Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

SU-F-T-460: Dosimetric Matching Between Trilogy Tx and TrueBeam STx

Purpose: To compare the commissioned beam data for one flattening filter photon mode (6 MV) and two flattening filter-free (FFF) photon modes (6 and 10 MV-FFF) between Trilogy Tx and TrueBeam STx and evaluate the possibility of dosimetric matching Methods: Dosimetric characteristics of the new Trilogy Tx including percent depth doses (PDDs), profiles, and output factors were measured for commissioning. Linear diode array detector and ion chambers were used to measure dosimetric data. The depth of dose maximum (dmax) and PDD at 10 cm (PDD10) were evaluated: 3×3 cm{sup 2}, 10×10 cm{sup 2}, and 40×40 cm{sup 2}. The beam profiles were compared and then penumbras were evaluated. As a further test of the dosimetric matching, the same VMAT plans were delivered, measured with film, and compared with TPS calculation. Results: All the measured PDDs matched well across the two units. PDD10 showed less than 0.5% variation and dmax were within 1.5 mm at the field sizes evaluated. Within the central 80% of transverse axis, profile data were almost identical. TrueBeam data resulted in a slightly greater penumbra width (up to 1.9 mm). The greatest differences of output factors were found at 40 × 40 cm{sup 2}: 2.40%, 2.03%, and 2.22% for 6 MV, 6 MV-FFF, and 10 MV-FFF, respectively. For smaller field sizes, less than 1% differences were observed. The film measurements demonstrated over 97.3% pixels passing-gamma analysis (2%/2mm). The results showed excellent agreement between measurements of two machines. Conclusion: The differences between Trilogy Tx and TrueBeam STx found could possibly affect small field and also very large field sizes in dosimetric matching considerations. These differences encountered are mostly related with the changes in the head design of the TrueBeam. Although it cannot guarantee full interchangeability of two machines, dosimetric matching by field size of 25 × 25 cm{sup 2} might be clinically acceptable.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-643: Feasibility of Performing Patient Specific VMAT QA On Single Linac for Plans Treated in Beam-Matched Elekta Agility Linacs

Purpose: The increasing application of VMAT demands a more efficient workflow and QA solution. This study aims to investigate the feasibility of performing VMAT QA measurements on one linac for plans treated on other beam-matched Elekta Agility linacs. Methods: A single model was used to create 24 clinically approved VMAT plans (12 head-and-neck and 12 prostate using 6MV and 10MV respectively) on Pinnacle v9.10 (Philips, Einhoven, Netherlands). All head-and-neck plans were delivered on three beam-matched machines while all prostate cases were delivered on two beam-matched 10MV Agility machines. All plans were delivered onto PTW Octavius 4D phantom with 1500 detector array (PTW, Freiburg, Germany). Reconstructed volume doses were then compared with the Pinnacle reference plans in Verisoft 6.1 under 3%/3mm gamma criteria at local dose. Plans were considered clinically acceptable if >90% of the voxels passing the gamma criteria. Results: All measurements were passed (3D gamma passing rate >90%) and the result shows that the mean difference of 3D gamma of 12 head-and-neck cases is 1.2% with standard deviation of 0.6%. While for prostate cases, the mean difference of 3D gamma is 0.9% with standard deviation of 0.7%. Maximum difference of 3D gamma of all measurements between beam-matched machines is less than 2.5%. The differences of passing rates between different machines were statistically insignificant (p>0.05). Conclusion. The result suggests that ther Conclusion: The result suggests that there exists a 3D gamma threshold, in our case 92.5%, above which the VMAT QA performed in any one of beam-matched machine will also pass in another one. Therefore, VMAT QA efficiency may be increased and phantom set up time can be saved by implementing such method. A constant performance across all beam matched machines must be maintained to make this QA approach feasible.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden), with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.

