Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Measurement of D 0 -meson + hadron two-dimensional angular correlations in Au + Au collisions at s N N = 200 GeV

Open heavy flavor hadrons provide unique probes of the medium produced in ultra-relativistic heavy-ion collisions. Due to their increased mass relative to light-flavor hadrons, long lifetime, and early production in hard-scattering interactions, they provide access to the full evolution of the partonic medium formed in heavy-ion collisions. This paper reports two-dimensional (2D) angular correlations between neutral D-mesons and unidentified charged particles produced in minimum-bias Au+Au collisions at s N N = 200 GeV. D 0 and D 0 ¯ mesons are reconstructed via their weak decay to K ∓ π ± using the Heavy Flavor Tracker (HFT) in the Solenoidal Tracker at RHIC (STAR) experiment. Correlations on relative pseudorapidity and azimuth (Δη,ΔΦ) are presented for peripheral, mid-central and central collisions with D 0 transverse momentum from 2 to 10 GeV/c. Attention is focused on the 2D peaked correlation structure near the triggered D 0 -meson, the {\em near-side} (NS) peak, which serves as a proxy for a charm-quark containing jet. The correlated NS yield of charged particles per D 0 -meson and the 2D widths of the NS peak increase significantly from peripheral to central collisions. These results are compared with similar correlations using unidentified charged particles, consisting primarily of light-flavor hadrons, at similar trigger particle momenta. Similar per-trigger yields and widths of the NS correlation peak are observed. Here, the present results provide additional evidence that D 0 -mesons undergo significant interactions with the medium formed in heavy-ion collision and show, for the first time, significant centrality evolution of the NS 2D peak in the correlations of particles associated with a heavy-flavor hadron produced in these collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic measurements of identified particle spectra in pp, d+Au, and Au+Au collisions at the STAR detector

Identified charged-particle spectra of {pi}{sup {+-}}, K{sup {+-}}, p, and p at midrapidity (|y|<0.1) measured by the dE/dx method in the STAR (solenoidal tracker at the BNL Relativistic Heavy Ion Collider) time projection chamber are reported for pp and d+Au collisions at {radical}(s{sub NN})=200 GeV and for Au+Au collisions at 62.4, 130, and 200 GeV. Average transverse momenta, total particle production, particle yield ratios, strangeness, and baryon production rates are investigated as a function of the collision system and centrality. The transverse momentum spectra are found to be flatter for heavy particles than for light particles in all collision systems; the effect is more prominent for more central collisions. The extracted average transverse momentum of each particle species follows a trend determined by the total charged-particle multiplicity density. The Bjorken energy density estimate is at least several GeV/fm{sup 3} for a formation time less than 1 fm/c. A significantly larger net-baryon density and a stronger increase of the net-baryon density with centrality are found in Au+Au collisions at 62.4 GeV than at the two higher energies. Antibaryon production relative to total particle multiplicity is found to be constant over centrality, but increases with the collision energy. Strangeness production relative to total particle multiplicity is similar at the three measured RHIC energies. Relative strangeness production increases quickly with centrality in peripheral Au+Au collisions, to a value about 50% above the pp value, and remains rather constant in more central collisions. Bulk freeze-out properties are extracted from thermal equilibrium model and hydrodynamics-motivated blast-wave model fits to the data. Resonance decays are found to have little effect on the extracted kinetic freeze-out parameters because of the transverse momentum range of our measurements. The extracted chemical freeze-out temperature is constant, independent of collision system or centrality; its value is close to the predicted phase-transition temperature, suggesting that chemical freeze-out happens in the vicinity of hadronization and the chemical freeze-out temperature is universal despite the vastly different initial conditions in the collision systems. The extracted kinetic freeze-out temperature, while similar to the chemical freeze-out temperature in pp, d+Au, and peripheral Au+Au collisions, drops significantly with centrality in Au+Au collisions, whereas the extracted transverse radial flow velocity increases rapidly with centrality. There appears to be a prolonged period of particle elastic scatterings from chemical to kinetic freeze-out in central Au+Au collisions. The bulk properties extracted at chemical and kinetic freeze-out are observed to evolve smoothly over the measured energy range, collision systems, and collision centralities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identified particle production, azimuthal anisotropy, and interferometry measurements in Au+Au collisions at sq root(s{sub NN})=9.2 GeV

