Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stack design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Cross-Layer Self-Adaptive/Self-Aware System Software for Exascale Systems

The extreme level of parallelism coupled with the limited available power budget expected in the exascale era brings unprecedented challenges that demand optimization of performance, power and resiliency in unison. Scalability on such systems is of paramount importance, while power and reliability issues may change the execution environment in which a parallel application runs. To solve these challenges exascale systems will require an introspective system software that combines system and application observations across all system stack layers with online feedback and adaptation mechanisms. In this paper we propose the design of a novel self-aware, self-adaptive system software in which a kernel-level Monitor, which continuously inspects the evolution of the target system through observation of Sensors, is combined with a user-level Controller, which reacts to changes in the execution environment, explores opportunities to increase performance, save power and adapts applications to new execution scenarios. We show that the monitoring system accurately monitors the evolution of parallel applications with a runtime overhead below 1-2%. As a test case, we design and implement a user-runtime system that aims at optimizing application’s performance and system power consumption on complex hierarchical architectures. Our results show that our adaptive system reaches 98% of performance efficiency of manually-tuned applications.

High Performance computing, Self-aware/self-adapti↗

kynema-driver [SWR-23-10]

Kynema-driver (FKA: exawind-driver) is a C++ code that is part of the kynema software stack. It is a driver for coupled Kynema-SGF/UGF simulations. It was designed to couple and drive hybrid-solver computational fluid dynamics (CFD) simulations where NLR'S kynema-sgf (SWR-20-85) software and NLR'S kynema-ugf (SWR-20-27) CFD codes are run simultaneously and are two-way coupled via overset meshes and the TIOGA overset-mesh library.

Rood, Jonathan↗

Solid oxide fuel cell power system development

This report summarizes the progress made during this contractual period in achieving the goal of developing the solid oxide fuel cell (SOFC) cell and stack technology to be suitable for use in highly-efficient, economically-competitive, commercially deployed electrical power systems. Progress was made in further understanding cell and stack degradation mechanisms in order to increase stack reliability toward achieving a 4+ year lifetime, in cost reduction developments to meet the SECA stack cost target of $175/kW (in 2007 dollars), and in operating the SOFC technology in a multi-stack system in a real-world environment to understand the requirements for reliably designing and operating a large, stationary power system.

30 DIRECT ENERGY CONVERSION↗

Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i.e., land use data that defines roughness, albedo, Bowen ratio, and other parameters) were processed using the AERSURFACE utility (Version 13016) (EPA 2013). Emission sources were modeled as point sources using actual stack locations and dimensions. Emissions, flow rates and exit temperatures were based on the design operating capacity of each source. All structures close enough to produce an area of wake effect were included for all sources. For multi-tiered structures, the heights of the tiers were included or the entire building height was assumed to be equal to the height of the tallest tier. Concentrations were calculated at 1,352 receptor locations provided by DEQ. All receptors were considered for each pollutant and averaging period. Maximum modeled CAP concentrations summed with average background concentration values were presented and compared to National Ambient Air Quality Standards (NAAQS). The background concentration values used were obtained using the Washington State University’s Laboratory for Atmospheric Research North West Airquest web-based retrieval tool (http://lar.wsu.edu/nw airquest/lookup.html). The air dispersion modeling results show the maximum impacts for CAPs are less than applicable standards and demonstrate the INL will not cause a violation of any ambient air quality standards.

