Search NASA⌕ Search

SEARCH · Search NASA

Results for “circularity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Enhanced Collimated GeV Monoenergetic Ion Acceleration from a Shaped Foil Target Irradiated by a Circularly Polarized Laser Pulse

Using multidimensional particle-in-cell simulations we study ion acceleration from a foil irradiated by a circularly polarized laser pulse at 10{sup 22} W/cm{sup 2} intensity. When the foil is shaped initially in the transverse direction to match the laser intensity profile, three different regions (acceleration, transparency, and deformation region) are observed. In the acceleration region, the foil can be uniformly accelerated for a longer time compared to a usual flat target. Undesirable plasma heating is effectively suppressed. The final energy spectrum of the accelerated ion beam in the acceleration region is improved dramatically. Collimated GeV quasi-monoenergetic ion beams carrying as much as 19% of the laser energy are observed in multidimensional simulations.

43 PARTICLE ACCELERATORS↗

Radiation-Pressure Acceleration of Ion Beams Driven by Circularly Polarized Laser Pulses

We present experimental studies on ion acceleration from ultrathin diamondlike carbon foils irradiated by ultrahigh contrast laser pulses of energy 0.7 J focused to peak intensities of 5x10{sup 19} W/cm{sup 2}. A reduction in electron heating is observed when the laser polarization is changed from linear to circular, leading to a pronounced peak in the fully ionized carbon spectrum at the optimum foil thickness of 5.3 nm. Two-dimensional particle-in-cell simulations reveal that those C{sup 6+} ions are for the first time dominantly accelerated in a phase-stable way by the laser radiation pressure.

43 PARTICLE ACCELERATORS↗

Recollisions and Correlated Double Ionization with Circularly Polarized Light

It is generally believed that the recollision mechanism of atomic nonsequential double ionization is suppressed in circularly polarized laser fields because the returning electron is unlikely to encounter the core. On the contrary, we find that recollision can and does significantly enhance double ionization, even to the extent of forming a ''knee,'' the signature of the nonsequential process. Using a classical model, we explain two apparently contradictory experiments, the absence of a knee for helium and its presence for magnesium.

74 ATOMIC AND MOLECULAR PHYSICS↗

Circularly Polarized X Rays: Another Probe of Ultrafast Molecular Decay Dynamics

Dissociative nuclear motion in core-excited molecular states leads to a splitting of the fragment Auger lines: the Auger-Doppler effect. We present here for the first time experimental evidence for an Auger-Doppler effect following F1s{yields}a{sub 1g}* inner-shell excitation by circularly polarized x rays in SF{sub 6}. In spite of a uniform distribution of the dissociating S-F bonds near the polarization plane of the light, the intersection between the subpopulation of molecules selected by the core excitation with the cone of dissociation induces a strong anisotropy in the distribution of the S-F bonds that contributes to the scattering profile measured in the polarization plane.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hybridized kagome bands and induced Ti magnetism in RTi3Bi4 (R = Nd, Sm, Gd) kagome metals studied using angle-resolved photoemission spectroscopy and x-ray magnetic circular dichroism

Kagome materials are known for hosting emergent quantum phenomena driven by the interaction between different lattice, charge and spin orders. Here, we present a detailed angle resolved photoemission (ARPES), density functional theory (DFT) and x-ray magnetic circular dichroism (XMCD) study of the electronic and magnetic structure of RTi3Bi4 (R = Nd, Sm, Gd). ARPES and DFT demonstrate that the bulk electronic band structure is dominated by the hybridization of the Ti bands, and the weak electron-like pocket at Γ is identified as a surface state. The isotropic XAS profile of the M 4,5-edge of the rare earth is consistent with the presence of R 3+ oxidation state. Using the XMCD sum rules, backed by the atomic multiplet theory calculations, we obtain the spin and orbital magnetic moments. The Ti L2,3-edge XMCD reveals the presence of a small magnetic moment in GdTi3Bi4, presumably driven by the proximity of the Ti kagome layers to the zigzag chains of Gd, while the total magnetic moment of Gd is shared by the f and d electrons. Our combined XMCD, ARPES and DFT study brings an important piece of information to understand the spin flip transitions and anomalous Hall effect observed in the RTi3Bi4 kagome metals.

