher volume fraction of particles than the water-quenched or air-cooled sample. The USAXS results on the quenched then aged samples show that aging at 873 K for 10 min resulted in very fine size precipitates with an average diameter of 200–350 A ° . A rapid precipitation with the highest number density of second-phase particles amongst all the heat-treated samples (4.3 1020 m3) was observed in the sample aged for 10 min at 873 K. Particles of larger size and with a broad size distribution were observed in the sample aged at 873 K for 300 min. A bimodal type of particle size distribution was observed in all the heat-treated samples. Important parameters in the characterization of second-phase particles, such as the average size, size distribution, volume fraction and number density, were evaluated and quantified. These parameters are discussed for both heat-treated and aged specimens. Transmission and scanning transmission electron microscopy characterization were carried out on all heat-treated samples, to assist in interpretation and to substantiate the results from the USAXS measurements.

Srirangam, Prakash↗

Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2 ( q ) = [ I ( q ) + const.]/( kq ), where I ( q ) is the scattering intensity as a function of the momentum transfer q ; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture of a Full-length Retroviral Integrase Monomer and Dimer, Revealed by Small Angle X-ray Scattering and Chemical Cross-linking

We determined the size and shape of full-length avian sarcoma virus (ASV) integrase (IN) monomers and dimers in solution using small angle x-ray scattering. The low resolution data obtained establish constraints for the relative arrangements of the three component domains in both forms. Domain organization within the small angle x-ray envelopes was determined by combining available atomic resolution data for individual domains with results from cross-linking coupled with mass spectrometry. The full-length dimer architecture so revealed is unequivocally different from that proposed from x-ray crystallographic analyses of two-domain fragments, in which interactions between the catalytic core domains play a prominent role. Core-core interactions are detected only in cross-linked IN tetramers and are required for concerted integration. The solution dimer is stabilized by C-terminal domain (CTD-CTD) interactions and by interactions of the N-terminal domain in one subunit with the core and CTD in the second subunit. These results suggest a pathway for formation of functional IN-DNA complexes that has not previously been considered and possible strategies for preventing such assembly.

59 BASIC BIOLOGICAL SCIENCES↗

Identifying Topological Defects in Lamellar Phases through Contour Analysis of Complex Wave Fields

Lamellar phases frequently contain structural imperfections that significantly affect their behaviors and properties. Our previous research successfully reconstructed real-space configurations of defective lamellar phases from diffuse scattering patterns, indicating the presence of phase vortices as a potential method for identifying topological defects disrupting the smectic ordering. Here, this report presents a mathematical framework using regularized wave fields to represent defective lamellar structures in real space. Phase singularities, resulting from the interference of random waves and indicating lamellar order disruption, are identified through a contour integral. These wave fields, derived from coherent scattering in reciprocal space, were validated via computational benchmarks analyzing small-angle neutron scattering data from AOT surfactant solutions, facilitating further statistical analysis of the defects. Our study highlights the potential to extract meaningful information about topological defects in lyotropic phases by inversely analyzing experimentally measured two-point static correlations. Our method allows for detailed structural analysis of various lyotropic phases, both particulate and nonparticulate, in their quiescent states and facilitates quantitative investigation of defects’ role in phase transitions. By integrating small-angle scattering, deep learning, and vortex tangle analysis, our comprehensive approach shows promise in addressing complex challenges in the structural analysis of soft matter systems.

