Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Second Validation Testing of Canberra-Obayashi Mobile type TruckScan Pre-production Unit - 17214

Canberra Industries, Inc., (Now, Mirion Technologies (Canberra), Inc.), has developed and validated a new truck monitoring system 'Mobile TruckScan (MTSCAN)' for use with the Interim Storage Facilities (ISF) in Japan. MTSCAN consists of eight shielded LED-stabilized 3x3' NaI detectors. Each detector has a lead shield with a collimated view of the truck. Four detectors are placed on each side of the truck, thus 8 in total, each at about 1.1 meter from the side of the truck. These NaI detectors and collimators were calibrated by the Canberra In-Situ Object Counting System (ISOCS) mathematical efficiency calculation tool. Around the Fukushima Daiichi NPS area, the decontaminated waste was put into flexible containers called Super Sacks (SS), for transportation to the ISF, typically in 10 metric ton dump trucks. The MTSCAN pre-production unit was used to measure multiple SSs loaded into 10 ton trucks, and was able to accurately report the activity of each individual SS, with around 10-20 second acquisition time. The system can also accommodate smaller 2 ton and larger 20 ton trucks. The system is relatively compact, and therefore easy to move and setup at a different location. MTSCAN is expected to measure the SSs after loading onto trucks at the Temporary Storage Area (TSA), and at the entrance of the ISF. The MTSCAN assay results showed good accuracy in this demonstration which simulated the actual operation. From these tests, the combined standard deviation for each SS is about 20%, when compared to the reference activity from multiple Ge measurements of each sack. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Use of volumetric features for temporal comparison of mass lesions in full field digital mammograms

Purpose: Temporal comparison of lesions might improve classification between benign and malignant lesions in full-field digital mammograms (FFDM). The authors compare the use of volumetric features for lesion classification, which are computed from dense tissue thickness maps, to the use of mammographic lesion area. Use of dense tissue thickness maps for lesion characterization is advantageous, since it results in lesion features that are invariant to acquisition parameters. Methods: The dataset used in the analysis consisted of 60 temporal mammogram pairs comprising 120 mediolateral oblique or craniocaudal views with a total of 65 lesions, of which 41 were benign and 24 malignant. The authors analyzed the performance of four volumetric features, area, and four other commonly used features obtained from temporal mammogram pairs, current mammograms, and prior mammograms. The authors evaluated the individual performance of all features and of different feature sets. The authors used linear discriminant analysis with leave-one-out cross validation to classify different feature sets. Results: Volumetric features from temporal mammogram pairs achieved the best individual performance, as measured by the area under the receiver operating characteristic curve (A{sub z} value). Volume change (A{sub z} = 0.88) achieved higher A{sub z} value than projected lesion area change (A{sub z} = 0.78) in the temporal comparison of lesions. Best performance was achieved with a set that consisted of a set of features extracted from the current exam combined with four volumetric features representing changes with respect to the prior mammogram (A{sub z} = 0.90). This was significantly better (p = 0.005) than the performance obtained using features from the current exam only (A{sub z} = 0.77). Conclusions: Volumetric features from temporal mammogram pairs combined with features from the single exam significantly improve discrimination of benign and malignant lesions in FFDM mammograms compared to using only single exam features. In the comparison with prior mammograms, use of volumetric change may lead to better performance than use of lesion area change.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach to Application Validation of Multispectral Sensors Using AVIRIS

High-resolution multispectral data are becoming widely available for commercial and scientific use. For specific applications, such as agriculture studies, there is a need to quantify the performance of such systems. In many cases, parameters such as GSD and SNR can be optimized. Data sets with varying GSD's for the Landsat ETM+ bands were produced to evaluate the effects of GSD on various algorithms and transformations, such as NDVI, principal component analysis, unsupervised classification, and mixture analysis. By showing that AVIRIS data can be used to simulate spaceborne and airborne multispectral platforms over a wide range of GSD, this research can be used to assist in band selection and spatial resolution specifications for new sensors and in optimization of acquisition strategies for existing multispectral systems.

