Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

On the roles of welding residual stresses in determination of fracture toughness in austenitic stainless steel SUS 304 pipeline girth welds

Welding residual stresses especially the high tensile stresses are proved to have negative impacts on the fatigue and fracture behaviors of welded structures. In this study, a virtual fabrication of test specimens from welding process to specimen preparation was carried out by numerical simulation. An austenitic stainless steel multi-pass pipe welding was simulated by transient thermal–mechanical finite element analysis, the residual stresses were then mapped into the test specimen to evaluate fracture toughness. The findings in this study confirmed that, residual stress can be high in a sub-sized compact tensile specimen, which may accelerate or hinder the crack propagation during actual fatigue and fracture tests as reported in recent years. The influence of the cutting location and orientation of the specimen on fracture performance was investigated systematically to provide a fundamental understanding of welding residual stress and necessary insights into the specimen preparation procedure. Considering the limitation of measuring techniques and the complexity of the stress distribution, the developed numerical model can be a very useful tool to elucidate the stress evolution and quantify the effect of remaining welding stress on fracture toughness.

Fracture behavior↗

Test Cases for Wind Power Plant Dynamic Models on Real-Time Digital Simulator: Preprint

The objective of this paper is to present test cases for wind turbine generator and wind power plant models commonly used during commissioning of wind power plants to ensure grid integration compatibility. In this paper, different types of wind power plant models based on the Western Electricity Coordinating Council Wind Generator Modeling Group's standardization efforts are implemented on areal-time digital simulator, and different test cases are used to gauge their grid integration capability. The low-voltage ride through and reactive power support capability and limitations of wind turbine generators under different grid conditions are explored. Several types of transient events (e.g., symmetrical and unsymmetrical faults, frequency dips) are included in the test cases. Thedifferences in responses from different types of wind turbine are discussed in detail.

17 WIND ENERGY↗

Combining genome-wide association studies and expression quantitative trait nucleotide mapping with molecular and genetic validations to identify transcriptional networks regulating drought tolerance in Populus

Objectives: (i). To deploy a large-scale experimental drought trial for up to 1000 unique genotypes of Populus equipping the sites with controlled irrigation and drought treatments that are fully automated and monitored. FULLY COMPLETED (ii) To test the hypothesis that a suite of traits identified for drought tolerance in P. nigra can be measured in drought and control treatments in the wide germplasm collection of P. trichocarpa. FULLY COMPLETED (iii) To use established and novel GWAS model approaches to identify gene loci linked to drought tolerance traits on interest in P. trichocarpa. FULLY COMPLETED (iv) To undertake comparative analysis of GWAS results for drought tolerance traits in P. nigra and P. trichocarpa. PARTIALLY COMPLETED – remains active (v) Using RNAseq in P. trichocarpa, in droughted and control treatments to identify cis- and trans-regulated eQTN. FULLY COMPLETED (vi) Validate up to 50 cis-QTNs, from network hubs using transient protoplast assays. FULLY COMPLETED (vii) To establish Agrobacterium-based gene editing protocols in Populus. FULLY COMPLETED (viii) To utilize early leads from previous research to investigate at least 6 candidate genes for drought tolerance in Populus. FULLY COMPLETED (ix) To validate up to 20 candidate genes for drought tolerance in P. trichocarpa refined from the long-list tested in the transient assays for cis-acting hub gene targets. PARTIALLY COMPLETED- remains active.

60 APPLIED LIFE SCIENCES↗

NEUP Final Report: Analysis of Thermal Transients for a Sodium-CO 2 Heat Exchanger

The design of heat exchangers for use in a supercritical carbon dioxide (sCO 2 ) Brayton cycle power converter must provide for acceptable performance for duty cycle events encompassing anticipated transients and postulated accidents. Argonne National Laboratory participated in the NEUP project, “Thermal Hydraulic and Structural Testing and Modeling of Compact Diffusion-Bonded Heat Exchangers for Supercritical CO 2 Brayton Cycle” with the task of conducting a comprehensive analysis of thermal transients for sCO 2 cycle heat exchangers, with emphasis on the sodium-to-CO 2 heat addition heat exchanger. A range of transients, from normal operation to severe accidents, were simulated with the coupled PDC and SAS4A/SASSYS-1 system level dynamic analysis computer codes. For each transient, the calculated change in the heat exchanger wall temperature is determined as a measure of the thermal loading. In addition, an analysis to find an equivalent helium-CO 2 heat exchanger was carried out to facilitate testing with helium rather than sodium on the hot side.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation of fuel temperature effects on transient needle motion and injection velocity of solenoid type diesel injector

Real driving emission (RDE) test conducted in sub-zero temperature conditions has been acting as a severe emission regulation over the existing test methods for diesel engines. In order to cope with this tightened regulation, many studies have been conducted to interpret the factors causing the deteriorated diesel engine combustion in cold operation conditions. The deteriorated fuel injection performance has been regarded as one of the key contributing factors but the governing mechanisms are not thoroughly understood so far. This study aims to provide a comprehensive understanding of the effects of fuel temperature including sub-zero conditions on fuel injection performance by measuring the transient needle motion and injection velocity of a diesel injector using synchrotron X-ray imaging techniques. Here, the factors causing the deteriorated injector performance and their contributions are discussed thoroughly based on the results. The results showed that the injection duration was shortened as the fuel temperature decreased as a result of decreased needle opening speed and increased needle closing speed. The increase of fuel viscosity and bulk modulus was discussed as the main factors associated with these results. The total injection mass was reduced by lowering the fuel temperature not only by the shortened injection duration but also by the decreased injection velocity. These factors exerted near equivalent contribution to the reduced injection mass at low fuel temperatures.

