Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Reaction of turbulence at the edge and in the center of the plasma column to pulsed impurity injection caused by the sputtering of the wall coating in L-2M stellarator

Impurity injection into plasma caused by the sputtering of the wall coating in the L-2M stellarator during auxiliary electron cyclotron resonance heating leads to a change in the level of plasma density fluctuations with frequencies above 0.25 MHz: suppression of long-wavelength (k{sub ⊥} = 2 cm{sup –1}) density fluctuations in the edge plasma, intensification of short-wavelength (k{sub ⊥} = 30 cm{sup –1}) and long-wavelength (k{sub ⊥} = 1 cm{sup –1}) fluctuations at the midradius of the plasma column, and intensification of short-wavelength fluctuations (k{sub ⊥} = 20 cm{sup –1}) in the plasma center (including the gyroresonance region). At the same time, the level of fluctuations with frequencies below 0.25 MHz remains unchanged. In the edge plasma, a decrease in the plasma potential and suppression of its fluctuations is observed during impurity injection, which also causes an increase in MHD activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Plasmon Resonances of an Axially Magnetized Plasma Column in the Presence of Collisional Loss

Surface plasmon resonances arising in the course of scattering of an H-polarized plane electromagnetic wave by an axially magnetized plasma column are analyzed. Main attention is paid to the behavior of these resonances in the presence of collisional loss in the magnetoplasma filling the scatterer. The frequencies, Q factors, and amplitude coefficients of the electromagnetic field of multipole surface plasmon resonances of different orders are found, and conditions under which the collisional loss in the plasma completely suppresses a given resonance are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing Near-Surface Moisture Increase during the Clear-Sky Afternoon-to-Evening Transition Using a Single-Column Model

The afternoon-to-evening transition is the period when the atmospheric boundary layer transitions from convective to stable conditions. One noticeable feature during this transition period is the rapid increase in water vapor concentration near the surface. However, the mechanism behind the increase in water vapor remains poorly understood. This study investigated the processes contributing to the water vapor increase and the impacts of the land cover and horizontal advection on the water vapor increase using a single-column model for the clear-sky condition. Numerical experiments were conducted on three cases at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site. Evapotranspiration was found to be the main moisture source to the water vapor increase, and that change of the near-surface vertical temperature gradient from negative to positive is the trigger for this increase during the afternoon-to-evening transition. This is because the near-surface turbulence divergence term decreases due to the change in the buoyancy profile caused by vertical temperature gradient change. The impact of horizontal advection on water vapor varies, and it can either lead to an increase or a decrease in water vapor, depending on the spatial horizontal water vapor gradient. This study also found that land cover can influence the timing of the water vapor increase since different land covers may have different Bowen ratios. Water vapor increases earlier under conditions with smaller Bowen ratios compared to those with larger values.

Atmosphere-land interaction↗

Investigation of the Residual in Column-Integrated Atmospheric Energy Balance Using Cloud Objects

Observationally based atmospheric energy balance is analyzed using Clouds and the Earth’s Radiant Energy System (CERES)-derived TOA and surface irradiance, Global Precipitation Climatology Project (GPCP)-derived precipitation, dry static and kinetic energy tendency and divergence estimated from ERA-Interim, and surface sensible heat flux from SeaFlux. The residual tends to be negative over the tropics and positive over midlatitudes. A negative residual implies that the precipitation rate is too small, divergence is too large, or radiative cooling is too large. The residual of atmospheric energy is spatially and temporally correlated with cloud objects to identify cloud types associated with the residual. Spatially, shallow cumulus, cirrostratus, and deep convective cloud-object occurrence are positively correlated with the absolute value of the residual. The temporal correlation coefficient between the number of deep convective cloud objects and individual energy components, net atmospheric irradiance, precipitation rate, and the sum of dry static and kinetic energy divergence and their tendency over the western Pacific are 0.84, 0.95, and 0.93, respectively. However, when all energy components are added, the atmospheric energy residual over the tropical Pacific is temporally correlated well with the number of shallow cumulus cloud objects over tropical Pacific. Because shallow cumulus alters not enough atmospheric energy compared to the residual, this suggests the following: 1) if retrieval errors associated with deep convective clouds are causing the column-integrated atmospheric energy residual, the errors vary among individual deep convective clouds, and 2) it is possible that the residual is associated with processes in which shallow cumulus clouds affect deep convective clouds and hence atmospheric energy budget over the tropical western Pacific.

