Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Fitting the phenomenological MSSM

We perform a global Bayesian fit of the phenomenological minimal supersymmetric standard model (pMSSM) to current indirect collider and dark matter data. The pMSSM contains the most relevant 25 weak-scale MSSM parameters, which are simultaneously fit using 'nested sampling' Monte Carlo techniques in more than 15 years of CPU time. We calculate the Bayesian evidence for the pMSSM and constrain its parameters and observables in the context of two widely different, but reasonable, priors to determine which inferences are robust. We make inferences about sparticle masses, the sign of the {mu} parameter, the amount of fine-tuning, dark matter properties, and the prospects for direct dark matter detection without assuming a restrictive high-scale supersymmetry breaking model. We find the inferred lightest CP-even Higgs boson mass as an example of an approximately prior-independent observable. This analysis constitutes the first statistically convergent pMSSM global fit to all current data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the nanoDot OSLD dosimeter in CT

Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due to changes in beam quality, could be more substantial. In particular, it would likely be necessary to account for variations in CT scan parameters and measurement location when performing CT dosimetry using OSLD.

60 APPLIED LIFE SCIENCES↗

Validation of a Monte Carlo model used for simulating tube current modulation in computed tomography over a wide range of phantom conditions/challenges

Purpose: Monte Carlo (MC) simulation methods have been widely used in patient dosimetry in computed tomography (CT), including estimating patient organ doses. However, most simulation methods have undergone a limited set of validations, often using homogeneous phantoms with simple geometries. As clinical scanning has become more complex and the use of tube current modulation (TCM) has become pervasive in the clinic, MC simulations should include these techniques in their methodologies and therefore should also be validated using a variety of phantoms with different shapes and material compositions to result in a variety of differently modulated tube current profiles. The purpose of this work is to perform the measurements and simulations to validate a Monte Carlo model under a variety of test conditions where fixed tube current (FTC) and TCM were used. Methods: A previously developed MC model for estimating dose from CT scans that models TCM, built using the platform of MCNPX, was used for CT dose quantification. In order to validate the suitability of this model to accurately simulate patient dose from FTC and TCM CT scan, measurements and simulations were compared over a wide range of conditions. Phantoms used for testing range from simple geometries with homogeneous composition (16 and 32 cm computed tomography dose index phantoms) to more complex phantoms including a rectangular homogeneous water equivalent phantom, an elliptical shaped phantom with three sections (where each section was a homogeneous, but different material), and a heterogeneous, complex geometry anthropomorphic phantom. Each phantom requires varying levels of x-, y- and z-modulation. Each phantom was scanned on a multidetector row CT (Sensation 64) scanner under the conditions of both FTC and TCM. Dose measurements were made at various surface and depth positions within each phantom. Simulations using each phantom were performed for FTC, detailed x–y–z TCM, and z-axis-only TCM to obtain dose estimates. This allowed direct comparisons between measured and simulated dose values under each condition of phantom, location, and scan to be made. Results: For FTC scans, the percent root mean square (RMS) difference between measurements and simulations was within 5% across all phantoms. For TCM scans, the percent RMS of the difference between measured and simulated values when using detailed TCM and z-axis-only TCM simulations was 4.5% and 13.2%, respectively. For the anthropomorphic phantom, the difference between TCM measurements and detailed TCM and z-axis-only TCM simulations was 1.2% and 8.9%, respectively. For FTC measurements and simulations, the percent RMS of the difference was 5.0%. Conclusions: This work demonstrated that the Monte Carlo model developed provided good agreement between measured and simulated values under both simple and complex geometries including an anthropomorphic phantom. This work also showed the increased dose differences for z-axis-only TCM simulations, where considerable modulation in the x–y plane was present due to the shape of the rectangular water phantom. Results from this investigation highlight details that need to be included in Monte Carlo simulations of TCM CT scans in order to yield accurate, clinically viable assessments of patient dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers

Purpose: To determine k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} correction factors for machine-specific reference (msr) conditions by Monte Carlo (MC) simulations for reference dosimetry of TomoTherapy static beams for ion chambers Exradin A1SL, A12; PTW 30006, 31010 Semiflex, 31014 PinPoint, 31018 microLion; NE 2571. Methods: For the calibration of TomoTherapy units, reference conditions specified in current codes of practice like IAEA/TRS-398 and AAPM/TG-51 cannot be realized. To cope with this issue, Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] described a new formalism introducing msr factors k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} for reference dosimetry, applicable to static TomoTherapy beams. In this study, those factors were computed directly using MC simulations for Q{sub 0} corresponding to a simplified {sup 60}Co beam in TRS-398 reference conditions (at 10 cm depth). The msr conditions were a 10 Multiplication-Sign 5 cm{sup 2} TomoTherapy beam, source-surface distance of 85 cm and 10 cm depth. The chambers were modeled according to technical drawings using the egs++ package and the MC simulations were run with the egs{sub c}hamber user code. Phase-space files used as the source input were produced using PENELOPE after simulation of a simplified {sup 60}Co beam and the TomoTherapy treatment head modeled according to technical drawings. Correlated sampling, intermediate phase-space storage, and photon cross-section enhancement variance reduction techniques were used. The simulations were stopped when the combined standard uncertainty was below 0.2%. Results: Computed k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} values were all close to one, in a range from 0.991 for the PinPoint chamber to 1.000 for the Exradin A12 with a statistical uncertainty below 0.2%. Considering a beam quality Q defined as the TPR{sub 20,10} for a 6 MV Elekta photon beam (0.661), the additional correction k{sub Q{sub m{sub s{sub r{sub ,Q}{sup f{sub m}{sub s}{sub r}{sub ,}f{sub r}{sub e}{sub f}}}}}} to k{sub Q,Q{sub o}} defined in Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] formalism was in a range from 0.997 to 1.004.Conclusion: The MC computed factors in this study are in agreement with measured factors for chamber types already studied in literature. This work provides msr correction factors for additional chambers used in reference dosimetry. All of them were close to one (within 1%).

61 RADIATION PROTECTION AND DOSIMETRY↗

Atomistic Computer Simulations of Water Interactions and Dissolution of Inorganic Glasses

Computational simulations at the atomistic level play an increasing important role in understanding the structures, behaviors, and the structure-property relationships of glass and amorphous materials. In this paper, we reviewed atomistic simulation methods ranging from first principles calculations and ab initio molecular dynamics (AIMD), to classical molecular dynamics (MD) and meso-scale kinetic Monte Carlo (KMC) simulations and their applications to glass-water interactions and glass dissolutions. Particularly, the use of these simulation methods in understanding the reaction mechanisms of water with oxide glasses, water-glass interfaces, hydrated porous silica gels formation, the structure and properties of multicomponent glasses, and microstructure evolution are reviewed. Here, the advantages and disadvantageous of these methods are discussed and the current challenges and future direction of atomistic simulations in glass dissolution are presented.

36 MATERIALS SCIENCE↗

Backscattering of Relativistic Electrons Incident on a Planar Foil at a Small Angle to Its Surface

Photographs of cross sections of an electron beam backscattered from a thin tungsten target have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of backscattered particles. The angles of back reflection θ{sub br} of electron beams from foils have been measured. A 7.4-MeV microtron has been used as a source of electrons. The experiments have been performed with a tungsten foil 386 mg/cm{sup 2} (200 μm) thick and a tantalum foil 1328 mg/cm{sup 2} (800 μm) thick. Particles have been injected at an angle of α = 10° to the foil surface. The Monte Carlo simulation of the scattering of relativistic electrons incident on a planar target at small angles to its surface has been performed. The spatial and energy distributions of backscattered particle fluxes both transmitted through the target and reflected from it have been calculated. The dependences of fluxes on the direction of injection of particles and on the material and thickness of the target have been considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for table attenuation, obese patient geometry, and differences between the anthropomorphic phantom and MC mathematical phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗

Simulations of particle acceleration in parallel shocks: Direct comparison between Monte Carlo and one-dimensional hybrid codes

We have made a direct comparison between two different computer simulations of a plane, parallel, collisionless shock including particle acceleration to energies typical of those of diffuse ions observed at the earth bow shock. Despite the fact that the one-dimensional hybrid and Monte Carlo techniques employ entirely different algorithms, they give surprisingly close agreement in the overall shapes of the complete distribution functions for protons as well as heavier ions. Both methods show that energetic ions emerge smoothly from the background thermal plasma with approximately the same relative injection rate and that the fraction of the incoming plasma's energy flux that is converted into downstream enthalpy flux of the accelerated population (i.e., the acceleration efficiency) is similar in the two cases. The fraction of the downstream proton distribution made up of superthermal particles is quite large, with at least 10% of the energy flux going into protons with energies above 10 keV. In addition, an upstream precursor, produced by backstreaming energetic particles, is present in both shocks, although the Monte Carlo precursor is considerably longer than that produced in the hybrid shock. These results offer convincing evidence that, at least in these ways, the two simulations are consistent in their description of parallel shock structure and particle acceleration, and they lay the groundwork for development of shock models employing a combination of both methods.