36 MATERIALS SCIENCE↗

Micellar Surfactant Association in the Presence of a Glucoside-based Amphiphile Detected via High-Throughput Small Angle X-ray Scattering

The interactions of mixtures of anionic and amphoteric surfactants with sugar amphiphiles were studied via high throughput small angle x-ray scattering (SAXS). The sugar amphiphile was composed of Caprate, Caprylate, and Oleate mixed ester of methyl glucoside, MeGCCO. Optimal surfactant interactions are sought which have desirable physical properties, which must be identified in a cost effective manner that can access the large phase space of possible molecular combinations. X-ray scattering patterns obtained via high throughput SAXS can probe a combinatorial sample space and reveal the incorporation of MeGCCO into the micelles and the molecular associations between surfactant molecules. Such data make it possible to efficiently assess the effects of the new amphiphiles in the formulation. A specific finding of this study is that formulations containing comparatively monodisperse and homogeneous surfactant mixtures can be reliably tuned by addition of NaCl, which swells the surfactant micelles with a monotonic dependence on salt concentration. In contrast, the presence of multiple different surfactants destroys clear correlations with NaCl concentration, even in otherwise similar series of formulations.

36 MATERIALS SCIENCE↗

Small angle x-ray scattering with a beryllium compound refractive lens as focusing optic

At BW4 at HASYLAB a beryllium compound refractive lens (Be-CRL) is used for the focusing in small-angle x-ray scattering experiments. Using it provides the advantages of higher long-term stability and a much easier alignment compared to a setup with focusing mirrors. In our investigations presented here, we show the advantages of using a Be-CRL in small-angle and also ultra small-angle x-ray scattering. We investigated the beam characteristics at the sample position with respect to spot size and photon flux. The spot size is comparable to that of a setup with focusing mirrors but with a gain in flux and better long-term stability. It is also shown that plane mirrors are still necessary to suppress higher order energies passing the monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron scattering measurement of water content and chemical composition of alkali-glass powder reacted gel

Highlights: • Water absorption ability of alkali-glass powder reacted gel was largely reduced comparing other reported alkali-silica gels. • Both SAXS and SANS results showed similar internal structures of samples prepared with different H2O:D2O mixing ratios. • Neutron scattering method was developed to non-destructively determine gel water content and mass density of reacted gels. • Neutron scattering methods (based on scattering length density) on gel water content was validated with TGA measurement. - Abstract: Recent studies demonstrated that the added glass powder with high-alumina content could significantly reduce Alkali-Silica Reaction (ASR) damage in cement concrete. This paper aims to investigate the gel water content, chemical composition and expansion behavior of the alkali-glass powder reacted gel by using neutron scattering and other characterization techniques. Three types of samples were prepared with glass powder, sodium oxide and deuteroxide/hydrogen water with different molar ratios. The swelling potential of this alkali-glass powder reacted gel was much lower than that of the reported alkali-silica reacted gel. The gel water content and chemical compositions were characterized with small-angle neutron scattering (SANS) technique, supported by small-angle X-ray scattering (SAXS), prompt-gamma ray neutron activation analysis (PGAA) measurement. The SAXS test results showed the close scattering intensities, and thus similar internal microstructures among these samples. The elemental molar ratios of gels were obtained from the PGAA test results. Then the gel water molar ratio and mass density were determined by neutron scattering contrast calculation. The determined gel water content from neutron scattering analysis was validated with zero contrast analysis and TGA experimental measurement. Overall, this paper demonstrated the feasibility of using SANS technique to determine the water content of alkali-glass powder reacted gel.

36 MATERIALS SCIENCE↗

Understanding Solution State Conformation and Aggregate Structure of Conjugated Polymers via Small Angle X-ray Scattering

