Search NASA⌕ Search

SEARCH · Search NASA

Results for “applied physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

DECADE+DES Y3 Weak Lensing Mass Map: A 13,000 deg$^2$ View of Cosmic Structure from 270 Million Galaxies

We present the largest galaxy weak lensing mass map of the late-time Universe, reconstructed from 270 million galaxies in the DECADE and DES Year 3 datasets, covering 13,000 square degrees. We validate the map through systematic tests against observational conditions (depth, seeing, etc.), finding the map is statistically consistent with no contamination. The large area covered by the mass map makes it a well-suited tool for cosmological analyses, cross-correlation studies and the identification of large-scale structure features. We demonstrate its potential by detecting cosmic filaments directly from the mass map for the first time and validating them through their association with galaxy clusters selected using the Sunyaev-Zeldovich effect from Planck and ACT DR6.

Gatti, M. [Chicago U., KICP] (ORCID:00000001613487↗

A DECADE of dwarfs: first detection of weak lensing around spectroscopically confirmed low-mass galaxies

We present the first detection of weak gravitational lensing around spectroscopically confirmed dwarf galaxies, using the large overlap between DESI DR1 spectroscopic data and DECADE/DES weak lensing catalogs. A clean dwarf galaxy sample with well-defined redshift and stellar mass cuts enables excess surface mass density measurements in two stellar mass bins ($\log \rm{M}_*=[8.2, 9.2]~M_\odot$ and $\log \rm{M}_*=[9.2, 10.2]~M_\odot$), with signal-to-noise ratios of $5.6$ and $12.4$ respectively. This signal-to-noise drops to $4.5$ and $9.2$ respectively for measurements without applying individual inverse probability (IIP) weights, which mitigates fiber incompleteness from DESI's targeting. The measurements are robust against variations in stellar mass estimates, photometric shredding, and lensing calibration systematics. Using a simulation-based modeling framework with stellar mass function priors, we constrain the stellar mass-halo mass relation and find a satellite fraction of $\simeq 0.3$, which is higher than previous photometric studies but $1.5σ$ lower than $Λ$CDM predictions. We find that IIP weights have a significant impact on lensing measurements and can change the inferred $f_{\rm{sat}}$ by a factor of two, highlighting the need for accurate fiber incompleteness corrections for dwarf galaxy samples. Our results open a new observational window into the galaxy-halo connection at low masses, showing that future massively multiplexed spectroscopic observations and weak lensing data will enable stringent tests of galaxy formation models and $Λ$CDM predictions.

To, Chun-Hao [Chicago U., Astron. Astrophys. Ctr.;↗

The DECam MAGIC Survey $-$ Mapping the Ancient Galaxy in CaHK: Overview and Summary of Early Science

We present the DECam Mapping the Ancient Galaxy in CaHK (MAGIC) survey, a 54-night NOIRLab Survey Program to image $\gtrsim$5,000$\,$deg$^2$ of the southern hemisphere using a metallicity-sensitive narrow-band filter covering the Ca$\,$ii$\,$H&K lines centered at 3955$\,$A. This filter is installed on the Dark Energy Camera (DECam), mounted on the 4-m NSF Víctor M. Blanco Telescope. The survey reaches typical $10σ$ depths of $\text{mag}_{\text{CaHK}} \approx 22.5$, 3$-$4$\,$mag deeper than comparable surveys in the southern hemisphere. By combining photometry from this Ca$\,$ii$\,$H&K filter with existing DECam $g,r,i$ broadband photometry from the DECam Local Volume Exploration (DELVE) survey, MAGIC is deriving photometric metallicities for red giant branch stars down to the magnitude limit of usable proper motions from Gaia data release 3 (DR3). MAGIC has already imaged $\sim$3,000$\,$deg$^2$, supplemented by other affiliated observing programs that have used this filter to image star clusters, dwarf galaxies, and stellar streams. We overview MAGIC's survey strategy, describe data processing through the derivation of metallicities and photometric distances, and summarize early science results that have been published with this dataset. In addition, we present several new results, including the confirmation of a distant ($>5\,r_h$) member of the Reticulum II ultra-faint dwarf galaxy, on-sky density maps of low-metallicity stars into the distant Milky Way halo ($\sim150\,$kpc) recovering 13/14 ultra-faint dwarf galaxies in the current footprint, and a validation of our initial targeting of extremely metal-poor stars. Collectively, these results demonstrate that the MAGIC dataset enables cutting-edge studies of the faint, low-metallicity regime of the Milky Way and its substructures.