We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au+Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at sq root(s{sub NN})=9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum <p{sub T}>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar sq root(s{sub NN}) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, <p{sub T}>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for sq root(s{sub NN})=200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking f(R) cosmology

Metric f(R) gravity theories are conformally equivalent to models of quintessence in which matter is coupled to dark energy. We derive a condition for a stable tracker solution for metric f(R) gravity in the Einstein frame. We find that tracker solutions with -0.361<{omega}{sub {phi}}<1 exist if 0<{gamma}<0.217 and (d/dt)lnf{sup '}(R-tilde)>0, where {gamma}=(V{sub {phi}}{sub {phi}}V/V{sub {phi}}{sup 2}) is a dimensionless function, {omega}{sub {phi}} is the equation of state parameter of the scalar field, and R-tilde refers to the Jordan frame's curvature scalar. Also, we show that there exists f(R-tilde) gravity models which have tracking behavior in the Einstein frame and so the curvature of space-time is decreasing with time while they lead to the solutions in the Jordan frame that the curvature of space-time can be increasing with time.

99 GENERAL AND MISCELLANEOUS↗

Measurement of the inclusive isolated prompt photon cross section in pp collisions at √s=7 TeV with the ATLAS detector

A measurement of the cross section for the inclusive production of isolated prompt photons in pp collisions at a center-of-mass energy √s=7 TeV is presented. The measurement covers the pseudorapidity ranges |η γ |<1.37 and 1.52≤|η γ |<1.81 in the transverse energy range 15≤E γ T <100 GeV. The results are based on an integrated luminosity of 880 nb -1 , collected with the ATLAS detector at the Large Hadron Collider. Photon candidates are identified by combining information from the calorimeters and from the inner tracker. Residual background in the selected sample is estimated from data based on the observed distribution of the transverse isolation energy in a narrow cone around the photon candidate. The results are compared to predictions from next-to-leading-order perturbative QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon strip detectors for the ATLAS upgrade

The Large Hadron Collider at CERN will extend its current physics program by increasing the peak luminosity by one order of magnitude. For ATLAS, one of the two general-purpose experiments of the LHC, an upgrade scenario will imply the complete replacement of its internal tracker due to the harsh conditions in terms of particle rates and radiation doses. New radiation-hard prototype n-in-p silicon sensors have been produced for the short-strip region of the future ATLAS tracker. The sensors have been irradiated up to the fluences expected in the high-luminous LHC collider. This paper summarizes recent results on the performance of the irradiated n-in-p detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vehicle Tracking with Crop-based Detection

End-to-end production of vehicle tracking data from video in real-time and with high accuracy remains a challenging problem due to the computational cost of object detection on each frame. In this work we present Tracking with Crop-based Detection, a method for speeding object tracking in constrained contexts (with stable cameras and relatively-predictable object motion) such as vehicle traffic monitoring. We leverage this context to provide a strong prior for object locations, which we use to 1.) boost detection speed by detecting objects only in regions corresponding to object priors on most frames and 2.) inform the selection of the detector output for each object. We evaluate Crop-based Detection as an extension to the KIOU object tracker (Crop-KIOU) on the UA-DETRAC dataset. The proposed tracker outperforms all other reported algorithms in terms of PR-MOTA, PR-MOTP, and mostly tracked objects on the UA-DETRAC benchmark, establishing a new state-of-the-art. Relative to tracking by detection with KIOU, Crop-KIOU achieves a 26% higher frame-rate and increases accuracy. Furthermore, Tracking with Crop-based Detection can be combined with frame skipping; we show a 149% increase in framerate relative to KIOU with no decrease in accuracy using this combination of methods.

Gloudemans, Derek↗

Thermal design of the Mu2e detector solenoid

The reference design for a superconducting detector solenoid (DS) for the Mu2e experiment has been completed. In this study, the main functions of the DS are to provide a graded field in the region of the stopping target, which ranges from 2 to 1 T and a uniform precision magnetic field of 1 T in a volume large enough to house a tracker downstream of the stopping target. The inner diameter of the magnet cryostat is 1.9 m and the length is 10.9 m. The gradient section of the magnet is about 4 m long and the spectrometer section with a uniform magnetic field is about 6 m long. The inner cryostat wall supports the stopping target, tracker, calorimeter and other equipment installed in the DS. This warm bore volume is under vacuum during operation. It is sealed on one end by the muon beam stop, while it is open on the other end where it interfaces with the Transport Solenoid. The operating temperature of the magnetic coil is 4.7 K and is indirectly cooled with helium flowing in a thermosiphon cooling scheme. This paper describes the thermal design of the solenoid, including the design aspects of the thermosiphon for the coil cooling, forced flow cooling of the thermal shields with 2 phase LN2 (Liquid Nitrogen) and the transient studies of the cool down of the cold mass as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 {+-} 0.44 mm (Mean {+-} STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 {+-} 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-434: Evaluation of the Machine Performance Check (MPC) Program for Truebeam 2.0