Lim, C.↗

Local X-ray magnetic circular dichroism study of Fe/Cu(111) using a tunneling smart tip

Localized spectroscopy with simultaneous topographic, elemental and magnetic information is presented. A synchrotron X-ray scanning tunneling microscope has been employed for the local study of the X-ray magnetic circular dichroism at the Fe L 2,3 -edges of a thin iron film grown on Cu(111). Polarization-dependent X-ray absorption spectra have been obtained through a tunneling smart tip that serves as a photoelectron detector. In contrast to conventional spin-polarized scanning tunneling microscopy, X-ray excitations provide magnetic contrast even with a non-magnetic tip. Intensity variations in the photoexcited tip current point to chemical variations within a single magnetic Fe domain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proposed measurement of the reverse Cherenkov radiation effect in a metamaterial-loaded circular waveguide

The authors have recently proposed an experiment on verification of the Reverse Cherenkov Radiation (RCR) effect in a Left-Handed-Material-loaded waveguide. Applications of the RCR effect may range from novel higher-order-mode suppressors in microwave and millimeter-wave sources to improved particle detectors for satellite non-proliferation missions. The experimental configuration includes a circular waveguide filled with an artificial metamaterial with simultaneously negative permittivity and permeability, in which the electromagnetic wave with a frequency of 95 GHz will interact with an electron beam. They have demonstrated that for certain values of effective permittivity and permeability only the backward-propagating mode can be exited by the electron beam. At the conference they will present some newly developed metamaterial designs, which they plan to employ for producing the proper effective medium parameters for this experiment.

36 MATERIALS SCIENCE↗

High Temperature Superconducting Quadrupole Magnets With Circular Coils

Particle accelerators used various rather low field mag-nets. In the paper described recently proposed the novel concept of using circular superconducting coils for multipole iron-dominated magnets. This type of magnet design is most suitable for using high temperature superconductors (HTS), and react and wind technol-ogy. The HTS quadrupole magnet with 45 mm aperture, and 100 mm diameter coils was designed, fabricated, and tested. The magnet design includes: the choice of superconductor, 3D magnetic field op-timization, and mechanical design. Furthermore, the magnet models were tested at the liquid nitrogen temperature. The test results are presented and discussed.

2G conductors, coils↗

Radiation of a Charge Intersecting a Boundary Between a Bilayer Area and a Homogeneous One in a Circular Waveguide

This paper is devoted to the analysis of electromagnetic field excited by a charge moving in a circular waveguide, which consists of two semi-infinite parts. The charge moves with a constant velocity along the waveguide axis from the partially dielectric section into the homogeneous one. It is assumed that Cherenkov radiation is generated in the bilayer section. The total field is represented as a sum of a known forced field that is the field of the charge in the infinite regular waveguide and a free field resulting from the presence of the transverse boundary. The infinite system of algebraic equations for amplitudes of the free-field modes is derived. The further analysis is conducted using numerical calculations. Special attention is given to the study of the so-called Cherenkov-transition radiation (CTR) within the homogeneous part of the waveguide volume. Typical distributions of CTR over frequencies and modes are presented for the case when the channel and the homogeneous area are free of medium. Analytical results obtained for the point charge are generalized for the charged bunch with an arbitrary profile and verified using direct simulations for the case of Gaussian bunch.

Cherenkov-transition radiation (CTR)↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Circular Trajectory Approach for Online Sinusoidal Signal Distortion Monitoring and Visualization

The increasing complexity and uncertainties of modern power systems are placing significant demands on signal monitoring techniques. This work proposes the Circular Trajectory Approach (CTA) for online sinusoidal signal distortion monitoring and visualization. CTA can detect distortions of a sinusoidal signal. Compared with existing waveform anomaly detection techniques, CTA is faster in detection and less computation intensive. It thus supports edge devices and online applications. CTA also offers a new means of sinusoidal signal distortion visualization. It can reveal the distorted sections in a sinusoidal cycle and clearly display the distortions. The proposed approach is tested on real data from an open source EPRI dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hsa_circ_0000515 is a novel circular RNA implicated in the development of breast cancer through its regulation of the microRNA‐296‐5p/CXCL10 axis

Cancer metastasis is a major cause of death among women afflicted with breast cancer (BC) and understanding the molecular processes involved is a major focus in BC research. Circular RNAs (circRNAs) have emerged as genomic regulatory molecules in carcinogenesis and metastasis; however, their role in BC is unclear. We characterized a novel circRNA, hsa_circ_0000515, in context of BC. We collected 340 cancerous tissues surgically resected from BC patients and found hsa_circ_0000515 was upregulated in BC tissues and associated with poor prognosis of BC. Silencing of hsa_circ_0000515 impaired cell cycle progression, cell proliferation, and invasion, attenuated inflammatory response, and reduced the proangiogenetic potential of BC cells. RNA pull‐down and dual‐luciferase reporter gene assays showed that hsa_circ_0000515 binds miR‐296‐5p, preventing it from repressing CXCL10 expression. We also observed that miR‐296‐5p inhibition or CXCL10 overexpression promoted cell cycle progression, restored proliferative, invasive and proangiogenetic abilities, and increased inflammatory response in MCF‐7 cells in the absence of hsa_circ_0000515. In vivo analyses showed that partial loss of hsa_circ_0000515 reduced the tumor growth of MCF‐7 cells in nude mice. The key findings from this study revealed that targeting hsa_circ_0000515 might be an effective strategy to combat BC.

