Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Identification of host response signatures of infection.

Biological weapons of mass destruction and emerging infectious diseases represent a serious and growing threat to our national security. Effective response to a bioattack or disease outbreak critically depends upon efficient and reliable distinguishing between infected vs healthy individuals, to enable rational use of scarce, invasive, and/or costly countermeasures (diagnostics, therapies, quarantine). Screening based on direct detection of the causative pathogen can be problematic, because culture- and probe-based assays are confounded by unanticipated pathogens (e.g., deeply diverged, engineered), and readily-accessible specimens (e.g., blood) often contain little or no pathogen, particularly at pre-symptomatic stages of disease. Thus, in addition to the pathogen itself, one would like to detect infection-specific host response signatures in the specimen, preferably ones comprised of nucleic acids (NA), which can be recovered and amplified from tiny specimens (e.g., fingerstick draws). Proof-of-concept studies have not been definitive, however, largely due to use of sub-optimal sample preparation and detection technologies. For purposes of pathogen detection, Sandia has developed novel molecular biology methods that enable selective isolation of NA unique to, or shared between, complex samples, followed by identification and quantitation via Second Generation Sequencing (SGS). The central hypothesis of the current study is that variations on this approach will support efficient identification and verification of NA-based host response signatures of infectious disease. To test this hypothesis, we re-engineered Sandia's sophisticated sample preparation pipelines, and developed new SGS data analysis tools and strategies, in order to pioneer use of SGS for identification of host NA correlating with infection. Proof-of-concept studies were carried out using specimens drawn from pathogen-infected non-human primates (NHP). This work provides a strong foundation for large-scale, highly-efficient efforts to identify and verify infection-specific host NA signatures in human populations.

Branda, Steven S.↗

SU-C-204-03: In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms

Purpose: To study if prompt gamma (PG) volume histograms created from PG images acquired during treatment delivery can be used to identify changes to beam range and tissue composition in response to proton radiotherapy. Methods: Monte Carlo simulations of a single field from a single treatment fraction (100 cGy) for prostate cancer were performed for the cases of: 1) an ideal patient setup, 1) a setup shift in the superior direction and 2) a reduction in oxygen concentration in the tumor. For each case, the 3 -Dimsional dose delivery and elemental PG emission in the patient for the treatment fraction were recorded and imported into a commercial treatment planning system. Changes in the dose volume histograms (DVH), as well as the PG volume histograms (PG-VH) for the PG emission from oxygen and for the total PG emission (from all elements) were analyzed. Results: For the 1 cm superior shift, the prostate DVH and total PG-VH both shifted toward lower doses with the shape of the curves remaining nearly unchanged, resulting in the DVH V95 dropping from 100 cGy to 90 cGy. For the total PG-VH, the V95 fell from 50 to 38. For the reduced oxygen case, both the DVH and PG-VH had a much different shape than for the ideal case, with a significant downward slope in the curves as a function of dose. Conclusions: The shift in the prostate PG-VH for a superior shift in the patient setup correlated well with the DVH indicating it is possible to detect setup errors by analyzing the PG-VH from prompt gamma images obtained during daily proton treatment delivery. Additionally, it may be possible to detect changes in the elemental concentrations of irradiated tissues by analyzing the shape of the PG-VH.

60 APPLIED LIFE SCIENCES↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

Element Verification and Comparison in Sierra/Solid Mechanics Problems

The goal of this project was to study the effects of element selection on the Sierra/SM solutions to five common solid mechanics problems. A total of nine element formulations were used for each problem. The models were run multiple times with varying spatial and temporal discretization in order to ensure convergence. The first four problems have been compared to analytical solutions, and all numerical results were found to be sufficiently accurate. The penetration problem was found to have a high mesh dependence in terms of element type, mesh discretization, and meshing scheme. Also, the time to solution is shown for each problem in order to facilitate element selection when computer resources are limited.

