'Thermodynamics' of minimal surfaces and entropic origin of gravity

Deformations of minimal surfaces lying in constant-time slices in static space-times are studied. An exact and universal formula for a change of the area of a minimal surface under shifts of nearby pointlike particles is found. It allows one to introduce a local temperature on the surface and represent variations of its area in a thermodynamical form by assuming that the entropy in the Planck units equals the quarter of the area. These results provide a strong support to a recent hypothesis that gravity has an entropic origin, the minimal surfaces being a sort of holographic screens. The gravitational entropy also acquires a definite physical meaning related to quantum entanglement of fundamental degrees of freedom across the screen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact-Ionization Cooling in Laser-Induced Plasma Filaments

The ionization rates and subsequent electron dynamics for laser-induced plasma channels are measured for the noble gas series He, Ne, Ar, Kr, and Xe at 1.0 atm. The cw fluorescence emission increases superlinearly in the series from He to Xe in agreement with Ammosov-Delone-Krainov tunnel ionization calculations. The electron temperature after laser-induced plasma formation, measured by four-wave mixing, evolves from >20 eV to <1 eV kinetic energies with time constants ranging from 1 ns for He to 100 ps for Xe in agreement with an impact-ionization cooling model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constant-Depth Preparation of Matrix Product States with Adaptive Quantum Circuits

Adaptive quantum circuits, which combine local unitary gates, midcircuit measurements, and feedforward operations, have recently emerged as a promising avenue for efficient state preparation, particularly on near-term quantum devices limited to shallow-depth circuits. Matrix product states (MPS) comprise a significant class of many-body entangled states, efficiently describing the ground states of one-dimensional gapped local Hamiltonians and finding applications in a number of recent quantum algorithms. Recently, it has been shown that the Affleck-Kennedy-Lieb-Tasaki state—a paradigmatic example of an MPS—can be exactly prepared with an adaptive quantum circuit of constant depth, an impossible feat with local unitary gates alone due to its nonzero correlation length [Smith , PRX Quantum 4, 020315 (2023)]. In this work, we broaden the scope of this approach and demonstrate that a diverse class of MPS can be exactly prepared using constant-depth adaptive quantum circuits, outperforming theoretically optimal preparation with unitary circuits. We show that this class includes short- and long-ranged entangled MPS, symmetry-protected topological (SPT) and symmetry-broken states, MPS with finite Abelian, non-Abelian, and continuous symmetries, resource states for MBQC, and families of states with tunable correlation length. Moreover, we illustrate the utility of our framework for designing constant-depth sampling protocols, such as for random MPS or for generating MPS in a particular SPT phase. We present sufficient conditions for particular MPS to be preparable in constant time, with global on-site symmetry playing a pivotal role. Altogether, this work demonstrates the immense promise of adaptive quantum circuits for efficiently preparing many-body entangled states and provides explicit algorithms that outperform known protocols to prepare an essential class of states. Published by the American Physical Society 2024

Smith, Kevin C. (ORCID:0000000223971518)↗

Greybox Thermal Parameter Identification of Electric Machine Stators

The parameters of electric machine thermal equivalent circuit networks are difficult to predict due to material and manufacturing uncertainties. In this paper, a Greybox system identification approach is used to identify parameters of electric machine stator lumped parameter thermal networks (LPTNs). LPTNs provide a low order, computationally efficient, dynamic model of temperatures at specific locations. Second and third order LPTN model structures are defined as state space equations with stator thermal parameters to be identified. To test the Greybox electric machine stator thermal system identification, five stator motorette prototypes were constructed with controlled variations in slot fill and slot liner thickness. The variation in the motorette thermal parameters and thermal time constants are detected using the Greybox identification. Special attention is given to the impact of sampling rate and Greybox data record length on parameter estimation accuracy.

33 ADVANCED PROPULSION SYSTEMS↗

Charging characteritiscs of ultrananocrystalline diamond in RF MEMS capacitive switches.

