Search NASA⌕ Search

SEARCH · Search NASA

Results for “code requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Next generation commercial heat pumpwater heater using carbon dioxide using different improvement approaches

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accessorizing Building Science – A Web Platform to Support Multiple Market Transformation Programs

As demand for improved energy efficiency in homes increases, builders need information on the latest findings in building science, rapidly ramping-up energy codes, and technical requirements for labeling programs. The Building America Solution Center is a Department of Energy (DOE) website containing hundreds of expert guides designed to help residential builders install efficiency measures in new and existing homes. Builders can package measures with other media for customized content. Website content provides technical support to market transformation programs such as ENERGY STAR and has been cloned and adapted to provide content for the Better Buildings Residential Program. The Solution Center uses the Drupal open source content management platform to combine a variety of media in an interactive manner to make information easily accessible. Developers designed a unique taxonomy to organize and manage content. That taxonomy was translated into web-based modules that allow users to rapidly traverse structured content with related topics, and media. We will present information on the current design of the Solution Center and the underlying technology used to manage the content. The paper will explore development of features, such as “Field Kits” that allow users to bundle and save content for quick access, along with the ability to export PDF versions of content. Finally, we will discuss development of an Android based mobile application, and a visualization tool for interacting with Building Science Publications that allows the user to dynamically search the entire Building America Library.

Madison, Michael C.↗

Self-consistent hybrid neoclassical-magnetohydrodynamic simulations of axisymmetric plasmas

Neoclassical effects (e.g., conductivity reduction and bootstrap currents) have a profound impact on many magnetohydrodynamic (MHD) instabilities in toroidally-confined plasmas, including tearing modes, edge-localized modes, and resistive wall modes. High-fidelity simulations of such phenomena require a multiphysics code that self-consistently couples the kinetic and fluid models. We review a hybrid formulation from the recent literature AB that is appropriate for such studies. In particular, the formulation uses a set of time-dependent drift-kinetic equations (DKEs) to advance the non-Maxwellian part of the electron and ion distribution functions ( fNM ) with linearized Fokker-Planck-Landau collision operators. The form of the DKEs used were derived in a Chapman-Enskog-like fashion, ensuring that fNM carries no density, momentum, or temperature. Rather, these quantities are contained within the background Maxwellian and are evolved by a set of MHD equations which are closed by moments of fNM . We then present two DKE solvers based upon this formulation in axisymmetric toroidal geometries. The Neoclassical Ion-Electron Solver (NIES) solves the steady-state DKEs in the low-collisionality limit. Convergence and benchmark studies are discussed, providing a proof-of-principle that this new formulation can accurately reproduce results from the literature in the limit considered. We then present the DK4D code which evolves the finite-collisionality DKEs time-dependently. Computational methods used and successful benchmarks to other neoclassical models and codes are discussed. Furthermore, we couple DK4D to a reduced, transport-timescale MHD code. The resulting hybrid code is used to simulate the evolution of the current density in a large-aspect-ratio plasma in the presence of several different time-dependent pressure profiles. These simulations demonstrate the self-consistent, dynamic formation of the ohmic and bootstrap currents. In the slowly-evolving plasmas considered, these first-principle simulations are shown to verify a simpler, steady-state neoclassical model that is commonly used in transport codes. Future work will involve coupling DK4D to a spatially three-dimensional, extended MHD code, generalizing DK4D to nonaxisymmetric geometries, and simulating more quickly-evolving and realistic plasmas. The ultimate goal of this work is to perform self-consistent, hybrid simulations of complex tokamak instabilities and calculations of neoclassical toroidal viscosity. A J. J. Ramos, Phys. Plasmas 17 , 082502 (2010). B J. J. Ramos, Phys. Plasmas 18 , 102506 (2011).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolving Applications of Aerosol Sealant

