Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A large area multi-element telescope for measuring the cosmic ray isotope composition

To measure the isotopic composition of cosmic rays up to Fe an instrument is needed with good isotopic resolution and a large exposure. The large geometry needed for a balloon-borne detector has been obtained with large mapped detectors and a trajectory determining spark chamber. The instrument achieves isotopic resolution only for stopping particles. For low charge particles where there is no Cerenkov response the detector works as a multiple dE/dx-Range-Energy detector. For higher charges where scintillator saturation becomes important it becomes a Cerenkov-range measurement.

Fisher, A. J.↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sealed high-pressure x-ray detector

Detector is filled to pressure of 2 atm with mixture of 95% xenon and 5% methane for recording hard x-ray (50-to100-keV0 images with spatial resolution of about 1 mm. Being sealed, detector requires no gas purification or replenishment after initial fill. Potential areas of application include nuclear medicine, and x-ray or gamma-ray astronomy.

Gorenstein, P.↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗

Modeling Charge Collection in Detector Arrays

A detector array charge collection model has been developed for use as an engineering tool to aid in the design of optical sensor missions for operation in the space radiation environment. This model is an enhancement of the prototype array charge collection model that was developed for the Next Generation Space Telescope (NGST) program. The primary enhancements were accounting for drift-assisted diffusion by Monte Carlo modeling techniques and implementing the modeling approaches in a windows-based code. The modeling is concerned with integrated charge collection within discrete pixels in the focal plane array (FPA), with high fidelity spatial resolution. It is applicable to all detector geometries including monolithc charge coupled devices (CCDs), Active Pixel Sensors (APS) and hybrid FPA geometries based on a detector array bump-bonded to a readout integrated circuit (ROIC).

Hardage, Donna↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

Ground based infrared astronomy

Infrared spectroscopic instrumentation has been developed for ground-based measurements of astrophysical objects in the intermediate infrared. A conventional Michelson interferometer is limited for astronomical applications in the intermediate infrared by quantum noise fluctuations in the radiation form the source and/or background incident on the detector, and the multiplex advantage is no longer available. One feasible approach to recovering the multiplex advantage is post-dispersion. The infrared signal after passing through telescope and interferometer, is dispersed by a low resolution grating spectrometer onto an array of detectors. The feasibility of the post-dispersion system has been demonstrated with observations of astrophysical objects in the 5 and 10 micrometer atmospheric windows from ground-based telescopes. During FY87/88 the post-disperser was used at the Kitt Peak 4-meter telescope and McMath telescope with facility Fourier transform spectrometers. Jupiter, Saturn, Mars, and Venus were observed. On Jupiter, the resolution at 12 micrometer was 0.01/cm, considerably higher than had been acheived previously. The spectrum contains Jovian ethane and acetylene emission. Construction was begun on the large cryogenic grating spectrometer.

Jennings, D. E.↗

Neutrino interaction vertex reconstruction in DUNE with Pandora deep learning

The Pandora Software Development Kit and algorithm libraries perform reconstruction of neutrino interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at the Deep Underground Neutrino Experiment, which will operate four large-scale liquid argon time projection chambers at the far detector site in South Dakota, producing high-resolution images of charged particles emerging from neutrino interactions. While these high-resolution images provide excellent opportunities for physics, the complex topologies require sophisticated pattern recognition capabilities to interpret signals from the detectors as physically meaningful objects that form the inputs to physics analyses. A critical component is the identification of the neutrino interaction vertex. Subsequent reconstruction algorithms use this location to identify the individual primary particles and ensure they each result in a separate reconstructed particle. A new vertex-finding procedure described in this article integrates a U-ResNet neural network performing hit-level classification into the multi-algorithm approach used by Pandora to identify the neutrino interaction vertex. The machine learning solution is seamlessly integrated into a chain of pattern-recognition algorithms. The technique substantially outperforms the previous BDT-based solution, with a more than 20% increase in the efficiency of sub-1 cm vertex reconstruction across all neutrino flavours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple detector focal plane array ultraviolet spectrometer for the AMPS laboratory

The possibility of meeting the requirements of the amps spectroscopic instrumentation by using a multi-element focal plane detector array in a conventional spectrograph mount was examined. The requirements of the detector array were determined from the optical design of the spectrometer which in turn depends on the desired level of resolution and sensitivity required. The choice of available detectors and their associated electronics and controls was surveyed, bearing in mind that the data collection rate from this system is so great that on-board processing and reduction of data are absolutely essential. Finally, parallel developments in instrumentation for imaging in astronomy were examined, both in the ultraviolet (for the Large Space Telescope as well as other rocket and satellite programs) and in the visible, to determine what progress in that area can have direct bearing on atmospheric spectroscopy.

