Search NASA⌕ Search

SEARCH · Search NASA

Results for “dilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Structure of the lamin A/C R482W mutant responsible for dominant familial partial lipodystrophy (FPLD)

Proteins of the A-type lamin family, which consists of two members, lamin A and lamin C, are the major components of a thin proteinaceous filamentous meshwork, the lamina, that underlies the inner nuclear membrane. A-type lamins have recently become the focus of extensive functional studies as a consequence of the linking of at least eight congenital diseases to mutations in the lamin A/C gene (LMNA). This spectrum of pathologies, which mostly manifest themselves as dominant traits, includes muscle dystrophies, dilated cardiomyopathies, the premature aging syndrome Hutchinson-Guilford progeria and familial partial lipodystrophy (FPLD). The crystal structure of the lamin A/C mutant R482W, a variant that causes FPLD, has been determined at 1.5 {angstrom} resolution. A completely novel aggregation state of the C-terminal globular domain and the position of the mutated amino-acid residue suggest means by which the mutation may affect lamin A/C-protein and protein-DNA interactions.

36 MATERIALS SCIENCE↗

Improving the diffraction of full-length human selenomethionyl metavinculin crystals by streak-seeding

Metavinculin is an alternatively spliced isoform of vinculin that has a 68-residue insert in its tail domain (1134 total residues) and is exclusively expressed in cardiac and smooth muscle tissue, where it plays important roles in myocyte adhesion complexes. Mutations in the metavinculin-specific insert are associated with dilated cardiomyopathy (DCM) in man. Crystals of a DCM-associated mutant of full-length selenomethionine-labeled metavinculin grown by hanging-drop vapor diffusion diffracted poorly and were highly sensitive to radiation, preventing the collection of a complete X-ray diffraction data set at the highest possible resolution. Streak-seeding markedly improved the stability, crystal-growth rate and diffraction quality of DCM-associated mutant metavinculin crystals, allowing complete data collection to 3.9 {angstrom} resolution. These crystals belonged to space group P4{sub 3}2{sub 1}2, with two molecules in the asymmetric unit and unit-cell parameters a = b = 170, c = 211 {angstrom}, {alpha} = {beta} = {gamma} = 90{sup o}.

59 BASIC BIOLOGICAL SCIENCES↗

From crystal color symmetry to quantum spacetime

More than one hundred years after the inception of relativistic physics, the concept of time remains incompletely understood. Relativity provides means to perform calculations of geometrical properties of spacetime, such as distances or curvature, and to interpret them in terms of physical observations, for instance as time dilation or gravitational effects. However, an intuitive understanding of spacetime is complicated, not so much because it is four-dimensional (which, after all, can be evaded by visualizing twodimensional cross sections) but mainly because its geometry does not obey Euclid’s axioms even in the absence of curvature. Through a well defined and clever transformation (RBS: renormalized blended spacetime), Venkatraman Gopalan (2021) has demonstrated how the hyperbolic geometry in Minkowski spacetime can be mapped to a circular Euclidean geometry. In particular, Lorentzian boosts become Euclidean rotations which enables new frontiers of exploration in color symmetry and magnetic crystals. His idea of general relativistic spacetime crystals and how to obtain them is both powerful and broad, although the notion of relativistic crystals and lattices in two dimensions has existed for a while (Janner & Ascher, 1969a,b). Finally, the breadth of this new work is underlined by the present opinion piece, written by two co-authors with distinct yet connected areas of expertise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fibre optic extensometer for high radiation and high temperature nuclear applications

In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200 nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400 deg.C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10{sup -2} i.e 5000{mu}{epsilon} for an increase in temperature of 300-400 deg. C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100{mu}m (< 1 {mu}m error), at room temperature. The displacement measured can reach 250{mu}m (20000{mu}{epsilon} with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Learning Latent Interactions for Event Identification via Graph Neural Networks and PMU Data

