Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Experimental characterization of energetic material dynamics for multiphase blast simulation.

Currently there is a substantial lack of data for interactions of shock waves with particle fields having volume fractions residing between the dilute and granular regimes, which creates one of the largest sources of uncertainty in the simulation of energetic material detonation. To close this gap, a novel Multiphase Shock Tube has been constructed to drive a planar shock wave into a dense gas-solid field of particles. A nearly spatially isotropic field of particles is generated in the test section by a gravity-fed method that results in a spanwise curtain of spherical 100-micron particles having a volume fraction of about 19%. Interactions with incident shock Mach numbers of 1.66, 1.92, and 2.02 were achieved. High-speed schlieren imaging simultaneous with high-frequency wall pressure measurements are used to reveal the complex wave structure associated with the interaction. Following incident shock impingement, transmitted and reflected shocks are observed, which lead to differences in particle drag across the streamwise dimension of the curtain. Shortly thereafter, the particle field begins to propagate downstream and spread. For all three Mach numbers tested, the energy and momentum fluxes in the induced flow far downstream are reduced about 30-40% by the presence of the particle field. X-Ray diagnostics have been developed to penetrate the opacity of the flow, revealing the concentrations throughout the particle field as it expands and spreads downstream with time. Furthermore, an X-Ray particle tracking velocimetry diagnostic has been demonstrated to be feasible for this flow, which can be used to follow the trajectory of tracer particles seeded into the curtain. Additional experiments on single spherical particles accelerated behind an incident shock wave have shown that elevated particle drag coefficients can be attributed to increased compressibility rather than flow unsteadiness, clarifying confusing results from the historical database of shock tube experiments. The development of the Multiphase Shock Tube and associated diagnostic capabilities offers experimental capability to a previously inaccessible regime, which can provide unprecedented data concerning particle dynamics of dense gas-solid flows.

36 MATERIALS SCIENCE↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Facilitating Machine Learning Collaborations Between Labs, Universities, And Industry

It is clear from numerous recent community reports, papers, and proposals that machine learning is of tremendous interest for particle accelerator applications. The quickly evolving landscape continues to grow in both the breadth and depth of applications including physics modeling, anomaly detection, controls, diagnostics, and analysis. Consequently, laboratories, universities, and companies across the globe have established dedicated machine learning (ML) and data science efforts aiming to make use of these new state-of-the-art tools. The current funding environment in the U.S. is structured in a way that supports specific application spaces rather than larger collaboration on community software. Here, we discuss the existing collaboration bottlenecks and how a shift in the funding environment, and how we develop collaborative tools, can help fuel the next wave of ML advancements for particle accelerators.

Edelen, J.P.↗

High Gradient Accelerator Research

The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave cold test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.

43 PARTICLE ACCELERATORS↗

Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10{sup 16}-10{sup 18} W/cm{sup 2} with CO{sub 2} clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t {approx} 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of {approx}100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction on X-ray output of free electron laser based on artificial neural networks

Abstract Knowledge of x-ray free electron lasers’ (XFELs) pulse characteristics delivered to a sample is crucial for ensuring high-quality x-rays for scientific experiments. XFELs’ self-amplified spontaneous emission process causes spatial and spectral variations in x-ray pulses entering a sample, which leads to measurement uncertainties for experiments relying on multiple XFEL pulses. Accurate in-situ measurements of x-ray wavefront and energy spectrum incident upon a sample poses challenges. Here we address this by developing a virtual diagnostics framework using an artificial neural network (ANN) to predict x-ray photon beam properties from electron beam properties. We recorded XFEL electron parameters while adjusting the accelerator’s configurations and measured the resulting x-ray wavefront and energy spectrum shot-to-shot. Training the ANN with this data enables effective prediction of single-shot or average x-ray beam output based on XFEL undulator and electron parameters. This demonstrates the potential of utilizing ANNs for virtual diagnostics linking XFEL electron and photon beam properties.

