Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Dose-Volume Parameters Predict for the Development of Chest Wall Pain After Stereotactic Body Radiation for Lung Cancer

Purpose: Chest wall (CW) pain has recently been recognized as an important adverse effect of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). We developed a dose-volume model to predict the development of this toxicity. Methods and Materials: A total of 126 patients with primary, clinically node-negative NSCLC received three to five fractions of SBRT to doses of 40-60 Gy and were prospectively followed. The dose-absolute volume histograms of two different definitions of the CW as an organ at risk (CW3cm and CW2cm) were examined for all 126 patients. Results: With a median follow-up of 16 months, the 2-year estimated actuarial incidence of Grade {>=} 2 CW pain was 39%. The median time to onset of Grade {>=} 2 CW pain (National Cancer Institute Common Terminology Criteria for Adverse Events, Version 3.0) was 9 months. There was no predictive advantage for biologically corrected dose over physical dose. Neither fraction number (p = 0.07) nor prescription dose (p = 0.07) were significantly correlated with the development of Grade {>=} 2 CW pain. Cox Proportional Hazards analysis identified significant correlation with a broad range of dose-volume combinations, with the CW volume receiving 30 Gy (V30) as one of the strongest predictors (p < 0.001). CW2cm consistently enabled better prediction of CW toxicity. When a physical dose of 30 Gy was received by more than 70 cm{sup 3} of CW2cm, there was a significant correlation with Grade {>=} 2 CW pain (p = 0.004). Conclusions: CW toxicity after SBRT is common and long-term follow-up is needed to identify affected patients. A volume of CW {>=} 70 cm{sup 3} receiving 30 Gy is significantly correlated with Grade {>=} 2 CW pain. We are currently applying this constraint at our institution for patients receiving thoracic SBRT. An actuarial atlas of our data is provided as an electronic supplement to facilitate data-sharing and meta-analysis relating to CW pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EXPLORING THE CORRELATIONS BETWEEN GLOBULAR CLUSTER POPULATIONS AND SUPERMASSIVE BLACK HOLES IN GIANT GALAXIES

This paper presents an analysis of the correlation between the number of globular clusters (N{sub GC}) in giant galaxies and the mass of the galaxies' central supermassive black hole (M{sub SMBH}). I construct a sample of 20 elliptical, spiral, and S0 galaxies with known SMBH masses and with accurately measured GC system properties derived from wide-field imaging studies. The coefficients of the best-fitting N{sub GC}-M{sub SMBH} relation for the early-type galaxies are consistent with those from previous work but in some cases have smaller relative errors. I examine the correlation between N{sub GC} and M{sub SMBH} for various subsamples and find that elliptical galaxies show the strongest correlation, while S0 and pseudobulge galaxies exhibit increased scatter. I also compare the quality of the fit of the numbers of metal-poor GCs versus SMBH mass and the corresponding fit for metal-rich GCs. I supplement the 20 galaxy sample with 10 additional galaxies with reliable N{sub GC} determinations but without measured M{sub SMBH}. I use this larger sample to investigate correlations between N{sub GC} and host galaxy properties like total galaxy luminosity and stellar mass, and bulge luminosity and mass. I find that the tightest correlation is between N{sub GC} and total galaxy stellar mass. This lends support to the notion that N{sub GC} and M{sub SMBH} are not directly linked but are correlated because both quantities depend on the host galaxy potential. Finally, I use the N{sub GC}-M{sub SMBH} relation derived from the 20 galaxy sample to calculate predicted M{sub SMBH} values for the 10 galaxies with accurate N{sub GC} measurements but without measured SMBH masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning-Based Investigation of the Associations between Residential Power Consumption and Weather Conditions

Machine learning feature selection analyses were conducted to understand the impact of various weather attributes on power electricity demand and its components in the northwest United States. Load profiles data were obtained from the Northwest Energy Efficiency Alliance (NEEA) and processed to yield hourly load profiles with the same temporal resolution as the weather conditions data obtained from the National Oceanic and Atmospheric Administration (NOAA) for representative weather stations. The data were divided into five seasons; for each season, for each load component, the influences of weather factors were evaluated and quantified using cross-correlation, principal component analysis, and mutual information evaluation; then predictive models were developed based on the ranked/screened factors using the regression tree (RT) approach. After multi-fold cross-validation, the optimal complexity/depth of the regress tree models is found to vary for different load components, and the prediction accuracy using RT and weather data can be higher than 80% for heating and refrigeration, or lower than 30% for vent and cooking. The study provides guidance on improvement of load profile generation, or even serves as a standalone predictive tool for approximating load profiles in balance authorities or climate zones where load profile data is absent.

load composite, load profiling, NEEA, mutual infor↗

Spin-correlation coefficients and phase-shift analysis for p+{sup 3}He elastic scattering

