Ultra-Clean Graphene Coating for Robust Operation of High Brightness Photocathodes
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Energy-recovery linacs (ERLs) have been emphasised by the recent (2020) update of the European Strategy for Particle Physics as one of the most promising technologies for the accelerator base of future high-energy physics. The current paper has been written as a base document to support and specify details of the recently published European roadmap for the development of energy-recovery linacs. The paper summarises the previous achievements on ERLs and the status of the field and its basic technology items. The main possible future contributions and applications of ERLs to particle and nuclear physics as well as industrial developments are presented. The paper includes a vision for the further future, beyond 2030, as well as a comparative data base for the main existing and forthcoming ERL facilities. A series of continuous innovations, such as on intense electron sources or high-quality superconducting cavity technology, will massively contribute to the development of accelerator physics at large. Industrial applications are potentially revolutionary and may carry the development of ERLs much further, establishing another shining example of the impact of particle physics on society and its technical foundation with a special view on sustaining nature.
The Qweak experiment at Jefferson Lab will determine the neutral weak charge of the proton to a precision of 4\% by measuring the parity-violating asymmetry of polarized electrons, providing a stringent test of the Standard Model and probing new physics at the 2 TeV scale. For this goal to be achieved, the asymmetry will be measured at an accuracy of 4 parts-per-billion. At this level of precision, it is necessary to minimize the contribution of false asymmetries and keep systematic errors below the part-per-billion level. In this talk, we will discuss techniques for configuring the polarized electron source to minimize changes in the beam intensity, trajectory, and energy under reversal of the beam helicity, as well as beam diagnostics and complementary analysis strategies employed to make remaining corrections to the measured asymmetry.
The present invention is generally directed to catalyzed hot stamp methods for polishing and/or patterning carbon nanotube-containing substrates. In some embodiments, the substrate, as a carbon nanotube fiber end, is brought into contact with a hot stamp (typically at 200-800.degree. C.), and is kept in contact with the hot stamp until the morphology/patterns on the hot stamp have been transferred to the substrate. In some embodiments, the hot stamp is made of material comprising one or more transition metals (Fe, Ni, Co, Pt, Ag, Au, etc.), which can catalyze the etching reaction of carbon with H.sub.2, CO.sub.2, H.sub.2O, and/or O.sub.2. Such methods can (1) polish the carbon nanotube-containing substrate with a microscopically smooth finish, and/or (2) transfer pre-defined patterns from the hot stamp to the substrate. Such polished or patterned carbon nanotube substrates can find application as carbon nanotube electrodes, field emitters, and field emitter arrays for displays and electron sources.
The permanent magnet 2.45 GHz electron cyclotron resonance ion source at Peking University can produce more than 100 mA hydrogen ion beam working at pulsed mode. For the increasing requirements of cluster ions (H{sub 2}{sup +} and H{sub 3}{sup +}) in linac and cyclotron, experimental study was carried out to further understand the hydrogen plasma processes in the ion source for the generation of cluster ions. The constituents of extracted beam have been analyzed varying with the pulsed duration from 0.3 ms to 2.0 ms (repetition frequency 100 Hz) at different operation pressure. The fraction of cluster ions dramatically increased when the pulsed duration was lower than 0.6 ms, and more than 20 mA pure H{sub 3}{sup +} ions with fraction 43.2% and 40 mA H{sub 2}{sup +} ions with fraction 47.7% were obtained when the operation parameters were adequate. The dependence of extracted ion fraction on microwave power was also measured at different pressure as the energy absorbed by plasma will greatly influence electron temperature and electron density then the plasma processes in the ion source. More details will be presented in this paper.
Not provided.
A Wien filter was designed for and tested with a room temperature electron beam ion source (EBIS). Xenon charge state spectra up to the charge state Xe{sup 46+} were resolved as well as the isotopes of krypton using apertures of different sizes. The complete setup consisting of an EBIS and a Wien filter has a length of less than 1 m substituting a complete classical beamline setup. The Wien filter is equipped with removable permanent magnets. Hence total beam current measurements are possible via simple removal of the permanent magnets. In dependence on the needs of resolution a weak (0.2 T) or a strong (0.5 T) magnets setup can be used. In this paper the principle of operation and the design of the Wien filter meeting the requirements of an EBIS are briefly discussed. The first ion beam extraction and separation experiments with a Dresden EBIS are presented.
From April 2008 the PIAVE injector for the ALPI booster was involved in the upgrade of the high voltage platform housing an electron cyclotron resonance (ECR) source. A 14.5 GHz SUPERNANOGAN type ECR replaced the existing source ALICE; at the same time, the whole platform beam line was redesigned and beam shaping and diagnostic system were installed. The source and the platform were ready to be put into operation in January 2009. PIAVE's commissioning was started from late March and completed in May 2009 using an argon beam. A description of the upgrade will be given in the following; beam quality leading to an improved transmission through the injector will be shown. Results on first gaseous and metallic beams produced will also be given.
