Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

SiAl Alloy Feedhorn Arrays: Material Properties, Feedhorn Design, and Astrophysical Applications

We present here a study of the use of the SiAl alloy CE7 for the packaging of silicon devices at cryogenic temperatures. We report on the development of baseplates and feedhorn arrays for millimeter wave bolometric detectors for astrophysics. Existing interfaces to such detectors are typically made either of metals, which are easy to machine but mismatched to the thermal contraction profile of Si devices, or of silicon, which avoids the mismatch but is difficult to directly machine. CE7 exhibits properties of both Si and Al, which makes it uniquely well suited for this application. We measure CE7 to a) superconduct below a critical transition temperature, T (sub c), 1.2 K, b) have a thermal contraction profile much closer to Si than metals, which enables simple mating, and c) have a low thermal conductivity which can be improved by Au-plating. Our investigations also demonstrate that CE7 can be machined well enough to fabricate small structures, such as #0-80 threaded holes, to tight tolerances (approximately 25 microns) in contrast with pure silicon and similar substrates. We have fabricated CE7 baseplates being deployed in the 93 gigahertz polarimetric focal planes used in the Cosmology Large Angular Scale Surveyor (CLASS). We also report on the development of smooth-walled feedhorn arrays made of CE7 that will be used in a focal plane of dichroic 150/220 gigahertz detectors for the CLASS High-Frequency camera.

Ali, Aamir M.↗

Multiparallel Three-Dimensional Optical Microscopy

Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

Nguyen, Lam K.↗

Charge Loss and Charge Sharing Measurements for Two Different Pixelated Cadmium-Zinc-Telluride Detectors

As part of ongoing research at Marshall Space Flight Center, Cadmium-Zinc- Telluride (CdZnTe) pixilated detectors are being developed for use at the focal plane of the High Energy Replicated Optics (HERO) telescope. HERO requires a 64x64 pixel array with a spatial resolution of around 200 microns (with a 6m focal length) and high energy resolution (< 2% at 60keV). We are currently testing smaller arrays as a necessary first step towards this goal. In this presentation, we compare charge sharing and charge loss measurements between two devices that differ both electronically and geometrically. The first device consists of a 1-mm-thick piece of CdZnTe that is sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). The signal is read out using discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe that is sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). Instead of using discrete preamplifiers, the crystal is bonded to an ASIC that provides all of the front-end electronics to each of the 256 pixels. what degree the bias voltage (i.e. the electric field) and hence the drift and diffusion coefficients affect our measurements. Further, we compare the measured results with simulated results and discuss to

Gaskin, Jessica↗

A stabilized large-aperture far-infrared telescope gondola

Description of a recently developed balloon-borne 1-m far-infrared telescope designed to carry out astronomical observations and to map radiation from selected areas of the sky. The telescope optical system consists of a conventional Cassegrain arrangement with an f/2 aluminum primary mirror, spherically figured, which feeds a pyrex secondary mirror to produce an f/13.8 beam at the focal plane with a scale of 15.2 arc sec/mm. Three focal planes are provided. The infrared detectors consist of an array of four gallium-doped germanium bolometers fitted within a two-liter helium dewar. An altitude-azimuth mount design is used for attitude control, with the pointing objectives being achieved in two steps. The azimuth control system is capable of operation in a position mode, in which the sensing element is a servo-driven null magnetometer always pointed north, and in an inertial mode, in which the gyro is uncaged and becomes the azimuth reference. The elevation system also operates in both position and inertial modes. An auxiliary position control, powered by an independent battery and controlled by a separate tone command system, is provided in case of a primary system difficulty.

Hazen, N. L.↗

Breadboard stellar tracker system test report, volume 1

The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.