Modifications to a standard capacitive MEMS switch process have been made to allow the incorporation of ultra-nano-crystalline diamond as the switch dielectric. The impact on electromechanical performance is minimal. However, these devices exhibit uniquely different charging characteristics, with charging and discharging time constants 5-6 orders of magnitude quicker than conventional materials. This operation opens the possibility of devices which have no adverse effects of dielectric charging and can be operated near-continuously in the actuated state without significant degradation in reliability.

36 MATERIALS SCIENCE↗

Capacitance Transients, Photoconductive Decay, and Impedance Spectroscopy on 19% to 22% Efficient Silicon Solar Cells

High efficiency silicon solar cells are characterized using current-voltage curves, electroluminescence imaging, impedance spectroscopy, capacitance transients, microwave photoconductive decay, and time-resolved photoluminescence imaging. The sample set is composed of cells from different manufacturers and includes an n-type silicon heterojunction (SHJ), an n-type passivated emitter rear totally diffused (PERT), and five different p-type passivated emitter rear contact (PERC) cells. Carrier lifetimes, both photoconductivity and photoluminescence, are measured co-located with the light excitation pulse and within the cell but away from the light spot. Luminescence intensity and excess carrier lifetimes correlate to cell voltage. The capacitance transient time constants correlate to the capacitance values extracted from impedance spectroscopy.

capacitance↗

Robust Decentralized Secondary Frequency Control in Power Systems: Merits and Trade-Offs

Frequency restoration in power systems is conven- tionally performed by broadcasting a centralized signal to local controllers. As a result of the energy transition, technological advances, and the scientific interest in distributed control and optimization methods, a plethora of distributed frequency control strategies have been proposed recently that rely on communication amongst local controllers. In this paper we propose a fully decentralized leaky integral controller for frequency restoration that is derived from a classic lag element. We study steady-state, asymptotic optimality, nominal stability, input-to-state stability, noise rejection, transient performance, and robustness properties of this controller in closed loop with a nonlinear and multivariable power system model. Here, we demonstrate that the leaky integral controller can strike an acceptable trade-off between performance and robustness as well as between asymptotic disturbance rejection and transient convergence rate by tuning its DC gain and time constant. We compare our findings to conventional decentralized integral control and distributed- averaging-based integral control in theory and simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Interfilament Coupling Currents and Their Effect on Magnet Quench Protection

Variations in the transport current of a superconducting magnet cause several types of transitory losses. Due to its relatively short time constant, usually of the order of a few tens of milliseconds, interfilament coupling loss can have a significant effect on the coil protection against overheating after a quench. This loss is deposited in the strands and can facilitate a more homogeneous transition to the normal state of the coil turns. Furthermore, the presence of local interfilament coupling currents reduces the magnet's differential inductance, which in turn provokes a faster discharge of the transport current. The lumped-element dynamic electrothermal model of a superconducting magnet has been developed to reproduce these effects. Simulations are compared to experimental electrical transients and found in good agreement. After its validation, the model can be used for predicting the performance of quench protection systems based on energy extraction, quench heaters, the newly developed coupling-loss-induced quench protection system, or combinations of those. The impact of interfilament coupling loss on each protection system is discussed.

43 PARTICLE ACCELERATORS↗

Use of Transition Models to Design High Performance TESs for the LCLS-II Soft X-Ray Spectrometer

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 μs. In the past, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we observe how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

47 OTHER INSTRUMENTATION↗

The Effect of Gamma Radiation Exposure on Active Silicon Photonic Device Performance Metrics

In this study, we test Si vertical junction disk modulators and waveguide-integrated Ge PIN photodiodes to see how the key performance metrics are affected by 60Co gamma radiation (total ionizing dose), a common proxy for simulating a mix of high energy ion particle flux. It is found that reverse bias dark current increases significantly for both devices after 1 Mrad(Si) exposure. Whereas the bandwidth of the Si disk modulator decreases by 6.5 % after 1 Mrad(Si) dose, the bandwidth of the Ge PIN photodiode appears to be unaffected. The increased sensitivity of the Si disk modulator bandwidth to gamma radiation is hypothesized to be caused by a decrease in the carrier concentration of the junction with a resulting increase in p-n junction RC time constant. The Ge PIN photodiode is relatively insensitive to the surface effects because the absorption happens away from the SiO2-Ge interface and the gamma radiation has a minimal effect on carrier mobility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient Photocurrent From High-Voltage Vertical GaN Diodes Irradiated With Electrons: Experiments and Simulations