97 MATHEMATICS AND COMPUTING↗

Computational Characterization and Model Verification for 3D Microstructure Reconstruction of Additively-Manufactured Materials

The goal of this study is to characterize and validate the texture and grain topology of additively-manufactured anisotropic three-dimensional (3D) polycrystalline microstructures. The special focus is on developing methodologies to compare the grain shapes and orientations of two-dimensional (2D) and 3D microstructure representations using the same metric. To generate statistical data, synthetic microstructures are reconstructed from experimental data using Markov random field (MRF). The statistical similarity between the experimental and synthetic microstructures is verified by comparing their grain topologies. A universal measure to compare 2D and 3D grains is portrayed through the concept of image moments that are invariant to shape transformations. The graphical plots developed based on moment invariants to compare the 2D and 3D grains are used to verify the synthetic model

Materials Characterization↗

Verification of a Depletion Method in SCALE for the Advanced High Temperature Reactor

This study describes a new approach employing the Dancoff correction method to model the TRISO-based fuel form used by the Advanced High-Temperature Reactor (AHTR) reactor design concept. The Dancoff correction method is used to perform isotope depletion analysis using the TRITON sequence of SCALE and is verified by code-to-code comparisons. The current AHTR fuel design has TRISO particles concentrated along the edges of a slab fuel element. This geometry prevented the use of the DOUBLEHET treatment, previously developed in SCALE to model spherical and cylindrical fuel. The new method permits fuel depletion on complicated geometries that traditionally can be handled only by continuous energy based depletion code systems. The method was initially tested on a fuel configuration typical of the Next Generation Nuclear Plant (NGNP), where DOUBLEHET treatment is possible. A confirmatory study was performed on the AHTR reference core geometry using the VESTA code, which uses the continuous energy MCNP5 code as a transport solver and ORIGEN2.2 code for depletion calculations. Comparisons of the results indicate good agreement of whole core characteristics, such as the multiplication factor and the isotopics, including their spatial distribution. Key isotopes analyzed included 235U, 239Pu, 240Pu, and 241Pu. The results from this study indicate that the Dancoff factor method can generate estimates of core characteristics with reasonable precision for scoping studies of configurations where DOUBLEHET treatment cannot be performed.

AHTR↗

A Multitier System for the Verification, Visualization and Management of CHIMERA

CHIMERA is a multi-dimensional radiation hydrodynamics code designed to study core-collapse supernovae. The code is made up of three essentially independent parts: a hydrodynamics module, a nuclear burning module, and a neutrino transport solver combined within an operator-split approach. Given CHIMERA s complexity and pace of ongoing development, a new support system, Bellerophon, has been designed and implemented to perform automated verification, visualization and management tasks while integrating with other workflow systems utilized by CHIMERA s development group. In order to achieve these goals, a multitier approach has been adopted. By integrating supercomputing platforms, visualization clusters, a dedicated web server and a client-side desktop application, this system attempts to provide an encapsulated, end-to-end solution to these needs.

code verification↗

From Verified Models to Verifiable Code

Declarative specifications of digital systems often contain parts that can be automatically translated into executable code. Automated code generation may reduce or eliminate the kinds of errors typically introduced through manual code writing. For this approach to be effective, the generated code should be reasonably efficient and, more importantly, verifiable. This paper presents a prototype code generator for the Prototype Verification System (PVS) that translates a subset of PVS functional specifications into an intermediate language and subsequently to multiple target programming languages. Several case studies are presented to illustrate the tool's functionality. The generated code can be analyzed by software verification tools such as verification condition generators, static analyzers, and software model-checkers to increase the confidence that the generated code is correct.

Lensink, Leonard↗

Investigating rapid alpha-decay induced aging of 238 PuO 2 by Raman Spectroscopy

Investigating alpha-decay induced aging in PuO 2 is useful in nuclear forensics; helping to determine the time since last calcination. This was previously investigate by monitoring the damage to 240 PuO 2 over the course of a few years. The rate of alpha-decay induced aging has long been assumed to scale only with the decay rate of other isotopes without direct verification. This article reports the first alpha-decay aging study of 238 PuO 2 by Raman spectroscopy. Contrary to the expected 10 days for 238 PuO 2 to reach steady state based on 240 PuO 2 studies, the alpha aging curve reached an approximate steady state ∼24–30 h after laser annealing. While the cause of the order of magnitude decrease is unknown, it is speculated that dynamic annealing could contribute to the differences in rate of induced aging. The Raman spectra of annealed and aged 238 PuO 2 matched the expected features in 239 PuO 2 and 240 PuO 2 spectra; showing no formation of new stable chemical species in the material such as secondary Pu oxide phases (e.g., Pu 4 O 9 ). In conclusion, results indicate that 238 Pu could be leveraged for rapid alpha-decay aging studies to characterize alpha-decay induced features and better understand matrix temperatures and the annealing of Frankel pair defects.