Phasor measurement units (PMUs) are being widely installed on power systems, providing a unique opportunity to enhance wide-area situational awareness. One essential application is the use of PMU data for real-time event identification. However, how to take full advantage of all PMU data in event identification is still an open problem. Thus, we propose a novel method that performs event identification by mining interaction graphs among different PMUs. The proposed interaction graph inference method follows an entirely data-driven manner without knowing the physical topology. Moreover, unlike previous works that treat interactive learning and event identification as two different stages, our method learns interactions jointly with the identification task, thereby improving the accuracy of graph learning and ensuring seamless integration between the two stages. Moreover, to capture multi-scale event patterns, a dilated inception-based method is investigated to perform feature extraction of PMU data. To test the proposed data-driven approach, a large real-world dataset from tens of PMU sources and the corresponding event logs have been utilized in this work. We report numerical results validate that our method has higher classification accuracy compared to previous methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-View Convolutional Neural Network for Data Spoofing Cyber-Attack Detection in Distribution Synchrophasors

Security of Distribution Synchrophasors Data (DSD) is of paramount importance as the data is used for critical smart grid applications including situational awareness, advanced protection, and dynamic control. Unfortunately, the DSD are attractive targets for malicious attackers aiming to damage grid. Data spoofing is a new class of deceiving attack, where the DSD of one Phasor Measurement Units (PMUs) is tampered by other PMUs thereby spoiling measurement based applications. In order to address this issue, a source authentication based data spoofing attack detection method is proposed using Multi-view Convolutional Neural Network (MCNN). First, common components embedded in raw frequency measurements from DSD are removed by Savitzky-Golay (SG) filter. Second, fast S transform (FST) is utilized to extract representative spatial fingerprints via time frequency analysis. Third, the spatial fingerprint is fed to MCNN, which combines dilated and standard convolutions for automatic feather extraction and source identification. Finally, according to the output of MCNN, spoofing attack detection is performed via threshold criterion. Extensive experiments with actual DSD from multiple locations in FNET/Grideye are conducted to verify the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Ultra-Short-Term Spatiotemporal Forecasting of Renewable Resources: An Attention Temporal Convolutional Network Based Approach

The rapid increase in the penetration of renewable energy resources characterized by high variability and uncertainty is bringing new challenges to the power system operation. To ensure the efficient and reliable operation of electric grid, an accurate and general short-term forecasting algorithm with interpretability is desired. Moreover, the extensive off-site information provided by the proliferation of new renewable plants stimulates the interests in the spatiotemporal forecasting. In this paper, an attention temporal convolutional network, which is built on stacked dilated causal convolutional networks and attention mechanisms, is proposed to perform the ultra-short-term spatiotemporal forecasting of renewable resources. Compared with the existing spatiotemporal forecasting methods, the presented model needs no domain knowledge and can be applied to different forecasting tasks such as solar generation and wind speed forecasting. Here, the attention mechanism improves the interpretability. The algorithm can be used to produce both point and probabilistic forecasts. Numerical results on the data sets from National Renewable Energy Laboratory show superior performance over five baselines, in terms of skill scores. Compared with the baselines, the average improvements of accuracy introduced by the proposed method for the point and probabilistic forecasting are 15.08% and 15.85%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intermittent supplementation with fisetin improves arterial function in old mice by decreasing cellular senescence

Cellular senescence and the senescence-associated secretory phenotype (SASP) contribute to age-related arterial dysfunction, in part, by promoting oxidative stress and inflammation, which reduce the bioavailability of the vasodilatory molecule nitric oxide (NO). In the present study, we assessed the efficacy of fisetin, a natural compound, as a senolytic to reduce vascular cell senescence and SASP factors and improve arterial function in old mice. We found that fisetin decreased cellular senescence in human endothelial cell culture. In old mice, vascular cell senescence and SASP-related inflammation were lower 1 week after the final dose of oral intermittent (1 week on—2 weeks off—1 weeks on dosing) fisetin supplementation. Old fisetin-supplemented mice had higher endothelial function. Leveraging old p16-3MR mice, a transgenic model allowing genetic clearance of p16 INK4A -positive senescent cells, we found that ex vivo removal of senescent cells from arteries isolated from vehicle- but not fisetin-treated mice increased endothelium-dependent dilation, demonstrating that fisetin improved endothelial function through senolysis. Enhanced endothelial function with fisetin was mediated by increased NO bioavailability and reduced cellular- and mitochondrial-related oxidative stress. Arterial stiffness was lower in fisetin-treated mice. Ex vivo genetic senolysis in aorta rings from p16-3MR mice did not further reduce mechanical wall stiffness in fisetin-treated mice, demonstrating lower arterial stiffness after fisetin was due to senolysis. Lower arterial stiffness with fisetin was accompanied by favorable arterial wall remodeling. The findings from this study identify fisetin as promising therapy for clinical translation to target excess cell senescence to treat age-related arterial dysfunction.