54 ENVIRONMENTAL SCIENCES↗

Renewable Firming EnergyFarm Final Report

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided the U.S. Department of Energy (DOE) with funds to modernize the electric power grid. One program under this initiative is the Smart Grid Demonstration program (SGDP). The SGDP mandate is to demonstrate how a suite of existing and emerging smart grid technologies can be innovatively applied and integrated to prove technical, operational, and business-model feasibility. Primus Power is a provider of low cost, long life and long duration energy storage systems. The Company’s flow batteries are shipping to US and international microgrid, utility, military, commercial and industrial customers. Primus Power’s EnergyPod® is a modular battery system for grid scale applications available in configurations ranging from 25 kW to more than 25 MW. The EnergyPod provides nameplate power for 5 hours. This long duration unlocks economic benefits on both sides of the electric meter. It allows commercial and industrial customers to shift low cost electricity purchased at night to offset afternoon electrical peaks to reduce utility demand charges. It also allows utilities to economically reduce power peaks and defer costly upgrades to distribution infrastructure. An EnergyPod contains one or more EnergyCells-a highly engineered flow battery core made from low cost, readily available materials. An EnergyCell includes a membrane-free stack of titanium electrodes located above a novel liquid electrolyte management system. This patented design enables reliable, low maintenance operation for decades. It is safe and robust, featuring non-flammable aqueous electrolyte, sophisticated fault detection and built-in secondary containment. Unlike Li Ion batteries, the EnergyCell is not susceptible to thermal runaway. This cooperative agreement project was started in Feb 2010. The objectives of the project are: 1. Trigger rapid adoption of grid storage systems in the US by demonstrating a low cost, robust and flexible EnergyFarm®. 2. Accelerate adoption of renewable energy and enhance grid stability by firming the output of wind & solar farms. 3. Demonstrate improved grid asset utilization by storing energy during off-peak periods for dispatch during local load peaks. 4. Establish an advanced battery manufacturing industry in the U.S. 5. Reduce CO2 emissions from utilities. This report summarizes the key milestones, data, results and lessons learned from the project. The desired goals and benefits of the cooperative agreement with the DOE have all been achieved. The project has contributed to reducing power costs, accelerating adoption of renewable energy resources, reducing greenhouse gas emissions and establishing advanced battery manufacturing in the U.S. The Recovery Act funds provided thru the DOE have been leveraged multiple times by additional private equity investment. Primus Power continues to ship low cost, long life and long duration EnergyPod® flow battery systems to utilities, commercial/industrial, microgrid and data center customers. After the conclusion of this project, Primus Power has modified the EnergyPod® design to optimize around energy performance. Primus Power has moved to a prefabricated enclosure instead of multiple EnergyCells in a container. This lowers capital and maintenance costs and can optimize site design. Utilities are starting to adopt energy storage for a variety of functions. The market will grow as the technology is proven and profitable applications expand.

25 ENERGY STORAGE↗

Evaluation of Frameworks for HSCT Design Optimization

This report is an evaluation of engineering frameworks that could be used to augment, supplement, or replace the existing FIDO 3.5 (Framework for Interdisciplinary Design and Optimization Version 3.5) framework. The report begins with the motivation for this effort, followed by a description of an "ideal" multidisciplinary design and optimization (MDO) framework. The discussion then turns to how each candidate framework stacks up against this ideal. This report ends with recommendations as to the "best" frameworks that should be down-selected for detailed review.

Krishnan, Ramki↗

Small Portable PEM Fuel Cell Systems for NASA Exploration Missions

Oxygen-Hydrogen PEM-based fuel cell systems are being examined as a portable power source alternative in addition to advanced battery technology. Fuel cell power systems have been used by the Gemini, Apollo, and Space Shuttle programs. These systems have not been portable, but have been integral parts of their spacecraft, and have used reactants from a separate cryogenic supply. These systems typically have been higher in power. They also have had significant ancillary equipment sections that perform the pumping of reactants and coolant through the fuel cell stack and the separation of the product water from the unused reactant streams. The design of small portable fuel cell systems will be a significant departure from these previous designs. These smaller designs will have very limited ancillary equipment, relying on passive techniques for reactant and thermal management, and the reactant storage will be an integral part of the fuel cell system. An analysis of the mass and volume for small portable fuel cell systems was done to evaluate and quantify areas of technological improvement. A review of current fuel cell technology as well as reactant storage and management technology was completed to validate the analysis and to identify technology challenges

Burke, Kenneth A.↗

Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

Scheidegger, Brianne, T.↗

Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

This presentation describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover at the NASA Glenn Research Center. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the SCARAB rover s hotel loads. The power system, including the non-flow-through fuel cell technology, successfully demonstrated its goal as a range extender by powering hotel loads on the SCARAB rover, making this demonstration the first to use the non-flow-through fuel cell technology on a mobile platform.

