Search NASA⌕ Search

SEARCH · Search NASA

Results for “control systems control system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Approach to Quality Assurance for Complex Environmental Modeling - 20407

A strong Quality Assurance (QA) program for complex environmental modeling is essential for regulatory and public acceptance and trust, but it does not have to be onerous. Neptune and Company, Inc. (Neptune) has developed a strong QA program that improves transparency, traceability, reproducibility, and therefore, defensibility and trust. Neptune's QA program has evolved over the past 27 years, transitioning from an ad hoc QA program, to a program that is currently Nuclear Quality Assurance-1 (NQA-1) compliant, and will soon be NQA-1/DOE approved for DOE EM modeling work. In addition, Neptune is a qualified laboratory assessor and qualified auditor for reference materials, a proficiency testing provider, and fully complies with the Environmental Protection Agency (EPA) QA program. Neptune's President and CEO, Kelly Black, was recently named the Chairperson of the International Organization for Standardization (ISO) Technical Committee 69, Application of Statistical Methods. A strong QA program has been developed for Neptune's radiological performance assessment (PA) program. Although pieces of their QA program are currently in development, their current program includes document control using Subversion, issue tracking and work flow tracking using JIRA, and transparency and traceability via a system of 'calc sheets' for documentation of all data analysis and modeling combined with 'check print' documentation of QA checking, and rigorous model testing and configuration control. All work is reviewed by an independent subject matter expert who is not associated with the collection and assembly of information, for an internal peer review. The program is enforced with a handful of Standard Operation Procedures (SOPs), Work Instructions, QA Project Plans (QAPPs), and Quality Management Plans (QMPs) that are updated frequently, with required annual training and acknowledgment. In addition, effective communication of modeling approaches and results to clients and stakeholders are integral to their QA program. Many of their models are built using the GoldSim modeling platform, for which their models are well-known for their level of transparency, documentation, and QA traceability. This level of QA is also applied to their process-level models. Neptune has taken some lessons learned from the extremely rigorous QA program required for the Yucca Mountain Project (YMP), and imposed the YMP requirements of complete traceability, transparency, and reproducibility, but avoided the inflexibility of a QA program that likely contributed to the suspect e-mails in 2005 that resulted in loss of trust in the YMP, and in nuclear waste disposal (and nuclear power) in general. There are far too many examples of loss of public trust due to poor QA that could have been easily avoided with a simple and straight-forward QA program combined with stakeholder engagement. The purpose of this paper is to share features of Neptune's Radiological Performance Assessment program QA program, and some of their QA related lessons learned over the past 27 years of QA for complex environmental modeling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RNA Splicing Events in Circulation Distinguish Individuals With and Without New-onset Type 1 Diabetes

Context: Alterations in RNA splicing may influence protein isoform diversity that contributes to or reflects the pathophysiology of certain diseases. Whereas specific RNA splicing events in pancreatic islets have been investigated in models of inflammation in vitro, how RNA splicing in the circulation correlates with or is reflective of type 1 diabetes (T1D) disease pathophysiology in humans remains unexplored. Objective: To use machine learning to investigate if alternative RNA splicing events differ between individuals with and without new-onset T1D and to determine if these splicing events provide insight into T1D pathophysiology. Methods: RNA deep sequencing was performed on whole blood samples from 2 independent cohorts: a training cohort consisting of 12 individuals with new-onset T1D and 12 age- and sex-matched nondiabetic controls and a validation cohort of the same size and demographics. Machine learning analysis was used to identify specific isoforms that could distinguish individuals with T1D from controls. Results: Distinct patterns of RNA splicing differentiated participants with T1D from unaffected controls. Notably, certain splicing events, particularly involving retained introns, showed significant association with T1D. Machine learning analysis using these splicing events as features from the training cohort demonstrated high accuracy in distinguishing between T1D subjects and controls in the validation cohort. Gene Ontology pathway enrichment analysis of the retained intron category showed evidence for a systemic viral response in T1D subjects. Conclusion: Alternative RNA splicing events in whole blood are significantly enriched in individuals with new-onset T1D and can effectively distinguish these individuals from unaffected controls. Further, our findings also suggest that RNA splicing profiles offer the potential to provide insights into disease pathogenesis.