47 OTHER INSTRUMENTATION↗

Electron Self-Injection into an Evolving Plasma Bubble: The Way to a Dark Current Free GeV-Scale Laser Accelerator

A time-varying electron density bubble created by the radiation pressure of a tightly focused petawatt laser pulse traps electrons of ambient rarefied plasma and accelerates them to a GeV energy over a few-cm distance. Expansion of the bubble caused by the shape variation of the self-guided pulse is the primary cause of electron self-injection in strongly rarefied plasmas (n{sub e{approx}}10{sup 17} cm{sup -3}). Stabilization and contraction of the bubble extinguishes the injection. After the bubble stabilization, longitudinal non-uniformity of the accelerating gradient results in a rapid phase space rotation that produces a quasi-monoenergetic bunch well before the de-phasing limit. Combination of reduced and fully self-consistent (first-principle) 3-D PIC simulations complemented with the Hamiltonian diagnostics of electron phase space shows that the bubble dynamics and the self-injection process are governed primarily by the driver evolution; collective transverse fields of the trapped electron bunch reduce the accelerating gradient, slow down phase space rotation, and result in a formation of monoenergetic electron beam with higher energy than test-particle modeling predicts.

43 PARTICLE ACCELERATORS↗

Photoluminescence of radiation-induced color centers in lithium fluoride thin films for advanced diagnostics of proton beams

Systematic irradiation of thermally evaporated 0.8 μm thick polycrystalline lithium fluoride films on glass was performed by proton beams of 3 and 7 MeV energies, produced by a linear accelerator, in a fluence range from 10{sup 11} to 10{sup 15} protons/cm{sup 2}. The visible photoluminescence spectra of radiation-induced F{sub 2} and F{sub 3}{sup +} laser active color centers, which possess almost overlapping absorption bands at about 450 nm, were measured under laser pumping at 458 nm. On the basis of simulations of the linear energy transfer with proton penetration depth in LiF, it was possible to obtain the behavior of the measured integrated photoluminescence intensity of proton irradiated LiF films as a function of the deposited dose. The photoluminescence signal is linearly dependent on the deposited dose in the interval from 10{sup 3} to about 10{sup 6 }Gy, independently from the used proton energies. This behavior is very encouraging for the development of advanced solid state radiation detectors based on optically transparent LiF thin films for proton beam diagnostics and two-dimensional dose mapping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FLASH2: Operation, beamlines, and photon diagnostics

FLASH2, a major extension of the soft X-ray free-electron laser FLASH at DESY, turns FLASH into a multi-user FEL facility. A new undulator line is located in a separate accelerator tunnel and driven additionally by the FLASH linear accelerator. First lasing of FLASH2 was achieved in August 2014 with simultaneous user operation at FLASH1. The new FLASH2 experimental hall offers space for up to six experimental end stations, some of which will be installed permanently. The wide wavelength range spans from 4-60 nm and 0.8 nm in the 5{sup th} harmonic and in the future deep into the water window in the fundamental. While this is of high interest to users, it is challenging from the beamline instrumentation point of view. Online diagnostics - which are mostly pulse resolved - for beam intensity, position, wavelength, wave front, and pulse length have been to a large extent developed at FLASH(1) and have now been optimized for FLASH2. Pump-probe facilities for XUV-XUV, XUV optical and XUV-THz experiments will complete the FLASH2 user facility.

43 PARTICLE ACCELERATORS↗

A Potential Method for Diagnostics of Subfemtosecond Electron Beams Using Coherent Optical Transition Radiation

Coherent transition radiation (CTR) is widely used in determining the longitudinal e-beam dimensions in the accelerator technology applications. In this study, the CTR process is investigated in a real Au-target for the sake of measuring the size characteristics of the electron bunches with lengths from 100 to 300 nm, and possible applications of such targets is demonstrated.

