Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well-shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

Signal processing applied to photothermal techniques for materials characterization

There is a need to make noncontact measurements of material characteristics in the microgravity environment. Photothermal and photoacoustics techniques offer one approach for attaining this capability since lasers can be used to generate the required thermal or acoustic signals. The perturbations in the materials that can be used for characterization can be detected by optical reflectance, infrared detection or laser detection of photoacoustics. However, some of these laser techniques have disadvantages of either high energy pulsed excitation or low signal-to-noise ratio. Alternative signal processing techniques that have been developed can be applied to photothermal or photoacoustic instrumentation. One fully coherent spread spectrum signal processing technique is called time delay spectrometry (TDS). With TDS the system is excited using a combined frequency-time domain by employing a linear frequency sweep excitation function. The processed received signal can provide either frequency, phase or improved time resolution. This signal processing technique was shown to outperform other time selective techniques with respect to noise rejection and was recently applied to photothermal instrumentation. The technique yields the mathematical equivalent of pulses yet the input irradiances are orders of magnitude less than pulses with the concomitant reduction in perturbation of the sample and can increase the capability of photothermal methods for materials characterization.

Rooney, James A.↗

Magnetic pulsations at the quasi-parallel shock

The plasma and field properties of large-amplitude magnetic field pulsatins upstream from the quasi-parallel region of the earth's bow shock are examined in high time resolution using data from ISEE 1 and 2. The relative timing of the magnetic field profiles observed at the two spacecraft shows that some of the pulsations are convecting antisunward across the spacecraft while others are brief out/in motions of bow shock across the spacecraft. Pulsations with both timing signatures are the site of slowing and heating of the solar wind plasma. The ions tend to be only weakly heated in the convecting pulsations, while within the out/in pulsations the ion heating can be quite substantial but variable. This variation occurs not only from pulsation to pulsation but also from point to point within a given pulsation. In general, the hottest distributions within the out/in pulsations tend to occur in regions of lower density and field strength. Magnetic pulsations bear a number of similarities to previously identified hot diamagnetic cavity events as well as to more durable crossings of the quasi-parallel shock itself. These various phenomena may be different manifestations of the same basic physical processes, in particular the coupling of coherently reflected ions to the solar wind beam.

Thomsen, M. F.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

Remote Sensing of Cloud Properties using Ground-based Measurements of Zenith Radiance

An extensive verification of cloud property retrievals has been conducted for two algorithms using zenith radiances measured by the Atmospheric Radiation Measurement (ARM) Program ground-based passive two-channel (673 and 870 nm) Narrow Field-Of-View Radiometer. The underlying principle of these algorithms is that clouds have nearly identical optical properties at these wavelengths, but corresponding spectral surface reflectances (for vegetated surfaces) differ significantly. The first algorithm, the RED vs. NIR, works for a fully three-dimensional cloud situation. It retrieves not only cloud optical depth, but also an effective radiative cloud fraction. Importantly, due to one-second time resolution of radiance measurements, we are able, for the first time, to capture detailed changes in cloud structure at the natural time scale of cloud evolution. The cloud optical depths tau retrieved by this algorithm are comparable to those inferred from both downward fluxes in overcast situations and microwave brightness temperatures for broken clouds. Moreover, it can retrieve tau for thin patchy clouds, where flux and microwave observations fail to detect them. The second algorithm, referred to as COUPLED, couples zenith radiances with simultaneous fluxes to infer 2. In general, the COUPLED and RED vs. NIR algorithms retrieve consistent values of tau. However, the COUPLED algorithm is more sensitive to the accuracies of measured radiance, flux, and surface reflectance than the RED vs. NIR algorithm. This is especially true for thick overcast clouds where it may substantially overestimate z.

Chiu, J. Christine↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

47 OTHER INSTRUMENTATION↗

Design and Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar flare gamma-ray and hard x ray imaging with the GRID-on-a-balloon

A primary scientific objective for solar flare research during the rapidly approaching maximum in solar activity is the imaging of gamma-ray and hard x ray sources of solar flare emissions. These goals will be pursued by the Gamma Ray Imaging Device (GRID) instrument, one of three instruments recently selected for NASA's Max '91 Solar Balloon Program. The GRID instrument is based on the technique of Fourier transform imaging and utilizes scanning modulation grid collimator optics to provide full-Sun imaging with 1.9-arcsecond resolution over the energy range from 20 to 700 keV at time resolutions from 0.1 to 2 s. The GRID telescope will employ 32 subcollimators, each composed of a matched pair of high-Z collimator grids separated by 5.2 meters and a phoswich scintillation spectrometer detector having no spatial resolution. The subcollimators and integrally-mounted fine aspect system are contained within a telescope canister which will be pointed to 0.1 degree accuracy and cyclically scanned to produce source modulation. The 32 subcollimators provide a uniform distribution of grid slit orientations and a logarithmic distribution of slit spacings corresponding to angular dimensions of 1.9 arcseconds to several arcminutes. The instrument is several orders of magnitude more sensitive than the HXIS instrument on the Solar Maximum Mission (SMM) and nearly 10 times more sensitive than any similar instrument scheduled to fly during the next solar maximum. The payload, designed for long-duration high-altitude balloon capability, is scheduled for its first science flight (8 to 14 days duration) from the Antarctic in January of 1992.

