Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Machine learning-based multidomain processing for texture-based image segmentation and analysis

Atomic and molecular resolved atomic force microscopy (AFM) images offer unique insights into materials' properties such as local ordering, molecular orientation, and topological defects, which can be used to pinpoint physical and chemical interactions occurring at the surface. Utilizing machine learning for extracting underlying physical parameters increases the throughput of AFM data processing and eliminates inconsistencies intrinsic to manual image analysis, thus enabling the creation of reliable frameworks for qualitative and quantitative evaluation of experimental data. Here, we present a robust and scalable approach to the segmentation of AFM images based on flexible pre-selected classification criteria. The usage of supervised learning and feature extraction allows us to retain the consideration of specific problem-dependent features (such as types of periodical structures observed in the images and the associated numerical parameters: spacing, orientation, etc.). We highlight the applicability of this approach for the segmentation of molecular resolved AFM images based on the crystal orientation of the observed domains, automated selection of boundaries, and collection of relevant statistics. Finally, we outline a general strategy for machine learning-enabled analysis of nanoscale systems exhibiting periodic order that could be applied to any analytical imaging technique

36 MATERIALS SCIENCE↗

Advanced data mining in field ion microscopy

Field ion microscopy (FIM) allows to image individual surface atoms by exploiting the effect of an intense electric field. Widespread use of atomic resolution imaging by FIM has been hampered by a lack of efficient image processing/data extraction tools. Recent advances in imaging and data mining techniques have renewed the interest in using FIM in conjunction with automated detection of atoms and lattice defects for materials characterization. After a brief overview of existing routines, we review the use of machine learning (ML) approaches for data extraction with the aim to catalyze new data-driven insights into high electrical field physics. Apart from exploring various supervised and unsupervised ML algorithms in this context, we also employ advanced image processing routines for data extraction from large sets of FIM images. The outcomes and limitations of such routines are discussed, and we conclude with the possible application of energy minimization schemes to the extracted point clouds as a way of improving the spatial resolution of FIM.

36 MATERIALS SCIENCE↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

What a difference a delay makes! CT urogram: a pictorial essay

Purpose: The aim of this pictorial essay is to demonstrate several cases where the diagnosis would have been difficult or impossible without the excretory phase image of CT urography. Methods: A brief discussion of CT urography technique and dose reduction is followed by several cases illustrating the utility of CT urography. Results: CT urography has become the primary imaging modality for evaluation of hematuria, as well as in the staging and surveillance of urinary tract malignancies. CT urography includes a non-contrast phase and contrast-enhanced nephrographic and excretory (delayed) phases. While the three phases add to the diagnostic ability of CT urography, it also adds potential patient radiation dose. Several techniques including automatic exposure control, iterative reconstruction algorithms, higher noise tolerance, and split-bolus have been successfully used to mitigate dose. The excretory phase is timed such that the excreted contrast opacifies the urinary collecting system and allows for greater detection of filling defects or other abnormalities. Sixteen cases illustrating the utility of excretory phase imaging are reviewed. Conclusions: Excretory phase imaging of CT urography can be an essential tool for detecting and appropriately characterizing urinary tract malignancies, renal papillary and medullary abnormalities, CT radiolucent stones, congenital abnormalities, certain chronic inflammatory conditions, and perinephric collections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative approaches for multiscale structural analysis with atomic resolution electron microscopy

Atomic-resolution imaging with scanning transmission electron microscopy is a powerful tool for characterizing the nanoscale structure of materials, in particular features such as defects, local strains, and symmetry-breaking distortions. In addition to advanced instrumentation, the effectiveness of the technique depends on computational image analysis to extract meaningful features from complex datasets recorded in experiments, which can be complicated by the presence of noise and artifacts, small or overlapping features, and the need to scale analysis over large representative areas. Here, we present image analysis approaches which synergize real and reciprocal space information to efficiently and reliably obtain meaningful structural information with picometer scale precision across hundreds of nanometers of material from atomic-resolution electron microscope images. Damping superstructure peaks in reciprocal space allows symmetry-breaking structural distortions to be disentangled from other sources of inhomogeneity and measured with high precision. Real-space fitting of the wavelike signals resulting from Fourier filtering enables absolute quantification of lattice parameter variations and strain, as well as the uncertainty associated with these measurements. Implementations of these algorithms are made available as an open source python package.

