Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Preferential Paths of Air-water Two-phase Flow in Porous Structures with Special Consideration of Channel Thickness Effects

Accurate understanding and predicting the flow paths of immiscible two-phase flow in rocky porous structures are of critical importance for the evaluation of oil or gas recovery and prediction of rock slides caused by gas-liquid flow. A 2D phase field model was established for compressible air-water two-phase flow in heterogenous porous structures. The dynamic characteristics of air-water two-phase interface and preferential paths in porous structures were simulated. The factors affecting the path selection of two-phase flow in porous structures were analyzed. Transparent physical models of complex porous structures were prepared using 3D printing technology. Tracer dye was used to visually observe the flow characteristics and path selection in air-water two-phase displacement experiments. The experimental observations agree with the numerical results used to validate the accuracy of phase field model. The effects of channel thickness on the air-water two-phase flow behavior and paths in porous structures were also analyzed. The results indicate that thick channels can induce secondary air flow paths due to the increase in flow resistance; consequently, the flow distribution is different from that in narrow channels. This study provides a new reference for quantitatively analyzing multi-phase flow and predicting the preferential paths of immiscible fluids in porous structures.

42 ENGINEERING↗

Spatially co-registered wide-field nonlinear optical imaging of living and complex biosystems in a total internal reflection geometry

Nonlinear optical microscopy that leverages an objective based total internal reflection (TIR) excitation scheme is an attractive means for rapid, wide-field imaging with enhanced surface sensitivity. Through select combinations of distinct modalities, one can, in principle, access complementary chemical and structural information for various chemical species near interfaces. Here, we report a successful implementation of such a wide-field nonlinear optical microscope system, which combines coherent anti-Stokes Raman scattering (CARS), two-photon fluorescence (TPF), second harmonic generation (SHG), and sum frequency generation (SFG) modalities on the same platform. The intense optical fields needed to drive these high order nonlinear optical processes are achieved through the use of femtosecond pulsed light in combination with the intrinsic field confinement induced by TIR over a large field of view. The performance of our multimodal microscope was first assessed through the experimental determination of its chemical fidelity, intensity and polarization dependences, and spatial resolution using a set of well-defined model systems. Subsequently, its unique capabilities were validated through imaging complex biological systems, including Hydrangea quercifolia pollen grains and Pantoea sp. YR343 bacterial cells. Specifically, the spatial distribution of different molecular groups in the former was visualized via vibrational contrast mechanisms of CARS, whereas co-registered TPF imaging allowed the identification of spatially localized intrinsic fluorophores. We further demonstrate the feasibility of our microscope for wide-field CARS imaging on live cells through independent characterization of cell viability using spatially co-registered TPF imaging. Overall, this approach to TIR enabled wide-field imaging is expected to provide new insights into bacterial strains and their interactions with other species in the rhizosphere in a time-resolved and chemically selective manner.

47 OTHER INSTRUMENTATION↗

Durability of Polymeric Encapsulation Materials for Concentrating Photovoltaic Systems (Presentation)

Many concentrating photovoltaic (CPV) systems use a polymeric encapsulant to couple and optical component and/or coverglass to the cell. In that location, the encapsulation improves the transmission of concentrated optical flux through interface(s), while protecting the cell from the environment. The durability of encapsulation materials, however, is not well established relative to the desiredservice life of 30 years. Therefore, we have initiated a screen test to identify the field-induced failure modes for a variety of popular PV encapsulation materials. An existing CPV module (with no PV cells present) was modified to accommodate encapsulation specimens. The module (where nominal concentration of solar flux is 500x for the domed-Fresnel design) has been mounted on a tracker inGolden, CO (elevation 1.79 km). Initial results are reported here for 18 months cumulative exposure, including the hottest and coldest months of the past year. Characteristics observed at intervals during that time include: visual appearance, direct and hemispherical transmittance, and mass. Degradation may be assessed from subsequent analysis (including yellowness index and cut-on frequency)relative to the ambient conditions present during field exposure. The fluorescence signature observed of all the silicone specimens is examined here, including possible factors of causation -- the platinum catalyst used in the addition cured materials as well as the primer used to promote adhesion to the quartz substrate and superstrate.