Orwig, Larry E.↗

Third generation earth radiation budget measurements; ERBE in the context of earlier systems

The Earth Radiation Budget Experiment (ERBE) observations are just becoming available for scientific use. These represent the third generation of measurements with steadily improving accuracy and resolution. Beginning in the 1960's observations by spherical detectors established the mean albedo of the Earth near 30 percent in substantial variance from presatellite estimates. The Nimbus 6 and 7 wide field of view ERB measurements represent a long-term climatology of measurements at 1000 km resolution. The ERBE measurements introduce higher accuracy and higher space and time resolution result. Comparisons will be presented of several April ERB measurements to illustrate what this improvement in resolution and accuracy can yield. Simultaneous ERBE and Nimbus 7 measurements for April 1985 show nearly identical results on the large scale. Comparison of measurements of direct solar energy from ERBE, Solar Max Mission and Nimbus 7 suggest a 'solar constant' value of 1368 w/sq m for the 1979 to 1986 period. The long-term record of earth radiation budget (Aprils from 1976 to 1985) over large regions is shown to have interannual variation of plus or minus 20 to 30 w/sq. m. The new ERBE data will allow this climate record measurement to continue.

Vonderhaar, Thomas H.↗

The precision of today's satellite laser ranging systems

Recent improvements in the accuracy of modern satellite laser ranging (SLR) systems are strengthened by the new capability of many instruments to track an increasing number of geodetic satellite targets without significant scheduling conflict. This will allow the refinement of some geophysical parameters, such as solid Earth tidal effects and GM, and the improved temporal resolution of others, such as Earth orientation and station position. Better time resolution for the locations of fixed observatories will allow us to monitor more subtle motions at the stations, and transportable systems will be able to provide indicators of long term trends with shorter occupations. If we are to take advantage of these improvements, care must be taken to preserve the essential accuracy of an increasing volume of range observations at each stage of the data reduction process.

Dunn, Peter J.↗

Compute Element and Interface Box for the Hazard Detection System

The Autonomous Landing and Hazard Avoidance Technology (ALHAT) program is building a sensor that enables a spacecraft to evaluate autonomously a potential landing area to generate a list of hazardous and safe landing sites. It will also provide navigation inputs relative to those safe sites. The Hazard Detection System Compute Element (HDS-CE) box combines a field-programmable gate array (FPGA) board for sensor integration and timing, with a multicore computer board for processing. The FPGA does system-level timing and data aggregation, and acts as a go-between, removing the real-time requirements from the processor and labeling events with a high resolution time. The processor manages the behavior of the system, controls the instruments connected to the HDS-CE, and services the "heavy lifting" computational requirements for analyzing the potential landing spots.

Villalpando, Carlos Y.↗

The ACS LCID project. X. the star formation history of IC 1613: Revisiting the over-cooling problem

We present an analysis of the star formation history (SFH) of a field near the half-light radius in the Local Group dwarf irregular galaxy IC 1613 based on deep Hubble Space Telescope Advanced Camera for Surveys imaging. Our observations reach the oldest main sequence turn-off, allowing a time resolution at the oldest ages of ∼1 Gyr. Our analysis shows that the SFH of the observed field in IC 1613 is consistent with being constant over the entire lifetime of the galaxy. These observations rule out an early dominant episode of star formation in IC 1613. We compare the SFH of IC 1613 with expectations from cosmological models. Since most of the mass is in place at early times for low-mass halos, a naive expectation is that most of the star formation should have taken place at early times. Models in which star formation follows mass accretion result in too many stars formed early and gas mass fractions that are too low today (the 'over-cooling problem'). The depth of the present photometry of IC 1613 shows that, at a resolution of ∼1 Gyr, the star formation rate is consistent with being constant, at even the earliest times, which is difficult to achieve in models where star formation follows mass assembly.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrafast Adsorbate Excitation Probed with Subpicosecond-Resolution X-Ray Absorption Spectroscopy

We use a pump-probe scheme to measure the time evolution of the C K-edge x-ray absorption spectrum from CO/Ru(0001) after excitation by an ultrashort high-intensity optical laser pulse. Because of the short duration of the x-ray probe pulse and precise control of the pulse delay, the excitation-induced dynamics during the first picosecond after the pump can be resolved with unprecedented time resolution. By comparing with density functional theory spectrum calculations, we find high excitation of the internal stretch and frustrated rotation modes occurring within 200 fs of laser excitation, as well as thermalization of the system in the picosecond regime. The ~100 fs initial excitation of these CO vibrational modes is not readily rationalized by traditional theories of nonadiabatic coupling of adsorbates to metal surfaces, e.g., electronic frictions based on first order electron-phonon coupling or transient population of adsorbate resonances. Finally, we suggest that coupling of the adsorbate to nonthermalized electron-hole pairs is responsible for the ultrafast initial excitation of the modes.

47 OTHER INSTRUMENTATION↗