54 ENVIRONMENTAL SCIENCES↗

A Novel Method for Diagnosing Land–Atmosphere Coupling Sensitivity in a Single-Column Model

The response of boundary layer properties and cloudiness to changes in surface evaporative fraction (EF) is investigated in a single-column model to quantify the locally coupled impact of subgrid surface variations on the atmosphere during summer. Sensitive coupling days are defined when the model atmosphere exhibits large variations across a range of EFs centered on the analyzed value. Coupling sensitivity exists as both positive feedback (cloudiness increases with EF) and negative feedback (clouds increase with decreasing EF) regimes. The positive regime manifests in shallow convection situations, which are capped by a strengthened inversion and subsidence, restricting the vertical extent of convection to just above the boundary layer. Surfaces with larger EF (greater surface latent heat flux) can inject more moisture into the vertically confined system, lowering the cloud base and an increasing cloud liquid water path (LWP). Negative feedback regimes tend to manifest when large-scale deep convection, such as from mesoscale convective systems and fronts, is advected through the domain, where convection strengthens over surfaces with a lower EF (greater surface sensible heat flux). The invigoration of these systems by the land surface leads to an increase in LWP through strengthened updrafts and stronger coupling between the boundary layer and the free atmosphere. These results apply in the absence of heterogeneity-induced mesoscale circulations, providing a one-dimensional dynamical perspective on the effect of surface heterogeneity. Finally, this study provides a framework of intermediate complexity, lying between parcel theory and high-resolution coupled land–atmosphere modeling, and therefore isolates the relevant first-order processes in land–atmosphere interactions.

54 ENVIRONMENTAL SCIENCES↗

Longitudinal dispersion coefficient depending on superficial velocity of hydrogen isotopes flowing in column packed with zeolite pellets at 77.4 K

Authors have been developing a cryogenic pressure swing adsorption system for hydrogen isotope separation. In the problem of its design and operation, it is necessary to predict the concentration profiles developing in packed beds of adsorbent pellets. The profiling is affected by the longitudinal dispersion of gas flowing in packed beds, in addition to the mass transfer resistance in porous media of adsorbent pellets. In this work, an equation is derived for estimating the packed-bed dispersion coefficient of hydrogen isotopes, by analyzing the breakthrough curves of trace D{sub 2} or HD replacing H{sub 2} adsorbed in synthetic zeolite particles packed columns at the liquefied nitrogen temperature 77.4 K. Since specialized for hydrogen isotopes, this equation can be considered to estimate the dispersion coefficients more reliable for the cryogenic hydrogen isotope adsorption process, than the existing equations. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equilibrium and kinetic studies of sorption of 2.4-dichlorophenol onto 2 mixtures: bamboo biochar plus calcium sulphate (BC) and hydroxyapatite plus bamboo biochar plus calcium sulphate (HBC), in a fluidized bed circulation column

Sorption studies were carried out to investigate removal of 2.4-dichlorophenol (2.4-DCP) from aqueous solution in a fluidized bed by two types of adsorbent mixtures: BC (Bamboo char plus Calcium sulphate), and HBC (Hydroxyapatite plus Bamboo char plus Calcium sulphate); both manufactured in ball shape. The main material bamboo char was characterized by FTIR, DTA and SEM. The adsorption experiments were conducted in a fluidized bed circulation column. Adsorption, isotherms and kinetic studies were established under 180 min operating process time, at different initial 2.4-DCP solution concentrations ranging from 5–10 mg/L, and at different flow rates ranging from 0.25–0.75 L/min. The data obtained fitted well for both the Langmuir and Freundlich isotherm models; indicating favorable condition of monolayer adsorption. The kinetics of both adsorbents complies with the pseudo second-order kinetic model. BC was proven a new effective composite and low cost adsorbent which can be applied in the field of wastewater treatment, and it can also play an important role in industry water treatment