59 BASIC BIOLOGICAL SCIENCES↗

Structure, signaling mechanism and regulation of the natriuretic peptide receptor guanylate cyclase.

Atrial natriuretic peptide (ANP) and the homologous B-type natriuretic peptide are cardiac hormones that dilate blood vessels and stimulate natriuresis and diuresis, thereby lowering blood pressure and blood volume. ANP and B-type natriuretic peptide counterbalance the actions of the renin-angiotensin-aldosterone and neurohormonal systems, and play a central role in cardiovascular regulation. These activities are mediated by natriuretic peptide receptor-A (NPRA), a single transmembrane segment, guanylyl cyclase (GC)-linked receptor that occurs as a homodimer. Here, we present an overview of the structure, possible chloride-mediated regulation and signaling mechanism of NPRA and other receptor GCs. Earlier, we determined the crystal structures of the NPRA extracellular domain with and without bound ANP. Their structural comparison has revealed a novel ANP-induced rotation mechanism occurring in the juxtamembrane region that apparently triggers transmembrane signal transduction. More recently, the crystal structures of the dimerized catalytic domain of green algae GC Cyg12 and that of cyanobacterium GC Cya2 have been reported. These structures closely resemble that of the adenylyl cyclase catalytic domain, consisting of a C1 and C2 subdomain heterodimer. Adenylyl cyclase is activated by binding of G{sub s}{alpha} to C2 and the ensuing 7{sup o} rotation of C1 around an axis parallel to the central cleft, thereby inducing the heterodimer to adopt a catalytically active conformation. We speculate that, in NPRA, the ANP-induced rotation of the juxtamembrane domains, transmitted across the transmembrane helices, may induce a similar rotation in each of the dimerized GC catalytic domains, leading to the stimulation of the GC catalytic activity.

59 BASIC BIOLOGICAL SCIENCES↗

Thermo-rheological snapshot of melter feed conversion to glass

Slurry feed charged into an electric melter creates a layer of reacting and melting material (termed cold cap) that floats on the surface of molten glass. The rheological behavior of heated melter feed affects the spreading of slurry at the top of the cold cap and the stability of the primary foam, affecting cold-cap coverage and melter plenum temperatures. The apparent viscosity of a high-alumina high-level waste melter feed was assessed by thermomechanical analysis, high-temperature viscometer, and the hot stage microscopy method, yielding viscosity estimates from ≈10 7.5 Pa s at 550°C to ≈10 2.5 Pa s at 1050°C. As the temperature of feed materials increased, their state changed from rigid solid to dilatant fluid, to pseudoplastic bubbly liquid with dissolving solids, to fully developed foam, and finally to Newtonian glass melt.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Convolutional networks for vehicle track segmentation

Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are unable to capture natural track features such as continuity and parallelism. More powerful, but computationally expensive models can be used in offline settings. We present an approach that uses dilated convolutional networks consisting of a series of 3-by-3 convolutions to segment vehicle tracks. The design of our networks considers the fact that remote sensing applications tend to operate in low power and have limited training data. As a result, we aim for small, efficient networks that can be trained end-to-end to learn natural track features entirely from limited training data. We demonstrate that our 6-layer network, trained on just 90 images, is computationally efficient and improves the F-score on a standard dataset to 0.992, up from 0.959 obtained by the current state-of-the-art method.