Kollodge, J. C.↗

SIRTF focal plane technologies

The Space Infrared Telescope Facility (SIRTF) will have three science instruments, the Infrared Array Camera (IRAC) which will obtain multispectral images between 1.8 micron and 26 microns, the Infrared Spectrometer (IRS) which is a set of two dispersive spectrometers covering the wavelength range between 2.5 and 200 microns, and the Multiband Imaging Photometer for SIRTF (MIPS) which is a general-purpose photometric instrument which operates between 30 and 1,200 microns. Taken together, the full wavelength range of these instruments extends from 1.8 micron to 1,200 microns, equivalent to nearly a factor of 700 in photon energy and diffraction limited image size. In addition to supporting this unprecedented spectral and optical coupling requirement, the SIRTF detectors must operate at lower temperatures than previously demonstrated and be optimized for new levels of performance in order to achieve the goals of the science mission. Thus, development of the detector arrays for the SIRTF instruments is one of the most challenging aspects of the instrument development activities.

Capps, Richard W.↗

Theory of dispersive microlenses

A dispersive microlens is a miniature optical element which simultaneously focuses and disperses light. Arrays of dispersive mircolenses have potential applications in multicolor focal planes. They have a 100 percent optical fill factor and can focus light down to detectors of diffraction spot size, freeing up areas on the focal plane for on-chip analog signal processing. Use of dispersive microlenses allows inband color separation within a pixel and perfect scene registration. A dual-color separation has the potential for temperature discrimination. We discuss the design of dispersive microlenses and present sample results for efficient designs.

Herman, B.↗

The Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS) on the Landsat Data Continuity Mission (LDCM)

The Landsat Data Continuity Mission (LDCM), a joint NASA and United States Geological Survey (USGS) mission, is scheduled for launch in December, 2012. The LDCM instrument payload will consist of the Operational Land Imager (OLI), provided by Ball Aerospace and Technology Corporation (BATC) under contract to NASA and the Thermal Infrared Sensor (TIRS), provided by NASA's Goddard Space Flight Center (GSFC). This paper will describe the design, capabilities and status of the OLI and TIRS instruments. The OLI will provide 8 channel multispectral images at a spatial resolution of 30 meters and panchromatic images at 15 meter spatial resolution. The TIRS is a 100 meter spatial resolution push-broom imager whose two spectral channels, centered at 10.8 and 12 microns, split the ETM+ thermal bands. The two channels allow the use of the "split-window" technique to aid in atmospheric correction. The TIRS focal plane consists of three Quantum Well Infrared Photodetector (QWIP) arrays to span the 185 km swath width. The OLI and TIRS instruments will be operated independently but in concert with each other. Data from both instruments will be merged into a single data stream at the (USGS)/Earth Resources Observation and Science (EROS) facility. The ground system, being developed by USGS, includes an Image Assessment System (lAS), similar to Landsat-7's, to operationally monitor, characterize and update the calibrations of the two sensors.

Reuter, Dennis↗

SiAl Composite Feedhorn Arrays for Astrophysical Applications: Cryogenic Material Properties

A study investigating the physical properties and use of the SiAl composite Controlled Expansion 7 (CE7) for the packaging of silicon bolometric detectors for millimeter-wave astrophysical applications at cryogenic temperatures is presented. The existing interfaces to such detectors are typically made of either ductile metals or micro-machined silicon. As a composite of Si and Al, we find that CE7 exhibits properties of both in ways that may be advantageous for this application. This exploration of the physical properties of CE7 reveals: (a) superconductivity below a critical transition temperature, T_c ∼ 1.2 K; (b) a thermal contraction profile much closer to Si than metal substrates; (c) the relatively low thermal conductivity anticipated for a superconductor, which can be improved by Au-plating; and (d) the feasibility of machining mechanical features with tolerances of ∼25 µm. We further discuss the use of CE7 in the cosmology large angular scale surveyor telescope array, which deployed CE7 in several of its detector focal planes.

