Technological progress in the development, testing, and manufacturing of nickel-cadmium battery cells as well as hydrogen cells is presented. The following major topics were discussed: (1) carbonate analysis; (2) nickel-cadmium memory effect; (3) use of batteries in an automatic acquisition and control system; (4) accelerated testing; (5) formulation of a mathematical odel for a nickel-cadmium cell; (6) development of a light weight nickel-cadmium battery capable of delivering 20 watt hours per pound; (7) magnetic testing of nickel-cadmium cells; (8) design and performance characteristics of nickel-hydrogen and silver-hydrogen cells; and (9) development of a semiprismatic cell design. For Vol. 1, see N75-15152.

Source record↗

MARS15-Based System for Beam Loss and Collimation Studies

The system includes the newest version of the MARS15 code for particle production and transport in accelerator components integrated with a novel highprecision tracker/stepper for multi-turn tracking merged with MAD-X. The overall approach is described with all the essential features and programming issues highlighted. The application is illustrated for the Fermilab Recycler Ring and Integrable Optics Test Accelerator (IOTA) facilities as well as for the Higgs Factory muon collider and International $e^+e^−$ Linear Collider (ILC) projects.

43 PARTICLE ACCELERATORS↗

Rebuild of Capture Cavity 1 at Fermilab

The front end of the proposed Advanced Superconducting Test Accelerator at Fermilab employs two single cavity cryomodules, known as 'Capture Cavity 1' and 'Capture Cavity 2', for the first stage of acceleration. Capture Cavity 1 was previously used as the accelerating structure for the A0 Photoinjector to a peak energy of ~14 MeV. In its new location a gradient of ~25 MV/m is required. This has necessitated a major rebuild of the cryomodule including replacement of the cavity with a higher gradient one. Retrofitting the cavity and making upgrades to the module required significant redesign. The design choices and their rationale, summary of the rebuild, and early test results are presented.

43 PARTICLE ACCELERATORS↗

SU-C-BRE-06: Radiobiological Advantage of Very Rapid Irradiation

Purpose: To characterize the effect of very rapid dose delivery as compared to conventional therapeutic irradiation times on clonogenic cell survival. Methods: We used a Varian Trilogy linear accelerator to deliver doses up to 10 Gy using a 6 MV SRS photon beam. We irradiated four cancer cell lines in times ranging from 30 sec to 30 min. We also used a Varian TrueBeam linear accelerator to deliver 9 MeV electrons at 10 Gy in 10 s to 30 min to determine the effect of irradiation time on cell survival. We then evaluated the effect of using 60 and 120 MeV electrons on cell survival using the Next Linear Collider Test Accelerator (NLCTA) beam line at the SLAC National Accelerator Laboratory. During irradiation, adherent cells were maintained at 37oC with 20%O2/5%CO2. Clonogenic assays were completed following irradiation to determine changes in cell survival due to dose delivery time and beam quality, and the survival data were fitted with the linear-quadratic model. Results: Cell lines varied in radiosensitivity, ranging from two to four logs of cell kill at 10 Gy for both conventional and very rapid irradiation. Delivering radiation in shorter times decreased survival in all cell lines. Log differences in cell kill ranged from 0.2 to 0.7 at 10 Gy for the short compared to the long irradiation time. Cell kill differences between short and long irradiations were more pronounced as doses increased for all cell lines. Conclusion: Our findings suggest that shortening delivery of therapeutic radiation doses to less than 1 minute may improve tumor cell kill. This study demonstrates the potential advantage of technologies under development to deliver stereotactic ablative radiation doses very rapidly. Bill Loo and Peter Maxim have received Honoraria from Varian and Research Support from Varian and RaySearch.

60 APPLIED LIFE SCIENCES↗

Validating pyORBIT for Modeling Beam Dynamics in the IOTA Ring

The Integrable Optics Test Accelerator (IOTA) ring is a new Fermilab facility dedicated to beam physics experiments, currently operating with 150 MeV electrons. Space charge effects are expected to be significant when it operates with 2.5 MeV protons. In this contribution, we present results of a suite of validation tests of PyORBIT, a PICstyle space charge code. Single particle dynamics of quasiintegrable optics using an octupole string in IOTA is compared with MADX, and shown to be in good agreement. Requirements for the convergence of space charge computations are systematically established and when possible, tests involving space charge are compared with theoretical predictions.