60 APPLIED LIFE SCIENCES↗

Metagenomic Analysis of Three Samples from the MCU Process

Three Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) Strip Effluent Feed samples were sent from Savannah River National Laboratory (SRNL) to Microbial Insights (MI), Knoxville, TN, for molecular analysis. The objective of the analysis was to profile and identify dominant members of the microbial community in these samples. More effective control of microbial growth in the MCU depends on the fundamental understanding of the microorganisms responsible for system colonization that leads to biofilm formation and coalescer impairment. This analysis entailed Next-generation sequencing (NGS) of DNA, a collective term for advanced technologies that allow the determination of microbial species present. NGS, also commonly called metagenomics, provides for the identification of microorganisms down to the genus level. Although function, e.g. biofilm formation or corrosion, cannot always be predicted from identification, knowledge of the microorganisms present can offer insight into the potential microbial processes that may influence system function occurring in the MCU. Information on microbial identification can also influence control measures, e.g. operational/maintenance parameters or the choice of biocides to employ. This knowledge can help control undesired microbial activity as conventional cleaning and disinfection regimens may also contribute to inefficient biofilm control and dissemination of microbial resistance to remediation efforts.

59 BASIC BIOLOGICAL SCIENCES↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

XMCD experimental station optimized for ultrathin magnetic films at HiSOR-BL14

We have constructed a system for in situ X-ray magnetic circular dichroism (XMCD) measurements of ultrathin magnetic films at the soft X-ray beamline HiSOR-BL14 at Hiroshima Synchrotron Radiation Center. The XMCD experimental station is directly connected to the beamline, and equipped with a sample fabrication chamber where various types of ultrathin magnetic films can be grown with monatomic layer control. XMCD spectra of the as-grown samples can be measured with adequate precision for the analysis of magnetic moments, under proper control of the light polarization in the beamline optics. This system has enabled the investigation of natural magnetic states in the ultrathin magnetic films without the influence of surface oxidation or any cap-layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparative Analysis of Infrastructure-Based Perception Sensors for Intelligent Transportation Systems

The rise of privatized and public investment in smart city infrastructure and intelligent transportation systems has generated a heightened demand for perception sensors that effectively track and detect objects while being reliable in diverse weather and lighting conditions. This growing demand for perception sensors has accelerated their development and enhanced their capabilities. With these new capabilities, it is challenging to determine the most suitable sensing unit to use in each situation. Therefore, it is essential to have a comprehensive understanding of the benefits and limitations of each sensing unit to effectively leverage their capabilities. The purpose of this paper is to provide a detailed evaluation of various perception sensors. Additionally, this paper will demonstrate the benefits of combining multiple perception sensors, which complement each other by addressing data gaps inherent to single-sensor systems, to facilitate the creation of a digital twin that models the real world. The Infrastructure, Perception, and Control (IPC) team will conduct data analysis using data collected through field testing at traffic intersections in Colorado Springs, Colorado, to make comparisons between sensors. This research aims to provide clear and concise information about modern perception systems, which will support the development of intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

Final report : impacts analysis for cyber attack on electric power systems (National SCADA Test Bed FY08).

To analyze the risks due to cyber attack against control systems used in the United States electrical infrastructure, new algorithms are needed to determine the possible impacts. This research is studying the Reliability Impact of Cyber ttack (RICA) in a two-pronged approach. First, malevolent cyber actions are analyzed in terms of reduced grid reliability. Second, power system impacts are investigated using an abstraction of the grid's dynamic model. This second year of esearch extends the work done during the first year.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Efficient Sampling-Based Method for Sensitivity and Uncertainty Analysis Through RAVEN

Sensitivity analysis (SA) and uncertainty quantification (UQ) are now widely recognized as essential parts of analyses for complex nuclear systems. Plenty of well-established methodologies are already available for performing SA and UQ, such as Monte Carlo analysis, adjoint-based method, and variance decomposition. The focus of this summary is on developing an efficient sampling-based approach to perform SA and UQ through RAVEN. RAVEN (Risk Analysis and Virtual control Environment) is a software framework able to perform SA and UQ, currently under development at the Idaho National Laboratory. In literature, a number of approaches have been developed to accelerate the process of SA and UQ for large complex systems, such as principal component analysis (PCA) of input space, input-output correlation analysis, and intersection subspace methods. The fundamental idea is to identify the dominant active directions in the parameter space prior to conducting SA and UQ. The premise is that the number of active directions is much less than the dimensionality of input space. In this work, the PCA or Karhunen-Loeve expansion or SVD method is implemented in RAVEN to identify the active directions. This approach is also combined with the forward sampling approaches, such as Monte Carlo, Grid, Latin Hypercube, and Response Surface Design sampling approaches that are currently available in RAVEN, to perform SA and UQ more efficiently. The summary is organized as follows. In the following section, we present the PCA-based forward sampling approach. The effectiveness and efficiency are discussed in the numerical results section. The paper then ends with a concluding summary. In this summary, we have presented PCA-based forward sampling approach to perform SA and UQ. The goal is to reduce the computational overhead for repetitive executions of complex nuclear systems that are generally required when performing SA and UQ. The control of correlations between input parameters is implemented in RAVEN to better represent the input relationships. In addition, we are currently examining our implementations with more realistic models, and we are also focusing on implementation of some new high-dimensional input reduction techniques in RAVEN. (authors)