Ellison, Donald C.↗

On-the-fly Doppler Broadening with Probability Table Interpolation for Unresolved Resonance Region in RMC

With the rapid development of computational power and parallel algorithms, Monte Carlo method has been widely investigated and used in neutron transport simulations due to its advantages in geometry modelling and usage of continuous energy point-wise cross sections. Nowadays the road has been paved to couple Monte Carlo codes with thermal-hydraulics codes to make multi-physics calculations. One of the most important aspects of thermal-hydraulics feedback is the detailed temperature distribution, which demands temperature dependent cross sections in neutron transport simulations. The conventional pre-generated cross section libraries at each temperature point are no longer feasible for detailed temperature distributions because of tremendous memory footprint. Hence, different on-the-fly Doppler broadening methods have been proposed for resolved resonance energy region and thermal energy region, such as the interpolation, regress model fitting, multipole representation (MPR), target motion sampling (TMS) and different integration algorithms based on Doppler broadening equation. Compared to resolved resonance energy region and thermal energy region, the representation of cross sections in unresolved resonance region is slightly different. As a result of the limitation of experiment measurements, the overlapped resonances cannot be distinguished from each other and the statistic average resonance parameters are given in the evaluated nuclear data file. In early applications, infinite-dilute pointwise cross sections were obtained from average parameters and were directly used in neutron simulations. However, it was proven that these infinite-dilute pointwise cross sections cannot capture the energy self-shielding effect, thus leading to an overestimate of reaction rates and usually an underestimate of k{sub eff} owing to the increased absorption rates and increased scattering probability to energy below unresolved resonance region where the capture-to-fission ratio is typically higher. This phenomenon is of great importance especially for problems where there is a considerable flux in unresolved resonance region. Then the probability table method was put forward by Levitt to take energy self-shielding effect into account, which provides probability distribution function of cross sections in unresolved resonance region instead of specific cross section values. The probability distribution function is presented in the form of tables and the mean values are equal to the infinite dilution cross sections. To obtain the temperature dependent cross sections in unresolved energy region, there are two different methods. One is to calculate cross sections directly from average resonance parameters and their statistical distributions , which is effective and precise but time-consuming. The other is to interpolate between pre-generated probability table files, which is much more efficient. In this paper, on-the-fly Doppler broadening of cross sections in unresolved resonance regions based on probability tables interpolation was implemented in RMC codes as a supplement to on-the-fly Doppler broadening for resolved resonance energy region and thermal region, which is based on the integration of Doppler broadening equation. The results of criticality calculation and depletion calculation show that on-the-fly Doppler broadening for the whole energy region is accurate and efficient. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Axial grading of inert matrix fuels

Burning actinides in an inert matrix fuel to 750 MWd/kg IHM results in a significant reduction in transuranic isotopes. However, achieving this level of burnup in a standard light water reactor would require residence times that are twice that of uranium dioxide fuels. The reactivity of an inert matrix assembly at the end of life is less than 1/3 of its beginning of life reactivity leading to undesirable radial and axial power peaking in the reactor core. Here we show that axial grading of the inert matrix fuel rods can reduce peaking significantly. Monte Carlo simulations are used to model the assembly level power distributions in both ungraded and graded fuel rods. The results show that an axial grading of uranium dioxide and inert matrix fuels with erbium can reduces power peaking by more than 50% in the axial direction. The reduction in power peaking enables the core to operate at significantly higher power. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ORBITS OF NEARBY PLANETARY NEBULAE AND THEIR INTERACTION WITH THE INTERSTELLAR MEDIUM