Warner, Amanda↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

SU-E-E-12: Validation of the Implementation of Different CT Scanners in Proton Treatment Planning

Purpose: To quantify the impact of the relationship of CT number and Relative Stopping Power (RSP) among different CT-scanners in the evaluation of dose distribution, for different tumor sites and proton therapy modalities like Pencil Beam and Uniform Scanning. Methods: The same tissue characterization phantom was used to analyze the difference in the X-rays energy spectra of 2 CT scanners of the same vendor. One CT is for planning and the other for treatment verification. The Hounsfield unit (HU) variations and associated dosimetric uncertainty were investigated in uniform scanning and pencil beam treatment plans of different sites. At the same time comparisons of the CT calibration curve were done using the same acquisition protocols. The phantom was imaged on a 16 multi-row CT scanner, with energies of 120 and 140 kVp,currents of 263 and 245 mA and slice thickness of 2 and 3mm respectively. The dosimetric uncertainty of the plans was evaluated in a homogeneus phantom comparing DVHs, gamma index criteria 3% 3mm, and range between them. Results: The variation of HU was within the standard deviation of the average for each tissue substitute. The curves fitted with a bilinear interpolation show a maximum deviation in high density materials like cortical bone and solid water, where the HU values deviated more than 0,6% for the 120kVp protocol. For the others curves the deviation was more than 2% for low densities materials. The gamma index uncertainty criteria passed in all the cases. Conclusion: The HU variations for the different scanners were ≤3%. Lower than the 3,5% uncertainties considered in our treatment planning system. The dosimetric analysis shows that the X-ray spectrum has a small effect on the HU-RSP curve, allowing the use of a single tissue characterization curve in our proton treatment planning system for plans verifications.

60 APPLIED LIFE SCIENCES↗

Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array which have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality during CT protocol optimization, especially when investigating the effects of new technologies.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-13: PET Image Noise Variability and Its Consequences for Quantifying Tumor Hypoxia

Purpose: The values in a PET image which represent activity concentrations of a radioactive tracer are influenced by a large number of parameters including patient conditions as well as image acquisition and reconstruction. This work investigates noise characteristics in PET images for various image acquisition and image reconstruction parameters. Methods: Different phantoms with homogeneous activity distributions were scanned using several acquisition parameters and reconstructed with numerous sets of reconstruction parameters. Images from six PET scanners from different vendors were analyzed and compared with respect to quantitative noise characteristics. Local noise metrics, which give rise to a threshold value defining the metric of hypoxic fraction, as well as global noise measures in terms of noise power spectra (NPS) were computed. In addition to variability due to different reconstruction parameters, spatial variability of activity distribution and its noise metrics were investigated. Patient data from clinical trials were mapped onto phantom scans to explore the impact of the scanner’s intrinsic noise variability on quantitative clinical analysis. Results: Local noise metrics showed substantial variability up to an order of magnitude for different reconstruction parameters. Investigations of corresponding NPS revealed reconstruction dependent structural noise characteristics. For the acquisition parameters, noise metrics were guided by Poisson statistics. Large spatial non-uniformity of the noise was observed in both axial and radial direction of a PET image. In addition, activity concentrations in PET images of homogeneous phantom scans showed intriguing spatial fluctuations for most scanners. The clinical metric of the hypoxic fraction was shown to be considerably influenced by the PET scanner’s spatial noise characteristics. Conclusion: We showed that a hypoxic fraction metric based on noise characteristics requires careful consideration of the various dependencies in order to justify its quantitative validity. This work may result in recommendations for harmonizing QA of PET imaging for multi-institutional clinical trials.

60 APPLIED LIFE SCIENCES↗

Supply Chain Based Solution to Prevent Fuel Tax Evasion: Proof of Concept Final Report

The goal of this research was to provide a proof-of-concept (POC) system for preventing non-taxable (non-highway diesel use) or low-taxable (jet fuel) petrochemical products from being blended with taxable fuel products and preventing taxable fuel products from cross-jurisdiction evasion. The research worked to fill the need to validate the legitimacy of individual loads, offloads, and movements by integrating and validating, on a near-real-time basis, information from global positioning system (GPS), valve sensors, level sensors, and fuel-marker sensors.

02 PETROLEUM↗

Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.