Actinide↗

Respiratory Motional Effect on Cone-Beam CT in Lung Radiation Surgery

The cone-beam CT (CBCT), which is acquired using an on-board imager (OBI) attached to a linear accelerator, is used effectively in the verification of setup accuracy for lung radiation surgery. In this study, the respiratory organ motional effect on the CBCT was evaluated with a properly devised phantom system, and the level of possible error in conditions of a real clinical process was assessed. In a comparison study between the CBCT in static status and CBCT images acquired in 20 different motional cases, we confirmed that the image quality and information of CBCT were degraded, with an increase of motional ranges in the region of inhomogeneous structures. The 4D-CT MIP (50{approx}55%) for the planning of lung radiation surgery and the 4D-CT MIP (full phase) were compared with CBCT in the various motional cases for the evaluation of the influence of the motional effect on CBCT in the process of the setup error correction. The average ratio of relative difference between plan CT: 4D-CT MIP (50%{approx}55%) and CBCT was 5.79% and between plan CT: 4D-CT MIP (50%{approx}55%) and 4D-CT MIP (full phase) was 42.95% in the phantom study. In the analysis of clinical cases of lung radiation surgery, the gross tumor volumes were compared in each CT image. The average ratio of relative difference between plan CT: 4D-CT MIP (50{approx}55%) and CBCT was 10.72% and between plan CT: 4D-CT MIP (50{approx}55%) and 4D-CT MIP (full phase) was 28.19%. These results showed that, although a respiratory organ motional effect on CBCT introduced variation in image quality, the error as a result of this variation could be estimated relatively low in the setup error correction for a gated-lung radiation surgery when the planning was performed in 4D-CT MIP (50{approx}55%), which already included a related signal of motional effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhanced Sensitivity for Selected Reaction Monitoring–Mass Spectrometry-based Targeted Proteomics using a Dual-Stage Electrodynamic Ion Funnel Interface

Selected reaction monitoring-mass spectrometry (SRM-MS) is playing an increasing role in quantitative proteomics and biomarker discovery studies as a method for high throughput candidate quantification and verification. While SRM-MS offers advantages in sensitivity and quantification compared to other MS-based techniques, current SRM technologies are still challenged by detection and quantification of low-abundance proteins (e.g., present at ~10 ng/mL or lower levels in blood plasma). Here we report enhanced detection sensitivity and reproducibility for SRM-based targeted proteomics by coupling a dual electrodynamic ion funnel interface to a commercial triple quadrupole mass spectrometer. Due to the increased efficiency in ion transmission, significant enhancements in overall signal intensities and improved limits of detection were observed with the new interface compared to the original (capillary/skimmer) interface for SRM measurements of tryptic peptides from proteins spiked into non-depleted mouse plasma over a range of concentrations. Overall, average SRM peak intensities were increased by ~70-fold. The average level of detection for peptides also improved by ~14-fold, with notably improved reproducibility of peptide measurements as indicated by the reduced coefficients of variance. The ability to detect proteins ranging from 40 to 80 ng/mL within mouse plasma was demonstrated for all spiked proteins without the application of front-end immunoaffinity depletion and fractionation. This significant improvement in detection sensitivity for low-abundance proteins in complex matrices is expected to enhance a broad range of SRM-MS applications in addition to targeted protein and metabolite validation.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid approach for structural design of the tower and monopile for a series of 25 MW offshore turbines

The goal of further reducing the Levelized Cost of Energy (LCOE) has driven the investigation of large-scale wind turbines. This work presents a simple, rapid and detailed approach for the structural design of the tower and monopile without a controller, but with frequency and high fidelity structural verification. The approach uses an optimization to reduce the mass of the structures while meeting strength, buckling and geometric constraints by using analytical equations. A verification of frequency constraints is performed with BModes, and ANSYS Mechanical APDL is used for high fidelity verification of stress and buckling. The approach is applied to study the design space of three 25 MW offshore wind turbines with different rotor diameters and cone angles, and to evaluate the nacelle center of mass fore-aft location effect. Results obtained show that the tower and monopile are more susceptible to changes in the rotor thrust than the overturning moment even for designs with high pre-cone angle and large distance of the nacelle center of mass from the tower axis. But it is possible to obtain structurally feasible tower and monopile designs for the three 25 MW turbines studied while not exceeding diameter and wall thickness limits. However, mass penalties can be decreased by 0.8-14%, to further reduce the cost of energy, by increasing the diameter limit which may require manufacturing technology development. The approach applied and studies serve to understand the design space of the tower and monopile for a 25 MW turbine, and provide baseline designs that can be used in the development of a controller and evaluation of a full suite of design load cases.