Solving the issues facing the residential building industry today requires developing not only new technologies but also new, innovative applications of existing high-performance technologies. The U.S. Department of Energy's (DOE's) Building America Program is using this approach to develop a low-cost, easy solution for whole-home envelope air sealing. Aerosol sealant is a proven method for sealing ducts quickly and efficiently, especially in hard-to-reach places. This technology, originally developed at Lawrence Berkeley National Laboratory in 1994 with support from DOE, seals 70%-90% of duct leaks (LBNL n.d.), saving $600-$850 per year in energy costs for an average household (DOE 2011). A new, innovative application takes this technology out of the duct system and into the conditioned space. Recent Building America projects have validated a method for whole-house air sealing using the aerosol sealant technology. With tighter envelope requirements in new codes and above-code programs, adequately air sealing by hand is more labor-intensive and costly than ever. The aerosol sealing method is designed to eliminate the guesswork and automate this process. The continuous measurement during installation allows builders to dial in the exact air tightness they need to meet their performance goals. Initial field testing shows that this method regularly achieves air leakage levels less than 1 ACH50 as measured by a blower door test. In a current Building America project, the Center for Energy and Environment is performing iterative field tests in 20 homes to identify the optimal integration and sequencing of this method in production home building processes to achieve a lower installation cost than traditional air sealing. This method has the potential to improve quality assurance of envelope sealing and significantly reduce labor costs compared with traditional air sealing approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temporal Analysis Of Product Computational Methods

The temporal analysis of products (TAP) reactor provides a wealth of data for transient studies of gas phase heterogeneous reactions, with the ability to provide a comprehensive picture of intrinsic reaction kinetics pertaining to complex catalytic mechanisms. A novel framework called the Y-Procedure was previously developed by Yablonsky and coworkers to extract information from this non-steady-state kinetic data. The Y-Procedure reconstructs the chemical transformation rate and gas composition in the catalytic zone with no a priori assumptions on the kinetic model and is used to relate changes in catalytic reaction rates and kinetic parameters to changes in a catalyst’s surface composition. This code provides the required steps to pre-process, analyze, and perform the Y-Procedure on experiments derived from the TAP reactor.

Kunz, Matthew R.↗

Permanent Electrical Loads in New Homes

Numerous electrical products and components are installed by the builder during construction and prior to occupancy. Some of these components are required by safety codes, such as smoke detectors, others are needed to support the communications infrastructure, and still others provide features that future occupants will find useful, such as remotely controlled garage door openers. We compiled a list of over 50 builder-installed devices that are likely to have continuous power consumption, and measured the power consumptions for a smaller group. A procedure to measure these loads in a home was developed based on readings from the smart meter. A typical American home can easily have 80 W of continuous power – over 650 kWh/year – devoted to these components. New homes are likely to have more of these devices and higher loads. Techniques to reduce this energy use include: selection of lowest-power solutions when a range of power consumptions are available, more efficient circuitry and power management, a separate DC circuit to serve DC-powered appliances, and use of energyscavenging sensors and controls in place of grid-powered components. A protocol to define and measure builder-installed loads, along with a recommended ceiling, might also stimulate savings.

Meier, Alan↗

Decision Support Tool for Solar Energy Cybersecurity Policy and Regulation

The Decision Support Tool helps users address four discrete challenges: (1) complex requirements of relevant codes and standards, (2) technical complexity of solar assets, (3) undefined cyber risk severity, and (4) unclear roles and responsibilities. Content includes an analysis of cyber vulnerability risks, a decision support resource for policymakers to mitigate cyber risks to solar photovoltaic systems, and background resources for informing policy development. A key component of this tool is the Probable Risk Assessment (PRA), based on established, formal variables, models, and consequences, which helps users understand the determined risk and assigned ownership of the physical components. It helps states draw logical lines between vulnerabilities and mitigative solutions, of which some have been further detailed as Cybersecurity Advisory Team for State Solar (CATSS) tools.