Purpose: Machine Performance Check (MPC) is a software application used to verify that the TrueBeam machine is operating within major specifications prior to treatment. Used in combination with a phantom named Isocal, it verifies beam output, beam uniformity, treatment isocenter size, coincidence of treatment and imaging isocenters, positioning accuracy of kV and MV imaging systems, accuracy of collimator and gantry rotation angle, positioning accuracy of jaws and MLC leafs, and couch positioning. The tests can be performed semi-automatically and requires approximately 10 minutes of machine time. It is the purpose of this study to report the performance of this program. Methods: A pre-release version of the MPC tool was installed on a Truebeam linac with 6D couch at our center. Baseline beam output measurements were taken for 5 photon beams (6–15 MV, 6 FFF, 10 FFF) and 5 electron beams (6–20 MeV). Deviations from the baseline output were subsequently recorded for several days and compared against independent measurements from a PTW farmer chamber and our daily QA device (Fluke Biomedical Tracker) as part of an ongoing evaluation. Results: The beam output deviations between the MPC and the PTW chamber measurements were within ±0.7% for photons beams and ±1.0% for electrons beams. This was similar to the tracker performance. There were some isolated incidents where the MPC measurements had unexplained spikes (>3%) that disappeared on a repeat measurement. MPC was also able to detect maximum positioning errors in the jaws (1.12 mm), MLCs (1.14 mm), and couch roll (0.11°). Conclusion: Overall, the ability of the MPC to monitor linac output stability was comparable to that of ionization chamber-based measurements. MPC also provided fast daily mechanical tests not currently available in the clinic. How best to utilize this previously unavailable data is still under investigation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-165: Daily QA Analysis for Spot Scanning Beamline

Purpose: The dosimetric results of our daily quality assurance over the last 8 years for discrete pencil beam scanning proton therapy will be presented. Methods: To perform the dosimetric checks, a multi-ion chamber detector is used, which consists of an array of 5 single parallel plate ion chambers that are aligned as a cross separated by 10cm each. The Tracker is snapped into a jig, which is placed on the tabletop. Different amounts of Solid Water buildup are added to shift the dose distribution. The dosimetric checks consist of 3 parts: position check, range check and volume dose check. Results: The average deviation of all position-check data were 0.2±1.3%. For the range check, the average deviation was 0.1%±1.2%, which also corresponds to a range stability of better than 1 mm over all measurements. The volumetric dose output readings were all within ±1% with the exception of 2 occasions when the cable to the dose monitor was being repaired. Conclusion: Morning QA using the Tracker device gives very stable dosimetric readings but is also sensitive to mechanical and output changes in the proton therapy delivery system.

07 ISOTOPE AND RADIATION SOURCES↗

Coordinate detectors based on thin-wall drift tubes

Design features and basic parameters of the detectors based on straw trackers are reviewed using the example of the studies and development of trackers in a number of operating and proposed accelerator experimental facilities. The results of methodological studies aimed at qualitatively improving the spatial/time resolution and high rate capability of the detector and enhancing the performance capabilities of such detectors used for particle detection in a high multiplicity environment (and in high-luminosity experiments) are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS tracking performance results from early LHC operation

The first LHC pp collisions at centre-of-mass energies of 0.9 and 2.36 TeV were recorded by the CMS detector in December 2009. The trajectories of charged particles produced in the collisions were reconstructed using the all-silicon Tracker and their momenta were measured in the 3.8 T axial magnetic field. Results from the Tracker commissioning are presented including studies of timing, efficiency, signal-to-noise, resolution, and ionization energy. Reconstructed tracks are used to benchmark the performance in terms of track and vertex resolutions, reconstruction of decays, estimation of ionization energy loss, as well as identification of photon conversions, nuclear interactions, and heavy-flavour decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Artifact Analysis of Self-Admitted Technical Debt in Scientific Software