47 OTHER INSTRUMENTATION↗

Object detectability at increased ambient lighting conditions

Under typical dark conditions encountered in diagnostic reading rooms, a reader's pupils will contract and dilate as the visual focus intermittently shifts between the high luminance display and the darker background wall, resulting in increased visual fatigue and the degradation of diagnostic performance. A controlled increase of ambient lighting may, however, reduce the severity of these pupillary adjustments by minimizing the difference between the luminance level to which the eyes adapt while viewing an image (L{sub adp}) and the luminance level of diffusely reflected light from the area surrounding the display (L{sub s}). Although ambient lighting in reading rooms has conventionally been kept at a minimum to maintain the perceived contrast of film images, proper Digital Imaging and Communications in Medicine (DICOM) calibration of modern medical-grade liquid crystal displays can compensate for minor lighting increases with very little loss of image contrast. This paper describes two psychophysical studies developed to evaluate and refine optimum reading room ambient lighting conditions through the use of observational tasks intended to simulate real clinical practices. The first study utilized the biologic contrast response of the human visual system to determine a range of representative L{sub adp} values for typical medical images. Readers identified low contrast horizontal objects in circular foregrounds of uniform luminance (5, 12, 20, and 30 cd/m{sup 2}) embedded within digitized mammograms. The second study examined the effect of increased ambient lighting on the detection of subtle objects embedded in circular foregrounds of uniform luminance (5, 12, and 35 cd/m{sup 2}) centered within a constant background of 12 cd/m{sup 2} luminance. The images were displayed under a dark room condition (1 lux) and an increased ambient lighting level (50 lux) such that the luminance level of the diffusely reflected light from the background wall was approximately equal to the image L{sub adp} value of 12 cd/m{sup 2}. Results from the first study demonstrated that observer true positive and false positive detection rates and true positive detection times were considerably better while viewing foregrounds at 12 and 20 cd/m{sup 2} than at the other foreground luminance levels. Results from the second study revealed that under increased room illuminance, the average true positive detection rate improved a statistically significant amount from 39.3% to 55.6% at 5 cd/m{sup 2} foreground luminance. Additionally, the true positive rate increased from 46.4% to 56.6% at 35 cd/m{sup 2} foreground luminance, and decreased slightly from 90.2% to 87.5% at 12 cd/m{sup 2} foreground luminance. False positive rates at all foreground luminance levels remained approximately constant with increased ambient lighting. Furthermore, under increased room illuminance, true positive detection times declined at every foreground luminance level, with the most considerable decrease (approximately 500 ms) at the 5 cd/m{sup 2} foreground luminance. The first study suggests that L{sub adp} of typical mammograms lies between 12 and 20 cd/m{sup 2}, leading to an optimum reading room illuminance of approximately 50-80 lux. Findings from the second study provide psychophysical evidence that ambient lighting may be increased to a level within this range, potentially improving radiologist comfort, without deleterious effects on diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural analysis of cortical porosity applied to HR-pQCT data

Purpose: The investigation of cortical porosity is an important aspect of understanding biological, pathoetiological, and biomechanical processes occurring within the skeleton. With the emergence of HR-pQCT as a noninvasive tool suitable for clinical use, cortical porosity at appendicular sites can be directly visualizedin vivo. The aim of this study was to introduce a novel topological analysis of the cortical pore network for HR-pQCT data and determine the influence of resolution on measures of cortical pore network microstructure and topology. Methods: Cadaveric radii were scanned using HR-pQCT at two different voxel sizes (41 and 82μm) and also using μCT at a voxel size of 18 μm. HR-pQCT and μCT image sets were spatially coregistered. Segmentation and quantification of cortical porosity (Ct.Po) and mean pore diameter (Ct.Po.Dm) were achieved using an established extended cortical analysis technique. Topological classification of individual pores was performed using topology-preserving skeletonization and multicolor dilation algorithms. Based on the pore skeleton topological classification, the following parameters were quantified: total number of planar surface-skeleton canals (N.Slabs), tubular curve-skeleton canals (N.Tubes), and junction elements (N.Junctions), mean slab volume (Slab.Vol), mean tube volume (Tube.Vol), mean slab orientation (Slab.θ), mean tube orientation (Tube.θ), N.Slabs/N.Tubes, and integral (total) slab volume/integral tube volume (iSlab.Vol/iTube.Vol). An in vivo reproducibility study was also conducted to assess short-term precision of the topology parameters. Precision error was characterized using root mean square coefficient of variation (RMSCV%). Results: Correlations toμCT values for Ct.Po were significant for both the 41 and 82 μm HR-pQCT data (41: r{sup 2} = 0.82, p < 0.001, 82: r{sup 2} = 0.75, p < 0.001). For Ct.Po.Dm, only the 41 μm data were significantly predictive of μCT values (r{sup 2} = 0.72, p < 0.01) Data at both HR-pQCT voxel sizes were strongly predictive of the μCT values for N.Slabs (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), N.Tubes (41: r{sup 2} = 0.94, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), and N.Junctions (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.78, p < 0.001), though proportional bias was evident in these correlations. Weak correlations were seen for iSlab.Vol/iTube.Vol at both voxel sizes (41: r{sup 2} = 0.52, p < 0.01; 82: r{sup 2} = 0.39, p < 0.05). Slab.Vol was significantly correlated to μCT data at 41 μm (r{sup 2} = 0.60, p < 0.01) but not at 82 μm, while Tube.Vol was significantly correlated at both voxel sizes (41: r{sup 2} = 0.79, p < 0.001; 82: r{sup 2} = 0.68, p < 0.01). In vivo precision error for these parameters ranged from 2.31 to 9.68 RMSCV%. Conclusions: Strong correlations betweenμCT- and HR-pQCT-derived measurements were found, particularly in HR-pQCT images obtained at 41 μm. These data are in agreement with our previous study investigating the effect of voxel size on standard HR-pQCT metrics of trabecular and cortical microstructure, and extend our previous findings to include topological descriptors of the cortical pore network.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiautomatic registration of 3D transabdominal ultrasound images for patient repositioning during postprostatectomy radiotherapy