42 ENGINEERING↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time response of Cd{sub 0.9}Zn{sub 0.1}Te crystals under transient and pulsed irradiation

A CdZnTe detector based on high-quality Cd{sub 0.9}Zn{sub 0.1}Te crystals was developed and tested as a monitor in high-intensity radiation fields. The current-voltage measurements were performed using thermally evaporated Au contacts deposited on the crystals, which revealed resistivity of 10{sup 10}{Omega}{center_dot}cm. Typical leakage current for the planar devices was {approx}3 nA for a field strength of 1000 V{center_dot}cm{sup -1}. The test results show that the CdZnTe detector has a fast time response, with a rise time of approximately 2 ns, when exposed to transient and pulsed irradiation of X-rays or electron beams. The decay of current curves is observed and discussed according to charge carrier trapping effects and space-charge accumulation mechanisms. It is suggested that the current decreases quickly with strengthening of the electric field, possibly because of charge de-trapping.

36 MATERIALS SCIENCE↗

Energy Exascale Earth System Model v2.0.2

Second patch release of v2.0.0 Changes since v2.0.1 [Important change] Add and update SSP370 and SSP585 cases, add tests, fix use-case files, Change ocean and sea-ice IC for ARRM60to10. [EAM] allow thetaxx as a CAM_TARGET, enable northamericax4v1pg2_WC14to60E2r3 for AMIP, fix ndrop initialization, allow up to 15 history files. [EAMxx] allow use of readnl [EAM-MMF] allow transient SST case for C++ MMF, remove specific task/thread count for ESMT test, modify the variance transport diagnostic, reorg tests, [HOMME] Allow optional sponge layer. [ELM] add 2 land-atm compsets, update FATES to API 17.0.0, allow FATES sp mode, allow ELM harvest to drive FATES harvest, fix memleaks, reduce test build times, modified parameters for miscanthus and switchgrass based on calibration [MPAS-Ocean] turn on ocean BGC in BGC cases, fix interface locations for 60L PHC grid, add mode spec to conservation check streams, allow oRRS18to6v3 grid to run with JRA, update ocean and sea ice ICs for ARRM60to10 (needed for v2), GPU port of thickness tendency, add CMPASO-JRA1p4, [MPAS framework] Add new reproducible global sum module for MPAS components, Add mostRecentAccessTime attribute to streams [MPAS-landice] Update MALI version and Greenland mesh [MPAS-seaice] add single-cell test case, fix BGC restart, Adds omp critical directives for ice warnings seen on cori. [CIME] Fix component namelist creation bugs when NINST>1, add OpenACC, OpenMP and CXX GPU tests, fix nonBFB tests, stop using config_compilers, reduce ELM test build times with shared executable, update OpenMPI on Chrysalis. fix baseline handling, provenance handling with update to cime6.0.33, also use component-specific config_pes files and add the ones from master [Machine updates] cori modules after maint, Chrysalis to OpenMPI-4.1.3 [run_e3sm] replace default case name and group. [Externals] update SCORPIO to 1.3.2

ECP↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Design of Experiments for Dynamic Test Runs in Solvent-Based CO 2 Capture Pilot Plants

Test runs in the pilot plants consume significant resources, and therefore, the learning from test runs should be maximized. Test runs conducted in the pilot plants are often steady state. It takes several hours for reaching steady-state in the pilot plants, and thus, the duration of the test runs needs to be long even for collecting few steady-state data points. On the other hand, a large number of measurements can be collected through dynamic test runs in a short span of time. This paper presents a systematic design of dynamic experiments (DoDEs) for identifiability of model parameters, which is achieved by persistently exciting the inputs signals. A pseudorandom binary sequence (PRBS) is designed as the input signal for DoDE due to its efficiency in obtaining sufficient spectral content. However, due to the long sequence size of the PRBS signal, a Schroeder-phase input signal, which is a multisine signal, is also designed. Tests for both types of signals are run in the Pilot Solvent Test Unit (PSTU) at the National Carbon Capture Center in Wilsonville, Alabama. The transient data are used to solve dynamic data reconciliation and parameter estimation problem. The estimated parameters are found to be not only superior to those estimated from using data collected from hundreds of steady-state test runs in a nonreactive (air–water) system, but the parameters could be estimated by using the dynamic data collected for about 24 h from the pilot plant for the MEA-H 2 O–CO 2 system.