Scheidegger, Brianne↗

Thermal Analysis of Cryogenic Hydrogen Liquid Separator

During launch for the new Space Launch System (SLS) liquid hydrogen is bleed through the engines during replenish, pre-press, and extended pre-press to condition the engines prior to launch. The predicted bleed flow rates are larger than for the shuttle program. A consequence of the increased flow rates is having liquif hydrogen in the vent system, which the facilities was never designed to handle. To remedy the problem a liquid separator is being designed in the system to accumulated the liquid propellant and protect the facility flare stack (which can only handle gas). The attached document is a presentation of the current thermalfluid analysis performed for the separator and will be presented at the Thermal and Fluid Analysis Workshop (NASA workshop) next week in Cleveland, Ohio.

liquid separator↗

Accelerated Testing Validation

The DOE Fuel Cell technical team recommended ASTs were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. The quantitative correlation of the degradation rates will have to take into account the various stressors in the field including temperature, relative humidity, start/stops and voltage cycles.

08 HYDROGEN↗

High-Performance SiC/SiC Ceramic Composite Systems Developed for 1315 C (2400 F) Engine Components

As structural materials for hot-section components in advanced aerospace and land-based gas turbine engines, silicon carbide (SiC) ceramic matrix composites reinforced by high performance SiC fibers offer a variety of performance advantages over current bill-of-materials, such as nickel-based superalloys. These advantages are based on the SiC/SiC composites displaying higher temperature capability for a given structural load, lower density (approximately 30- to 50-percent metal density), and lower thermal expansion. These properties should, in turn, result in many important engine benefits, such as reduced component cooling air requirements, simpler component design, reduced support structure weight, improved fuel efficiency, reduced emissions, higher blade frequencies, reduced blade clearances, and higher thrust. Under the NASA Ultra-Efficient Engine Technology (UEET) Project, much progress has been made at the NASA Glenn Research Center in identifying and optimizing two highperformance SiC/SiC composite systems. The table compares typical properties of oxide/oxide panels and SiC/SiC panels formed by the random stacking of balanced 0 degrees/90 degrees fabric pieces reinforced by the indicated fiber types. The Glenn SiC/SiC systems A and B (shaded area of the table) were reinforced by the Sylramic-iBN SiC fiber, which was produced at Glenn by thermal treatment of the commercial Sylramic SiC fiber (Dow Corning, Midland, MI; ref. 2). The treatment process (1) removes boron from the Sylramic fiber, thereby improving fiber creep, rupture, and oxidation resistance and (2) allows the boron to react with nitrogen to form a thin in situ grown BN coating on the fiber surface, thereby providing an oxidation-resistant buffer layer between contacting fibers in the fabric and the final composite. The fabric stacks for all SiC/SiC panels were provided to GE Power Systems Composites for chemical vapor infiltration of Glenn designed BN fiber coatings and conventional SiC matrices. Composite panels with system B were heat treated at Glenn, and the pores that remained open were filled by silicon melt infiltration (MI). Panels with system A and the other SiC/SiC systems were not heat treated, and remaining open pores in these systems were filled with SiC slurry and silicon MI.

DiCarlo, James A.↗

Development of a Mechanistic-Based Healing Model for Self-Healing Glass Seals

Self-healing glass, a recent development of hermetic sealant materials, has the ability to effectively repair damage when heated to elevated temperatures; thus, able to extend its service life. Since crack healing morphological changes in the glass material are usually temperature and stress dependent, quantitative studies to determine the effects of thermo-mechanical conditions on the healing behavior of the self-healing glass sealants are extremely useful to accommodate the design and optimization of the sealing systems within SOFCs. The goal of this task is to develop a mechanistic-based healing model to quantify the stress and temperature dependent healing behavior. A two-step healing mechanism was developed and implemented into finite element (FE) models through user-subroutines. Integrated experimental/kinetic Monte Carlo (kMC) simulation methodology was taken to calibrate the model parameters. The crack healing model is able to investigate the effects of various thermo-mechanical factors; therefore, able to determine the critical conditions under which the healing mechanism will be activated. Furthermore, the predicted results can be used to formulate the continuum damage-healing model and to assist the SOFC stack level simulations in predicting and evaluating the effectiveness and the performance of various engineering seal designs.