Chiti, A. [KIPAC, Menlo Park] (ORCID:0000000271556↗

Physical characterization of uranium oxide pellets and powder applied in the Nuclear Forensics International Technical Working Group Collaborative Materials Exercise 4

Physical characterization is one of the most broad and important categories of techniques to apply in a nuclear forensic examination. Physical characterization techniques vary from simple weighing and dimensional measurements to complex sample preparation and scanning electron microscopy-electron backscatter diffraction analysis. This paper reports on the physical characterization conducted by several international laboratories participating in the fourth Collaborative Materials Exercise, organized by the Nuclear Forensics International Technical Working Group. Methods include a range of physical measurements, microscopy-based observations, and profilometry. In conclusion, the value of these results for addressing key investigative questions concerning two uranium dioxide pellets and a uranium dioxide powder is discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nb SRF cavities applied to searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can al-low to achieve unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics. Using Nb SRF cavities, we run a proof of principle search for the dark photon dark matter candidate at fixed frequency demonstrating the deepest sensitivity to wavelike dark mater [1]. The Dark SRF experiment uses two 1.3GHz SRF cavities to conduct a light shining through wall (LSW) experiment to attempt producing and detecting dark photons in the laboratory. The results of this first superconducting LSW search were recently published [2] and we are now working on the second phase of the experiment, which will be run in a dilution refrigerator using 2.6GHz SRF cavities. In addition to the limits we have achieved, we will also present the experiments we are currently developing, such as the heterodyne axion DM search [3, 4], the SERAPH series of experiments, and gravitational waves searches based on SRF cavities as proposed in [5-8].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonequilibrium orbital transitions via applied electrical current in calcium ruthenates

Simultaneous control of structural and physical properties via applied electrical current poses a new, key research topic with both fundamental and technological significance. Studying the spin-orbit-coupled antiferromagnet Ca 2 RuO 4 , and its derivative with 3% Mn doping to alleviate the violent first-order transition at 357 K, we find that a small applied electrical current couples to the lattice by significantly reducing its orthorhombic distortions and octahedral rotations, while concurrently diminishing the 125-K antiferromagnetic transition. Further increasing electrical current density above 0.15A/cm 2 induces a new nonequilibrium orbital state, with a transition signature at 80 K that features a simultaneous jump in both magnetization and electrical resistivity, sharply contrasting the current-free state. Here, we argue that nonequilibrium electron occupancies of the $t_{2g}$ orbitals stabilized by applied current drive the observed lattice changes and thereby the novel phenomena in this system. Finally, we note that current-induced diamagnetism reported in recent literature [C. Sow et al., Science 358, 1084 (2017).] is not discerned in either slightly doped or pure Ca 2 RuO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spray-on electrodes enable EKG monitoring of physically active subjects

Easily applied EKG electrodes monitor the heart signals of human subjects engaged in various physical exercises. The electrodes are formed from an air drying, electrically conductive cement mixture that can be applied to the skin by means of a modified commercially available spray gun.