36 MATERIALS SCIENCE↗

Validating Phasing and Geometry of Large Focal Plane Arrays

The Kepler Mission is designed to survey our region of the Milky Way galaxy to discover hundreds of Earth-sized and smaller planets in or near the habitable zone. The Kepler photometer is an array of 42 CCDs (charge-coupled devices) in the focal plane of a 95-cm Schmidt camera onboard the Kepler spacecraft. Each 50x25-mm CCD has 2,200 x 1,024 pixels. The CCDs accumulate photons and are read out every six seconds to prevent saturation. The data is integrated for 30 minutes, and then the pixel data is transferred to onboard storage. The data is subsequently encoded and transmitted to the ground. During End-to-End Information System (EEIS) testing of the Kepler Mission System (KMS), there was a need to verify that the pixels requested by the science team operationally were correctly collected, encoded, compressed, stored, and transmitted by the FS, and subsequently received, decoded, uncompressed, and displayed by the Ground Segment (GS) without the outputs of any CCD modules being flipped, mirrored, or otherwise corrupted during the extensive FS and GS processing. This would normally be done by projecting an image on the focal plane array (FPA), collecting the data in a flight-like way, and making a comparison between the original data and the data reconstructed by the science data system. Projecting a focused image onto the FPA through the telescope would normally involve using a collimator suspended over the telescope opening. There were several problems with this approach: the collimation equipment is elaborate and expensive; as conceived, it could only illuminate a limited section of the FPA (.25 percent) during a given test; the telescope cover would have to be deployed during testing to allow the image to be projected into the telescope; the equipment was bulky and difficult to situate in temperature-controlled environments; and given all the above, test setup, execution, and repeatability were significant concerns. Instead of using this complicated approach of projecting an optical image on the FPA, the Kepler project developed a method using known defect features in the CCDs to verify proper collection and reassembly of the pixels, thereby avoiding the costs and risks of the optical projection approach. The CCDs composing the Kepler FPA, as all CCDs, had minor defects. At ambient temperature, some pixels look far brighter than they should. These ghot h pixels have a higher rate of charge leakage than the others due to manufacturing variations. They are usually stable over time, and appear at temperatures above 5 oC. The hot pixels on the Kepler FPA were mapped before photometer assembly during module testing. Selected hot pixels were used as target gstars h for the purposes of EEIS testing. gDead h pixels are permanently off, producing a permanently black pixel. These can also be used if there is some illumination of the FPA. During EEIS testing, Dark Current Full Frame Images (FFIs) taken at room temperature were used to create the hot pixel maps for all 84 Kepler photometer CCD channels. Data from two separate nights were used to create two hot pixel maps per channel, which were cross-correlated to remove cosmic ray events which appear to be hot pixels. These hot pixel maps obtained during EEIS testing were compared to the maps made during module testing to verify that the end-to-end data flow was correct.

Standley, Shaun P.↗

Nondestructive monitoring damage in composites using scanning laser acoustic microscopy

Several Nicalon fiber reinforced LAS (lithium alumino-silicate) glass matrix composites were tested to study the relation between the residual strength and the different amounts of damage. The samples were fatigued by four-point cyclic loading at a 5 Hz rate at 500 C for a different number of cycles. 10 MHz scanning laser acoustic microscope (SLAM) images were taken to monitor damage on the samples. Our SLAM results indicate that there were defects already existing throughout the sample before fatigue, and the resultant damage pattern from fatigue could be related to the initial defect distribution in the sample. Finally, the fatigued samples were fractured and the residual strength data could not be explained by the cyclic fatigue alone. Rather, the damage patterns evident in the SLAM images were needed to explain the scatter in the data. The results show that SLAM is useful in nondestructively monitoring damage and estimating residual strength of fatigued ceramic composites.

Wey, A. C.↗

Nondestructive Evaluation of Foam Insulation for the External Tank Return to Flight

Nondestructive evaluation methods have been developed to identify defects in the foam thermal protection system (TPS) of the Space Shuttle External Tank (ET). Terahertz imaging and backscatter radiography have been brought from prototype lab systems to production hardened inspection tools in just a few years. These methods have been demonstrated to be capable of detecting void type defects under many inches of foam which, if not repaired, could lead to detrimental foam loss. The evolution of these methods from lab tools to implementation on the ET will be discussed.

