Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Unveiling the Role of In Situ Al 2 O 3 Passivation in Molecular-Ink-Processed CuIn(S,Se) 2 Photovoltaics

Here, we report on the optimization of in situ passivation of ink-based CuIn(S,Se) 2 thin-film solar cells via controlled incorporation of Al 2 O 3 in CuIn(S,Se) 2 films by the addition of Al(NO 3 ) 3 to the molecular ink precursor. For this purpose, the Al/(Al + In) (AAI) metal ratio was varied from 0.05 to 0.30. We observe that the efficiency of the cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 is consistently higher than those without Al 2 O 3 , especially due to an improvement in open-circuit voltage (V OC ) and fill factor (FF), for all tested AAI ratios. With an AAI of 0.05, a maximum efficiency of 11.2% and an average efficiency of 8.5% (measured across 18 cells) was achieved, compared to 8.5% maximum efficiency and 6.5% average efficiency for Al-free CuIn(S,Se) 2 . Furthermore, we find that cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 with an AAI of 0.2 show a narrow distribution in the photovoltaic performance, indicating higher reproducibility and higher FF. Energy-dispersive X-ray spectroscopy shows that, at AAI = 0.2, Al 2 O 3 is distributed more homogeneously at the surface of the Al 2 O 3 -incorporated CISSe. Capacitance-voltage measurements reveal a reduced defect density by incorporation of Al 2 O 3 , which could be partly responsible for the higher V OC . Furthermore, using detailed surface analysis with various X-ray and electron spectroscopy methods, we derive chemical and electronic structure information from the surface. With ultraviolet photoelectron (UPS) and inverse photoemission spectroscopies (IPES), the electronic band gap of the CuIn(S,Se) 2 thin-film surface is found to increase from 1.22 to 1.88 eV (+-0.12 eV) with Al 2 O 3 incorporation. This is accompanied by a clear reduction of the conduction band spike at the CdS/CISSe interface due to Al 2 O 3 addition, as derived by both UPS and IPES as well as temperature-dependent V OC measurements.

14 SOLAR ENERGY↗

Cleaning Genesis Mission Payload for Flight with Ultra-Pure Water and Assembly in ISO Class 4 Environment

Genesis mission to capture and return to Earth solar wind samples had very stringent contamination control requirements in order to distinguish the solar atoms from terrestrial ones. Genesis mission goals were to measure solar composition for most of the periodic table, so great care was taken to avoid particulate contamination. Since the number 1 and 2 science goals were to determine the oxygen and nitrogen isotopic composition, organic contamination was minimized by tightly controlling offgassing. The total amount of solar material captured in two years is about 400 micrograms spread across one sq m. The contamination limit requirement for each of C, N, and O was <1015 atoms/sq cm. For carbon, this is equivalent to 10 ng/cm2. Extreme vigilance was used in pre-paring Genesis collectors and cleaning hardware for flight. Surface contamination on polished silicon wafers, measured in Genesis laboratory is approximately 10 ng/sq cm.

Allton, Judith H.↗

Advocating for view and daylight in buildings: Next steps

With the exponential growth in population and commensurate increased density in urban cities, access to daylight and views to nature is being severely curtailed in buildings. In parallel, increasingly urgent demands to sharply reduce building energy use and associated greenhouse gas emissions are being made to mitigate climate change. There are many challenges and performance tradeoffs associated with the building facade (i.e., daylight and view versus solar and glare control); increased prioritization of health and well-being as a fundamental human requirement could adversely affect building energy-efficiency. Given the current state of knowledge on the effects of daylight and view on health and well-being in buildings, we identify critical needs in research, tools and technologies that if satisfied may enable more effective use of daylight and view in buildings within the constraints of climate change. Lack of knowledge regarding the complex causal mechanisms of window views on human factors is a severely limiting factor in forward progress. Current models and methods to derive bidirectional scattering distribution functions (BSDFs) will need to be modified. Developers of energy-efficient window technologies will need more guidance to shape product development. Advanced window technologies and integrated design can enable attainment of both health and well-being and net zero energy goals, but considerable work will be needed to make such options turnkey and broadly available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are policy incentives for solar power effective? Evidence from residential installations in the Northeast

State incentives for solar power have grown significantly in the past several years. This paper examines the effectiveness of policy incentives to increase residential solar photovoltaic (PV) capacity. We use county-level panel data and control for demographic characteristics, solar resources, and pro-environmental preferences. Results show that among financial incentives, rebates have the most impact with an additional $1 per watt rebate increasing annual PV capacity additions by close to 50%. Factors that affect financial returns to solar PV such as electricity price and solar insolation are also found to be significant. Results also point to a significant positive relationship between hybrid vehicle sales and residential PV capacity growth, indicating the importance of pro-environmental preferences as a predictor of solar PV demand. Back of the envelope calculations suggest that the cost of carbon mitigation through rebates is around $184 per ton of CO2.