14 SOLAR ENERGY↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Local Ionic Dynamics in Functional Oxides at the Nanoscale

A scanning probe microscopy (SPM) based technique for probing local ionic dynamics in electrochemically-active materials based on the first-order reversal curve current-voltage (FORC-IV) method is presented. FORC-IV imaging mode is applied to a Ca-substituted bismuth ferrite (Ca-BFO) system to separate the electronic and ionic phenomena in this material and visualize the spatial variability of these behaviors. The variable-temperature measurements further demonstrate the interplay between the thermally and electric-field-driven resistance changes in Ca-BFO. The FORC-IV is shown to be a simple, powerful and flexible method for studying electrochemical activity of materials at the nanoscale and, in conjunction with the Electrochemical Strain Microscopy, for differentiating ferroelectric and ionic behaviors.

Ca-BFO↗

A biomimetic eye with a hemispherical perovskite nanowire array retina

Human eyes possess exceptional image-sensing characteristics such as an extremely wide field of view, high resolution and sensitivity with low aberration1. Biomimetic eyes with such characteristics are highly desirable, especially in robotics and visual prostheses. However, the spherical shape and the retina of the biological eye pose an enormous fabrication challenge for biomimetic devices2,3. In this paper, we present an electrochemical eye with a hemispherical retina made of a high-density array of nanowires mimicking the photoreceptors on a human retina. The device design has a high degree of structural similarity to a human eye with the potential to achieve high imaging resolution when individual nanowires are electrically addressed. Additionally, we demonstrate the image-sensing function of our biomimetic device by reconstructing the optical patterns projected onto the device. This work may lead to biomimetic photosensing devices that could find use in a wide spectrum of technological applications.

42 ENGINEERING↗

Dark-field X-ray imaging of unsaturated water transport in porous materials

We introduce in this Letter an approach to X-ray imaging of unsaturated water transport in porous materials based upon the intrinsic X-ray scattering produced by the material microstructural heterogeneity at a length scale below the imaging system spatial resolution. The basic principle for image contrast creation consists in a reduction of such scattering by permeation of the porosity by water. The implementation of the approach is based upon X-ray dark-field imaging via Talbot-Lau interferometry. The proof-of-concept is provided by performing laboratory-scale dark-field X-ray radiography of mortar samples during a water capillary uptake experiment. The results suggest that the proposed approach to visualizing unsaturated water transport in porous materials is complementary to neutron and magnetic resonance imaging and alternative to standard X-ray imaging, the latter requiring the use of contrast agents because based upon X-ray attenuation only.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Durability of Polymeric Encapsulation Materials for Concentrating Photovoltaic Systems (Presentation)

Many concentrating photovoltaic (CPV) systems use a polymeric encapsulant to couple and optical component and/or coverglass to the cell. In that location, the encapsulation improves the transmission of concentrated optical flux through interface(s), while protecting the cell from the environment. The durability of encapsulation materials, however, is not well established relative to the desired service life of 30 years. Therefore, we have initiated a screen test to identify the field-induced failure modes for a variety of popular PV encapsulation materials. An existing CPV module (with no PV cells present) was modified to accommodate encapsulation specimens. The module (where nominal concentration of solar flux is 500x for the domed-Fresnel design) has been mounted on a tracker in Golden, CO (elevation 1.79 km). Initial results are reported here for 18 months cumulative exposure, including the hottest and coldest months of the past year. Characteristics observed at intervals during that time include: visual appearance, direct and hemispherical transmittance, and mass. Degradation may be assessed from subsequent analysis (including yellowness index and cut-on frequency) relative to the ambient conditions present during field exposure. The fluorescence signature observed of all the silicone specimens is examined here, including possible factors of causation -- the platinum catalyst used in the addition cured materials as well as the primer used to promote adhesion to the quartz substrate and superstrate.