From the ECR plasma, hot electrons leak across the magnetic lines of force and by striking the plasma chamber produce bremsstrahlung x-rays. The wall bremsstrahlung gives information on the confinement status of hot electron. In our studies, experimental measurements are carried out in NANOGAN electron cyclotron resonance (ECR) ion source for the wall bremsstrahlung x-rays and the results are presented. While optimizing a particular charge state in ECR ion source, experimental parameters are adjusted to get a maximum current. The wall bremsstrahlung components are studied in these cases for understanding the hot electron confinement conditions.
The Holifield Radioactive Ion Beam Facility HRIBF at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams RIBs. Of these, the workhorse is an electron beam plasma EBP ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 IRIS2, for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.
We have performed a systematic study of the bremsstrahlung emission from the electrons in the plasma of a commercial 14.5 GHz electron-cyclotron resonance ion source. The electronic spectral temperature and the product of ionic and electronic densities of the plasma are measured by analyzing the bremsstrahlung spectra recorded for several rare gases (Ar, Kr, and Xe) as a function of the injected power. Within our uncertainty, we find an average temperature of {approx_equal}48 keV above 100 W, with a weak dependency on the injected power and gas composition. Charge state distributions of extracted ion beams have been determined as well, providing a way to disentangle the ionic density from the electronic density. Moreover x-ray emission from highly charged argon ions in the plasma has been observed with a high-resolution mosaic-crystal spectrometer, demonstrating the feasibility for high-precision measurements of transition energies of highly charged ions, in particular, of the magnetic dipole (M1) transition of He-like of argon ions.
VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.
A hexapole magnet for a 14.5 GHz electron cyclotron resonance (ECR) ion source, where the maximum radial field on the wall of the plasma chamber is higher than 1.1 T, has been designed and fabricated. The size of the outer diameter and the number of the sector of the hexapole are optimized for a 14.5 GHz ECR ion source with the help of a three-dimensional field calculation code. Moreover, to make a strong and long-life magnet against the demagnetic field on the hexapole multilayered structure in radial and axial directions is considered in the design. The distributions of the demagnetic fields are estimated by the calculation of the radial field in a hexapole magnet and the axial field from the solenoid coils. Proper grades of magnetic materials depending on the strength of the demagnetic field are applied for the different layers. The magnetic fields of the measured and calculated ones have been compared.
The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project.
Metal-dielectric (MD)-structures in electron cyclotron resonance ion source (ECRIS) devices (partially) restore the plasma ambipolarity and supply cold electrons to the plasma. Both effects lead to an enhancement of the plasma electron density and temperature and significantly increase the performance of this type of ion source. At the same time, MD-structures are well suited to reduce the heat load on cold masses by Bremsstrahlung radiation. Here, we report on experiments at high microwave powers to test the practical use of MD-structures for new, high performance ECRISs with their much higher power densities. The comparatively long conditioning times can be shortened by covering only those parts of the source with MD-structures, which are essential for the improvement.
The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.
In order to provide a variety of ion species to the BNL relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory facilities on a pulse-to-pulse basis, the BNL RHIC electron beam ion source (EBIS) will use injection of primary ''seed'' ions from external low charged ion sources. As part of the prototype for the RHIC EBIS low energy beam transport line, a switchyard for seed ion injection and extracted EBIS ion beams has been constructed. The ion injection line includes a hollow cathode ion source (HCIS), four quadrupole lenses, a switchyard, gridded lenses, and other deflection optics. The HCIS is based on one obtained from CEA Saclay [B. Visentin et al., Phys. Scr., T 71, 204 (1997).] and has been used in bench studies in the production of low charged metal and gas ions, as well as in BNL test EBIS injection studies for the production of highly charged ions. The HCIS geometry and extraction optics have been modified to be able to reach the output currents necessary to seed the test EBIS. Ion currents greater than 60 {mu}A Cu{sup +} and 130 {mu}A Ne{sup +} have been extracted from the modified HCIS at 12-15 kV and plasma aperture of 1-1.5 mm. The HCIS discharge is initiated by a rf coil and can be operated stably at pulse rates from 1 to 100 Hz. Measurement of the emittance of injector beam before and after the injection switchyard will be provided, as well as results from ion injection into the test EBIS using the new injector configuration.
A RIKEN 18 GHz electron cyclotron resonance ion source (18 GHz ECRIS) is used as an external ion source at the Radioactive Ion Beam Factory (RIBF) accelerator complex to produce an intense beam of medium-mass heavy ions (e.g., Ca and Ar). In most components that comprise the RIBF, the control systems (CSs) are integrated by the Experimental Physics and Industrial Control System (EPICS). On the other hand, a non-EPICS-based system has hardwired controllers, and it is used in the 18 GHz ECRIS CS as an independent system. In terms of efficient and effective operation, the 18 GHz ECRIS CS as well as the RIBF CS should be renewed using EPICS. Therefore, we constructed an 18 GHz ECRIS CS by using programmable logic controllers with embedded EPICS technology. In the renewed system, an operational log system was developed as a new feature, for supporting of the 18 GHz ECRIS operation.