Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software estimation,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

xsaprrhi (a1)

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

54 ENVIRONMENTAL SCIENCES↗

xsaprppi (a1)

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

54 ENVIRONMENTAL SCIENCES↗

xsaprhsrhi (00)

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

54 ENVIRONMENTAL SCIENCES↗

xsaprppi (00)

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

54 ENVIRONMENTAL SCIENCES↗

X-Band Scanning ARM Precipitation Radar, CF/Radial Formatted, Quality Controlled

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

xsaprcfrqc↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PyPop: a mature open-source software pipeline for population genomics

Python for Population Genomics (PyPop) is a software package that processes genotype and allele data and performs large-scale population genetic analyses on highly polymorphic multi-locus genotype data. In particular, PyPop tests data conformity to Hardy-Weinberg equilibrium expectations, performs Ewens-Watterson tests for selection, estimates haplotype frequencies, measures linkage disequilibrium, and tests significance. Standardized means of performing these tests is key for contemporary studies of evolutionary biology and population genetics, and these tests are central to genetic studies of disease association as well. Here, we present PyPop 1.0.0, a new major release of the package, which implements new features using the more robust infrastructure of GitHub, and is distributed via the industry-standard Python Package Index. New features include implementation of the asymmetric linkage disequilibrium measures and, of particular interest to the immunogenetics research communities, support for modern nomenclature, including colon-delimited allele names, and improvements to meta-analysis features for aggregating outputs for multiple populations.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of tritium transport in a gas-liquid contactor CFD simulation of tritium extraction from lead-lithium in ANSYS fluent

Modifications to the Computational Fluid Dynamic (CFD) software ANSYS Fluent were done to quantify and characterize tritium transport in Gas-Liquid Contactors (GLCs). A double-slit, Ergun-like equation was employed for the porous media model, with Ergun coefficients validated with Sulzer’s Sulcol software. Tritium transport from PbLi within the GLC was verified against analytical models. The geometry of the CFD model was based on the MELODIE GLC experiment. The hydrodynamic CFD pressure drop results align well with SulCol estimations and fall between the predictions of the analytical Delft-Olujic and Billet & Schultes models. In terms of mass transfer efficiency, traditional mass transfer models showed a significant deviation from experimental results when using varying values of H solubility in PbLi. A saturation phenomenon occurred when utilizing high solubility values for hydrogen in PbLi. In conclusion, a modified film theory mass transfer coefficient, incorporating either the Delft-Olujic or Billet & Schultes wettability model, yielded CFD-predicted extraction efficiencies that closely matched experimental measurements.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular dynamics study of mechanical properties of carbon nanotube reinforced aluminum composites

Atomistic simulations were conducted to estimate the effect of the carbon nanotube (CNT) reinforcement on the mechanical behavior of CNT-reinforced aluminum (Al) nanocomposite. The periodic system of CNT-Al nanocomposite was built and simulated using molecular dynamics (MD) software LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator). The mechanical properties of the nanocomposite were investigated by the application of uniaxial load on one end of the representative volume element (RVE) and fixing the other end. The interactions between the atoms of Al were modeled using embedded atom method (EAM) potentials, whereas Adaptive Intermolecular Reactive Empirical Bond Order (AIREBO) potential was used for the interactions among carbon atoms and these pair potentials are coupled with the Lennard-Jones (LJ) potential. The results show that the incorporation of CNT into the Al matrix can increase the Young’s modulus of the nanocomposite substantially. In the present case, i.e. for approximately 9 with % reinforcement of CNT can increase the axial Young’s modulus of the Al matrix up to 77 % as compared to pure Al.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-80: A Comparative Analysis of MIM and Pinnacle Software for Adaptive Planning

Purpose: IMRT treatment is often administered with image guidance and small PTV margins. Change in body habitus such as weight loss and tumor response during the course of a treatment could be significant, thus warranting re-simulation and re-planning. Adaptive planning is challenging and places significant burden on the staff, as such some commercial vendors are now offering adaptive planning software to stream line the process of re-planning and dose accumulation between different CT data set. The purpose of this abstract is to compare the adaptive planning tools between Pinnacle version 9.8 and MIM 6.4 software. Methods: Head and Neck cases of previously treated patients that experienced anatomical changes during the course of their treatment were chosen for evaluation. The new CT data set from the re-simulation was imported to Pinnacle and MIM software. The dynamic planning tool in pinnacle was used to calculate the old plan with fixed MU setting on the new CT data. In MIM, the old CT was registered to the new data set, followed by a dose transformation to the new CT. The dose distribution to the PTV and critical structures from each software were analyzed and compared. Results: 9% difference was observed between the Global maximum doses reported by both software. Mean doses to organs at risk and PTV’s were within 6 % however pinnacle showed greater difference in PTV coverage change. Conclusion: MIM software adaptive planning corrects for geometrical changes without consideration for the effect of radiological path length on dose distribution; however Pinnacle corrects for both geometric and radiological effect on the dose distribution. Pinnacle gives a better estimate of the dosimetric impact due to anatomical changes.

60 APPLIED LIFE SCIENCES↗

BCS (CSP Beam Characterization System) [SWR-23-13]

The Beam Characterization System (BCS) is an image-processing tool for estimating heliostat tracking errors. A large mirror, or heliostat, reflects the sun onto a distant target. A carefully calibrated camera then takes an image of this target to capture the shape of the reflected beam. The software kit hosts a series of scripts to identify key features and run analysis on the captured images.

Kesseli, Devon↗

Ocean Thermal Extractable Energy Visualization (Final Technical Report)

The Ocean Thermal Extractable Energy Visualization (OTEEV) project focuses on assessing the Maximum Practicably Extractable Energy (MPEE) from the world's ocean thermal resources. MPEE is defined as being sustainable and technically feasible, given today's state-of-the-art ocean energy technology. Under this project the OTEEV team developed a comprehensive Geospatial Information System (GIS) dataset and software tool, and used the tool to provide a meaningful assessment of MPEE from the global and domestic U.S. ocean thermal resources. The OTEEV project leverages existing NREL renewable energy GIS technologies and integrates extractable energy estimated from quality-controlled data and projected optimal achievable energy conversion rates. Input data are synthesized from a broad range of existing in-situ measurements and ground-truthed numerical models with temporal and spatial resolutions sufficient to reflect the local resource. Energy production rates are calculated for regions based on conversion rates estimated for current technology, local energy density of the resource, and sustainable resource extraction. Plant spacing and maximum production rates are then estimated based on a default plant size and transmission mechanisms. The resulting data are organized, displayed, and accessed using a multi-layered GIS mapping tool, http://maps.nrel.gov/mhk_atlas with a user-friendly graphical user interface.

14 SOLAR ENERGY↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

LIP: The Livermore Interpolation Package, Version 1.3

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the ''LEOS Interpolation Package''. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a ''LIP interpolation object'' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as ''partial setup'' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

LIP: The Livermore Interpolation Package, Version 1.4

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the 'LEOS Interpolation Package'. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a 'LIP interpolation object' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as 'partial setup' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

Save Energy Now Assessments Results 2008 Summary Report

In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments is $1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy Now assessments completed to date. A separate report (Wright et al. 2010) provides more detailed information on key results for all of the 2008 assessments of steam, process heating, pumping, compressed air, and fan systems. Two prior reports (Wright et al. 2007 and Wright et al. 2009) detail the results from the 2006 and 2007 assessments and discuss the major components of the assessment process and improvements in the process made in 2007.

03 NATURAL GAS↗