Walker, James L.↗

Synthesis and characterization of porous structured ZnO thin film for dye sensitized solar cell applications

Zinc oxide (ZnO) and zinc oxide/eosin yellow (ZnO/EY) thin films were potentiostatically deposited onto fluorine doped tin oxide (FTO) glass substrate. Effect of eosin yellow dye on structural, morphological and optical properties was studied. X-ray diffraction patterns, micro Raman spectra and photoluminescence (PL) spectra reveal hexagonal wurtzite structure with less atomic defects in 101 plane orientation of the ZnO/EY film. Scanning electron microscopy (SEM) images show flower for ZnO and porous like structure for ZnO/EY thin film, respectively. DSSC was constructed and evaluated by measuring the current density verses voltage curve.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robotic Non-destructive Test of Concrete Structures with GPR, Impact Echo and 3D Vision - 19540

Structural members come across with various internal defects that cannot be evaluated visually. Instead, hand-held nondestructive sensors are used to detect such defects. In many situations, the hand-held NDT is not possible in high-risk structures because of limited access or safety issues. Therefore, Robotic NDT plays major role in assessing such structures. Robot Operating Systems (ROS) is a powerful open source tool, which is used to program and control robots and other devices enabling one to use sensors, devices and new functionalities such as autonomous navigation, visual perception. For the research presented, ROS is used to program the Sawyer robot arm manufactured by Rethink Robotics. The control system for the robot ensures the ability to adapt to different weights of integrated measuring devices and measured force applied against the wall with a wheeled measuring device while making a remote sweep. Twelve reinforced concrete (RC) beams built with characterized defects are evaluated with the robotic arm integrated with the measuring devices. The RC beams are characterized by voids, corrosion and debonding problems of rebars. The Impact Echo and Ground Penetrating Radar (GPR) devices attached to the robot arm are used to measure the material properties of the concrete beams. The robot arm ensures consistency and uniformity of measurement even in obscure locations. Infrared cameras are used to obtain 3D images of the surfaces of the concrete structures. Roughness is analyzed using computer vision techniques prior to the use of other sensors that are in touch with the surfaces. The computer vision is also used to handle the images collected from GPR sensor. Hand-held NDE is also performed to verify the results obtained by robotic examination. (authors)

42 ENGINEERING↗

Bubble explosion induced melt pool instabilities in electron beam melting of aluminum alloy

Electron beam melting (EBM) is an additive manufacturing technology that can process materials and manufacture components otherwise impossible or uneconomical. However, defects, including porosity and surface irregularities, are widely reported in EBM-built components, and their formation mechanisms are not fully understood. Here, using in-situ high-speed synchrotron X-ray imaging, we reveal that bubble explosions in Al6061 during EBM induce melt pool instabilities contributing to defect formation. The melt pool and keyhole evolve through three stages: (1) initial formation of a melt pool, (2) subsurface bubble formation and explosion, and (3) periodic keyhole oscillation. During scanning, periodic bubble explosions can eject molten liquid as spatters and disturb the vapor depression and melt pool, contributing to surface humping, that may trigger lack-of-fusion defects in subsequent layers. The physical insights we report could provide guidance for EBM machine development, process innovation, alloy design and model development.

36 MATERIALS SCIENCE↗

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

14 SOLAR ENERGY↗

3D Localization of Defects in Facility Inspection

Wind tunnels are crucial facilities that support the aerospace industry. However, these facilities are large, complex, and pose unique maintenance and inspection requirements. Manual inspections to identify defects such as cracks, missing fasteners, leaks, and foreign objects are important but labor and schedule intensive. Our goal is to utilize small Unmanned Aircraft Systems (sUAS) and computer vision-based analysis to automate the inspection of the interior and exterior of NASA’s critical wind tunnel facilities. We detect missing fasteners as our defect class, and detect existing fasteners to provide potential future missing fastener sites for preventative maintenance. These detections are done on both 2D raw images and in 3D space to provide a visual reference and real world location to facilitate repairs. A dataset was created consisting of images taken along a grid-like pattern of an interior tunnel section in the AEDC National Full-Scale Aerodynamics Complex (NFAC) at NASA Ames Research Center. Our method uses object detection to create image level bounding boxes of the fasteners and missing fasteners, then uses photogrammetry to create a mapping from 2D image locations to 3D real world locations. The image level bounding boxes and the 2D to 3D mapping are then combined to determine the 3D location of the defects. We describe the data collection, photogrammetry, and computer vision techniques used for object detection as well as a quantitative analysis of the method.