Feldman, P. D.↗

High Performance Pd/4H-SiC Epitaxial Schottky Barrier Radiation Detectors for Harsh Environment Applications

Although many refractory metals have been investigated as the choice of contact metal in 4H-SiC devices, palladium (Pd) as a Schottky barrier contact for 4H-SiC radiation detectors for harsh environment applications has not been investigated adequately. Pd is a refractory metal with high material weight-to-thickness ratio and a work function as high as nickel, one of the conventional metal contacts for high performing 4H-SiC Schottky barrier detectors (SBDs). In this article, Pd/4H-SiC epitaxial SBDs have been demonstrated for the first time as a superior self-biased (0 V applied bias) radiation detector when compared to benchmark Ni/4H-SiC SBDs. The Pd/4H-SiC SBD radiation detectors showed a very high energy resolution of 1.9% and 0.49% under self- and optimized bias, respectively, for 5486 keV alpha particles. The SBDs demonstrated a built-in voltage (V bi ) of 2.03 V and a hole diffusion length (L d ) of 30.8 µm. Such high V bi and L d led to an excellent charge collection efficiency of 76% in the self-biased mode. Capacitance mode deep level transient spectroscopy (DLTS) results revealed that the “lifetime-killer” Z 1/2 trap centers were present in the 4H-SiC epilayer. Another deep level trap was located at 1.09 eV below the conduction band minimum and resembles the EH5 trap with a concentration of 1.98 × 10 11 cm –3 and capture cross-section 1.7 × 10 –17 cm –2 ; however, the detector performance was found to be limited by charge trapping in the Z 1/2 center. The results presented in this article revealed the unexplored potential of a wide bandgap semiconductor, SiC, as high-efficiency self-biased radiation detectors. Such high performance self-biased radiation detectors are poised to address the longstanding problem of designing self-powered sensor devices for harsh environment applications e.g., advanced nuclear reactors and deep space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning the Superconducting Transition Temperature of Co-sputtered Iridium and Platinum Films

A superconducting film with a tunable low transition temperature (Tc) is required in high-resolution Transition-Edge Sensor (TES) detectors, which have applications including dark matter detection, low threshold coherent elastic neutrino nucleus scattering measurement, and X-ray spectroscopy. We have been investigating a new approach to tune the Tc of superconducting thin films fabricated by co-sputtering Iridium and Platinum. The effects of Pt concentration and deposition parameters on the films' structural, electrical, and superconducting properties have been studied. AFM and XRD techniques and low temperature resistance measurements have been utilized for film characterization. By varying the Pt concentration and deposition parameters when co-sputtering, we have successfully achieved controllable tuning of Tc in the range of 30-200 mK. The experimental results demonstrate co-sputtering as a viable method for controlling the Tc of Ir-based thin films that can be applied to fabricating high-resolution TESs.

Yefremenko, V. G.↗

Detectability of geothermal areas using Skylab X-5 data

The results are presented of a study which was undertaken to determine if data from a single near-noon pass of Skylab could be used to detect geothermal areas. The size and temperature requirements for a geothermally heated area to be seen by Skylab S-192 MSS X-5 thermal sensor were calculated. This sensor obtained thermal data with the highest spatial resolution of any nonmilitary satellite system. Only very large hot areas could be expected to be unambiguously recognized with a single data set from this instrument. The study area chosen was The Geysers geothermal field in Sonoma County, California, the only geothermal area of significant size scanned by Skylab. Unfortunately, 95% of the Skylab thermal channel data was acquired within 3 hours of local noon. For The Geysers area only daytime X-5 data were available. An analysis of the thermal channel data (10.2 to 12.5 um) revealed that ground temperatures determined by Skylab were normally distributed. No anomalous hot spots were apparent. Computer enhancement techniques were used to delineate the hottest 100 and 300 ground areas (pixel, 75 m by 75 m) within the study region. It was found that the Skylab MSS with the X-5 thermal detector does not have sufficient spatial resolution to locate unambiguously from daytime data any but the largest and hottest convectively created geothermal features, which in general are prominent enough to have been previously recognized.

Siegal, B. S.↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Spectral evolution of gamma-ray bursts

BATSE's Spectral Detectors provide a series of high resolution spectra over the duration of a gamma-ray burst; fits to these spectra show the evolution of the continuum as the burst progresses. The burst continuum can usually be fit by the spectral form AE sup alpha exp(-E/kT) from around 25 keV to more than 3 MeV, with varying trends in the value and evolution of the spectral parameters. As a result of limited statistics for E greater than 1 - 2 MeV in the individual spectra, a high energy power law is not required. Only long duration strong bursts can be studied by fitting a series of spectra, and therefore our conclusions concern only this class of burst. The bursts we analyzed tend to be characterized by a hard-to-soft trend both for individual intensity spikes and for the burst as a whole: the hardness leads the count rate in spectra which resolve the temporal variations, while the hardness of successive spikes decreases. We also summarize the performance of the Spectral Detectors and the development of analysis tools to date.

Band, D.↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