Radiation-hard high-voltage vertical GaN p-n diodes are being developed for use in power electronics subjected to ionizing radiation. Here, we present a comparison of the measured and simulated photocurrent response of diodes exposed to ionizing irradiation with 70 keV and 20 MeV electrons at dose rates in the range of 1.4x10 7 - 5.0x10 8 rad(GaN)/s. The simulations correctly predict the trend in measured steady-state photocurrent and agree with experimental results within a factor of 2. Furthermore, simulations of the transient photocurrent response to dose rates with uniform and non-uniform ionization depth profiles uncover the physical processes involved that cannot be otherwise experimentally observed due to orders of magnitude larger RC time constant of the test circuit. The simulations were performed using an Exploratory Physics Development code developed at Sandia National Laboratories. The code offers the capability to include defect physics under more general conditions, not included in commercially available software packages, extending the applicability of the simulations to different types of radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Efficient Wait-Free Vector

The vector is a fundamental data structure, which provides constant-time access to a dynamically-resizable range of elements. Currently, there exist no wait-free vectors. The only non-blocking version supports only a subset of the sequential vector API and exhibits significant synchronization overhead caused by supporting opposing operations. Since many applications operate in phases of execution, wherein each phase only a subset of operations are used, this overhead is unnecessary for the majority of the application. To address the limitations of the non-blocking version, we present a new design that is wait-free, supports more of the operations provided by the sequential vector, and provides alternative implementations of key operations. These alternatives allow the developer to balance the performance and functionality of the vector as requirements change throughout execution. Compared to the known non-blocking version and the concurrent vector found in Intel’s TBB library, our design outperforms or provides comparable performance in the majority of tested scenarios. Over all tested scenarios, the presented design performs an average of 4.97 times more operations per second than the non-blocking vector and 1.54 more than the TBB vector. In a scenario designed to simulate the filling of a vector, performance improvement increases to 13.38 and 1.16 times. This work presents the first ABA-free non-blocking vector. Finally, unlike the other non-blocking approach, all operations are wait-free and bounds-checked and elements are stored contiguously in memory.

97 MATHEMATICS AND COMPUTING↗

Output Capacitance Loss of GaN HEMTs in Steady-State Switching

The output capacitance (C OSS ) loss, a loss produced when the device’s output capacitor is charged and discharged, has become a concern for GaN high electron mobility transistors (HEMTs) in high-frequency applications. This work presents a new, easy-to-implement method for the C OSS loss characterization based on the unclamped inductive switching (UIS) setup. As compared to prior approaches, this method involves the device’s ON-state conduction and could measure the C OSS loss in a single pulse and the steady-state switching. The C OSS loss of three types of mainstream commercial GaN HEMTs is characterized, which exhibit some common dependencies including a non-monotonic relation with the dv/dt (or resonance frequency), a linear relation with the ON-state current, a power-law relation with the peak blocking voltage, and little temperature dependence. In addition, their C OSS losses all show minimal distinctions in a single pulse and the steady-state switching, despite the increased on-resistance in the steady-state switching. Furthermore, this suggests that the traps accounting for the C OSS loss possess different de-trapping time constants as compared to the traps governing the dynamic on-resistance. Finally, a unified model is established to describe the C OSS loss of all three types of GaN HEMTs. These results provide important references for the high-frequency application of GaN HEMTs and new insights into the physical origin of their C OSS loss.1

42 ENGINEERING↗

Predictive assessment of kidney functional recovery following ischemic injury using optical spectroscopy

Functional changes in rat kidneys during the induced ischemic injury and recovery phases were explored using multimodal autofluorescence and light scattering imaging. We aim to evaluate the use of noncontact optical signatures for rapid assessment of tissue function and viability. Specifically, autofluorescence images were acquired in vivo under 355, 325, and 266 nm illumination while light scattering images were collected at the excitation wavelengths as well as using relatively narrowband light centered at 500 nm. The images were simultaneously recorded using a multimodal optical imaging system. We also analyzed to obtain time constants, which were correlated to kidney dysfunction as determined by a subsequent survival study and histopathological analysis. This analysis of both the light scattering and autofluorescence images suggests that changes in tissue microstructure, fluorophore emission, and blood absorption spectral characteristics, coupled with vascular response, contribute to the behavior of the observed signal, which may be used to obtain tissue functional information and offer the ability to predict posttransplant kidney function.

