Search NASA⌕ Search

SEARCH · Search NASA

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The role of plasma evolution and photon transport in optimizing future advanced lithography sources

Laser produced plasma (LPP) sources for extreme ultraviolet (EUV) photons are currently based on using small liquid tin droplets as target that has many advantages including generation of stable continuous targets at high repetition rate, larger photons collection angle, and reduced contamination and damage to the optical mirror collection system from plasma debris and energetic particles. The ideal target is to generate a source of maximum EUV radiation output and collection in the 13.5 nm range with minimum atomic debris. Based on recent experimental results and our modeling predictions, the smallest efficient droplets are of diameters in the range of 20–30 μm in LPP devices with dual-beam technique. Such devices can produce EUV sources with conversion efficiency around 3% and with collected EUV power of 190 W or more that can satisfy current requirements for high volume manufacturing. One of the most important characteristics of these devices is in the low amount of atomic debris produced due to the small initial mass of droplets and the significant vaporization rate during the pre-pulse stage. In this study, we analyzed in detail plasma evolution processes in LPP systems using small spherical tin targets to predict the optimum droplet size yielding maximum EUV output. We identified several important processes during laser-plasma interaction that can affect conditions for optimum EUV photons generation and collection. The importance and accurate description of modeling these physical processes increase with the decrease in target size and its simulation domain.

36 MATERIALS SCIENCE↗

Slow dynamics of a protein backbone in molecular dynamics simulation revealed by time-structure based independent component analysis

We recently proposed the method of time-structure based independent component analysis (tICA) to examine the slow dynamics involved in conformational fluctuations of a protein as estimated by molecular dynamics (MD) simulation [Y. Naritomi and S. Fuchigami, J. Chem. Phys. 134, 065101 (2011)]. Our previous study focused on domain motions of the protein and examined its dynamics by using rigid-body domain analysis and tICA. However, the protein changes its conformation not only through domain motions but also by various types of motions involving its backbone and side chains. Some of these motions might occur on a slow time scale: we hypothesize that if so, we could effectively detect and characterize them using tICA. In the present study, we investigated slow dynamics of the protein backbone using MD simulation and tICA. The selected target protein was lysine-, arginine-, ornithine-binding protein (LAO), which comprises two domains and undergoes large domain motions. MD simulation of LAO in explicit water was performed for 1 μs, and the obtained trajectory of C{sub α} atoms in the backbone was analyzed by tICA. This analysis successfully provided us with slow modes for LAO that represented either domain motions or local movements of the backbone. Further analysis elucidated the atomic details of the suggested local motions and confirmed that these motions truly occurred on the expected slow time scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Indirect-drive ablative Rayleigh-Taylor growth experiments on the Shenguang-II laser facility

In this research, a series of single-mode, indirect-drive, ablative Rayleigh-Taylor (RT) instability experiments performed on the Shenguang-II laser facility [X. T. He and W. Y. Zhang, Eur. Phys. J. D 44, 227 (2007)] using planar target is reported. The simulation results from the one-dimensional hydrocode for the planar foil trajectory experiment indicate that the energy flux at the hohlraum wall is obviously less than that at the laser entrance hole. Furthermore, the non-Planckian spectra of x-ray source can strikingly affect the dynamics of the foil flight and the perturbation growth. Clear images recorded by an x-ray framing camera for the RT growth initiated by small- and large-amplitude perturbations are obtained. The observed onset of harmonic generation and transition from linear to nonlinear growth regime is well predicted by two-dimensional hydrocode simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the {sup 13}C(α,n){sup 16}O reaction with the Trojan horse method: Focus on the sub threshold resonance at −3 keV

The {sup 13}C(α,n){sup 16}O reaction is the neutron source of the main component of the s-process. The astrophysical S(E)-factor is dominated by the −3 keV sub-threshold resonance due to the 6.356 MeV level in {sup 17}O. Its contribution is still controversial as extrapolations, e.g., through R-matrix calculations, and indirect techniques, such as the asymptotic normalization coefficient (ANC), yield inconsistent results. Therefore, we have applied the Trojan Horse Method (THM) to the {sup 13}C({sup 6}Li,n{sup 16}O)d reaction to measure its contribution. For the first time, the ANC for the 6.356 MeV level has been deduced through the THM, allowing to attain an unprecedented accuracy. Though a larger ANC for the 6.356 MeV level is measured, our experimental S(E) factor agrees with the most recent extrapolation in the literature in the 140-230 keV energy interval, the accuracy being greatly enhanced thanks to this innovative approach, merging together two well establish indirect techniques, namely, the THM and the ANC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shock wave acceleration of protons in inhomogeneous plasma interacting with ultrashort intense laser pulses