14 SOLAR ENERGY↗

Liquid Containing Clouds at the North Slope of Alaska Demonstrate Sensitivity to Local Industrial Aerosol Emissions

Abstract Cloud condensation nucleus control alter cloud solar albedo through cloud droplet size. Here, we leverage anthropogenic emissions at the North Slope of Alaska as a natural laboratory to study relationships between aerosols and Arctic liquid‐containing clouds. Averaging 14 years of MODIS observations, we found a reduction in temporally averaged cloud effective radius ( ) of up to 1.0 μm related to localized pollution. Pronounced regional gradients in cloud frequency of occurrence and liquid water path prohibit the detection of potential changes of these variables. Observed changes of alter radiative fluxes and increase cloud‐reflected shortwave radiation by up to 0.8 W m − 2 in the Prudhoe Bay area for the period covered by observations (April–September). Due to the frequent occurrence of liquid‐containing clouds, this implies that enhanced local emissions in Arctic regions can impact climate processes.

54 ENVIRONMENTAL SCIENCES↗

Geospace Plume and Its Impact on Dayside Magnetopause Reconnection Rate

The role a geospace plume in influencing the efficiency of magnetopause reconnection is an open question with two contrasting theories being debated. A local-control theory suggests that a plume decreases both local and global reconnection rates, whereas a global-control theory argues that the global reconnection rate is controlled by the solar wind rather than local physics. Observationally, limited numbers of point measurements from spacecraft cannot reveal whether a local change affects the global reconnection. A distributed observatory is hence needed to assess the validity of the two theories. We use THEMIS and Los Alamos National Laboratory spacecraft to identify the occurrence of a geospace plume and its contact with the magnetopause. Global evolution and morphology of the plume is traced using GPS measurements. SuperDARN is then used to monitor the distribution and the strength of dayside reconnection. Two storm-time geospace plume events are examined and show that as the plume contacts the magnetopause, the efficiency of reconnection decreases at the contact longitude. The amount of local decrease is 81% and 68% for the two events, and both values are consistent with the mass loading effect of the plume if the plume's atomic mass is ~4 amu. Reconnection in the surrounding is enhanced, and when the solar wind driving is stable, little variation is seen in the cross polar cap potential. This study illuminates a pathway to resolve the role of cold dense plasma on solar wind-magnetosphere coupling, and the observations suggest that plumes redistribute magnetopause reconnection activity without changing the global strength substantially.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ measurement of power conversion efficiency and molecular ordering during thermal annealing in P3HT:PCBM bulk heterojunction solar cells

Bulk heterojunction organic solar cells hold much promise as commercially viable sources of renewable energy due to their relatively inexpensive fabrication. Developing a fundamental knowledge of how processing conditions influence solar power conversion efficiency will enable rational and efficient design, optimization, and control of new organic solar cell materials. In this report, we use a combination of in situ current–voltage measurements and grazing-incidence wide-angle X-ray scattering experiments at elevated temperature to correlate the changes in photoconversion efficiency to the changes in the molecular ordering of a poly(3-hexylthiophene):[6,6]-phenyl-C₆₁-butyric acid methyl ester (P3HT:PCBM) bulk heterojunction active layer. In situ measurements of current–voltage characteristics were used to optimize the power conversion efficiency and the resulting thermal processing was in agreement with studies from repeated heating and cooling cycles. The improvements in short circuit current with thermal annealing were correlated to an increase in the population of face-on oriented crystallites of P3HT rather than improvements in molecular ordering of PCBM.

14 SOLAR ENERGY↗

The Role of Concentrating Solar Power Toward High Renewable Energy Penetrated Power Systems

Achieving high renewable energy penetrated power systems requires considerable operational flexibility to hedge the variability and uncertainty of variable renewable energy (VRE) generation. Compared with VRE sources, concentrating solar power (CSP) is an emerging controllable renewable generation technique that utilizes solar thermal power to generate electricity. The operational dispatchability of CSP would contribute to the power system transition toward high renewable penetration. In this paper, we explore how the generation portfolio will change toward high renewable energy penetrations, how much cost is involved, and what role CSP will play in realizing a high renewable energy penetrated power system. This study relies on a stochastic two-stage generation and transmission expansion planning model with CSP plants. The model captures the uncertainty and variability of renewable generation and the flexibility limits of thermal plants. With the target of achieving a renewable-dominated minimum-cost system with an expected renewable energy penetration level, the investments of both generation and transmission facilities are optimized. A case study on IEEE test systems with renewable technology cost data in 2050 is performed to analyze the value of CSP toward high renewable energy penetrated power systems.