Source record↗

Physical bioenergetics: Energy fluxes, budgets, and constraints in cells

Cells are the basic units of all living matter which harness the flow of energy to drive the processes of life. While the biochemical networks involved in energy transduction are well-characterized, the energetic costs and constraints for specific cellular processes remain largely unknown. In particular, what are the energy budgets of cells? What are the constraints and limits energy flows impose on cellular processes? Do cells operate near these limits, and if so how do energetic constraints impact cellular functions? Physics has provided many tools to study nonequilibrium systems and to define physical limits, but applying these tools to cell biology remains a challenge. Physical bioenergetics, which resides at the interface of nonequilibrium physics, energy metabolism, and cell biology, seeks to understand how much energy cells are using, how they partition this energy between different cellular processes, and the associated energetic constraints. In this work, we review recent advances and discuss open questions and challenges in physical bioenergetics.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Resistive Wall Mode Stabilization Physics in High-beta Plasmas Using Applied Non-axisymmetric Fields in NSTX

The National Spherical Torus Experiment (NSTX) offers an operational space characterized by high-beta (βt = 39%, βN > 7, βN/βno-wall N > 1.5) and low aspect ratio (A > 1.27) to leverage the plasma parameter dependences of RWM stabilization and plasma rotation damping physics giving greater confidence for extrapolation to ITER. Significant new capability for RWM research has been added to the device with the commissioning of a set of six nonaxisymmetric magnetic field coils, allowing generation of fields with dominant toroidal mode number, n, of 1–3. These coils have been used to study the dependence of resonant field amplification on applied field frequency and RWMstabilization physics by reducing the toroidal rotation profile belowits steady-state value through non-resonant magnetic braking. Modification of plasma rotation profiles shows that rotation outside q = 2.5 is not required for passive RWM stability and there is large variation in the RWM critical rotation at the q = 2 surface, both of which are consistent with distributed dissipation models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiple Facets of the Poisson Distribution Applicable to Health Physics Measurements

This paper discusses several ways to view the standard Poisson distribution as applied to health physics scaler counts. The intent is not so much to present calculational details but rather to present some underlying concepts. Examples are provided that illustrate the various concepts for several types of specific measurements. The concepts presented involve purely Poisson-based contributions to variance; extra-Poisson variance is presently ignored, and any counting system would be presumed to function properly and without counting loss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Random walk of magnetic field lines in dynamical turbulence: A field line tracing method. I. Slab turbulence

To study the wandering of magnetic field lines is an important subject in theoretical physics. Results of field line random walk theories can be applied in plasma physics as well as astrophysics. Previous investigations are based on magnetostatic models. These models have been used in analytical work as well as in computer simulations to warrant mathematical and numerical tractability. To replace the magnetostatic model by a dynamical turbulence model is a difficult task. In the present article, a field line tracing method is used to describe field line wandering in dynamical magnetic turbulence. As examples different models are employed, namely, the plasma wave model, the damping model of dynamical turbulence, and the random sweeping model. It is demonstrated that the choice of the turbulence model has a very strong influence on the field line structure. It seems that if dynamical turbulence effects are included, Markovian diffusion can be found for other forms of the wave spectrum as in the magnetostatic model. Therefore, the results of the present paper are useful to specify turbulence models. As a further application we consider charged particle transport at early times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of isotopic composition of reprocessed uranium during the multiple recycling in light water reactors with natural uranium feed

A complex approach based on the consistent modeling of neutron-physics processes and processes of cascade separation of isotopes is applied for analyzing physical problems of the multiple usage of reprocessed uranium in the fuel cycle of light water reactors. A number of scenarios of multiple recycling of reprocessed uranium in light water reactors are considered. In the process, an excess absorption of neutrons by the {sup 236}U isotope is compensated by re-enrichment in the {sup 235}U isotope. Specific consumptions of natural uranium for re-enrichment of the reprocessed uranium depending on the content of the {sup 232}U isotope are obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of the Geant4 Simulation Toolkit to Medical Physics - Paper 65