97 MATHEMATICS AND COMPUTING↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Load Mitigation on Floating Offshore Wind Turbines with Advanced Controls and Tuned Mass Dampers

General Electric, the National Renewable Energy Laboratory (NREL), the University of Massachusetts Amherst (UMass), and Glosten have recently completed a US Department of Energy (DOE)-funded research program to study technologies for mitigating loads on floating offshore wind turbines through the use of advanced turbine controls and tuned mass dampers (TMDs). The analysis was based upon the Glosten PelaStar tension leg platform (TLP) with GE Haliade 150 turbine, a system developed in a previous front end engineering design (FEED) study funded by the Energy Technology Institute (ETI) in the UK. The platform was designed for the WaveHub wave energy research site, with a mean water depth of 59-m. Loads were analyzed by running time-domain simulations in four 50-year return period (50-YRP) ultimate load state (ULS) conditions and 77 fatigue load state (FLS) environmental conditions. In 50-YRP conditions advanced controls are not active. The influence of TMDs on ULS loads have been reported previously (Park et al. [2]). In FLS conditions advanced controls and TMDs afford dramatic reductions in fatigue damage, offering the potential of significant savings in tower structural requirements. Simulations in turbine idling conditions were run in OrcaFlex, and simulations in operating conditions were run in FAST. Simulations were run with a baseline turbine controller, representative of the current state of the art, and an advanced controller developed by NREL to use collective and individual blade pitch control to maintain rotor speed and reduce tower loads. UMass developed a number of TMD types, with varying system configurations, including passive nonlinear dampers and semi-actively controlled dampers with an inverse velocity groundhook control algorithm. Loads and accelerations in FLS conditions were evaluated on the basis of damage equivalent loads (DELs), and fatigue damage was computed by Miner's summations of stress cycles at the tower base. To study sensitivity to water depth, loads were analyzed at both the 59-m WaveHub depth and a more commercially realistic depth of 100 m. TMDs reduce fatigue damage at the tower-column interface flange by up to 52% in 59-m water depth and up to 28% in 100 m water depth. Advanced controls reduce fatigue damage at the tower-column flange by up to 22% in 59-m water depth and up to 40% in 100 m water depth. The most effective load-mitigation strategy is combining advanced controls with TMDs. This strategy affords a 71% reduction in fatigue damage in both 59-m and 100-m water depths.

17 WIND ENERGY↗

OPTIMAL CONTROL AND ENERGY-SAVING ANALYSIS OF COMMON PRESSURE RAIL ARCHITECTURES: HHEA & STEAM

In recent years several novel hydraulic architectures have been proposed with the intention of significantly increasing system efficiency. Two of these architectures, Steigerung der Energieeffizienz in der Arbeitshydraulik mobiler Arbeitsmaschinen (STEAM), and the Hybrid Hydraulic-Electric Architecture (HHEA), use a system of multiple common pressure rails (CPRs) to serve the multiple degrees-of-freedom of the machine. The key difference is that STEAM throttles hydraulic power from these rails while HHEA combines electric and hydraulic power to meet actuator demands. As a throttle-less architecture, HHEA is expected to save more energy than STEAM at the expense of added complexity. Therefore, it is useful to quantify this additional energy saving. Both systems have discrete operational choices corresponding to how the CPRs are utilized for each actuator. It is necessary to determine optimal operation for each of these architectures for analysis and fair comparison. Techniques for optimal operation of the HHEA have been developed previously from the Langrange multiplier method. Applying the same optimal control method to STEAM encountered some technical challenge leading to the optimal control algorithm not being able to satisfy certain constraints. The issue is analyzed and solved by adding noise to the optimization. Using this proposed algorithm, case studies are performed to compare the energy-saving potentials of STEAM and HHEA for two sizes of excavators and a wheel-loader performing representative duty cycles. The baseline is a standard load-sensing architecture. Results show that STEAM and HHEA can reduce energy consumption between 35-65% and 50-80% respectively