14 SOLAR ENERGY↗

Growth of graphene underlayers by chemical vapor deposition

We present a simple and very convincing approach to visualizing that subsequent layers of graphene grow between the existing monolayer graphene and the copper catalyst in chemical vapor deposition (CVD). Graphene samples were grown by CVD and then transferred onto glass substrates by the bubbling method in two ways, either direct-transfer (DT) to yield poly (methyl methacrylate) (PMMA)/graphene/glass or (2) inverted transfer (IT) to yield graphene/PMMA/glass. Field emission scanning electron microscopy (FE-SEM) and atomic force microscopy (AFM) were used to reveal surface features for both the DT and IT samples. The results from FE-SEM and AFM topographic analyses of the surfaces revealed the underlayer growth of subsequent layers. The subsequent layers in the IT samples are visualized as 3D structures, where the smaller graphene layers lie above the larger layers stacked in a concentric manner. The results support the formation of the so-called “inverted wedding cake” stacking in multilayer graphene growth.

36 MATERIALS SCIENCE↗

A note on the visualization of wetting film structures and a nonwetting immiscible fluid in a pore network micromodel using a solvatochromic dye

Nile Red is demonstrated as a single dye whose solvatochromism enables selective visualization of two immiscible liquid fluids in a micromodel containing a homogeneous array of pillars creating a porous network. Nile Red dissolves in and partitions between hexadecane as a nonwetting fluid and PEG200 as a hydrophilic fluid that wets the silicon oxide surfaces in the micromodel. Both the absorption spectra and fluorescence emission spectra are sensitive to the solvent environment, such that the two phases can be distinguished by the observed color or the fluorescence emission band. Bright field, hyperspectral, epifluorescence, and confocal fluorescence methods were used to image the micromodel after displacing PEG200 in the model with hexadecane. The use of Nile Red with these imaging methods facilitates visualization of phase identity at specific locations; the interfaces between the two immiscible liquid phases; wetting behavior of the wetting phase within the porous structure; and retention of the wetting phase as thin films around pillars and as bridges across the pore throats. The pillars and wetting phase bridges create a network of obstacles defining a tortuous preferential flow path for the nonwetting phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of neuronal cell classes and types in the vertebrate retina

The basic plan of the retina is conserved across vertebrates, yet species differ profoundly in their visual needs1. Retinal cell types may have evolved to accommodate these varied needs, but this has not been systematically studied. Here we generated and integrated single-cell transcriptomic atlases of the retina from 17 species: humans, two non-human primates, four rodents, three ungulates, opossum, ferret, tree shrew, a bird, a reptile, a teleost fish and a lamprey. We found high molecular conservation of the six retinal cell classes (photoreceptors, horizontal cells, bipolar cells, amacrine cells, retinal ganglion cells (RGCs) and Müller glia), with transcriptomic variation across species related to evolutionary distance. Major subclasses were also conserved, whereas variation among cell types within classes or subclasses was more pronounced. However, an integrative analysis revealed that numerous cell types are shared across species, based on conserved gene expression programmes that are likely to trace back to an early ancestral vertebrate. The degree of variation among cell types increased from the outer retina (photoreceptors) to the inner retina (RGCs), suggesting that evolution acts preferentially to shape the retinal output. Finally, we identified rodent orthologues of midget RGCs, which comprise more than 80% of RGCs in the human retina, subserve high-acuity vision, and were previously believed to be restricted to primates. By contrast, the mouse orthologues have large receptive fields and comprise around 2% of mouse RGCs. Projections of both primate and mouse orthologous types are overrepresented in the thalamus, which supplies the primary visual cortex. We suggest that midget RGCs are not primate innovations, but are descendants of evolutionarily ancient types that decreased in size and increased in number as primates evolved, thereby facilitating high visual acuity and increased cortical processing of visual information.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Reccurent Patterns in Toroidal Magnetic Fields

In the development of magnetic confinement fusion which will be a future source for low cost power, physicists must be able to analyze the magnetic field that confines the burning plasma. While the magnetic field can be described as a series of vectors, traditional techniques for analyzing the field s topology can not be used because of its homoclinic nature. In this paper we describe a technique developed as a collaboration between physicists and computer scientists that determines the topology of a toroidal magnetic field using fieldlines with near minimal lengths. More specifically, we analyze the Poincare map of the sampled fieldlines in a Poincare section including identifying critical points and other topological features of interest to physicists. The technique has been deployed into an interactive parallel visualization tool which physicists are using to gain new insight into simulations of magnetically confined buring plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PROPERTIES OF INTERSTELLAR TURBULENCE FROM GRADIENTS OF LINEAR POLARIZATION MAPS