14 SOLAR ENERGY↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of subchannel and averaged channel thermal-hydraulic descriptions on coupled pin-by-pin neutronic calculations

Best-estimate transient analysis of Light Water Reactors (LWRs) requires high accuracy code systems solving neutronics (NK), thermal-hydraulics (TH) and thermal-mechanics to model the core behavior. For long time, nodal diffusion methods for solution of the transport equation using assembly size computational meshes have been applied neglecting the details within the fuel assembly, or using 'pin power reconstruction' techniques to predict those details. Moreover, the multiphysics analysis has been commonly performed coupling those neutronic diffusion methods to thermal-hydraulic system codes using a nodalization of several fuel assemblies per computational node without taking into account the effects that this type of averaging can have on the results obtained. This paper presents the work accomplished with the coupled system COBAYA4/CTF for a preliminary analysis of the effect of the different accuracy levels in the NK and TH domain. COBAYA4 is a neutronic code able to solve the diffusion equation at two resolution levels, nodal and pin by pin (PbP). CTF is a thermo-hydraulic code able to solve the coolant conservation equations also at two levels, channel (fuel assembly averaged solution) and sub-channel (real cooling channel) level. The coupled system COBAYA4/CTF is used through SALOME platform, i.e. SALOME is the software able to map conveniently the NK and TH meshes. This coupling allows combining different resolution levels for NK and TH problems. Therefore, the study of the effect of using different resolutions for the NK and TH nodalizations has been performed applying the system to a fuel assembly with selected boundary conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAS4A/SASSYS-1 Modeling Improvements for the Transition to Natural Circulation

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. In recent years, SAS has undergone a number of improvements to enable improved safety analyses that meet end users’ modernized needs while complying with the current regulatory environment. Improvements made in versions 5.6 and 5.7 released within the last year include the development of anisotropic Reynolds number dependent loss coefficients throughout the core and heat transport systems, the ability to distinguish the transition friction factor from the fully developed laminar and turbulent friction factors, and timedependent direct coolant and wall heating for pipe-like elements in the heat transport systems. While it was possible to capture loss coefficients, friction factors, and heat transfer from an element to a heat sink within SAS in previous versions of the code, users were required to end the simulation and restart it to adjust the input to account for any significant changes to the values during the transient. With these improvements, users can better capture flow reversal, pump heating, and the transition from forced to natural circulation without being limited to constant orifice coefficients, constant heat sinks, or the need to restart the simulation and modify input. In order to demonstrate the application of these improvements, a loss of flow transient is simulated for the Advanced Burner Test Reactor (ABTR).

SAS4A/SASSYS-1↗

Model representation in the PANCOR wall interference assessment code

An investigation into the aircraft model description requirements of a wall interference assessment and correction code known as PANCOR was conducted. The accuracy necessary in specifying various elements of the model description were defined. It was found that the specified lift coefficient is the most important model parameter in the wind tunnel simulation. An accurate specification of the model volume was also found to be important. Also developed was a partially automated technique for generating wing lift distributions that are required as input to PANCOR. An existing three dimensional transonic small disturbance code was modified to provide the necessary information. A group of auxiliary computer programs and procedures was developed to help generate the required input for PANCOR.

Al-Saadi, Jassim A.↗

Assessment of Current Jet Noise Prediction Capabilities

An assessment was made of the capability of jet noise prediction codes over a broad range of jet flows, with the objective of quantifying current capabilities and identifying areas requiring future research investment. Three separate codes in NASA s possession, representative of two classes of jet noise prediction codes, were evaluated, one empirical and two statistical. The empirical code is the Stone Jet Noise Module (ST2JET) contained within the ANOPP aircraft noise prediction code. It is well documented, and represents the state of the art in semi-empirical acoustic prediction codes where virtual sources are attributed to various aspects of noise generation in each jet. These sources, in combination, predict the spectral directivity of a jet plume. A total of 258 jet noise cases were examined on the ST2JET code, each run requiring only fractions of a second to complete. Two statistical jet noise prediction codes were also evaluated, JeNo v1, and Jet3D. Fewer cases were run for the statistical prediction methods because they require substantially more resources, typically a Reynolds-Averaged Navier-Stokes solution of the jet, volume integration of the source statistical models over the entire plume, and a numerical solution of the governing propagation equation within the jet. In the evaluation process, substantial justification of experimental datasets used in the evaluations was made. In the end, none of the current codes can predict jet noise within experimental uncertainty. The empirical code came within 2dB on a 1/3 octave spectral basis for a wide range of flows. The statistical code Jet3D was within experimental uncertainty at broadside angles for hot supersonic jets, but errors in peak frequency and amplitude put it out of experimental uncertainty at cooler, lower speed conditions. Jet3D did not predict changes in directivity in the downstream angles. The statistical code JeNo,v1 was within experimental uncertainty predicting noise from cold subsonic jets at all angles, but did not predict changes with heating of the jet and did not account for directivity changes at supersonic conditions. Shortcomings addressed here give direction for future work relevant to the statistical-based prediction methods. A full report will be released as a chapter in a NASA publication assessing the state of the art in aircraft noise prediction.