We show how the Geant4 Simulation Toolkit, originally developed for High Energy Physics, has been applied to a wide variety of challenging applications in medical physics. As the authors are mainly responsible for providing assistance to Geant4 users in North America, they draw on examples from the North American experience, but the conclusions can be generalized to the Geant4 medical user community worldwide. Geant4 is already heavily used in all areas of medical physics, from external beam therapy to brachytherapy to interventional nuclear medicine and medical imaging. As the complexity of medical physics studies continues to increase, requiring greater accuracy of modeling, and an increase in 4D capabilities (component motion and time-varying electric and magnetic fields), Geant4 use will only expand. The openness of the HEP community (keeping Geant4 well supported, open and free) is greatly appreciated by the medical and aerospace communities. The democratic nature of Geant4's governance (that decision-making rests with a technical steering board elected by the collaborators) has given outside communities the confidence to invest their energies in Geant4 (shown them that it is worth the time investment to become expert users). Geant4's latest key area of focus, moving to multithreaded operation, is seen as a huge boon to the medical users (where precision simulations often require billions of primary particles). Another recent key area of Geant4, increasing automated systems for unit and end-to-end testing, is also seen as extremely valuable to these non-HEP communities. Innovations from HEP and aerospace will benefit medical applications, and vice versa. Geant4 can expect increasing resources to be provided by the medical physics community, pooling resources to the benefit of all users. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-244: Validation of a 6D-Robotic-Couch and Image Guidance Radiation Therapy (IGRT) System for Localization in World's First Single-Room Proton Therapy System

Purpose: The Mevion S250 proton therapy unit is equipped with a 6D-robotic couch and IGRT system (Verity). The patient alignment process allows corrections in six degrees of freedom: translation (x,y,z), pitch, roll, and yaw (θ,ϑ,ψ). Geometric accuracy of couch corrections and imaging vs. radiation isocenter coincidence were quantified before clinical implementation. Methods: A commercial phantom with sixteen 2mm tungsten BBs was rigidly couch-mounted and imaged with CT. Seventeen rigid translations/rotations of known magnitude were digitally applied to the original CT image using commercial software, validated with Varian OBI system. For each altered image, phantom was mounted on robotic couch in original position, then Verity 2D:2D match (PA-LLAT) was performed using DRRs from altered images. Corrections were recorded and applied, phantom was imaged a second time and residual corrections recorded. Physical measurements verified that applied couch corrections coincided with both physical couch shifts/rotations and known CT image translations/rotations. Additionally, image vs. radiation isocenter coicidence was quantified over couch treatment angles (±90° from setup position) using radiochromic film and an image-guided couch star-shot. Posterior-anterior and left-lateral kV radiographs were taken before each beam was delivered to verify imaging/radiation isocentricity. Results: Verity suggested couch corrections and known CT shifts/rotations agreed within ±1mm (average: Δ lat=0.5mm; Δ vert=0.4mm; Δ long=0.3mm) and ± 0.4° (average: Δ pitch=0.24° Δ roll=0.01°; Δ yaw=0.10°). Physical couch measurements and Verity applied corrections agreed within ± 1mm (average: Δlat=0.5mm; Δvert=0.4mm; Δlong=0.2mm) and ±0.2° (average: Δpitch=0.03°; Δ roll=0.04°; Δ yaw=0.04°). The directionality of all translations and rotations were qualitatively verified. The image vs. radiation isocenter coincidence was <1mm and radiation-isocenter precision was <1mm over the 180° of couch motion, as indicated by film analysis. Conclusion: The Verity IGRT software and 6D-couch combination on the Mevion S250 was verified as accurate within 1mm and 0.5°. This complies with the TG-142 standards for a stereotactic radiotherapy IGRT system. Rob Cessac is employed as Product Manager for Mevion Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Preconditioning of a High-Order Solver for Multiple Physics

This work addresses preconditioning approaches for an implicit high-order solver frame-work applied to multiple physics. The solver is based on a space-time spectral element method and matrix-free Newton-Krylov solver developed at NASA over the recent years. Within this context, most preconditioning methods are impractical, as the computational time and memory requirements scale poorly with increasing polynomial orders. To improve computational efficiency, we first describe a novel entity-based Block Jacobi preconditioner for the continuous-Galerkin solution of the linear-elasticity and linear-shell equations. Second, we introduce a multigrid algorithm to further reduce time-to-solution on stiff cases arising from continuous-and discontinuous-Galerkin discretizations. Results obtained on relevant single-physics reference solutions, demonstrate the feasibility of the methods, paving the way for high-order solutions of fully coupled multi-physics problems.

STMD↗