24 POWER TRANSMISSION AND DISTRIBUTION↗

Saturn Facility Oil Transfer Automation System

The Saturn accelerator, owned by Sandia National Laboratories, has been in operation since the early 1980s and still has many of the original systems. A critical legacy system is the oil transfer system which transfers 250,000 gallons of transformer oil from outside storage tanks to the Saturn facility. The oil transfer system was identified for upgrade to current technology standards. Using the existing valves, pumps, and relay controls, the system was automated using the National Instruments cRIO FGPA platform. Engineered safety practices, including a failure mode effects analysis, were used to develop error handling requirements. The uniqueness of the Saturn Oil Automated Transfer System (SOATS) is in the graphical user interface. The SOATS uses an HTML interface to communicate to the cRIO, creating a platform independent control system. The SOATS was commissioned in April 2013.

02 PETROLEUM↗

Grid-scale Energy Storage Hazard Analysis & Design Objectives for System Safety

Battery based energy storage systems are becoming a critical part of a modernized, resilient power system. However, batteries have a unique combination of hazards that can make design and engineering of battery systems difficult. This report presents a systematic hazard analysis of a hypothetical, grid scale lithium-ion battery powerplant to produce sociotechnical "design objectives" for system safety. We applied system's theoretic process analysis (STPA) for the hazard analysis which is broken into four steps: purpose definition, modeling the safety control structure, identifying unsafe control actions, and identifying loss scenarios. The purpose of the analysis was defined as to prevent event outcomes that can result in loss of battery assets due to fires and explosions, loss of health or life due to battery fires and explosions, and loss of energy storage services due to non- operational battery assets. The STPA analysis resulted in identification of six loss scenarios, and their constituent unsafe control actions, which were used to define a series of design objectives that can be applied to reduce the likelihood and severity of thermal events in battery systems. These design objectives, in all or any subset, can be utilized by utilities and other industry stakeholders as "design requirements" in their storage request for proposals (RFPs) and for evaluation of proposals. Further, these design objectives can help to protect firefighters and bring a system back to full functionality after a thermal event. We also comment on the hazards of flow battery technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis to Inform CA Grid Integration Rules for PV: Final Report on Inverter Settings for Transmission and Distribution System Performance

The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547 Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.

14 SOLAR ENERGY↗

Process systematic research initiatives on decommissioning of nuclear power plants - 15493

This paper considers how process systems engineering (PSE) principles can be employed in the process of decommissioning and decontamination of nuclear power plants. PSE has been associated with design, operation, control, and optimization of chemical and physical processes. It has been shown to be very powerful in the context of analysis, synthesis, and evaluation of chemical and petrochemical industries. This paper aims to identify the research opportunity in employing the PSE principles in the decommissioning of nuclear power plants in order to minimize their cost and time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Department of Energy/IDEA: More best-practices research

This article continues the overview of the U.S. Department of Energy and IDEA collaboration by highlighting additional case studies that demonstrate innovative engineering approaches in district energy systems. It focuses on how campuses are improving efficiency, integrating advanced technologies, and reducing energy use and emissions through data-driven strategies. The University of Cincinnati is featured for its highly efficient chilled water system, using advanced algorithms and upgraded “smart chillers” to optimize performance, reduce energy consumption, and lower costs. Wake Forest University emphasizes a data-informed modernization process, using system optimization and targeted building improvements to significantly boost efficiency and reduce overall energy use. Arizona Western College showcases creative solutions to extreme cooling demands, including system redesign, smart controls, and thermal storage to improve reliability and cut peak energy costs. Overall, the article demonstrates that combining innovative engineering, real-time data analysis, and system optimization can significantly enhance performance, reduce emissions, and deliver cost savings in district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building.The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference.Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five isomers of the PFT PDCH (mtPDCH, pcPDCH, otPDCH, mcPDCH, and ptPDCH). These isomers were quantified in the low concentration samples in the Alpha test and in all samples in the Bravo test.The best estimates of UI (Rui) for the four zones are provided in Table ES-1. For the CB, this estimate averages the four tracers at the four elevations. For the CR, this estimate uses the four sampling units located in the Control Room.

54 ENVIRONMENTAL SCIENCES↗