Hunter, Craid A.↗

Demonstration of μCHP in Light Commercial Hot Water Applications

Internal combustion engine driven combined heat and power (CHP) systems produce power while the waste heat is recovered and used for another purpose. For µCHP systems (less than 50kWe output) overall efficiencies can reach over 90% for products currently on the market throughout the world. On a fuel basis this offers an advantage over using grid-based power and another fuel for heat. Additionally, the cost of natural gas on an energy unit basis is significantly less expensive than electric power. This difference can lead to substantial savings for the end user of a CHP system. In some parts of the world, particularly Germany and Japan, µCHP has become a common part of the heat and distributed generation equipment mix. Market analysis conducted in 2012 showed that in North America there is potential of a 5,300 units per year market for µCHP, resulting in an annual energy savings of approximately 13.5 TBtu and more than $84 million in annual customer savings. However, µCHP still has not seen much market penetration in North America. This study helps to identify some of the reasons why, address roadblocks that still need to be overcome and provide experience to established best practices. Nine commercial sites were initially identified (fitness club, surgical center, senior community, resort and spa, commercial laundry, two multi-family housing, restaurant and manufacturing facility). Systems from two different manufacturers were installed at five sites total, but due to unforeseen circumstances, only three of those sites were finally commissioned: test data were collected by Oak Ridge National Laboratory. While not all systems were installed as intended, the project resulted in the following key findings: Micro combined heat and power is an unfamiliar technology for building owners and plumbing and electrical contractors that serve the buildings most suited for µCHP. Manufacturers will need to be aggressive in providing training and providing broad support to successfully bring the technology to market.; The proper integration of µCHP into other building systems is the most critical part of a successful installation. Manufacturers will need to be able to provide the expertise to train, advise and support the mechanical contractors during the design and installation of the heat integration system.; Regulations governing µCHP varies across the country. There are a few UL standards (UL 2200 and UL 1741) that apply nationally. Emissions are governed by EPA except in California where the California Air Resources Board (CARB) has established their own standard. Requirements that dictate installation and interconnection are dependent on local building codes and local utility processes and requirements. Some out of date building codes do not offer clear guidance for these requirements, leading to confusion. This makes developing training and determining broadly applicable best practices difficult.; Installation costs of µCHP are a key factor in making an installation successful. It is critical that these costs and all national, state and local regulations be understood and accounted for by all parties involved in the installation before a project is undertaken.; A robust customer service organization is important to meet the needs of the customers. These systems require annual maintenance and service and local capability is needed to keep costs inline.

03 NATURAL GAS↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Photosensitive Glass based X-ray Anti-scattering Grid by using MCNP code - Paper 6

It is required to protect individual against the dangers of ionizing radiation from medical exposure. And in order to increase accuracy of radiography and radiotherapy, it is essential to remove scattered radiation. Therefore, to satisfy these, proper anti-scattering x-ray grid is required. An anti-scattering grid is composed of penetration material and shielding material. Many studies have been carried out about fabricating x-ray anti-scattering grid by lithography. Lithography gives benefit of getting high aspect ratio and makes it easy to have smooth and thin fabrication. Photosensitive glass is focused on because it has advantages for laser fabrication. UV laser micro fabrication technology is used widely in VLSI, and other micro systems. These technologies can be employed into anti-scattering grid because it is also requires precise fabrication. In this study, it includes computer simulation of grid with photosensitive glass. Some models are adopted and analyzed by using MCNP code and the efficiencies are estimated. (authors)