We present and analyze the orbits of eight nearby planetary nebulae (PNs) using two different Galactic models. The errors of the derived orbital parameters are determined with a Monte Carlo method. Based on the derived orbital parameters, we find that Sh 2-216, DeHt 5, NGC 7293, A21, and Ton 320 belong to the thin-disk population, and PG 1034 + 001 and A31 belong to the thick-disk population. PuWe 1 probably belongs to the thick-disk population, but its population classification is very uncertain due to the large errors of its derived orbital parameters. The PN-interstellar medium (ISM) interactions are observed for the eight PNs in our sample. The position angles of the proper motions of the PNs are consistent with the directions of the PN-ISM interaction regions. The kinematic ages of PNs are much smaller than the time for them to cross the Galactic plane. Using the models of Borkowski et al. and Soker et al., the PN-ISM interaction can be used to derive the local density of ISM in the vicinity of evolved PNs. According to the three-dimensional hydrodynamic simulations of Wareing et al. (WZO), Sh 2-216, A21, and Ton 320 are in the WZO 3 stage, PG 1034 + 001 and NGC 7293 are in the WZO 1 stage, and PuWe 1 is in the WZO 2 stage.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Variance Reduction for Global k-Eigenvalue Simulations in MCNP

The "criticality" or k-eigenvalue of a nuclear system determines whether the system is critical (k=1), or the extent to which it is subcritical (k<1) or supercritical (k>1). Calculations of k are frequently performed at nuclear facilities to determine the criticality of nuclear reactor cores, spent nuclear fuel storage casks, and other fissile systems. These calculations can be expensive, and current Monte Carlo methods have certain well-known deficiencies. In this project, we have developed and tested a new "functional Monte Carlo" (FMC) method that overcomes several of these deficiencies. The current state-of-the-art Monte Carlo k-eigenvalue method estimates the fission source for a sequence of fission generations (cycles), during each of which M particles per cycle are processed. After a series of "inactive" cycles during which the fission source "converges," a series of "active" cycles are performed. For each active cycle, the eigenvalue and eigenfunction are estimated; after N >> 1 active cycles are performed, the results are averaged to obtain estimates of the eigenvalue and eigenfunction and their standard deviations. This method has several disadvantages: (i) the estimate of k depends on the number M of particles per cycle, (iii) for optically thick systems, the eigenfunction estimate may not converge due to undersampling of the fission source, and (iii) since the fission source in any cycle depends on the estimated fission source from the previous cycle (the fission sources in different cycles are correlated), the estimated variance in k is smaller than the real variance. For an acceptably large number M of particles per cycle, the estimate of k is nearly independent of M; this essentially takes care of item (i). Item (ii) can be addressed by taking M sufficiently large, but for optically thick systems a sufficiently large M can easily be unrealistic. Item (iii) cannot be accounted for by taking M or N sufficiently large; it is an inherent deficiency due to the correlations between fission source estimates. In the new FMC method, the eigenvalue problem (expressed in terms of the Boltzmann equation) is integrated over the energy and direction variables. Then these equations are multiplied by J special "tent" functions in space and integrated over the spatial variable. This yields J equations that are exactly satisfied by the eigenvalue k and J space-angle-energy moments of the eigenfunction. Multiplying and dividing by suitable integrals of the eigenfunction, one obtains J algebraic equations for k and the space-angle-energy moments of the eigenfunction, which contain nonlinear functionals that depend weakly on the eigenfunction. In the FMC method, information from the standard Monte Carlo solution for each active cycle is used to estimate the functionals, and at the end of each cycle the J equations for k and the space-angle-energy moments of the eigenfunction are solved. Finally, these results are averaged over N active cycles to obtain estimated means and standard deviations for k and the space-angle-energy moments of the eigenfunction. Our limited testing shows that for large single fissile systems such as a commercial reactor core, (i) the FMC estimate of the eigenvalue is at least one order of magnitude more accurate than estimates obtained from the standard Monte Carlo approach, (ii) the FMC estimate of the eigenfunction converges and is several orders of magnitude more accurate than the standard estimate, and (iii) the FMC estimate of the standard deviation in k is at least one order of magnitude closer to the correct standard deviation than the standard estimate. These advances occur because: (i) the Monte Carlo estimates of the nonlinear functionals are much more accurate than the direct Monte Carlo estimates of the eigenfunction, (ii) the system of discrete equations that determines the FMC estimates of k is robust, and (iii) the functionals are only very weakly correlated between different fission generations. The FMC method was developed only late in the project and has to date received limited testing. Current work, which is taking place after the conclusion of this project, involves further development and testing for more complex and realistic problems. We expect that the FMC method will become a practical tool for Monte Carlo criticality simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identifying Inconsistencies in Fission Product Yield Evaluations with Prompt Neutron Emission