Li, Runze↗

The importance of batteries in unmanned missions

A brief overview of the current set of unmanned missions that are currently in operation and those planned for the next 5 to 10 years was presented. The important role of batteries in the development of successful missions was discussed. The workhorse battery, the NiCd, and its use throughout historical missions was explored. Its role on Observers and Landers was discussed, and the success those batteries had. The recent events in the issues of quality and life for NiCd batteries were discussed. These discussions focused on the current design activities for Mars Observer (MO), TOPEX, and Mariner Mark II. Separator selection and the need for uniform testing procedures to develop a quality battery product that can perform to mission requirements were discussed. The recent experiences with the GRO battery failure and the other events have led JPL to the decision to develop a testing program in conjunction with other NASA centers to determine the best separator material for these two missions. The decision for separator material and battery design must be made a year from now. Thus there will not be time to perform a total 2-year accelerated test. The JPL plan for coping with this compromise was discussed. A discussion of where NiH2 batteries are beginning to have an impact and the difficulties with their implementation were addressed. Such missions at Earth Observing System (EOS) and the NOAA series of satellites rely upon NiH2 for success but were not chosen for TOPEX or MO due to their large volume requirements.

Klein, John W.↗

Accelerated Stress-Corrosion Testing

Test procedures for accelerated stress-corrosion testing of high-strength aluminum alloys faster and provide more quantitative information than traditional pass/fail tests. Method uses data from tests on specimen sets exposed to corrosive environment at several levels of applied static tensile stress for selected exposure times then subsequently tensile tested to failure. Method potentially applicable to other degrading phenomena (such as fatigue, corrosion fatigue, fretting, wear, and creep) that promote development and growth of cracklike flaws within material.

Source record↗

Optical stochastic cooling at Fermilab’s IOTA ring

Stochastic cooling (SC) constitutes one of the greatest conceptual and technological achievements in particle beam cooling. Numerous SC systems have been built in the microwave regime and used to extend the science reach of accelerator facilities worldwide. The ability to sense and correct the particle ensemble using high-bandwidth feedback systems is at the core of the concept. Here, we describe the first realization of SC at optical frequencies and bandwidths. The demonstration was recently carried out at Fermilab’s integrable optics test accelerator (IOTA) storage ring using the transit-time method of optical stochastic cooling (OSC) and achieved an integrated system bandwidth of approximately 20 THz, which is more than 2000 times that of conventional SC systems. This demonstration establishes the foundation for more advanced OSC experiments with high-gain amplification, currently underway at Fermilab, and the eventual application of OSC to colliders and other accelerator facilities.

Jarvis, Jonathan D. [Fermilab]↗

IOTA Pre-Bake Test Development

The IOTA (Integrable Optics Test Accelerator) Bakeout project is intended to improve the quality of the vacuum within the IOTA ring. Impurities consisting of hydrogen and oxygen that build within the beampipe are reduced through applying heat to the beampipe’s exterior. Two versions of the Bakeout project exist, one as a smaller scale test setup, and one five times larger located within the IOTA ring. During my internship, I worked together with a team to bring this project from an effectively dormant state to ready for testing, working together to create full documentation of the PLC (Programmable Logic Controller) programs, making multiple new hardware configurations of this test possible, as well as an additional safety system.

Seagrave, Kayla [DuPage Coll.; Fermilab]↗

SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial interests with the commercialization of this QA device.

07 ISOTOPE AND RADIATION SOURCES↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

Electron Cloud at Low Emittance in CesrTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud’s effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.