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Boat-Dragged Riverbed and Mid-Column Water Quality along the Hanford Reach in the Columbia River Shorelines

This dataset contains water quality measurements used to identify sites of hydrologic exchange (i.e.hydrologic exchange flows; HEFs) in the Columbia River near Richland, WA by looking for anomalies in temperature and electrical conductivity (EC) along the bed of the river in February, June, July, August, and November 2017. These are ultimately the ‘ends’ of HEFs as they are locations of subsurface inflow to the river. This dataset contains dissolved oxygen (DO) measurements at 1-min intervals; temperature, EC, depth, and GPS coordinates at 1-second intervals; and N-NO3 at 2-min intervals along the river bed and mid-column water. DO measurements are included in this dataset for completeness but were not used in the analysis of HEFs due to the relatively long time interval of collection.

54 ENVIRONMENTAL SCIENCES↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT01, KT02, KT03, AND KT04-SERIES GLASS COMPOSITIONS

Four series of glass compositions were selected, fabricated, and characterized as part of a study to determine the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. The KT01 and KT02-series of glasses were chosen to allow for the identification of the influence of the concentrations of major components of the glass on the retention of TiO{sub 2}. The KT03 series of glasses was chosen to allow for the identification of these influences when higher Nb{sub 2}O{sub 5} and ZrO{sub 2} concentrations are included along with TiO2. The KT04 series of glasses was chosen to investigate the properties and performance of glasses based on the best available projections of actual compositions to be processed at the DWPF (i.e., future sludge batches including the SCIX streams).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical comparison of candidate ion exchange media for small column ion exchange (SCIX) applications in support of supplemental law pretreatment

At-tank supplemental pretreatment including both filtration and small column ion exchange is currently under evaluation to facilitate salt waste retrieval and processing in the Hanford tank farms. Spherical resorcinol formaldehyde (sRF) resin is the baseline ion exchange resin for use in the Waste Treatment and Immobilization Plant (WTP). This document provides background and technical rationale to assist in determining whether spherical resorcinol formaldehyde (sRF) is also the appropriate ion exchange resin for supplemental LAW pretreatment processes and compares sRF with crystalline silicotitanate (CST) as potential supplemental pretreatment ion exchange media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT05- AND KT06-SERIES GLASS COMPOSITIONS

This report is the second in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. The KT05-series glasses were selected, fabricated, and characterized to further study glass compositions where iron titanate crystals had been previously found to form. The intent was to better understand the mechanisms and compositions that favored the formation of crystals containing titanium. Formation of these crystalline phases was confirmed. Increased Na{sub 2}O concentrations had little if any impact on reducing the propensity for the formation of the iron titanate crystalline phases. Other physical properties of these glasses were not measured since the intent was to focus on crystallization. Additional studies are suggested to investigate the potential impacts of Al{sub 2}O{sub 3} and K{sub 2}O on crystallization in glasses with high TiO{sub 2} concentrations. The KT06-series glasses were selected, fabricated, and characterized to further study glass compositions that, while broader than the current projections for DWPF feeds with SCIX material, are potential candidates for future processing (i.e., the compositions are acceptable for processing by the Product Composition Control System (PCCS) with the exception of the current TiO{sub 2} concentration constraint). The chemical compositions of these glasses matched well with the target values. The chemical durabilities of all the glasses were acceptable relative to the Environmental Assessment (EA) benchmark. Minor crystallization was identified in some of the slowly cooled glasses, although this crystallization did not impact chemical durability. Several of the KT06-series compositions had durability values that, while acceptable, were not accurately predicted by the current durability models. It was shown that for these high TiO{sub 2} concentration glasses, relatively high Fe{sub 2}O{sub 3} concentrations combined with relatively high Al{sub 2}O{sub 3} concentrations led to durabilities that were unpredictable. Several of the KT06-series glasses also had measured viscosity values that were not well predicted by the current model. A statistical partitioning routine showed that the measured viscosities became unpredictable by the current model when the Fe{sub 2}O{sub 3} concentration in the glasses was less than about 8.2 wt % at the elevated TiO{sub 2} concentrations. The current durability and viscosity models will have to be further evaluated should compositions in these regions become necessary for DWPF processing. Overall, the results presented for the KT06-series glasses show that TiO{sub 2} from the SCIX streams can be incorporated into DWPF-type glasses at concentrations of 6 wt % (in glass) without any detrimental impacts on crystallization or chemical durability that are of practical importance. The measured values for chemical durability and viscosity were acceptable for processing; however, not all of the values were predictable by the current PCCS models. Since the compositions selected for the KT06-series glasses were outside the current projections for DWPF processing with the SCIX streams (in terms of waste components other than TiO{sub 2}), these results help identify compositional regions that, if necessary for processing, would require modifications to the current models. Additional experiments are currently underway. Once completed, all of the measured data will be reviewed and compared to model predictions to better determine whether the validation range of the DWPF process control models can be confidently extended, or whether refitting of the models will be necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION KT07-SERIES GLASS COMPOSITIONS