Context: Self-admitted technical debt (SATD) occurs when developers acknowledge shortcuts in code. In scientific software (SSW), such debt poses unique risks to the validity and reproducibility of results. Objective: This study aims to identify, categorize, and evaluate scientific debt, a specialized form of SATD in SSW, and assess the extent to which traditional SATD categories capture these domain-specific issues. Method: We conduct a multi-artifact analysis across code comments, commit messages, pull requests, and issue trackers from 23 open-source SSW projects. We construct and validate a curated dataset of scientific debt, develop a multi-source SATD classifier to guide SATD management, and conduct a practitioner validation to assess the practical relevance of scientific debt. Results: Our classifier performs strongly across 900,358 artifacts from 23 SSW projects. SATD is most prevalent in pull requests and issue trackers, underscoring the value of multi-artifact analysis. Models trained on traditional SATD often miss scientific debt, emphasizing the need for its explicit detection in SSW. Practitioner validation confirmed that scientific debt is both recognizable and useful in practice. Conclusions: Scientific debt represents a unique form of SATD in SSW that that is not adequately captured by traditional categories and requires specialized identification and management. Our dataset, classification analysis, and practitioner validation results provide the first formal multi-artifact perspective on scientific debt, highlighting the need for tailored SATD detection approaches in SSW.

Melin, Eric [Boise State University]↗

Real Time Assays for Quantifying Cytotoxicity with Single Cell Resolution

A new live cell-based assay platform has been developed for the determination of complement dependent cytotoxicity (CDC), antibody dependent cellular cytotoxicity (ADCC), and overall cytotoxicity in human whole blood. In these assays, the targeted tumor cell populations are first labeled with fluorescent Cell Tracker dyes and immobilized using a DNA-based adhesion technique. This allows the facile generation of live cell arrays that are arranged arbitrarily or in ordered rectilinear patterns. Following the addition of antibodies in combination with serum, PBMCs, or whole blood, cell death within the targeted population can be assessed by the addition of propidium iodide (PI) as a viability probe. The array is then analyzed with an automated microscopic imager. The extent of cytotoxicity can be quantified accurately by comparing the number of surviving target cells to the number of dead cells labeled with both Cell Tracker and PI. Excellent batch-to-batch reproducibility has been achieved using this method. In addition to allowing cytotoxicity analysis to be conducted in real time on a single cell basis, this new assay overcomes the need for hazardous radiochemicals. Fluorescently-labeled antibodies can be used to identify individual cells that bear the targeted receptors, but yet resist the CDC and ADCC mechanisms. This new approach also allows the use of whole blood in cytotoxicity assays, providing an assessment of antibody efficacy in a highly relevant biological mixture. Given the rapid development of new antibody-based therapeutic agents, this convenient assay platform is well-poised to streamline the drug discovery process significantly.

59 BASIC BIOLOGICAL SCIENCES↗

Marine ARM GPCI Investigation of Clouds Sunshine Pyranometer (SPN1) Field Campaign Report

From the SPN1 manual, the SPN1 Sunshine Pyranometer is one sensor with three output channels: 1) total (global) solar radiation, 2) diffuse radiation, and 3) sunshine status. The SPN1 measures short-wave radiation between 400nm and 2700nm in W.m-2. The Direct beam component of solar radiation can be calculated from the Total minus the Diffuse component. The Sunshine status output indicates whether the energy in the direct beam exceeds the World Meteorological Organization (WMO) standard threshold value of 120 W.m-2, using an algorithm based on the Total radiation, and the ratio of Total to Diffuse radiation. The radiation outputs have a cosine-corrected response. The advantages of the SPN1 are 1) It matches the WMO ‘Good Quality’ pyranometer classification. 2) It requires no shadow band or solar tracker. 3) There are no moving parts. 4) It does not need to be adjusted or repositioned to track the sun—a distinct advantage over shade rings or mechanical trackers. 5) It does not need to be oriented towards north. It will work accurately in any orientation as long as it is mounted horizontally. 6) It does not require knowledge of the latitude or longitude, and can be used at any latitude or longitude. 7) It measures sunshine hours as well as Total and Diffuse radiation. 8) The built-in heater allows use in wet or icy conditions.

54 ENVIRONMENTAL SCIENCES↗