Lewandowski, Edward J.↗

Optimization of Concurrent Deployments of the Juvenile Salmon Acoustic Telemetry System and Other Hydroacoustic Equipment at John Day Dam

The purpose of this report is to document the results of the acoustic optimization study conducted at John Day Dam during January and February 2008. The goal of the study was to optimize performance of the Juvenile Salmon Acoustic Telemetry System (JSATS) by determining deployment and data acquisition methods to minimize electrical and acoustic interference from various other acoustic sampling devices. Thereby, this would allow concurrent sampling by active and passive acoustic methods during the formal evaluations of the prototype surface flow outlets at the dam during spring and summer outmigration seasons for juvenile salmonids. The objectives for the optimization study at John Day Dam were to: 1. Design and test prototypes and provide a total needs list of pipes and trolleys to deploy JSATS hydrophones on the forebay face of the powerhouse and spillway. 2. Assess the effect on mean percentage decoded of JSATS transmissions from tags arrayed in the forebay and detected on the hydrophones by comparing: turbine unit OFF vs. ON; spill bay OPEN vs. CLOSED; dual frequency identification sonar (DIDSON) and acoustic Doppler current profiler (ADCP) both OFF vs. ON at a spill bay; and, fixed-aspect hydroacoustic system OFF vs. ON at a turbine unit and a spill bay. 3. Determine the relationship between fixed-aspect hydroacoustic transmit level and mean percentage of JSATS transmissions decoded. The general approach was to use hydrophones to listen for transmissions from JSATS tags deployed in vertical arrays in a series perpendicular to the face of the dam. We used acoustic telemetry equipment manufactured by Technologic and Sonic Concepts. In addition, we assessed old and new JSATS signal detectors and decoders and two different types of hydrophone baffling. The optimization study consisted of a suite of off/on tests. The primary response variable was mean percentage of tag transmissions decoded. We found that there was no appreciable adverse effect on mean percentage decoded for JSATS transmitters from: turbine operations; spillway operations; DIDSON/ADCP acoustic energy; and PAS hydroacoustic systems at transmit level of -12 dB, although there was a significant impact at all higher transmit levels (-11 to -6 dB). The main conclusion from this optimization study is that valid JSATS telemetry data can be collected simultaneously with a DIDSON/ADCP and a PAS hydroacoustic system at transmit level -12 dB. Multiple evaluation tools should be considered to increase the robustness and thoroughness of future fish passage evaluations at John Day and other dams.

13 HYDRO ENERGY↗

Active learning path-dependent properties using a cloud-based materials acceleration platform

Solid state materials are central to many modern technologies in which a given material may be exposed to a variety of environments. The material properties often vary with the sequence of environments in an irreversible manner, resulting in a quintessential path-dependency in experimental observables. While sequential learning techniques have been effectively deployed for accelerating learning of state properties of materials, they often use a consistent environment path in all experiments. To elevate such techniques for making optimal decisions in experimental investigations of path-dependent properties, we introduce an iterated expected information gain acquisition function that optimizes over entire experimental trajectories. This approach is implemented within a cloud-based Materials Acceleration Platform architecture utilizing an event-driven stateful broker coupled with remote HELAO (Hierarchical Experimental Laboratory Automation and Orchestration) instances and an AI science manager. The platform's efficacy was demonstrated through a case study optimizing multi-step spectro-electrochemical experiments to identify optically stable potential windows in (Co–Ni–Sb)O z metal oxides. The system successfully integrated AI-driven experiment design, remote laboratory automation, and cloud-based data infrastructure, validating the platform's capability for managing complex, adaptive, path-dependent workflows in materials discovery.

Guevarra, Dan [California Institute of Technology ↗

Integration of LIBS with Machine Learning for Real-Time Monitoring of Feedstock in H 2 Gasification Applications

This project, funded by the U.S. Department of Energy (DOE) – Office of Fossil Energy under Award Number DE-FE0032177, aimed to assess the feasibility of an integrated Laser-Induced Breakdown Spectroscopy (LIBS) system with advanced machine learning (ML) models for real-time characterization and potential control of hydrogen gasifiers running on waste materials as feedstocks. This was a multidisciplinary effort that encompassed the acquisition and standardized analysis of individual and blended feedstocks—comprising biomass, coal waste, and plastic waste, followed by the development of a dynamic LIBS bench system for material sample analysis and development of predictive ML models. Comprehensive laboratory testing enabled the creation of a robust elemental dataset that served as the foundation for ML model training. Techniques such as Random Forest, Gradient Boosting, Support Vector Regression, and Neural Networks were employed to predict key feedstock properties, including higher heating value (HHV), moisture content, thermal conductivity, and ash composition with high accuracy. The results were validated against experimental data and demonstrated strong potential for real-time application in gasifier control systems. The project concluded with a study on the integration of the LIBS+ML approach for gasifier control and a techno-economic analysis of the implementation of the approach into hydrogen (H 2 ) gasification systems. Dissemination of results was carried out at a DOE meeting. This work establishes a scalable framework for automated, in-line feedstock quality assessment, offering significant implications for process optimization and emissions reduction in hydrogen production.