Purpose: The aim of the present work is to propose and evaluate registration algorithms of three-dimensional (3D) transabdominal (TA) ultrasound (US) images to setup postprostatectomy patients during radiation therapy. Methods: Three registration methods have been developed and evaluated to register a reference 3D-TA-US image acquired during the planning CT session and a 3D-TA-US image acquired before each treatment session. The first method (method A) uses only gray value information, whereas the second one (method B) uses only gradient information. The third one (method C) combines both sets of information. All methods restrict the comparison to a region of interest computed from the dilated reference positioning volume drawn on the reference image and use mutual information as a similarity measure. The considered geometric transformations are translations and have been optimized by using the adaptive stochastic gradient descent algorithm. Validation has been carried out using manual registration by three operators of the same set of image pairs as the algorithms. Sixty-two treatment US images of seven patients irradiated after a prostatectomy have been registered to their corresponding reference US image. The reference registration has been defined as the average of the manual registration values. Registration error has been calculated by subtracting the reference registration from the algorithm result. For each session, the method has been considered a failure if the registration error was above both the interoperator variability of the session and a global threshold of 3.0 mm. Results: All proposed registration algorithms have no systematic bias. Method B leads to the best results with mean errors of −0.6, 0.7, and −0.2 mm in left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions, respectively. With this method, the standard deviations of the mean error are of 1.7, 2.4, and 2.6 mm in LR, SI, and AP directions, respectively. The latter are inferior to the interoperator registration variabilities which are of 2.5, 2.5, and 3.5 mm in LR, SI, and AP directions, respectively. Failures occur in 5%, 18%, and 10% of cases in LR, SI, and AP directions, respectively. 69% of the sessions have no failure. Conclusions: Results of the best proposed registration algorithm of 3D-TA-US images for postprostatectomy treatment have no bias and are in the same variability range as manual registration. As the algorithm requires a short computation time, it could be used in clinical practice provided that a visual review is performed.

60 APPLIED LIFE SCIENCES↗

Creation of an atlas of filter positions for fluence field modulated CT

Purpose: Fluence field modulated CT (FFMCT) and volume of interest (VOI) CT imaging applications require adjustment of the profile of the x-ray fluence incident on a patient as a function of view angle. Since current FFMCT prototypes can theoretically take on an infinite number of configurations, measuring a calibration data set for all possible positions would not be feasible. The present work details a methodology for calculating an atlas of configurations that will span all likely body regions, patient sizes, patient positioning, and imaging modes. The hypothesis is that there exists a finite number of unique modulator configurations that effectively span the infinite number of possible fluence profiles with minimal loss in performance. Methods: CT images of a head, shoulder, thorax, abdominal, wrist, and leg anatomical slices were dilated and contracted to model small, medium, and large sized patients. Additionally, the images were positioned from iso-center by three different amounts. The modulator configurations required to compensate for each image were computed assuming a FFMCT prototype, digital beam attenuator, (DBA), was set to equalize the detector exposure. Each atlas configuration should be different from the other atlas configurations. The degree of difference was quantified using the sum of the absolute differences in filter thickness between configurations. Using this metric, a set of unique wedge configurations for which no two configurations have a metric value smaller than some threshold can be constructed. Differences in the total number of incident photons between the unconstrained filters and the atlas were studied as a function of the number of atlas positions for each anatomical site and size/off-centering combination. Results: By varying the threshold used in creating the atlas, it was found that roughly 322 atlas positions provided an incident number of photons within 20% of using 19 440 unique filters (the number of atlas entries ranged from 7213 to 1). Additionally, for VOI applications implemented with a single VOI region, the number of required filter configurations was expressed in a simple closed form solution. Conclusions: The methodology proposed in this work will enable DBA-FFMCT and DBA-VOI imaging in the clinic without the need for patient specific air-scans to be performed. In addition, the methodology proposed here is directly applicable to other modulator designs such as piecewise linear, TomoTherapy multi leaf collimators, 2D fluid arrays, and inverse geometry CT.