Angular distributions for the target spin-dependent observables A{sub 0y}, A{sub xx}, and A{sub yy} have been measured using polarized proton beams at several energies between 2 and 6 MeV and a spin-exchange optical pumping polarized {sup 3}He target. These measurements have been included in a global phase-shift analysis following that of E. A. George and L. D. Knutson [Phys. Rev. C 67, 027001 (2003)], who reported two best-fit phase-shift solutions to the previous global p+{sup 3}He elastic-scattering database below 12 MeV. These new measurements, along with measurements of cross-section and beam-analyzing power made over a similar energy range by B. M. Fisher et al. [Phys. Rev. C 74, 034001 (2006)], allowed a single, unique solution to be obtained. The new measurements and phase shifts are compared with theoretical calculations using realistic nucleon-nucleon potential models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Outstanding radiation resistance of tungsten-based high-entropy alloys

A body-centered cubic W-based refractory high entropy alloy with outstanding radiation resistance has been developed. The alloy was grown as thin films showing a bimodal grain size distribution in the nanocrystalline and ultrafine regimes and a unique 4-nm lamella-like structure revealed by atom probe tomography (APT). Transmission electron microscopy (TEM) and x-ray diffraction show certain black spots appearing after thermal annealing at elevated temperatures. TEM and APT analysis correlated the black spots with second-phase particles rich in Cr and V. No sign of irradiation-created dislocation loops, even after 8 dpa, was observed. Furthermore, nanomechanical testing shows a large hardness of 14 GPa in the as-deposited samples, with near negligible irradiation hardening. Theoretical modeling combining ab initio and Monte Carlo techniques predicts the formation of Cr- and V-rich second-phase particles and points at equal mobilities of point defects as the origin of the exceptional radiation tolerance.

36 MATERIALS SCIENCE↗

Lower molar shape and size in prosimian and platyrrhine primates

Abstract The goal of this research is to evaluate the relative strength of the influences of diet, size, and phylogenetic signal on dental geometric shape. Accurate comprehension of these factors and their interaction is important for reconstructing diet and deriving characters for a cladistic analysis in fossil primates. Geometric morphometric analysis is used to identify axes of shape variation in the lower second molars of (a) prosimian primates and (b) platyrrhines. Landmarks were placed on µCT‐generated surface renderings. Landmark configurations were aligned using generalized Procrustes analysis. Principal components analysis and phylogenetic principal components analysis (pPCA) were performed on species average landmark co‐ordinates. pPCs were examined with phylogenetic generalized least squares analysis for association with size and with diet. PCs from both phylogenetic and non‐phylogenetic analyses were sufficient to separate species by broad dietary categories, including insectivores and folivores. In neither analysis was pPC1 correlated with tooth size, but some other pPCs were significantly correlated with size. The pattern of association between pPCs and size altered when centroid size and dietary variables were combined in the model; effects of diet factors typically exceeded effects of size. These results indicate a dominant phylogenetic and dietary signal in molar shape but also show some shape change correlated with size in the absence of obvious dietary associations. Geometric morphometric analysis appears to be useful for tracking functional traits in molars, particularly in tracking differences between folivorous and insectivorous species.

St. Clair, Elizabeth M.↗

Network analysis of earthquake ground motion spatial correlation: a case study with the San Jacinto seismic nodal array

SUMMARY The spatial correlation of earthquake ground motion intensity can be measured from strong motion data; however, the data used in past studies is sparsely sampled in space, and only the interstation distance was considered as a correlation variable. These limitations mean that we have only weak constraints on the true correlation structure of ground motion and that potentially important aspects of spatial correlation are unconstrained. In this study, we combine a large-N seismic array and graph analytics to explore this issue at a local scale using small local and regional earthquakes. Our result suggests site conditions, and how they interact with the incident seismic wavefield, strongly condition the spatial correlation of ground motion. Future progress in characterizing ground motion spatial variability will require dense wavefield measurements, either through nodal deployments, or perhaps distributed acoustic sensing measurements, of seismic wavefields. Aftershock sequences of major earthquakes would provide particularly data-rich targets of opportunity.

58 GEOSCIENCES↗

Design and analysis of machine learning exchange-correlation functionals via rotationally invariant convolutional descriptors

Here, we explore the potential of a data-driven approach to the design of exchange-correlation (xc) functionals. The approach, inspired by convolutional filters in computer vision and surrogate functions from optimization, utilizes convolutions of the electron density to form a feature space to represent local electronic environments and neural networks to map the features to the exchange-correlation energy density. These features are orbital free, and provide a systematic route to including information at various length scales. This work shows that convolutional descriptors are theoretically capable of an exact representation of the electron density, and proposes Maxwell-Cartesian spherical harmonic kernels as a class of rotationally invariant descriptors for the construction of machine learned functionals. The approach is demonstrated using data from the B3LYP functional on a number of small molecules containing C, H, O, and N along with a neural network regression model. The machine learned functionals are compared to standard physical approximations and the accuracy is assessed for the absolute energy of each molecular system as well as formation energies. The results indicate that it is possible to reproduce the exchange-correlation portion of B3LYP formation energies to within chemical accuracy using orbital-free descriptors with a spatial extent of 0.2 Å. The findings provide empirical insight into the spatial range of electron exchange, and suggest that the combination of convolutional descriptors and machine learning regression models is a promising framework for xc functional design, although challenges remain in obtaining training data and generating models consistent with pseudopotentials.