Small Unmanned Aircraft Systems (sUAS)↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

Bloch oscillations in tight-binding lattices with defects

Defects in tight-binding lattices generally destroy the onset of Bloch oscillations (BOs) and the periodic self-imaging of the wave packet due to the lack of an equally spaced Wannier-Stark ladder spectrum. Here it is shown that localized and extended defects in the lattice can be engineered to be transparent for BOs. Such lattices are synthesized from the defect-free lattice by the technique of intertwining operators generally employed in supersymmetric quantum mechanics. The energy spectrum of the synthesized lattices differs from the Wannier-Stark ladder of the defect-free lattice because of the missing of pairs of resonances in the ladder, thus ensuring the persistence of BOs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualizing heterogeneous dipole fields by terahertz light coupling in individual nano-junctions

The challenge underlying superconducting quantum computing is to remove materials bottleneck for highly coherent quantum devices. The nonuniformity and complex structural components in the underlying quantum circuits often lead to local electric field concentration, charge scattering, dissipation and ultimately decoherence. Here we visualize interface dipole heterogeneous distribution of individual Al/AlO$_{x}$/Al junctions employed in transmon qubits by broadband terahertz scanning near-field microscopy that enables the non-destructive and contactless identification of defective boundaries in nano-junctions at an extremely precise nanoscale level. Our THz nano-imaging tool reveals an asymmetry across the junction in electromagnetic wave-junction coupling response that manifests as hot (high intensity) vs cold (low intensity) spots in the spatial electrical field structures and correlates with defected boundaries from the multi-angle deposition processes in Josephson junction fabrication inside qubit devices. The demonstrated local electromagnetic scattering method offers high sensitivity, allowing for reliable device defect detection in the pursuit of improved quantum circuit fabrication for ultimately optimizing coherence times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charging Reactions Promoted by Geometrically Necessary Dislocations in Battery Materials Revealed by In Situ Single-Particle Synchrotron Measurements

Crystallographic defects exist in many redox active energy materials, e.g., battery and catalyst materials, which significantly alter their chemical properties for energy storage and conversion. However, there is lack of quantitative understanding of the interrelationship between crystallographic defects and redox reactions. Herein, crystallographic defects, such as geometrically necessary dislocations, are reported to influence the redox reactions in battery particles through single-particle, multimodal, and in situ synchrotron measurements. Through Laue X-ray microdiffraction, many crystallographic defects are spatially identified and statistically quantified from a large quantity of diffraction patterns in many layered oxide particles, including geometrically necessary dislocations, tilt boundaries, and mixed defects. The in situ and ex situ measurements, combining microdiffraction and X-ray spectroscopy imaging, reveal that LiCoO 2 particles with a higher concentration of geometrically necessary dislocations provide deeper charging reactions, indicating that dislocations may facilitate redox reactions in layered oxides during initial charging. The present study illustrates that a precise control of crystallographic defects and their distribution can potentially promote and homogenize redox reactions in battery materials.

25 ENERGY STORAGE↗

A mechanistic study on environment gas in laser powder bed fusion

A variety of protective or reactive environmental gases have recently gained growing attention in laser-based metal additive manufacturing (AM) technologies due to their unique thermophysical properties and the potential improvements they can bring to the build processes. However, much remains unclear regarding the effects of different gas environments on critical phenomena in laser AM, such as rapid cooling, energy coupling, and defect generation. Through simultaneous high-speed synchrotron x-ray imaging and thermal imaging, we identify distinct effects of two environmental gases in laser AM and gained a deeper understanding of the underlying mechanisms. Compared to the commonly used protective gas, argon, it is found that helium has a negligible effect on cooling the part. However, helium can suppress unstable keyholes by decreasing effective energy absorption, thus mitigating keyhole porosity generation and reducing pore size under certain processing conditions. In conclusion, these observations provide guidelines for the strategic use of environmental gases in laser AM to produce parts with improved quality.

36 MATERIALS SCIENCE↗