60 APPLIED LIFE SCIENCES↗

A Quantum Random Number Generator Based on the 100-Mbit/s Poisson Photocount Statistics

A quantum random number generator is experimentally realized. The initial randomness source is a sequence of photocounts from quasi-single-photon radiation detected with a SiPM (Silicon Photo Multiplier) silicon avalanche detector array. The use of a SiPM provides a reliable control of the quantum nature of the Poisson photocount statistics. A special algorithm with nonexponential complexity allows one to extract from the Poisson process all the randomness contained in it, namely, a random uniform sequence of 0 and 1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isospin aspects in nuclear reactions involving Ca beams at 25 MeV/nucleon

Isospin dependence of dynamical and thermodynamical properties observed in reactions {sup 40}Ca+ {sup 40,48}Ca and {sup 40}Ca + {sup 46}Ti at 25 MeV/nucleon has been studied. We used the CHIMERA multi-detector array. Strong isospin effects are seen in the isotopic distributions of light nuclei and in the competition between different reaction mechanisms in semi-central collisions. We will show also preliminary results obtained in nuclear collision {sup 48}Ca + {sup 48}Ca at 25MeV/nucleon, having very high N/Z value in the entrance channel (N/Z = 1.4). The enhancement of evaporation residue production confirms the strong role played by the N/Z degree of freedom in nuclear dynamics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiparticle-hole excitations in nuclei near N = Z = 20: $^{41}$K

This experimental study of high-spin structure near the N = Z = 20 region focuses on 41 K and also reports three newly observed γ transitions in 41 Ca from the same reaction. High-spin states were populated using the 26 Mg( 18 O, p2nγ) 41 K and 26 Mg( 18 O, 3nγ) 41 Ca reactions at a beam energy of 50 MeV at the Florida State University John D. Fox Superconducting Linear Accelerator Laboratory, employing the FSU high-purity germanium detector array. The level scheme of 41 K was extended to 12325 keV, possibly up to J π = 25/2 − or 27/2 + , by means of 25 new γ-ray transitions, and that of 41 Ca to 9916 keV. Linear polarization and angular-distribution measurements were used to provide spin and parity information for several states in the 41 K decay scheme. The results are compared with spsdpf cross-shell shell-model calculations using the FSU interaction. Configurations involving zero or one nucleon promoted from the sd to the fp shell reproduce the energies of many known states reasonably well, while multi-particle excitations reveal a more complex interplay of single-particle motion, collective pairing, and deformation, posing an interesting challenge for future theoretical work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton branching ratios in 22 Mg for X-ray bursts

Here, decay protons from 22 Mg energy levels populated through a previously reported 24 Mg(p, t) 22 Mg transfer reaction (Chae et al. in Phys Rev C 79:055804, 2009) have been analyzed for proton branching ratios as a follow-up analysis. The measurement was performed at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory by utilizing 41-MeV proton beams and 24 Mg solid targets. Decay protons and reaction tritons were simultaneously detected with a silicon detector array. By investigating the 24 Mg(p, t) 22 Mg*(p) 21 Na channels, the proton branching ratios of five 22 Mg excited states were obtained. The measured branching ratios provide constraints on the proton partial widths of the populated 22 Mg levels, which have implications for X-ray burst nucleosynthesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetimes of excited states in $^{16}$C as a benchmark for ab initio developments

Lifetimes of higher-lying states ($2_2^+$ and $4_1^+$) in 16 C have been measured, employing the Gammasphere and Microball detector arrays, as key observables to test and refine ab initio calculations based on interactions developed within chiral Effective Field Theory. The presented experimental constraints to these lifetimes of $\tau ({2_2^+}) = [244, 446]\,~\textrm{fs}$ and $\tau ({4_1^+}) = [1.8, 4]\,~\textrm{ps}$, combined with previous results on the lifetime of the $2_1^+$ state of 16 C, provide a rather complete set of key observables to benchmark the theoretical developments. We present No-Core Shell-Model calculations using state-of-the-art chiral 2- (NN) and 3-nucleon (3N) interactions at next-to-next-to-next-to-leading order for both the NN and the 3N contributions and a generalized natural-orbital basis (instead of the conventional harmonic-oscillator single-particle basis) which reproduce, for the first time, the experimental findings remarkably well. The level of agreement of the new calculations as compared to the CD-Bonn meson-exchange NN interaction is notable and presents a critical benchmark for theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The background in the $0\nu \beta \beta $ experiment Gerda