The acceleration of protons, triggered by solitary waves in expanded solid targets is investigated using particle-in-cell simulations. The near-critical density plasma is irradiated by ultrashort high power laser pulses, which generate the solitary wave. The transformation of this soliton into a shock wave during propagation in plasma with exponentially decreasing density profile is described analytically, which allows to obtain a scaling law for the proton energy. The high quality proton bunch with small energy spread is produced by reflection from the shock-front. According to the 2D simulations, the mechanism is stable only if the laser pulse duration is shorter than the characteristic development time of the parasitic Weibel instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atomic-scale thermocapillary flow in focused ion beam milling

Focused ion beams provide a means of nanometer-scale manufacturing and material processing, which is used for applications such as forming nanometer-scale pores in thin films for DNA sequencing. We investigate such a configuration with Ga{sup +} bombardment of a Si thin-film target using molecular dynamics simulation. For a range of ion intensities in a realistic configuration, a recirculating melt region develops, which is seen to flow with a symmetrical pattern, counter to how it would flow were it driven by the ion momentum flux. Such flow is potentially important for the shape and composition of the formed structures. Relevant stress scales and estimated physical properties of silicon under these extreme conditions support the importance thermocapillary effects. A flow model with Marangoni forcing, based upon the temperature gradient and geometry from the atomistic simulation, indeed reproduces the flow and thus could be used to anticipate such flows and their influence in applications.

36 MATERIALS SCIENCE↗

A METHOD TO EXTRACT THE ANGULAR POWER SPECTRUM OF THE EPOCH OF REIONIZATION FROM LOW-FREQUENCY RADIO INTERFEROMETERS

The redshifted 21 cm signal of neutral hydrogen from the epoch of reionization (EoR) is extremely weak and its first detection is therefore expected to be statistical with first-generation low-frequency radio interferometers. In this Letter, we propose a method to extract the angular power spectrum of the EoR from the visibility correlation coefficients p{sub ij} (u, v), instead of the visibilities V{sub ij} (u, v) measured directly by radio interferometers in conventional algorithm. The visibility correlation coefficients are defined as p{sub ij}(u,v)=V{sub ij}(u,v)/{radical}(|V{sub ii}||V{sub jj}|) by introducing the autocorrelation terms V{sub ii} and V{sub jj} such that the angular power spectrum C{sub l} can be obtained through C{sub l} = T {sup 2}{sub 0}(|p{sub ij} (u, v)|{sup 2}), independently of the primary beams of antennas. This also partially removes the influence of receiver gains in the measurement of C{sub l} because the amplitudes of the gains cancel each other out in the statistical average operation of (|p{sub ij} (u, v)|{sup 2}). We use the average system temperature T{sub 0} as a calibrator of C{sub l}, which is dominated by the Milky Way and extragalactic sources in the frequency range that we are interested in, below 200 MHz. Finally, we demonstrate the feasibility of this novel method using the simulated sky maps as targets and the 21 CentiMeter Array (21CMA) as interferometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Primordial non-Gaussianity from the completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey II: measurements in Fourier space with optimal weights

ABSTRACT We present measurements of the local primordial non-Gaussianity parameter $f_{\mathrm{NL}}^\mathrm{local} $from the clustering of 343 708 quasars with redshifts 0.8 < z < 2.2 distributed over 4808 deg2 from the final data release (DR16) of the extended Baryon Acoustic Oscillation Spectroscopic Survey (eBOSS), the largest volume spectroscopic survey up to date. Our analysis is performed in Fourier space, using the power spectrum monopole at very large scales to constrain the scale-dependent halo bias. We demonstrate the robustness of our analysis pipeline with EZ-mock catalogues that simulate the eBOSS DR16 target selection. We carefully assess the impact of systematics on our measurement, exploiting a novel neural network scheme for cleaning the DR16 sample as well as test multiple contamination removal methods. We estimate the bias due to the overcorrection of the systematic removal to be sub-dominant compared to the statistical uncertainty. We find fNL = −12 ± 21 (68 per cent confidence) for the main clustering sample including quasars with redshifts between 0.8 and 2.2, after applying redshift weighting techniques, designed for non-Gaussianity measurement from large scales structure, to optimize our analysis, which improve our results by 37 per cent.

79 ASTRONOMY AND ASTROPHYSICS↗

Trabecula: A Random Generator of Computational Phantoms for Bone Marrow Dosimetry

This study was motivated by the efforts on evaluation of radiation risk for leukemia incidence in the Techa River Cohort, where the main bone marrow dose contributors were 89,90Sr (bone-seeking beta emitters). Energy deposition in bone marrow targets was evaluated by simulating radiation particle transport using computational phantoms. The present paper describes the computer program “Trabecula” implementing an algorithm for parametric generation of computational phantoms, which serve as the basis for calculating bone marrow doses. “Trabecula” is a user-friendly tool that automatically converts analytical models into voxelized representations that are directly compatible as input to MCNP.