Here, we present a self-consistency analysis of fission product yield evaluations. Anomalous yields are determined using a series of simple conservation checks and comparing charge distributions with common parameterizations. The summed average prompt neutron multiplicity for both products as a function of the heavy product mass is derived directly from the independent fission product yields with a procedure utilizing average charge conservation. This procedure is validated with Monte Carlo simulations of the de-excitation of the fission fragments in a Hauser-Feshbach statistical decay framework. The derived is compared with experimental data, when available, and then used to determine the prompt neutron multiplicity for the various evaluations. The propagated errors on from the average charge conservation method are significantly lower than the simple summation rules, which reveals that some evaluations are inconsistent with prompt neutron data. We propose possible solutions to remedy the observed inconsistencies and identify sources of the observed differences in between the various evaluation libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-Driven Closures and Assimilation for Stiff Multiscale Random Dynamics

Here, we introduce a data-driven and physics-informed framework for propagating uncertainty in stiff, multiscale random ordinary differential equations (RODEs) driven by correlated (colored) noise. Unlike systems subjected to Gaussian white noise, a deterministic equation for the joint probability density function (PDF) of RODE state variables does not exist in closed form. Moreover, such an equation would require as many phase-space variables as there are states in the RODE system. To alleviate this curse of dimensionality, we instead derive exact, albeit unclosed, reduced-order PDF (RoPDF) equations for low-dimensional observables/quantities of interest. The unclosed terms take the form of state-dependent conditional expectations, which are directly estimated from data at sparse observation times. However, for systems exhibiting stiff, multiscale dynamics, data sparsity introduces regression discrepancies that compound during RoPDF evolution. This is overcome by introducing a kinetic-like defect term to the RoPDF equation, which is learned by assimilating in sparse, low-fidelity RoPDF estimates. Two assimilation methods are considered, namely nudging and deep neural networks, which are successfully tested against Monte Carlo simulations.

97 MATHEMATICS AND COMPUTING↗

Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four-Dimensional Cone Beam CT Guidance

Purpose: To quantify the localization accuracy and intrafraction stability of lung cancer patients treated with frameless, four-dimensional (4D) cone beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) and to calculate and validate planning target volume (PTV) margins to account for the residual geometric uncertainties. Materials and Methods: Sixty-five patients with small peripheral lung tumors were treated with SBRT without a body frame to 54 Gy in three fractions. For each fraction, three 4D-CBCT scans were acquired: before treatment to measure and correct the time-weighted mean tumor position, after correction to validate the correction applied, and after treatment to estimate the intrafraction stability. Patient-specific PTV margins were computed and subsequently validated using Monte Carlo error simulations. Results: Systematic tumor localization inaccuracies (1 SD) were 0.8, 0.8, and 0.9 mm for the left-right, craniocaudal, and anteroposterior direction, respectively. Random localization inaccuracies were 1.1, 1.1, and 1.4 mm. Baseline variations were 1.8, 2.9, and 3.0 mm (systematic) and 1.1, 1.5, and 2.0 mm (random), indicating the importance of image guidance. Intrafraction stability of the target was 1.2, 1.2, and 1.8 mm (systematic) and 1.3, 1.5, and 1.8 mm (random). Monte Carlo error simulations showed that patient-specific PTV margins (5.8-10.5 mm) were adequate for 94% of the evaluated cases (2-28 mm peak-to-peak breathing amplitude). Conclusions: Frameless SBRT can be safely administered using 4D-CBCT guidance. Even with considerable breathing motion, the PTV margins can safely be kept small, allowing patients with larger tumors to benefit from the advantages of SBRT. In case bony anatomy would be used as a surrogate for tumor position, considerably larger PTV margins would be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of Net Energy Gain in Deuterium-Beam Interactions with an Inertially Confined Plasma

It is shown that deuteron beams incident on compressed, tritium-based plasma targets can undergo beam-fusion reactions at a rate greater than Coulomb scattering for a wide range of beam energies and target temperatures. As a result, energy gains of about 5 are possible. The analysis is carried out by treating the beam ions, target ions, and the electrons as separate fluids. Essential to the attainment of high gain is the inclusion of the contribution to the fusion yield from deuterons that gain scattered energy at the expense of directed energy. The results are confirmed by Monte Carlo simulations equivalent to a Fokker-Planck treatment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