The GERmanium Detector Array (Gerda) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta (0νββ) decay of 76 Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the Q ββ value of the decay. To avoid bias in the signal search, the present analysis does not consider all those events, that fall in a 40 keV wide region centered around Q ββ. The main parameters needed for the 0νββ analysis are described. A background model was developed to describe the observed energy spectrum. The model contains several contributions, that are expected on the basis of material screening or that are established by the observation of characteristic structures in the energy spectrum. The model predicts a flat energy spectrum for the blinding window around Qββ with a background index ranging from 17.6 to 23.8 × 10 -3 cts/(keV kg yr). A part of the data not considered before has been used to test if the predictions of the background model are consistent. The observed number of events in this energy region is consistent with the background model. The background at Q ββ is dominated by close sources, mainly due to 42 K, 214 Bi, 228 60 Co and α emitting isotopes from the 226 Ra decay chain. The individual fractions depend on the assumed locations of the contaminants. It is shown, that after removal of the known γ peaks, the energy spectrum can be fitted in an energy range of 200 keV around Q ββ with a constant background. This gives a background index consistent with the full model and uncertainties of the same size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results on $\beta \beta $ decay with emission of two neutrinos or Majorons in $^{76}$ Ge from GERDA Phase I: GERDA Collaboration

A search for neutrinoless ββ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1,2,3,7 were searched for. No signals were found and lower limits of the order of 10 23 yr on their half-lives were derived, yielding substantially improved results compared to previous experiments with 76 Ge. A new result for the half-life of the neutrino-accompanied ββ decay of 76Ge with significantly reduced uncertainties is also given, resulting in T 2ν 1/2 = (1.926 ± 0.094) × 10 21 yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Limit on the radiative neutrinoless double electron capture of 36 Ar from GERDA Phase I

Neutrinoless double electron capture is a process that, if detected, would give evidence of lepton number violation and the Majorana nature of neutrinos. Here, a search for neutrinoless double electron capture of 36 Ar has been performed with germanium detectors installed in liquid argon using data from Phase I of the GERmanium Detector Array (Gerda) experiment at the Gran Sasso Laboratory of INFN, Italy. No signal was observed and an experimental lower limit on the half-life of the radiative neutrinoless double electron capture of 36 Ar was established: T 1/2 > 3.6 × 10 21 years at 90% CI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Following transient phases at the air/water interface

A fast pixel array detector, the Pilatus 100 K, has been used in studies of organic monolayers at the air-water interface. The area sensitivity and large dynamic range of the detector, in combination with a 'one dimensional pinhole' geometry, make it possible to observe surface processes which were inaccessible to the previous generation of experimental techniques. Especially, time dependent phenomena acting on time scales ranging from seconds to minutes can be observed and analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PROBING SINGLE-NEUTRON LEVELS IN 127,129Sn VIA TRANSFER REACTIONS

The (d,p) reaction was measured with radioactive ion beams of 126Sn and 128Sn (~5 MeV/u) in inverse kinematics at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory, utilizing the SuperORRUBA silicon detector array. Angular distributions of reaction protons were measured for several states in 127Sn and 129Sn in order to determine angular momentum transfers and deduce spectroscopic factors. Combined with previous experiments on 130Sn and 132Sn, these results provide a complete set of (d,p) reaction data on even tin isotopes between stable 124Sn and doubly magic 132Sn.

Manning, B.↗

Study of Rare Nuclear Processes with CUORE

TeO 2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO 2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$ meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130 Te and the hypothesized electron capture in 123 Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO 2 bolometers, and perspectives for CUORE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New levels in spherical 96 Y

New transitions in neutron rich 96 Y have been identified by analyzing the high statistics γ-γ-γ and γ-γ-γ-γ coincidence data from the spontaneous fission of 252 Cf at the Gammasphere detector array. Shell model calculations were performed and are found in good agreement with experimental data. In conclusion, the ground state is nearly spherical but a new excited band has large deformation.

252Cf↗