Shishkina, Elena A.↗

Preparing sparse solvers for exascale computing

Sparse solvers provide essential functionality for a wide variety of scientific applications. Highly parallel sparse solvers are essential for continuing advances in high-fidelity, multi-physics and multi-scale simulations, especially as we target exascale platforms. This paper describes the challenges, strategies and progress of the US Department of Energy Exascale Computing project towards providing sparse solvers for exascale computing platforms. We address the demands of systems with thousands of high-performance node devices where exposing concurrency, hiding latency and creating alternative algorithms become essential. The efforts described here are works in progress, highlighting current success and upcoming challenges.

97 MATHEMATICS AND COMPUTING↗

Population of low-seniority isomeric states of {sup 206}Hg by two-proton knockout reactions at relativistic energies

We consider calculations of direct two-proton removal reactions from a relativistic-energy {sup 208}Pb beam incident on a {sup 9}Be target, leading to the population of two-proton-hole isomeric configurations in {sup 206}Hg. The calculated 5{sup -} and 10{sup +} isomeric state population ratios of 18.8% and 4.7%, respectively, are in fair agreement with the values deduced experimentally (21.9{sub -2.9}{sup +1.2}% and 3.1{sub -1.2}{sup +1.0}%); however, the high density of final states in this case complicates the prediction of isomeric ratios for those states fed by unobserved prompt {gamma}-ray cascades. We also consider and quantify the effects of selection of events, according to the longitudinal momenta of the reaction residues, on the measured isomeric ratios for high-spin final states and, hence, of the potential to exploit such sensitivity to gain further insight into the reaction mechanism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decoupling behavior in {sup 132}La

Heavy-ion fusion reactions {sup 122}Sn({sup 14,15}N, xn){sup 132}La have been utilized for the lifetime measurements using the recoil distance method. The lifetimes of seven low-lying excited states were obtained. In addition, the lifetimes of two states belonging to a band, which was identified as a decoupled band, were obtained. The decoupling behavior in {sup 132}La has been theoretically investigated using the particle-rotor model in the model space of {pi}h{sub 11/2} and ({nu}s{sub 1/2}, {nu}d{sub 3/2}). The pseudospin coupling model was also utilized to understand the decoupling behavior in terms of the valence-particle configuration {pi}h{sub 11/2}({Omega}{sub {pi}}=(1/2)) x {nu}[411-tilde]({Omega}{sub {nu}}=(1/2),(3/2)), and a reasonable agreement with the experiment was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission fragment angular distributions in the {sup 9}Be + {sup 232}Th reaction

Fission fragment angular distributions have been measured for a {sup 9}Be + {sup 232}Th system at four different beam energies around the Coulomb barrier. The experimental results on fission fragment anisotropies have been compared with predictions of the standard statistical saddle-point model (SSPM) and the preequilibrium fission (PEQ) model including projectile ground-state spin. It is observed that both SSPM and the PEQ model fail to reproduce the experimental results, indicating that projectile breakup may affect the fission fragment anisotropies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elemental characterization of LL-MA radioactive waste packages with the associated particle technique

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R and D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages with analytical methods and with non-destructive nuclear measurements. This paper concerns fast neutron interrogation with the associated particle technique (APT), which brings 3D information about the waste material composition. The characterization of volume elements filled with iron, water, aluminium, and PVC in bituminized and fibre concrete LL-MA waste packages has been investigated with MCNP [1] and MODAR data analysis software [2]. APT provides usable information about major elements presents in the volumes of interest. However, neutron scattering on hydrogen nuclei spreads the tagged neutron beam out of the targeted volume towards surrounding materials, reducing spatial selectivity. Simulation shows that small less than 1 L targets can be characterised up to the half-radius of a 225 L bituminized drum, the matrix of which is very rich in hydrogen. Deeper characterization in concrete is possible but limited by counting statistics due to photon attenuation in this dense matrix and, unless large inspection volumes are considered, by the lack of spatial selectivity of the tagged neutron beam due to neutron scattering. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of Shock Formation Parameters With Drive Conditions in Magnetically Accelerated Plasma Flows

We present experimental data regarding the formation of high-energy-density shocks in magnetically accelerated plasma flows using pulsed power drivers. We quantify the flow velocity and temperature of the ablated plasma using optical Thomson scattering and gated emission imaging across two different generators. We show that, regardless of the drive parameters, the plasma flows show continuous acceleration over centimeter spatial scales, in line with trends in published simulation work. When stationary targets are placed in these supersonic flows, bow-shock formation is observed at all drive parameters in a range of materials. In the higher density flow generated on the 1-MA COBRA generator at Cornell University, heating of the upstream flow ahead of the shock is observed and quantified, which is not observed at the lower density flow on the 0.2-MA Bertha driver at UC San Diego. Here, when combined with previous work on the XP generator at Cornell, we can show that these three experimental setups allow control of the effect of radiation loss and upstream absorption on the formation of the bow shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