59 BASIC BIOLOGICAL SCIENCES↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

Stability of CIGS Solar Cells and Component Materials Evaluated by a Step-Stress Accelerated Degradation Test Method: Preprint

A step-stress accelerated degradation testing (SSADT) method was employed for the first time to evaluate the stability of CuInGaSe2 (CIGS) solar cells and device component materials in four Al-framed test structures encapsulated with an edge sealant and three kinds of backsheet or moisture barrier film for moisture ingress control. The SSADT exposure used a 15 degrees C and then a 15% relativehumidity (RH) increment step, beginning from 40 degrees C/40%RH (T/RH = 40/40) to 85 degrees C/70%RH (85/70) as of the moment. The voluminous data acquired and processed as of total DH = 3956 h with 85/70 = 704 h produced the following results. The best CIGS solar cells in sample Set-1 with a moisture-permeable TPT backsheet showed essentially identical I-V degradation trend regardless of theAl-doped ZnO (AZO) layer thickness ranging from standard 0.12 um to 0.50 um on the cells. No clear 'stepwise' feature in the I-V parameter degradation curves corresponding to the SSADT T/RH/time profile was observed. Irregularity in I-V performance degradation pattern was observed with some cells showing early degradation at low T/RH < 55/55 and some showing large Voc, FF, and efficiency degradation due to increased series Rs (ohm-cm2) at T/RH = 70/70. Results of (electrochemical) impedance spectroscopy (ECIS) analysis indicate degradation of the CIGS solar cells corresponded to increased series resistance Rs (ohm) and degraded parallel (minority carrier diffusion/recombination) resistance Rp, capacitance C, overall time constant Rp*C, and 'capacitor quality' factor (CPE-P), whic were related to the cells' p-n junction properties. Heating at 85/70 appeared to benefit the CIGS solar cells as indicated by the largely recovered CPE-P factor. Device component materials, Mo on soda lime glass (Mo/SLG), bilayer ZnO (BZO), AlNi grid contact, and CdS/CIGS/Mo/SLG in test structures with TPT showed notable to significant degradation at T/RH = 70/70. At T/RH = 85/70, substantial blistering of BZO layers on CIGS cell pieces was observed that was not seen on BZO/glass, and a CdS/CIGS sample displayed a small darkening and then flaking feature. Additionally, standard AlNi grid contact was less stable than thin Ni grid contact at T/RH = 70/70. The edge sealant and moisture-blocking films were effective to block moisture ingress, as evidenced by the good stability of most CIGS solar cells and device components at T/RH = 85/70 for 704 h, and by preservation of the initial blue color on the RH indicator strips. The SSADT experiment is ongoing to be completed at T/RH = 85/85.

14 SOLAR ENERGY↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

A deep UV trigger for ground-state ring-opening dynamics of 1,3-cyclohexadiene

We explore the photo-induced kinetics of 1,3-cyclohexadiene upon excitation at 200 nm to the 3p state by ultrafast time-resolved, gas-phase x-ray scattering using the Linac Coherent Light Source. Analysis of the scattering anisotropy reveals that the excitation leads to the 3px and 3py Rydberg electronic states, which relax to the ground state with a time constant of 208 ± 11 fs. In contrast to the well-studied 266 nm excitation, at 200 nm the majority of the molecules (76 ± 3%) relax to vibrationally hot cyclohexadiene in the ground electronic state. A subsequent reaction on the ground electronic state surface leads from the hot cyclohexadiene to 1,3,5-hexatriene, with rates for the forward and backward reactions of 174 ± 13 and 355 ± 45 ps, respectively. The scattering pattern of the final hexatriene product reveals a thermal distribution of rotamers about the carbon-carbon single bonds.