36 MATERIALS SCIENCE↗

FastPM: a new scheme for fast simulations of dark matter and haloes

We introduce FASTPM, a highly scalable approximated particle mesh (PM) N-body solver, which implements the PM scheme enforcing correct linear displacement (1LPT) evolution via modified kick and drift factors. Employing a two-dimensional domain decomposing scheme, FASTPM scales extremely well with a very large number of CPUs. In contrast to Comoving-Lagrangian (COLA) approach, we do not require to split the force or track separately the 2LPT solution, reducing the code complexity and memory requirements. We compare FASTPM with different number of steps (N s ) and force resolution factor (B) against three benchmarks: halo mass function from friends-of-friends halo finder; halo and dark matter power spectrum; and cross-correlation coefficient (or stochasticity), relative to a high-resolution TREEPM simulation. We show that the modified time stepping scheme reduces the halo stochasticity when compared to COLA with the same number of steps and force resolution. While increasing N s and B improves the transfer function and cross-correlation coefficient, for many applications FASTPM achieves sufficient accuracy at low N s and B. For example, N s = 10 and B = 2 simulation provides a substantial saving (a factor of 10) of computing time relative to N s = 40, B = 3 simulation, yet the halo benchmarks are very similar at z = 0. We find that for abundance matched haloes the stochasticity remains low even for N s = 5. FASTPM compares well against less expensive schemes, being only 7 (4) times more expensive than 2LPT initial condition generator for N s = 10 (N s = 5). Some of the applications where FASTPM can be useful are generating a large number of mocks, producing non-linear statistics where one varies a large number of nuisance or cosmological parameters, or serving as part of an initial conditions solver.

79 ASTRONOMY AND ASTROPHYSICS↗

Code package for calculating modified cosmic ionization and thermal histories with dark matter and other exotic energy injections

Here we present a new public Python package, DarkHistory, for computing the effects of dark matter annihilation and decay on the temperature and ionization history of the early universe. DarkHistory simultaneously solves for the evolution of the free electron fraction and gas temperature, and for the cooling of annihilation/decay products and the secondary particles produced in the process. Consequently, we can self-consistently include the effects of both astrophysical and exotic sources of heating and ionization, and automatically take into account backreaction, where modifications to the ionization/temperature history in turn modify the energy-loss processes for injected particles. We introduce a number of worked examples, demonstrating how to use the code in a range of different configurations, in particular for arbitrary dark matter masses and annihilation/decay final states. Possible applications of DarkHistory include mapping out the effects of dark matter annihilation/decay on the global 21 cm signal and the epoch of reionization, as well as the effects of exotic energy injections other than dark matter annihilation/decay. The code is available at https://github.com/hongwanliu/DarkHistory with documentation at https://darkhistory.readthedocs.io. Data files required to run the code can be downloaded at https://doi.org/10.7910/DVN/DUOUWA.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A bandwidth efficient coding scheme for the Hubble Space Telescope

As a demonstration of the performance capabilities of trellis codes using multidimensional signal sets, a Viterbi decoder was designed. The choice of code was based on two factors. The first factor was its application as a possible replacement for the coding scheme currently used on the Hubble Space Telescope (HST). The HST at present uses the rate 1/3 nu = 6 (with 2 (exp nu) = 64 states) convolutional code with Binary Phase Shift Keying (BPSK) modulation. With the modulator restricted to a 3 Msym/s, this implies a data rate of only 1 Mbit/s, since the bandwidth efficiency K = 1/3 bit/sym. This is a very bandwidth inefficient scheme, although the system has the advantage of simplicity and large coding gain. The basic requirement from NASA was for a scheme that has as large a K as possible. Since a satellite channel was being used, 8PSK modulation was selected. This allows a K of between 2 and 3 bit/sym. The next influencing factor was INTELSAT's intention of transmitting the SONET 155.52 Mbit/s standard data rate over the 72 MHz transponders on its satellites. This requires a bandwidth efficiency of around 2.5 bit/sym. A Reed-Solomon block code is used as an outer code to give very low bit error rates (BER). A 16 state rate 5/6, 2.5 bit/sym, 4D-8PSK trellis code was selected. This code has reasonable complexity and has a coding gain of 4.8 dB compared to uncoded 8PSK (2). This trellis code also has the advantage that it is 45 deg rotationally invariant. This means that the decoder needs only to synchronize to one of the two naturally mapped 8PSK signals in the signal set.

Pietrobon, Steven S.↗