36 MATERIALS SCIENCE↗

SU-E-T-547: A Method to Correlate Treatment Planning Issue with Clinical Analysis for Prostate Stereotactic Body Radiotherapy (SBRT)

Purpose: In this study, the algorithms and calculation setting effect and contribution weighing on prostate Volumetric Modulated Arc Therapy (VMAT) based SBRT were evaluated for clinical analysis. Methods: A low risk prostate patient under SBRT was selected for the treatment planning evaluation. The treatment target was divided into low dose prescription target volume (PTV) and high Dose PTV. Normal tissue constraints include urethra and femur head, and rectum was separated into anterior, lateral and posterior parts. By varying the constraint limit of treatment plan calculation setting and algorithms, the effect on dose coverage and normal tissue dose constraint parameter carried effective comparison for the nominal prescription and constraint. For each setting, their percentage differences to the nominal value were calculated with geometric mean and harmonic mean. Results: In the arbitrary prostate SBRT case, 14 variables were selected for this evaluation by using nominal prescription and constraint. Six VMAT planning settings were anisotropic analytic algorithm stereotactic beam with and without couch structure in grid size of 1mm and 2mm, non stereotactic beam, Acuros algorithm . Their geometry means of the variable sets for these plans were 112.3%, 111.9%, 112.09%, 111.75%, 111.28%, and 112.05%. And the corresponding harmonic means were 2.02%, 2.16%, 3.15%, 4.74%, 5.47% and 5.55%. Conclusions: In this study, the algorithm difference shows relatively larger harmonic mean between prostate SBRT VMAT plans. This study provides a methodology to find sensitive combined variables related to clinical analysis, and similar approach could be applied to the whole treatment procedure from simulation to treatment in radiotherapy for big clinical data analysis.

60 APPLIED LIFE SCIENCES↗

Shockley-Queisser analysis of the temperature-efficiency correlation of solar cells in the presence of non-radiative heat transfer

An empirical negative T cell − η correlation has been widely applied, without careful justifications, to evaluate the efficiency ( η ) increase of solar cells due to their temperature ( T cell ) decrease. Here, a framework is introduced to simultaneously compute T cell and η . This model confirms the negative T cell − η correlation if the above-bandgap absorptivity ( α I ) is not suppressed in the optimization of the sub-bandgap reflectivity ( ρ II ) or the infrared emissivity, otherwise it may suggest a positive correlation. It further gives a guideline to enhance η of silicon cells under typical conditions: every 1% increase of α I is equivalent to a 57% increase of ρ II .

14 SOLAR ENERGY↗

Uncertainty analysis of densities and isotopics: Handling correlations

This paper discusses two cases of correlated parameters in uncertainty analyses: (1) the case of measured mass, density, and volume or spatial dimension correlations; and (2) the case of measured material isotopics, where increasing one atom fraction must cause the others to decrease. In the first case, an equation is derived that has a term due to uncertain density, a term due to uncertain dimensions, and a term due to the correlation between density and dimensions. In a numerical test problem, this equation gives the same result as the standard equation that treats mass and dimensions independently. In the case of isotopics, an equation is derived relating the uncertainty due to uncertain isotopic fractions to the sensitivities to isotopic densities, which are easier to calculate. The equation is verified in a test problem. (authors)

97 MATHEMATICS AND COMPUTING↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction. Conclusions: The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Measurements of the Wake of a Sphere at Subcritical Reynolds Numbers

This work experimentally investigated the flow phenomena and vortex structures in the wake of a sphere located in a water loop at Reynolds numbers of Re = 850, 1,250, and 1,700. Velocity fields in the wake region were obtained by applying the time-resolved stereoscopic particle image velocimetry (TR-SPIV) technique. From the acquired TR-SPIV velocity vector fields, the statistical values of mean and fluctuating velocities were computed. Spectral analysis, two-point velocity–velocity cross-correlation, proper orthogonal decomposition (POD) and vortex identification analyses were also performed. The velocity fields show a recirculation region that decreases in length with an increase of Reynolds numbers. The power spectra from the spectral analysis had peaks corresponding to a Strouhal number of St = 0.2, which is a value commonly found in the literature studies of flow over a sphere. The two-point cross-correlation analysis revealed elliptical structures in the wake, with estimated integral length scales ranging between 12% and 63% of the sphere diameter. The POD analysis revealed the statistically dominant flow structures that captured the most flow kinetic energy. It is seen that the flow kinetic energy captured in the smaller scale flow structures increased as Reynolds number increased. The POD modes contained smaller structure as the Reynolds number increased and as mode order increased. In addition, spectral analysis performed on the POD temporal coefficients revealed peaks corresponding to St = 0.2, similar to the spectral analysis on the fluctuating velocity. The ability of POD to produce low-order reconstructions of the flow was also utilized to facilitate vortex identification analysis, which identified average vortex sizes of 0.41D for Re1, 0.33D for Re2, and 0.32D for Re3.

Engineering↗