01 COAL, LIGNITE, AND PEAT↗

Acoustic Testing of the Joby Aviation Propeller in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel

The advanced air mobility sector has progressed in recent years with electric vertical take-Off and landing vehicles at the forefront. In response, the NASA Advanced Air Mobility Project has initiated the Advanced Air Mobility National Campaign to partner with industry to progress this emerging market. This resulted in NASA’s Revolutionary Vertical Lift Technology project to participate to progress research efforts for software tool validation for these advanced air mobility vehicle configurations. Noise has been identified as one of the main obstacles to succeeding in this emerging market for community acceptance. To further understand electric vertical take-Off and landing vehicle noise, an isolated Joby Aviation S4 propeller was tested in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel to aid in providing high quality performance, loads, and acoustic data. Details of test hardware and setup are described with a focus on acoustics, which includes facility, test model, microphone locations, and data acquisition system details. Additionally, the data processing techniques and completed test matrix for acoustic points are provided. To aid in identifying potential acoustic reflections, an acoustic reflection test was performed prior to the start of the test and highlighted the presence of reflections at every microphone location. Acoustic results are provided for various flight regimes for sweeps of blade pitch, RPM, flow angle, and wind speed. These results show an optimum RPM for a specific thrust level for noise, and further reductions in RPM can increase noise levels. This dataset will be used to evaluate and improve computational tools.

Aviation Propeller↗

Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface

Cosmic rays are energetic nuclei and elementary particles that originate from stars and intergalactic events. The interaction of these particles with the upper atmosphere produces a wide range of secondary particles that reach the surface of the earth, of which muons are the most prominent. With enough energy, muons can travel up to a few kilometers beneath the surface of the earth before being stopped completely. The terrestrial muon flux profile and associated zenith angle can be utilized to determine geological characteristics of a location (e.g., rock overburden and density) without having to use conventional methods such as boreholes. This work uses a low-power plastic scintillator-based muon detection system as a prototype for this non-destructive geological assay methodology. Four custom designed 102 cm x 51 cm x 5 cm plastic scintillation panels are used to realize two orthogonal detection planes. Optical photons from each scintillation panel are read using OnSemi J-Series 4x4 silicon photomultiplier (SiPM) arrays in conjunction with preamplifiers. Simultaneous triggers between detectors from two planes indicate a coincidence event which is recorded using the QuarkNet data acquisition system (DAQ) from Fermi National Accelerator Laboratory. A custom detector holder was designed to securely mount the detection system and rotate the panels along the zenith to collect data at variable angles. In order to quantify the systematic uncertainties associated with the detector, such as energy depositions and angular resolution of the detector design, a Monte Carlo (MC) simulation using Geant4 is being developed. Cosmic ray flux prediction will be included in the project by adding the CORSIKA MC code to the simulation toolchain. Simulated and experimental data will drive the development and validation of a reconstruction algorithm that, upon completion, is expected to predict average overburden and rock density. Extended detector exposure to muons can be used as a means to understand changes in the surrounding environment like rock porosity. On the experimental front, muons will initially be measured at the surface, establishing the baseline flux. This is followed by recording the muon flux at variable depths and zenith angles, where the data will be used by the reconstruction algorithm to predict the overburden. The result will be benchmarked against geological surveys. The measured flux data will also be used to benchmark independent and established models. Successful proof-of-concept demonstration of this technology can open doors for long term non-invasive geological monitoring. The detector design, experimental methodology, and the benchmarking efforts are detailed in this work.

Gadey, Harish Reddy↗

Validation and Verification of the Correct Operation of the Savannah River National Laboratories, Model SRNL-Rev. 2, Serial # SRNL-003 Coulometer.

In August of 2011, C-AAC successfully installed a new coulometer. This system was only the third ever built of a newly redesigned system that SRNL had completed. The other two new systems reside at the IAEA in Vienna and at SRNL in South Carolina. The new system will replace an old PAR173 system that had been the workhorse of the Plutonium Assay team since the early 1970s. This 40+ year old system was not computer compatible and no longer had available spare parts. Upon the request of the IAEA and C-AAC personnel, the SRNL team undertook a project to modernize their systems and completely revamped the electronics and data acquisition system of their coulometry models (designed and built in the early 1990’s) by combining all electronics on a single, multilayer printed circuit board with individual isolated ground and power planes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