CO2 capture↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of Variation in Combustion Instability Amplitude in a Multi-Nozzle Can Combustor

In this work, we quantify the level of variation in unstable combustion oscillation amplitudes and identify the source of this variation in a multi-nozzle can combustor. At conditions where pollutant emissions are reduced, lean-premixed combustors can undergo thermoacoustic instability when pressure and heat release rate oscillations couple. A commonly used method for suppressing instability is fuel staging, which is a method where fuel is unevenly distributed between nozzles in a multi-nozzle combustor. Our work follows others who have characterized the effect of fuel staging on combustion instability and the mechanisms by which it works during both steady-state and transient operation. One of the outcomes from our previous work was that certain instability operating points display a high level of pressure oscillation amplitude variation. Instead of oscillating at a constant limit-cycle amplitude, the pressure oscillation amplitude varies significantly in time. In this work, we use the concept of permutation entropy to quantify the level of variation in the pressure fluctuation amplitude. We correlate the level of variation with a number of state variables over a range of operating conditions, 291 test cases in all. These state variables include mixture equivalence ratio; transient timescale, amplitude, and direction; hardware temperatures; gas temperatures; and thermoacoustic damping and growth rates. Significant pressure oscillation amplitude variation occurs when the thermoacoustic damping rate is low. The damping and growth rates can be low for a number of reasons, but they are highly correlated with the metal temperature of the centerbody, where the flames are anchored; lower temperatures result in lower damping rates during stable operation and lower growth rates during unstable operation. These results show the importance of the thermal boundary condition on the time-dependent behavior of the thermoacoustic instability.

Westfall, Seth↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmark Evaluation of TREAT Reactor M2 and M3 Transient Experiments

The objective of this project is to evaluate and produce TREAT reactor benchmarks under steady state and transient conditions. The benchmarks support the TREAT restart effort and are to be contributed to the International Reactor Physics Experiment Evaluation Project (IRPhEP) for inclusion in the International Handbook of Evaluated Reactor Physics Benchmark Experiments. The benchmark evaluation is performed using data generated during the “Power Calibration Experiment for test M2” and “IFR Safety Tests M2 and M3”. The evaluations are conducted using the high fidelity Serpent-OpenFOAM code system. Both the steady state and transient conditions of the M2 and M3 tests were investigated. Furthermore, TREAT has a graphitic core. Historical work has shown that the predictions of the outcomes of TREAT tests are highly sensitive to the graphite thermal neutron scattering cross sections. Therefore, in this project, thermal neutron scattering (i.e., S(α,β)) libraries of graphite, tailored to the specifics of the TREAT core, were generated and utilized in the evaluation

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of experimental and simulated critical heat flux tests with various cladding alloys: Sensitivity of iron-chromium-aluminum (FeCrAl) to heat transfer coefficients and material properties

In this paper we analyze the differences between previous transient critical heat flux (CHF) experiments using iron-chromium-aluminum (FeCrAl), Inconel 600, and stainless steel 316 (SS316) alloy test sections and best-estimate modeling results from widely-used nuclear engineering systems and subchannel analysis tools. FeCrAl is an Accident Tolerant Fuel (ATF) candidate cladding material. The thermal hydraulic performance and safety characteristics of FeCrAl are being evaluated to determine viability as a cladding material in Light Water Reactors (LWRs). In this study, the results of the CHF experiments conducted at atmospheric pressure and fixed inlet coolant temperature and mass flux are compared to models built in the fifth version of the Reactor Excursion and Leak Analysis Program (RELAP5-3D) and CTF, the modernized version of COBRA-TF developed by the Consortium for Advanced Simulation of LWRs (CASL). Results from RELAP5-3D and CTF showed differences from the experiments and from each other in predicting CHF. In the Inconel 600 case, both computational tools overpredicted CHF, which led to an underprediction in the tube outer surface temperature. In the SS316 and FeCrAl cases, CHF was underpredicted by the codes, leading to an overprediction of the tube outer surface temperature. To understand the discrepancies in CHF and post-CHF predictions, studies were performed using RELAP5-3D and RAVEN to determine the sensitivity of CHF and peak test section temperature, an analog to peak cladding temperature (PCT), to heat transfer coefficients, a CHF multiplier, and uncertainties in the thermal conductivity and volumetric heat capacity. We found that CHF depends most strongly on the CHF multiplier and thermophysical properties. A combination of these factors that produced the best match to the experiment based on CHF, PCT, and the total energy deposited into the tube was determined. The best match parameters were able to provide best-estimate predictions of the CHF and integral heat flux, but were still conservative when predicting the PCT. The best match set of parameters developed in this paper are intended only as a demonstration of an approach that could be applied in the future with a larger set of experiments to produce more accurate models of CHF and post-CHF behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intracore Natural Circulation Study in the High Temperature Test Facility

The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