17 WIND ENERGY↗

Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy

Purpose: Entrance dose (or skin dose) is an important part of patient quality assurance in external beam radiation therapy. However, entrance dose verification in proton beam is not routinely performed. In this study, the OneDose single use MOSFET detector system for in vivo dosimetry measurement in proton therapy is investigated. Methods: Using a solid water phantom, several fundamental dosimetric characteristics of the OneDose system are studied with a proton beam: The reproducibility (consistency) of the dosimeter, the linearity with dose and dose rate, energy dependence, directional dependence, LET dependence, and fading (delay readout with time) is studied. Results: OneDose detectors show dose and dose rate linearity but exhibit pronounced energy dependence at depth and a large variation in dose response with LET. On the other hand, the detector response remain relatively constant (within 3%) at surface over a wide range of energies. There is also a slight angular dependence (about 2%) up to 60 deg. angle of incidence. However, detector orientation such that incidence along the long axis of the detector should be avoided as the proton beam will have to traverse a large amount of the copper backing. Since most in vivo dosimetry involves entrance dose measurement, the OneDose at surface appears to be well suited for such application. OneDose exhibits small intrabatch variation ({<=}2% at one SD) indicating that it is only necessary to calibration a few detectors from each batch. The interbatch variation is generally within 3%. Conclusions: The small detector size and its relatively flexible design of OneDose allow dose measurement to be performed on a curved surface or in small cavities that is otherwise difficult with the conventional diode detectors. The slight drawback in its angular dependence can be easily handled by angular dependence table. However, since OneDose is a single use detector, the intrabatch consistency must be verified before the remaining detectors from the same batch could be used for in vivo dosimetry. It is advisable that the detectors from the same batch be taken for the same application to reduce the dosimetric uncertainty. For detectors from different batches, interbatch consistency should also be verified to obtain reliable results. OneDose provides an opportunity to measure in vivo dose with proton beam within acceptable clinical criterion of {+-}(5.0%-6.5%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source Characterization of Underground Explosions from Combined Regional Moment Tensor and First-Motion Analysis

Here in this study, we investigate the 14 September 1988 U.S.–Soviet Joint Verification Experiment nuclear test at the Semipalatinsk test site in eastern Kazakhstan and two nuclear explosions conducted less than 10 years later at the Chinese Lop Nor test site. These events were very sparsely recorded by stations located within 1600 km, and in each case only three or four stations were available in the regional distance range. We have utilized a regional distance seismic waveform method fitting long-period, complete, three-component waveforms jointly with first-motion observations from regional stations and teleseismic arrays. The combination of long-period waveforms and first-motion observations provides a unique discrimination of these sparsely recorded events in the context of the Hudson et al. (1989) source-type diagram. We demonstrate through a series of jackknife tests and sensitivity analyses that the source type of the explosions is well constrained. One event, a 1996 Lop Nor shaft explosion, displays large Love waves and possibly reversed Rayleigh waves at one station, indicative of a large F-factor. We show the combination of long-period waveforms and P-wave first motions are able to discriminate this event as explosion-like and distinct from earthquakes and collapses. We further demonstrate the behavior of network sensitivity solutions for models of tectonic release and spall-based tensile damage over a range of F-factors and K-factors.

58 GEOSCIENCES↗

Center for Multiscale Plasma Dynamics: Report on Activities (UCLA/MIT), 2009-2010

The final “phaseout” year of the CMPD ended July 2010; a no cost extension was requested until May 2011 in order to enable the MIT subcontract funds to be fully utilized. Research progress over this time included verification and validation activities for the BOUT and BOUT++ code, studies of spontaneous reconnection in the VTF facility at MIT, and studies of the interaction between Alfv´en waves and drift waves in LAPD. The CMPD also hosted the 6th plasma physics winter school in 2010 (jointly with the NSF frontier center the Center for Magnetic Self-Organization, significant funding came from NSF for this most recent iteration of theWinter School).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studying the Random Number Generators in MCNP6 using an Analytic Benchmark

An analytic solution to a previously studied toy problem is derived and used as a code verification benchmark. Using various Random Number Generators (RNGs) in MCNP6, including the newest SFC64 RNG available in MCNP6.3.1, and their various properties (e.g., RNG stride), we show how these RNGs perform and how to correct or workaround potential issues with respect to the analytic benchmark problem.

97 MATHEMATICS AND COMPUTING↗