Cai, Fenglin↗

Attached and Attaching Three-Dimensional Jets from Circular Nozzles: Analytical Model

Here we evaluate velocity profiles of three dimensional attached jets emerging from circular nozzles. These jets lose momentum due to interactions with nearby surfaces and are important to evaluating flows in mixing vessels and to suspending solids and trapped gases in radioactive waste tanks. Despite the industrial importance of attached jets, simple, complete, and quantitative expressions for their velocity profiles remain elusive. Here we present a quantitative analytical model of the three dimensional velocity profiles of attached jets inclusive of a local skin coefficient of friction. We compare these expressions to experimental velocity profiles at moderate and high nozzle Reynolds numbers to find reasonable quantitative agreement.

Jet, attached jet, offset jet, reattaching offset ↗

Plasma-free hydrogenation of oxygen-terminated polycrystalline diamond as determined by circular transmission line measurements (CTLM)

Here, we developed a process to fully hydrogen-terminate diamond by annealing in forming gas. The surface was characterized using circular transmission line measurements (CTLMs) to evaluate the onset and degree of hydrogen termination. No hydrogenation occurred at temperatures at or below 500 °C. Hydrogenation occurs after annealing for 5 min at temperatures between 600 and 1000 °C, with complete hydrogenation achieved at 1000 °C, which showed the same sheet resistance as diamond terminated in a hydrogen plasma. Annealing at temperatures lower than 1000 °C resulted in only partial hydrogenation but can be compensated by increasing the anneal time. At temperatures exceeding 1100 °C, the sheet resistance suddenly and drastically increases, indicating instability of a hydrogen-terminated diamond surface at elevated temperatures under forming gas. The activation energy was determined to be 1.20eV. SEM inspection showed that annealing in hydrogen produced significantly reduced surface roughness compared to diamond surfaces hydrogenated in a H 2 plasma.

36 MATERIALS SCIENCE↗

Development of a broadband reflective phase retarder to generate circularly polarized light for MTW-OPAL and multipetawatt lasers

Here, our research focuses on designing metallic coatings to create broadband all-reflective phase retarders that generate circularly polarized (CP) light for the MTW-OPAL Laser System while ensuring the desired polarization state on the target. This all-reflective phase retarder can function as a phase retarder when used in an out-of-plane configuration, whereas it acts as a normal mirror set in an in-plane configuration. If the polarization of the beam is not purely s- or p-polarized, however, mirrors will in general introduce retardance, and therefore compensators or polarization-independent mirror pairs are needed to ensure the desired polarization at the target plane.

47 OTHER INSTRUMENTATION↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-02: Characterizing Low-Contrast Resolution for Non-Circular CBCT Trajectories

Purpose: The use of non-circular scanning trajectories with optimization-basedreconstruction algorithms can be used in conjunction with non-planaracquisition geometries for axial field-of-view (FOV) extension incone-beam CT (CBCT). To evaluate the utility of these trajectories,quantitative image quality metrics should be evaluated. Low-contrastresolution (LCR) and CT number accuracy are significant challenges forCBCT. With unprecedented axial coverage provided by thesetrajectories, measuring such metrics throughout the axial range iscritical. There are currently no phantoms designed to measurelow-contrast resolution over such an extended volume. Methods: The CATPHAN (The Phantom Laboratory, Salem NY) is the current standardfor image quality evaluation. While providing several useful modulesfor different evaluation metrics, each module was designed to beevaluated in a single slice and not for comparison across axialpositions. To characterize the LCR and HU accuracy over an extendedaxial length, we have designed and built a phantom with evaluationmodules at multiple and adjustable axial positions. Results: The modules were made from a cast polyurethane resin. Holes rangingfrom 1/8 to 5/8 inch were added at a constant radius from the modulecenter into which rods of two different plastic materials were pressedto provide two nominal levels of contrast (1.0% and 0.5%). Largerholes were bored to accept various RMI plugs with known electrondensities for HU accuracy evaluation. The modules can be inserted intoan acrylic tube long enough to cover the entire axial FOV and theirpositions adjusted to desired evaluation points. Conclusion: This phantom allows us to measure the LCR and HU accuracy across theaxial coverage within a single acquisition. These metrics can be usedto characterize the impact different trajectories and reconstructionparameters have on clinically relevant image quality performancemetrics. Funding was provided in part by Varian Medical Systems and NIH R01 Grants Nos. CA158446, CA182264, EB018102, and EB000225. The contents of this poster are solely the responsibility of the authors and do not necessarily represent the official view of any of the supporting organizations.

60 APPLIED LIFE SCIENCES↗

X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

61 RADIATION PROTECTION AND DOSIMETRY↗