Fuel Cell↗

Assessment of MiniFuel Subcapsule Design Recommendations on Previous Experiments

MiniFuel describes the class of separate effects nuclear fuels irradiation experiments that have been conducted in the High Flux Isotope Reactor (HFIR) since 2018. These experiments comprise a stack of six fuel-bearing subcapsules contained in a stainless steel target housing that is in contact with HFIR coolant on its exterior. All MiniFuel targets have a near-standardized architecture, and the primary design variables that change between experiments are the radial gap size between the subcapsule and housing and the target fill gas composition. Finite element heat transfer models are used to determine the optimum gas composition and gap sizes, and recent studies were performed to identify model parameters that contribute the most uncertainty to fuel specimen temperature predictions. That work, which is referenced herein, also recommended a set of design modifications to the subcapsule internal architecture and assembly process. These modifications are intended to reduce fuel temperature uncertainty in future experiments. In this report, the subcapsule design modifications were retroactively applied to a previously conducted MiniFuel experiment to determine how these changes affect the established safety and performance envelope of the experimental capability. These effects were determined in two steps. First, the modifications were applied to the subcapsule design without any other changes to determine their isolated effect on the predicted fuel specimen temperatures. This portion of the analysis showed that fuel temperatures were modestly reduced because the implemented changes improved heat transfer efficacy. Next, traditional MiniFuel design activities (i.e., sizing the gas gaps and determining the fill gas composition) were reperformed, and they confirmed that the original desired fuel temperatures could be achieved while remaining within established safety limits. Therefore, this report demonstrates improved performance resulting from the subcapsule modifications, which mitigate uncertainty while meeting the objectives of past experiments. An additional benefit of the design changes is reduced sensitivity of the fuel temperature to the evolving flux spectrum in HFIR, leading to more stable temperatures and enhanced utility of MiniFuel as a separate effects irradiation platform.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cummins R-SOFC System Development

The overall purpose of this project was to reduce the Reversible-Solid Oxide Fuel Cell (R-SOFC) system cost by developing two technologies, an improved cell design and the incorporation of an ejector in the fuel recycle loop instead of a blower. A Simulink model of the baseline SOFC system was developed and calibrated with experimental test data. The R-SOFC system model was built by integrating GT Suite developed models of the steam generation components into the baseline Simulink SOFC system model. The ability to run the stack in SOEC operating mode was also added to the model. The system model was used to explore the ability of the R-SOFC system to meet operational constraints on Steam/Carbon ratio and H2 concentration on the fuel side electrode. A CFD ejector model was developed and used to explore a range of ejector design parameters, leading to the final ejector design that was prototyped for testing. A prototype steam ejector was first tested in a laboratory environment using room temperature air. The steam ejector was subsequently tested using the full hot recycle loop with all relevant heat exchangers and steam generation components. The test conditions utilized temperatures, pressures, and flow rates expected in an R-SOFC application. Throughout the experimental testing work, ejector performance test data was used to improve and then validate the CFD ejector model. A CFD cell model was developed and used to optimize thermal gradients, voltage, and cost of a new cell substrate design. A CFD comparison of co-flow and cross-flow cell designs informed the decision to use a co-flow design for the new cell substrate. Multiple rounds of CFD simulation were used to improve the cell design to minimize the variation in air and fuel distribution across cell channels and to minimize the variation in air and fuel distribution across different cells in the stack. A few prototypes of the new cell substrate design were produced and validated in a laboratory environment by thermally spraying and verifying that they met established manufacturing specifications. The cell manufacturing process was adjusted in order to bring these metrics within acceptable tolerances. Cummins’ internal calculations show that the new cell design reduces cost ~50% compared to the baseline cell, while the ejector + superheater/boiler concept reduces cost of the recycle loop by ~40%. The impact of these cost reductions on the cost of producing H2 will depend on the specific system where they are applied. Therefore, a Techno-Economic Analysis was completed using system cost as a variable, and showing how the NREL Current and Future system costs translate into H2 production cost.