This report is the third in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. MST from the Salt Waste Processing Facility is also considered in the study. The KT07-series glasses were selected to evaluate any potential impacts of noble metals on their properties and performance. The glasses characterized thus far for the SCIX study have not included noble metals since they are not typically tracked in sludge batch composition projections. However, noble metals can act as nucleation sites in glass melts, leading to enhanced crystallization. This crystallization can potentially influence the properties and performance of the glass, such as chemical durability, viscosity, and liquidus temperature. The noble metals Ag, Pd, Rh, and Ru were added to the KT07-series glasses in concentrations based on recent measurements of Sludge Batch 6, which was considered to contain a high concentration of noble metals. The KT04-series glasses were used as the baseline compositions. After fabrication, the glasses were characterized to determine their homogeneity, chemical composition, durability, and viscosity. Liquidus temperature measurements are also underway but were not complete at the time of this report. The liquidus temperature results for the KT07-series glasses, along with several of the earlier glasses in the SCIX study, will be documented separately. All of the KT07-series glasses, both quenched and slowly cooled, were found to be amorphous by X-ray diffraction. Chemical composition measurements showed that all of the glasses met their targeted compositions. The Product Consistency Test (PCT) results showed that all of the glasses had chemical durabilities that were far better than that of the Environmental Assessment benchmark glass. The measured PCT responses were well predicted by the current DWPF Product Composition Control System (PCCS) durability models. The measured viscosity values for each KT07-series glass were acceptable for DWPF processing and were well predicted by the current PCCS model. Overall, the results show that the inclusion of relatively high concentrations of noble metals (in terms of expected values for a DWPF sludge batch) had no significant impact on the properties and performance of these glass compositions. There were no significant differences in the measured properties when compared to those of the KT04-series glasses, which did not contain noble metals. Liquidus temperature measurements are still underway and there may be an impact of the noble metals on those measurements. However, no adverse effects were noted in terms of crystallization after slow cooling. At the completion of these studies, all of the data generated will be reviewed with regard to the applicability of the DWPF PCCS models and recommendations will be made as to whether the validation ranges of the current models can be extended, or whether some or all of the models need to be refit to allow for the incorporation of the SCIX streams. As changes are made to the projected sludge compositions and the volume of the SCIX material, additional evaluations should be performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RHEOLOGY OF SETTLED SOLIDS IN THE SMALL COLUMN ION EXCHANGE PROCESS