43 PARTICLE ACCELERATORS↗

Laboratory studies in ultraviolet solar physics

The research activity comprised the measurement of basic atomic processes and parameters which relate directly to the interpretation of solar ultraviolet observations and to the development of comprehensive models of the component structures of the solar atmosphere. The research was specifically directed towards providing the relevant atomic data needed to perform and to improve solar diagnostic techniques which probe active and quiet portions of the solar chromosphere, the transition zone, the inner corona, and the solar wind acceleration regions of the extended corona. The accuracy with which the physical conditions in these structures can be determined depends directly on the accuracy and completeness of the atomic and molecular data. These laboratory data are used to support the analysis programs of past and current solar observations (e.g., the Orbiting solar Observatories, the Solar Maximum Mission, the Skylab Apollo Telescope Mount, and the Naval Research Laboratory's rocket-borne High Resolution Telescope and Spectrograph). In addition, we attempted to anticipate the needs of future space-borne solar studies such as from the joint ESA/NASA Solar and Heliospheric Observatory (SOHO) spacecraft. Our laboratory activities stressed two categories of study: (1) the measurement of absolute rate coefficients for dielectronic recombination and electron impact excitation; and (2) the measurement of atomic transition probabilities for solar density diagnostics. A brief summary of the research activity is provided.

Parkinson, W. H.↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

The Mg 2 lines as diagnostic of PMS nature in Herbig Ae/Be stars

The main objective of this program was to observe some newly discovered and previously unobserved Herbig Ae/Be (HAeBe) stars with IUE. A previous archival study suggested that there was a full range of profiles in the Mg II lines for these objects; ranging from the double peak emission to the narrow absorption lines. It has been found that by studying the IUE data of main sequence B and classical Be stars that the P Cygni profiles in the Mg II lines in HAeBe stars are truly unique and are the signature of accelerating winds in their extended circumstellar material. The arguement, for the purposes of this proposal, that the structure of the Mg II lines was a superior diagnostic of the dynamical activity and ultimately the PMS nature of these objects. This program was a follow up study of several interesting intermediate-mass stars with the goal of classifying these objects based on the shape of their MG II lines. A list of publications resulting from this research is included.

Source record↗

Fast-ion D{alpha} measurements of the fast-ion distribution (invited)

The fast-ion D{alpha} (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-{alpha} light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of D{alpha} light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of {approx}1 ms, {approx}10 keV, and {approx}2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of {approx}50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating single-particle dynamics in magnetized plasmas: The RMF code

The RMF (Rotating Magnetic Field) code is designed to calculate the motion of a charged particle in a given electromagnetic field. It integrates Hamilton’s equations in cylindrical coordinates using an adaptive predictor-corrector double-precision variable-coefficient ordinary differential equation solver for speed and accuracy. RMF has multiple capabilities for the field. Particle motion is initialized by specifying the position and velocity vectors. Here, the six-dimensional state vector and derived quantities are saved as functions of time. A post-processing graphics code, XDRAW, is used on the stored output to plot up to 12 windows of any two quantities using different colors to denote successive time intervals. Multiple cases of RMF may be run in parallel and perform data mining on the results. Recent features are a synthetic diagnostic for simulating the observations of charge-exchange-neutral energy distributions and RF grids to explore a Fermi acceleration parallel to static magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99 Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An advanced hypervelocity aerophysics facility - A ground-based flight-test range

The paper discusses a concept for a ground-based flight-test facility, a large aeroballistic range capable of launching models large enough to permit the installation of significant amounts of onboard instrumentation. The large model size would also provide thick shock/boundary layers, thus providing the opportunity to measure flow-field properties via advanced offboard diagnostics. Current fabrication technology should permit the construction of a two-stage light-gas gun capable of accelerating 20 to 25 cm diameter models to velocities on the order of 6 km/sec. An electromagnetic launcher or a ram accelerator is considered as a potential means for achieving larger model sizes and/or greater launch velocities. Possible methods for obtaining and recording data are discussed as are the test chamber and model deceleration section requirements.

Witcofski, R. D.↗