60 APPLIED LIFE SCIENCES↗

SU-E-I-91: Quantitative Assessment of Early Hepatocellular Carcinoma and Cavernous Hemangioma of Live Using In-Line Phase-Contrast X-Ray Imaging

Purpose: To investigate the potential utility of in-line phase-contrast imaging (ILPCI) technique with synchrotron radiation in detecting early hepatocellular carcinoma and cavernous hemangioma of live using in vitro model system. Methods: Without contrast agents, three typical early hepatocellular carcinoma specimens and three typical cavernous hemangioma of live specimens were imaged using ILPCI. To quantitatively discriminate early hepatocellular carcinoma tissues and cavernous hemangioma tissues, the projection images texture feature based on gray level co-occurrence matrix (GLCM) were extracted. The texture parameters of energy, inertia, entropy, correlation, sum average, sum entropy, difference average, difference entropy and inverse difference moment, were obtained respectively. Results: In the ILPCI planar images of early hepatocellular carcinoma specimens, vessel trees were clearly visualized on the micrometer scale. Obvious distortion deformation was presented, and the vessel mostly appeared as a ‘dry stick’. Liver textures appeared not regularly. In the ILPCI planar images of cavernous hemangioma of live specimens, typical vessels had not been found compared with the early hepatocellular carcinoma planar images. The planar images of cavernous hemangioma of live specimens clearly displayed the dilated hepatic sinusoids with the diameter of less than 100 microns, but all of them were overlapped with each other. The texture parameters of energy, inertia, entropy, correlation, sum average, sum entropy, and difference average, showed a statistically significant between the two types specimens image (P<0.01), except the texture parameters of difference entropy and inverse difference moment(P>0.01). Conclusion: The results indicate that there are obvious changes in morphological levels including vessel structures and liver textures. The study proves that this imaging technique has a potential value in evaluating early hepatocellular carcinoma and cavernous hemangioma of live.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-05: Robustness of Dose Painting by Numbers in Proton Therapy

Purpose: Proton range uncertainties may cause important dose perturbations within the target volume, especially when steep dose gradients are present as in dose painting. The aim of this study is to assess the robustness against setup and range errors for high heterogeneous dose prescriptions (i.e., dose painting by numbers), delivered by proton pencil beam scanning. Methods: An automatic workflow, based on MATLAB functions, was implemented through scripting in RayStation (RaySearch Laboratories). It performs a gradient-based segmentation of the dose painting volume from 18FDG-PET images (GTVPET), and calculates the dose prescription as a linear function of the FDG-uptake value on each voxel. The workflow was applied to two patients with head and neck cancer. Robustness against setup and range errors of the conventional PTV margin strategy (prescription dilated by 2.5 mm) versus CTV-based (minimax) robust optimization (2.5 mm setup, 3% range error) was assessed by comparing the prescription with the planned dose for a set of error scenarios. Results: In order to ensure dose coverage above 95% of the prescribed dose in more than 95% of the GTVPET voxels while compensating for the uncertainties, the plans with a PTV generated a high overdose. For the nominal case, up to 35% of the GTVPET received doses 5% beyond prescription. For the worst of the evaluated error scenarios, the volume with 5% overdose increased to 50%. In contrast, for CTV-based plans this 5% overdose was present only in a small fraction of the GTVPET, which ranged from 7% in the nominal case to 15% in the worst of the evaluated scenarios. Conclusion: The use of a PTV leads to non-robust dose distributions with excessive overdose in the painted volume. In contrast, robust optimization yields robust dose distributions with limited overdose. RaySearch Laboratories is sincerely acknowledged for providing us with RayStation treatment planning system and for the support provided.

60 APPLIED LIFE SCIENCES↗

TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.

60 APPLIED LIFE SCIENCES↗