Faraday rotation of linearly polarized radio signals provides a very sensitive probe of fluctuations in the interstellar magnetic field and ionized gas density resulting from magnetohydrodynamic (MHD) turbulence. We used a set of statistical tools to analyze images of the spatial gradient of linearly polarized radio emission (|{nabla}P|) for both observational data from a test image of the Southern Galactic Plane Survey (SGPS) and isothermal three-dimensional simulations of MHD turbulence. Visually, in both observations and simulations, a complex network of filamentary structures is seen. Our analysis shows that the filaments in |{nabla}P| can be produced both by interacting shocks and random fluctuations characterizing the non-differentiable field of MHD turbulence. The latter dominates for subsonic turbulence, while the former is only present in supersonic turbulence. We show that supersonic and subsonic turbulence exhibit different distributions as well as different morphologies in the maps of |{nabla}P|. Particularly, filaments produced by shocks show a characteristic 'double jump' profile at the sites of shock fronts resulting from delta function-like increases in the density and/or magnetic field, while those produced by subsonic turbulence show a single jump profile. In order to quantitatively characterize these differences, we use the topology tool known as the genus curve as well as the probability distribution function moments of the image distribution. We find that higher values for the moments correspond to cases of |{nabla}P| with larger sonic Mach numbers. The genus analysis of the supersonic simulations of |{nabla}P| reveals a 'swiss cheese' topology, while the subsonic cases have characteristics of a 'clump' topology. Based on the analysis of the genus and the higher order moments, the SGPS test region data have a distribution and morphology that match subsonic- to transonic-type turbulence, which confirms what is now expected for the warm ionized medium.

79 ASTRONOMY AND ASTROPHYSICS↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing Load Cell Monitoring on the Mock UF 6 Feed and Withdrawal System

A proof-of-concept load cell monitoring system has been developed for the Mock Feed and Withdrawal (F&W) System at Oak Ridge National Laboratory (ORNL). This system leverages industry-standard commercial off-the-shelf (COTS) hardware and software in a modular and scalable design. The Mock F&W System was designed to simulate operations at a uranium hexafluoride (UF 6 ) gas centrifuge enrichment plant F&W area. It provides a test bed for process-monitoring technologies. Water, used as a surrogate for UF 6 , is pumped from three feed tanks, through a process surge tank, and is then cut between two tails tanks and three product tanks. The weight of the each tank is continuously monitored using a load cell monitoring system. In addition to the F&W stations, large and small accountancy stations are monitored. The Mock F&W System allows ORNL to test and evaluate capabilities of industry-standard process monitoring hardware and software. A variety of commonly used weighing indicators are connected to the load cells to monitor the weight at each station. These weighing indicators are representative of the types likely found in operating facilities. A data center modeled after those currently used for international safeguards was installed to collect and manage the weight data. This data center provides a robust and flexible test bed for testing and developing software solutions. COTS software packages that leverage industry-standard communication protocols provide a data flow architecture that is modular, interoperable, and scalable. One software package provides communication drivers to collect the raw weight data from the weighing indicators. A data historian is used to store the raw data. Custom in-house algorithms have been developed using MATLAB to analyze the raw historical data and to automatically identify process information. This information includes the number of cycles completed and the mass of material transferred from stations to the process. The process information identified by the analysis is stored in a Microsoft SQL Server database. Visualization concepts have been developed that display the analyzed process information alongside visually compelling plots and animations of the raw data. The load cell monitoring system developed on the Mock F&W System was designed as a proof of concept that could be scaled to a field trial at an operating facility. This system, built with industry standard hardware and software, has allowed ORNL to develop capabilities that provide confidence in the ability to leverage existing operator load cell monitoring equipment with minimal impact on operations. The international safeguards community is evaluating the use of load cell monitoring as an additional safeguards measure; this system demonstrates a practical solution to collect, store, analyze, and visualize load cell weight data.

commercial off the shelf↗