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. This process adds monosodium titanate (MST) to a waste tank containing salt solution (and entrained sludge solids). While the process is operating, the solid particles will begin to settle at temperatures up to 45 C. Previous testing has shown that sludge-MST slurries that sit for extended periods (i.e., 1-61 days) at elevated temperatures (i.e., 23-80 C) can develop large shear strengths which could make them difficult to resuspend and remove from the tank. The authors are conducting rheological testing of mixtures containing various concentrations of sludge, MST, and crystalline silicotitanate (CST, ground and unground) that have been aged at different times (i.e., 0 to 13 weeks) and isothermally heated to 30, 45, or 60 C. Additional tests are being conducted that will allow the solid particles to settle at 45 C for 6, 12, and 24 months. The objectives of this task are to determine the impact of settling time and temperature on the shear strength, yield stress, and consistency of the slurries and to determine the impact of radiation on slurry rheology. The testing will determine the relative impact of these parameters rather than predict the shear strength, yield stress, and consistency as a function of feed and operating conditions. This document describes the rheology of slurries containing MST and simulated sludge that sat at elevated temperatures (i.e., up to 60 C) for up to 13 weeks. Rheology of CST-containing slurries, as well as results of the long term settling (6, 12, and 24 months) and irradiation tests (10 and 100 MRad), will be reported later. The conclusions from this analysis follow: (1) MST only slurries that sat at elevated temperatures had larger shear strength, yield stress, and consistency than MST plus sludge slurries that settled at elevated temperatures. (2) The addition of sludge to an MST slurry reduces the shear strength, yield stress, and consistency. (3) The impact of settling time and temperature on slurry rheology is inconclusive at this time. The authors are collecting additional data to attempt to determine the impact of settling time and temperature on slurry shear strength, yield stress, and consistency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STRONTIUM AND ACTINIDE SORPTION BY MST AND MMST UNDER CONDITIONS REVELANT TO THE SMALL COLUMN ION-EXCHANGE PROCESS

A series of tests were performed to examine the kinetics of Sr and actinide removal by monosodium titanate (MST) and modified monosodium titanate (mMST) under mixing conditions similar to what will be provided in the Small Column Ion Exchange (SCIX) Program. Similar removal kinetics were seen for two different mixing energies, indicating that under these conditions bulk solution transport is not the rate limiting step for Sr and actinide removal. Sr removal was found to be rapid for both MST and mMST, reaching steady-state conditions within six hours. In contrast, at least six weeks is necessary to reach steady-state conditions for Pu with MST. For mMST, steady-state conditions for Pu were achieved within two weeks. The actual contact time required for the SCIX process will depend on starting sorbate concentrations as well as the requirements for the decontaminated salt solution. During testing leaks occurred in both the MST and mMST tests and evidence of potential desorption was observed. The desorption likely occurred as a result of the change in solids to liquid phase ratio that occurred due to the loss of solution. Based on these results, Savannah River National Laboratory (SRNL) recommended additional testing to further study the effect of changing phase ratios on desorption. This testing is currently in progress and results will be documented in a separate report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT08, KT09, AND KT10-SERIES GLASS COMPOSITIONS