43 PARTICLE ACCELERATORS↗

Handbook of photothermal test data on encapsulant materials

Laboratory tests performed to characterize candidate encapsulation materials with respect to changes in their physical and chemical properties caused by photothermal aging are described. Several key material properties relating directly to material degradation and deterioration of performance were identified and were monitored as functions of aging conditions and time. A status report on accelerated testing activities is provided and experimental data are presented. It will be updated periodically as more data become available.

Liang, R. H.↗

A Project to Design and Build the Magnets for a New Test Beamline, the ATF2, at KEK

In order to achieve the high luminosity required at the proposed International Linear Collider (ILC), it is critical to focus the beams to nanometer size with the ILC Beam Delivery System, and to maintain the beams collisions with a nanometer-scale stability. To establish the technologies associated with this ultra-high precision beam handling, a special beamline has been designed and built as an extension of the existing extraction beamline of the Accelerator Test Facility at KEK, Japan. The ATF provides an adequate ultra-low emittance electron beam that is comparable to the ILC requirements; the ATF2 mimics the ILC final focus system to create a tightly focused, stable beam. There are 37 magnets in the ATF2, 29 quadrupoles, 5 sextupoles and 3 bends. These magnets had to be acquired in a short time and at minimum cost, which led to various acquisition strategies; but nevertheless they had to meet strict requirements on integrated strength, physical dimensions, compatibility with existing magnet movers and beam position monitors, mechanical stability and field stability and quality. This paper will describe how 2 styles of quadrupoles, 2 styles of sextupoles, one dipole style and their supports were designed, fabricated, refurbished or modified, measured and aligned by a small team of engineers from 3 continents.

43 PARTICLE ACCELERATORS↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

BNL ATF II beamlines design

The Brookhaven National Laboratory. Accelerator Test Facility (BNL ATF) is currently undergoing a major upgrade (ATF-II). Together with a new location and much improved facilities, the ATF will see an upgrade in its major capabilities: electron beam energy and quality and CO 2 laser power. The electron beam energy will be increased in stages, first to 100-150 MeV followed by a further increase to 500 MeV. Combined with the planned increase in CO 2 laser power (from 1-100 TW), the ATF-II will be a powerful tool for Advanced Accelerator research. A high-brightness electron beam, produced by a photocathode gun, will be accelerated and optionally delivered to multiple beamlines. Besides the energy range (up to a possible 500 MeV in the final stage) the electron beam can be tailored to each experiment with options such as: small transverse beam size (<10 um), short bunch length (<100 fsec) and, combined short and small bunch options. This report gives a detailed overview of the ATFII capabilities and beamlines configuration.

43 PARTICLE ACCELERATORS↗

Generation of Ramped Current Profiles in Relativistic Electron Beams Using Wakefields in Dielectric Structures

We show that temporal pulse tailoring of charged-particle beams is essential to optimize efficiency in collinear wakefield acceleration schemes. In this Letter, we demonstrate a novel phase space manipulation method that employs a beam wakefield interaction in a dielectric structure, followed by bunch compression in a permanent magnet chicane, to longitudinally tailor the pulse shape of an electron beam. This compact, passive, approach was used to generate a nearly linearly ramped current profile in a relativistic electron beam experiment carried out at the Brookhaven National Laboratory Accelerator Test Facility. Here, we report on these experimental results including beam and wakefield diagnostics and pulse profile reconstruction techniques.

43 PARTICLE ACCELERATORS↗

Efficient Reversible Operation and Stability of Novel Solid Oxide Cells

This project aims to develop and test novel Reversible Solid Oxide Cells (ReSOCs) specifically designed to yield low area specific resistance, as required to achieve high round trip efficiency in reversible operation at high current density. A key objective is to improve long-term reversible SOC durability; mechanistic degradation models will be used to predict long-term durability using input data from accelerated testing that combines electrochemical life testing with quantitative microstructural and chemical evaluation. The modeling tasks seek to design low-loss, low-cost ReSOC systems using input data from the experimental cell studies. A key challenge is to develop a thermal management strategy that maintains thermally self-sustaining operation while operating the stack at a potential lower than the thermo-neutral steam electrolysis voltage of ~1.3 V, to maintain high efficiency.

08 HYDROGEN↗