14 SOLAR ENERGY↗

Market Brief: Customer-sited Distributed Energy Resources

This market brief summarizes key takeaways from interviews with vendors and service providers in one or more areas of the DER market: DER controls, battery storage, solar photovoltaic, thermal energy storage, combined heat and power, flexible building loads, and electric vehicle charging. Back-up generators used only in emergencies are not in the scope of this market brief.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Infrastructure Educational Initiative

The Clean Energy Infrastructure Educational Initiative represents a collaborative effort by the University of Dayton, Wright State University and Sinclair Community College. This effort above all aimed to establish energy related programs at each of the universities while also providing outreach to the local, state-wide, and national communities. At the University of Dayton, the grant has aimed at: solidfying a newly created Master's program in Renewable and Clean Energy; helping to establish and staff a regional sustainability organization for SW Ohio. As well, as the prime grantee, the University of Dayton was responsible for insuring curricular sharing between WSU and the University of Dayton. Finally, the grant, through its support of graduate students, and through cooperation with the largest utilities in SW Ohio enabled a region-wide evaluation of over 10,000 commercial building buildings in order to identify the priority buildings in the region for energy reduction. In each, the grant has achieved success. The main focus of Wright State was to continue the development of graduate education in renewable and clean energy. Wright State has done this in a number of ways. First and foremost this was done by continuing the development of the new Renewable and Clean Energy Master's Degree program at Wright State . Development tasks included: continuing development of courses for the Renewable and Clean Energy Master's Degree, increasing the student enrollment, and increasing renewable and clean energy research work. The grant has enabled development and/or improvement of 7 courses. Collectively, the University of Dayton and WSU offer perhaps the most comprehensive list of courses in the renewable and clean energy area in the country. Because of this development, enrollment at WSU has increased from 4 students to 23. Secondly, the grant has helped to support student research aimed in the renewable and clean energy program. The grant helped to solidify new research in the renewable and clean energy area. The educational outreach provided as a result of the grant included activities to introduce renewable and clean energy design projects into the Mechanical and Materials Engineering senior design class, the development of a geothermal energy demonstration unit, and the development of renewable energy learning modules for high school students. Finally, this grant supported curriculum development by Sinclair Community College for seven new courses and acquisition of necessary related instrumentation and laboratory equipment. These new courses, EGV 1201 Weatherization Training, EGV 1251 Introduction to Energy Management Principles, EGV 2301 Commercial and Industrial Assessment, EGV 2351 LEED Green Associate Exam Preparation, EGV 2251 Energy Control Strategies, EGV Solar Photovoltaic Design and Installation, and EGV Solar Thermal Systems, enable Sinclair to offer complete Energy Technology Certificate and an Energy Management Degree programs. To date, 151 students have completed or are currently registered in one of the seven courses developed through this grant. With the increasing interest in the Energy Management Degree program, Sinclair has begun the procedure to have the program approved by the Ohio Board of Regents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

5G Securely Energized and Resilient: (5G-SER) (Final Report)

NREL's work on 5G integration with physical power systems (versus simulated systems demonstrated in task 3) under 5G-Securely Energized and Resilient (5G-SER) achieved a major milestone in with the completion of Task 4 activities. After many months (6+) of planning and development along with scaling challenges along the way, a full 5G end-to-end network with physical hardware components (physical inverter, physical power panel, physical battery, etc.) was deployed in a containerized environment. In parallel, a distributed controls architecture for a microgrid powering 5G resources was also successfully modified from its previous instantiation for a simulated environment to work with these physical components. These accomplishments set the stage to use newly setup 5G technology with physical microgrid components to test the feasibility of 5G wireless with physical systems to enable resilient communications between controls and distributed solar and storage resources while exploring ways to configure 5G components to survive power disturbances. The results detailed in the report below show that even utilizing physical components, 5G wireless systems were able to provide resilient results that were similar to the results from the simulated environment Task 3).

24 POWER TRANSMISSION AND DISTRIBUTION↗

CalTestBed - Lucent Optics (CRADA Final Report)

The CRADA partner was developing a window film aimed at improving the control of the solar radiation that arrives at a building’s windows, ultimately reducing cooling loads and improving the distribution of daylight. The efforts under this CRADA were aimed at better understanding the performance of one or more prototypes of this film, with the aim of helping to narrow down the film design parameters to values more likely to achieve better performance. The technical means of achieving this project’s goals used LBNL’s world-class test facilities and expertise. These technical means included: (a) measurements of the bidirectional scattering distribution function (BSDF) of film samples, and (b) full-scale measurement of the energy (HVAC, lighting) and comfort (visual, thermal) impacts of at least one film prototype, for two solar angle “seasons” (“high” and “low” solar angle).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