This report is the fourth in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. MST from the Salt Waste Processing Facility (SWPF) is also considered in the study. The KT08-series of glasses was designed to evaluate any impacts of the inclusion of uranium and thorium in glasses containing the SCIX components. The KT09-series of glasses was designed to study the effect of increasing Al{sub 2}O{sub 3} and K{sub 2}O concentrations on the propensity for crystallization of titanium containing phases in high TiO{sub 2} concentration glasses. Earlier work on the KT05-series glasses recommended that the impact of these two components be studied further. Increased Al{sub 2}O{sub 3} concentrations have been shown to improve the properties and performance of high waste loading glasses, and K{sub 2}O has been reported to improve the retention of TiO{sub 2} in silicate glasses. The KT10-series of compositions was designed to evaluate any impacts of the SCIX components at concentrations 50% higher than currently projected.a The glasses were fabricated in the laboratory and characterized to identify crystallization, to verify chemical compositions, to measure viscosity, and to measure durability. Liquidus temperature measurements for the KT10-series glasses are underway and will be reported separately. All but one of the KT08-series glasses were found to be amorphous by X-ray diffraction (XRD). One of the slowly cooled glasses contained a small amount of trevorite, which had no practical impact on the durability of the glass and is typically found in DWPF-type glasses. The measured Product Consistency Test (PCT) responses for the KT08-series glasses are well predicted by the DWPF models. The viscosities of the KT08-series glasses were generally well predicted by the DWPF model. No unexpected issues were encountered when uranium and thorium were added to the glasses with SCIX components. Increased Al{sub 2}O{sub 3} concentrations were not successful in preventing the formation of iron titanate crystals in the KT09-series glasses. Increased K{sub 2}O concentrations were successful in hindering the formation of iron titanates in some of the glasses after the canister centerline cooled (CCC) heat treatment. However, this result did not apply to all of the CCC versions of the glasses, indicating a compositional dependence of this effect. In addition, high concentrations of K{sub 2}O have been shown to hinder the ability of the DWPF durability and viscosity models to predict the performance of these glasses. The usefulness of increased K{sub 2}O concentrations in preventing the formation of iron titanates may therefore be limited. Further characterization was not performed for the KT09-series glasses since the type of crystallization formed was the characteristic of interest for these compositions. All of the KT10-series glasses were XRD amorphous, regardless of heat treatment. Chemical composition measurements showed that the glasses met the targeted concentrations for each oxide. In general, the measured PCT responses of the KT10-series glasses were well predicted by the DWPF models. The measured, normalized release values for silicon for some of the glasses fell above the 95% confidence interval for the predicted values; however, the PCT responses for these glasses remain considerably lower than that of the benchmark Environmental Assessment (EA) glass. The viscosities of the KT10-series glasses were generally well predicted by the DWPF model. The next step in this study will be to compile all of the data developed and further compare the measured properties and performance with those predicted by the current DWPF Product Composition Control System (PCCS) models. Recommendations will then be made as to which models, if any, may need to be modified in order to accommodate the material from SCIX into DWPF glass production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACT OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION MELT RATE STUDIES

This study was undertaken to evaluate the potential impacts of the Small Column Ion Exchange (SCIX) streams - particularly the addition of Monosodium Titanate (MST) and Crystalline Silicotitanate (CST) - on the melt rate of simulated feed for the Defense Waste Processing Facility (DWPF). Additional MST was added to account for contributions from the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) Melt Rate Furnace (MRF) was used to evaluate four melter feed compositions: two with simulated SCIX and SWPF material and two without. The Slurry-fed Melt Rate Furnace (SMRF) was then used to compare two different feeds: one with and one without bounding concentrations of simulated SCIX and SWPF material. Analyses of the melter feed materials confirmed that they met their targeted compositions. Four feeds were tested in triplicate in the MRF. The linear melt rates were determined by using X-ray computed tomography to measure the height of the glass formed along the bottom of the beakers. The addition of the SCIX and SWPF material reduced the average measured melt rate by about 10% in MRF testing, although there was significant scatter in the data. Two feeds were tested in the SMRF. It was noted that the ground CST alone (ground CST with liquid in a bucket) was extremely difficult to resuspend during preparation of the feed with material from SCIX and SWPF. This feed was also more difficult to pump than the material without MST and CST due to settling occurring in the melter feed line, although the yield stress of both feeds was high relative to the DWPF design basis. Steady state feeding conditions were maintained for about five hours for each feed. There was a reduction in the feed and pour rates of approximately 15% when CST and MST were added to the feed, although there was significant scatter in the data. Analysis of samples collected from the SMRF pour stream showed that the composition of the glass changed as expected when MST and CST were added to the feed. These reductions in melt rate are consistent with previous studies that showed a negative impact of increased TiO{sub 2} concentrations on the rate of melting. The impact of agitating the melt pool via bubbling was not studied as part of this work, but may be of interest for further testing. It is recommended that additional melt rate testing be performed should a potential reduction in melt rate of 10-15% be considered an issue of concern, or should the anticipated composition of the glass with the addition of material from salt waste processing be modified significantly from the current projections, either due to changes in sludge batch preparation or changes in the composition or volume of SCIX and SWPF material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SUMMARY REPORT ON POTENTIAL IMPACTS OF SMALL COLUMN ION EXCHANGE ON DWPF GLASS FORMULATION