Donor-acceptor (D-A) conjugated polymers are high-performance organic electronic materials that exhibit complex aggregation behavior. Understanding the solution state conformation and aggregation of conjugated polymers is crucial for controlling morphology during thin-film deposition and the subsequent electronic performance. However, a precise multiscale structure of solution state aggregates is lacking. Here, we present an in-depth small-angle X-ray scattering (SAXS) analysis of the solution state structure of an isoindigo-bithiophene-based D-A polymer (PII-2T) in chlorobenzene and decane as our primary system. Modeling the system as a combination of hierarchical fibrillar aggregates mixed with dispersed polymers, we extract information about conformation and multiscale aggregation and also clarify the physical origin of features often observed but unaddressed or misinterpreted in small-angle scattering patterns of conjugated polymers. The persistence length of the D-A polymer extracted from SAXS agrees well with a theoretical model based on the dihedral potentials. Additionally, we show that the broad high q structure factor peak seen in scattering profiles can be attributed to lamellar stacking occurring within the fibril aggregates and that the low q aggregate scattering is strongly influenced by the polymer molecular weight. Overall, the SAXS profiles of D-A polymers in general exhibit a sensitive dependence on the co-existence of fibrillar aggregate and dispersed polymer chain populations. We corroborate our findings from SAXS with electron microscopy of freeze-dried samples for direct imaging of fibrillar aggregates. Finally, we demonstrate the generality of our approach by fitting the scattering profiles of a variety of D-A polymers based on thieno-isoindigo (PTII-2T), diketopyrrolopyrrole (DPP2T-TT, DPP-BTZ, PDPP2FT-C- 16 ), naphthalenediimide (P(NDI2OD-T2)), and a conjugated block copolymer P3HT-b-DPPT-T. The results presented here establish a picture of the D-A polymer solution state structure and provide a general method of interpreting and analyzing their scattering profiles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface layer protein characterization by small angle x-ray scattering and a fractal mean force concept: From protein structure to nanodisk assemblies

Surface layers (S-layers) are the most commonly observed cell surface structure of prokaryotic organisms. They are made up of proteins that spontaneously self-assemble into functional crystalline lattices in solution, on various solid surfaces, and interfaces. While classical experimental techniques failed to recover a complete structural model of an unmodified S-layer protein, small angle x-ray scattering (SAXS) provides an opportunity to study the structure of S-layer monomers in solution and of self-assembled two-dimensional sheets. For the protein under investigation we recently suggested an atomistic structural model by the use of molecular dynamics simulations. This structural model is now refined on the basis of SAXS data together with a fractal assembly approach. Here we show that a nondiluted critical system of proteins, which crystallize into monomolecular structures, might be analyzed by SAXS if protein-protein interactions are taken into account by relating a fractal local density distribution to a fractal local mean potential, which has to fulfill the Poisson equation. The present work demonstrates an important step into the elucidation of the structure of S-layers and offers a tool to analyze the structure of self-assembling systems in solution by means of SAXS and computer simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrahigh vacuum/high-pressure flow reactor for surface x-ray diffraction and grazing incidence small angle x-ray scattering studies close to conditions for industrial catalysis

A versatile instrument for the in situ study of catalyst surfaces by surface x-ray diffraction and grazing incidence small angle x-ray scattering in a 13 ml flow reactor combined with reaction product analysis by mass spectrometry has been developed. The instrument bridges the so-called ''pressure gap'' and ''materials gap'' at the same time, within one experimental setup. It allows for the preparation and study of catalytically active single crystal surfaces and is also equipped with an evaporator for the deposition of thin, pure metal films, necessary for the formation of small metal particles on oxide supports. Reactions can be studied in flow mode and batch mode in a pressure range of 100-1200 mbar and temperatures up to 950 K. The setup provides a unique combination of sample preparation, characterization, and in situ experiments where the structure and reactivity of both single crystals and supported nanoparticles can be simultaneously determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the structure of unilamellar dimyristoylphosphatidylcholine vesicles in aqueous sucrose solutions by small-angle neutron and X-ray scattering

The structure of a polydispersed population of unilamellar dimyristoylphosphatidylcholine (DMPC) vesicles in sucrose solutions has been investigated by small-angle neutron scattering (SANS) and small-angle X-ray scattering (SAXS). Calculations within the model of separated form factors (SFF) show that the structure of the vesicle system depends strongly on the sucrose concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of the fundamental theories behind small angle X-ray scattering, molecular dynamics simulations, and relevant integrated application