Henrichsen, Lars↗

Automated Fiber Placement Through Thickness Defect Stacking Optimization

In its 2022 commercial market outlook, Boeing forecasted an 80% increase in the global fleet through 2041 compared to 2019 pre-pandemic levels. This sharp rise in demand will drive pressure onto airframe manufacturers to ramp up production and find more efficient ways to design and manufacture airplanes. Complicating this challenge is the industry’s recent transformation from traditional metal-based airframes towards hybrid composite-metal aircraft. While composites have been used in aviation for decades, aircraft manufacturers are still struggling to design and manufacture quality parts at a high rate. Automated Fiber Placement (AFP) is one of the main manufacturing techniques used to produce large-scale composite parts. After a design has been created, a manufacturing strategy has to be developed based on the working material, part geometry, and machine capabilities. This process planning stage is essential to the AFP workflow and currently requires a high level of manual input from an experienced process planner. In an effort to automate and optimize this stage, the Computer Aided Process Planning (CAPP) module was developed. CAPP assists process planners in identifying optimal starting point location and layup strategy for each ply of a laminate. This Ply-Level Optimization (PLO) phase operates on the quantification of ply quality through predictable geometry-based defects such as gaps, overlaps, angle deviation, and steering. As you move from PLO to Laminate-Level Optimization (LLO) the design space grows exponentially, emphasizing the need for automated optimization. The work presented in this thesis expands CAPP’s functionality by comparing the planned fiber paths through the thickness of the laminate to mitigate stacked area defects and achieve an optimal laminate-level manufacturing strategy. Within CAPP, predicted gap and overlap defects are imported from Vericut Composites Programming (VCP) and then discretized to streamline the through-thickness comparison. Two objective functions are used to score different combinations of ply layup strategies based on defect stacking both globally and locally. Four combinatorial optimization algorithms were coupled with these objective functions to investigate the laminate-level manufacturing strategy design space and converge on the optimal plan. These algorithms were evaluated based on accuracy and efficiency through virtual testing on a complex tool surface. A separate LLO approach was developed to achieve near-optimal laminates in significantly less time. The end result is a software package which greatly reduces the required input from process planners, shortening the design-build cycle time and improving part quality.

AFP↗

Decoupling between Shockley partials and stacking faults strengthens multiprincipal element alloys

We report that mechanical properties are fundamental to structural materials, where dislocations play a decisive role in describing their mechanical behavior. Although the high-yield stresses of multiprincipal element alloys (MPEAs) have received extensive attention in the last decade, the relation between their mechanistic origins remains elusive. Our multiscale study of density functional theory, atomistic simulations, and high-resolution microscopy shows that the excellent mechanical properties of MPEAs have diverse origins. The strengthening effects through Shockley partials and stacking faults can be decoupled in MPEAs, breaking the conventional wisdom that low stacking fault energies are coupled with wide partial dislocations. This study clarifies the mechanistic origins for the strengthening effects, laying the foundation for physics-informed predictive models for materials design.

36 MATERIALS SCIENCE↗

Redox flow cell energy storage systems

NASA-Redox systems are electrochemical storage devices that use two fully soluble Redox couples, anode and cathode fluids, as active electrode materials separated by a highly selective ion exchange membrane. The reactants are contained in large storage tanks and pumped through a stack of Redox flow cells where the electrochemical reactions (reduction and oxidation) take place at porous carbon felt electrodes. A string or stack of these power producing cells is connected in series in a bipolar manner. Redox energy storage systems promise to be inexpensive and possess many features that provide for flexible design, long life, high reliability and minimal operation and maintenance costs. These features include independent sizing of power and storage capacity requirements and inclusion within the cell stack of a cell that monitors the state of charge of the system as a whole, and a rebalance cell which permits continuous correction to be made for minor side reactions that would tend to result in the anode fluid and cathode fluids becoming electrochemically out of balance. These system features are described and discussed.

Thaller, L. H.↗