This report summarizes a large amount of experimental work completed to identify the potential impacts of material from Small Column Ion Exchange (SCIX) on glass formulation at the Defense Waste Processing Facility (DWPF). The results show no significant issues with the predicted values of chemical durability and viscosity using the current Product Composition Control System (PCCS) models when the SCIX components are added to projected DWPF glass compositions. No modifications to the viscosity and durability models appear to be necessary at this time in order to incorporate the SCIX streams at DWPF. It is recommended that the Savannah River National Laboratory (SRNL) continue to verify the durability and viscosity models as the projected compositions for DWPF processing evolve. It is also recommended that the data generated thus far be reviewed and a determination be made as to how best to extend the validation ranges of the durability and viscosity models. The liquidus temperatures for the experimental glasses are also reported and discussed in this report. The results show that the measured or estimated (based on measured data) liquidus temperature values for the glasses with SCIX components added are consistently higher than those predicted by the current model. Therefore, the PCCS liquidus temperature model will need to be modified in order to incorporate the SCIX streams at DWPF. It is recommended that SRNL carry out full measurements of the liquidus temperatures for those KT-series glasses where estimates have been made. These data should then be used to support an evaluation of whether a refitting of the liquidus temperature model coefficients will be sufficient to correctly predict the liquidus temperature of glasses containing the SCIX components (particularly higher TiO{sub 2} concentrations), or whether additional modifications to the model are required. While there are prediction issues with the current liquidus temperature model, they are not at this time expected to hamper the incorporation of SCIX streams at DWPF. The estimated liquidus temperatures, while higher than the model predicted values, remain below the current DWPF limit of 1050 C for most of the study glasses. Note that the properties and performance of the glasses in this study are highly dependent on glass composition. Therefore, should significant changes be made to the projected compositions or processing rates for SCIX or DWPF, many of the assessments and experiments may have to be revisited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROTARY FILTER FINES TESTING FOR SMALL COLUMN ION EXCHANGE

SRNL was requested to quantify the amount of 'fines passage' through the 0.5 micron membranes currently used for the rotary microfilter (RMF). Testing was also completed to determine if there is any additional benefit to utilizing a 0.1 micron filter to reduce the amount of fines that could pass through the filter. Quantifying of the amount of fines that passed through the two sets of membranes that were tested was accomplished by analyzing the filtrate by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) for titanium. Even with preparations to isolate the titanium, all samples returned results of less than the instrument's detection limit of 0.184 mg/L. Test results show that the 0.5 micron filters produced a significantly higher flux while showing a negligible difference in filtrate clarity measured by turbidity. The first targeted deployment of the RMF is with the Small Column Ion Exchange (SCIX) at the Savannah River Site (SRS). SCIX uses crystalline silicotitanate (CST) to sorb cesium to decontaminate a clarified salt solution. The passage of fine particles through the filter membranes in sufficient quantities has the potential to impact the downstream facilities. To determine the amount of fines passage, a contract was established with SpinTek Filtration to operate a 3-disk pilot scale unit with prototypic filter disk and various feeds and two different filter disk membranes. SpinTek evaluated a set of the baseline 0.5 micron filter disks as well as a set of 0.1 micron filter disks to determine the amount of fine particles that would pass the membrane and to determine the flux each set produced. The membrane on both disk sets is manufactured by the Pall Corporation (PMM 050). Each set of disks was run with three feed combinations: prototypically ground CST, CST plus monosodium titanate (MST), and CST, MST, plus Sludge Batch 6 (SB6) simulant. Throughout the testing, samples of the filtrate were collected, measured for turbidity, and sent back to SRNL for analysis to quantify the amount of fines that passed through the membrane. It should be noted that even though ground CST was tested, it will be transferred to the Defense Waste Processing Facility (DWPF) feed tank and is not expected to require filtration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