In this paper, the fundamental concepts and equations necessary for performing small angle X-ray scattering (SAXS) experiments, molecular dynamics (MD) simulations, and MDSAXS analyses were reviewed. Furthermore, several key biological and non-biological applications for SAXS, MD, and MD-SAXS are presented in this review; however, this article does not cover all possible applications. SAXS is an experimental technique used for the analysis of a wide variety of biological and non-biological structures. SAXS utilizes spherical averaging to produce one- or two-dimensional intensity profiles, from which structural data may be extracted. MD simulation is a computer simulation technique that is used to model complex biological and non-biological systems at the atomic level. MD simulations apply classical Newtonian mechanics’ equations of motion to perform force calculations and to predict the theoretical physical properties of the system. This review presents several applications that highlight the ability of both SAXS and MD to study protein folding and function in addition to non-biological applications, such as the study of mechanical, electrical, and structural properties of non-biological nanoparticles. Lastly, the potential benefits of combining SAXS and MD simulations for the study of both biological and non-biological systems are demonstrated through the presentation of several examples that combine the two techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Corona Block Length on the Structure and Chain Exchange Kinetics of Block Copolymer Micelles

The effect of corona block length on micelle structure and molecular chain exchange kinetics has been investigated for a series of dilute poly(styrene)-b-poly(ethylene-alt-propylene) (SEP) diblock copolymer micelles with constant PS core block length ($\langle$N core $\rangle$ ≈ 255) but different PEP corona block lengths (($\langle$N corona $\rangle$ = 256–2080), using a combination of dynamic light scattering (DLS), small-angle X-ray scattering (SAXS), and time-resolved small-angle neutron scattering (TR-SANS). Smaller core radii and aggregation numbers, but significantly thicker corona layers (proportional to N corona 0.7 ), were observed with increasing corona block length. Furthermore, 2 orders of magnitude more rapid chain exchange was observed in SEP micelles with the longest corona block compared to the shortest. This effect is attributed to the entropic gain arising from the relief of corona chain stretching upon chain expulsion. We further extend a previous theoretical model by explicitly including a corona term associated with the entropy change in the chain exchange process, which successfully explains the influence of the corona blocks on chain exchange. Our results are in excellent agreement with simulation results of Li and Dormidontova but are apparently contradictory with Halperin and Alexander’s theory for hairy micelles and with experimental observations in two other systems that the exchange kinetics slow down with increasing corona block length. These discrepancies reveal unanticipated complexity regarding the role of the corona block in chain exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controls of Microstructure and Chemical Reactivity on the Replacement of Limestone by Fluorite Studied Using Spatially Resolved Small Angle X-ray and Neutron Scattering

Fluid-mineral interactions can alter the pore structure and mineral composition of earth materials, sometimes leading to complete replacement of one mineral phase by another. A quantitative understanding of these processes is needed for the prediction of contaminant transport in nuclear waste management, oil and gas exploration, geothermal energy production and in many geological processes. Currently, a detailed understanding of how the original microstructure and chemical reactivity is affecting the replacement rate and porosity development is lacking which would enable the prediction of contaminant transport. Here, we present a systematic experimental study of limestone replacement in the model system calcite-fluorite varying both the texture and chemical reactivity of the parent rock. By combining X-ray ((U)SAXS) and neutron (ultra) small-angle scattering ((U)SANS) we quantified changes in the porosity as a function of depth within the sample and time. By shielding the samples with a set of annular Cd-masks during neutron scattering, we obtained spatially-resolved porosity information. Microstructural changes were investigated using scanning electron microscopy (SEM), and composition changes were accessed using chemical imaging by Time-of-Flight Secondary Ion Mass Spectrometry (ToF—SIMS) and SEM-Energy-Dispersive X-Ray Spectroscopy (SEM-EDX). The replacement of limestone via fluorite takes place via advantageous pathways enhancing the available reactive surface area, e.g. fractures, accessible, interconnected porosity, non-connected porosity grain boundaries and twin boundaries. The results presented in this paper emphasize the importance of a detailed structural and textural assessment of the starting material both in experimental studies and in nature to make accurate predictions about reaction rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