Aamir M. Ali↗

Optical design concept of the CMB-S4 large-aperture telescopes and cameras

CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE Q/U IMAGING EXPERIMENT INSTRUMENT

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the cosmic microwave background, targeting the imprint of inflationary gravitational waves at large angular scales({approx}1 Degree-Sign ). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters that form the focal planes use a compact design based on high electron mobility transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01. The two arrays together cover multipoles in the range l {approx} 25-975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance, and sources of systematic error of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Kilopixel Pop-Up Bolometer Arrays for the Atacama Cosmology Telescope

The recently deployed Atacama Cosmology Telescope (ACT) anticipates first light on its kilopixel array of close-packed transition-edge-sensor bolometers in November of 2007. The instrument will represent a full implementation of the next-generation, large format arrays for millimeter wave astronomy that use superconducting electronics and detectors. Achieving the practical construction of such an array is a significant step toward producing advanced detector arrays for future SOFIA instruments. We review the design considerations for the detector array produced for the ACT instrument. The first light imager consists of 32 separately instrumented 32-channel pop-up bolometer arrays (to create a 32x32 filled array of mm-wave sensors). Each array is instrumented with a 32-channel bias resistor array, Nyquist filter array, and time-division SQUID multiplexer. Each component needed to be produced in relatively large quantities with suitable uniformity to meet tolerances for array operation. An optical design was chosen to maximize absorption at the focal plane while mitigating reflections and stray light. The pop-up geometry (previously implemented with semiconducting detectors and readout on the SHARC II and HAWC instruments) enabled straightforward interface of the superconducting bias and readout circuit with the 2D array of superconducting bolometers. The array construction program balanced fabrication challenges with assembly challenges to deliver the instrument in a timely fashion. We present some of the results of the array build and characterization of its performance.

Chervenak, J. A.↗

Optical Tweezers Array and Nimble Tweezers Probe Generated by Spatial- Light Modulator

An optical tweezers is being developed at the NASA Glenn Research Center as a visiblelight interface between ubiquitous laser technologies and the interrogation, visualization, manufacture, control, and energization of nanostructures such as silicon carbide (SiC) nanotubes. The tweezers uses one or more focused laser beams to hold micrometer-sized particles called tools (sometimes called tips in atomic-force-microscope terminology). A strongly focused laser beam has an associated light-pressure gradient that is strong enough to pull small particles to the focus, in spite of the oppositely directed scattering force; "optical tweezers" is the common term for this effect. The objective is to use the tools to create carefully shaped secondary traps to hold and assemble nanostructures that may contain from tens to hundreds of atoms. The interaction between a tool and the nanostructures is to be monitored optically as is done with scanning probe microscopes. One of the initial efforts has been to create, shape, and control multiple tweezers beams. To this end, a programmable spatial-light modulator (SLM) has been used to modify the phase of a laser beam at up to 480 by 480 points. One program creates multiple, independently controllable tweezer beams whose shapes can be tailored by making the SLM an adaptive mirror in an interferometer (ref. 1). The beams leave the SLM at different angles, and an optical Fourier transform maps these beams to different positions in the focal plane of a microscope objective. The following figure shows two arrays of multiple beams created in this manner. The patterns displayed above the beam array control the intensity-to-phase transformation required in programming the SLM. Three of the seven beams displayed can be used as independently controllable beams.

Decker, Arthur J.↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Prompt and delayed spectroscopy of {sup 199}At

The neutron-deficient nucleus {sup 199}At has been studied through {gamma}-ray and electron spectroscopy, using the recoil-decay tagging technique. Two experiments were conducted, using a gas-filled recoil separator with a focal-plane spectrometer alone and together with a germanium-detector array at the target position. The resulting level scheme for {sup 199}At includes a new isomer with a half-life of 0.80(5) {mu}s and a spin and parity of (29/2{sup +}). The 13/2{sup +} isomer, which de-excites via an M2 transition to the 9/2{sup -} ground state, was measured to have a half-life of 70(20) ns. Our earlier version of the level scheme for {sup 197}At has been updated as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IR area array status

Leading array technologies are defined and the status of HgCdTe hybrid focal plane development is reported. The liquid phase epitaxy system for HgCdTe production is also discussed.

Rode, J.↗

Evaluation of a far infrared Ge:Ga multiplexed detector array

The performance of a multielement Ge:Ga linear array under low-background conditions is investigated. On-focal plane switching is accomplished by MOSFET switches and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the responsivity was measured to be nominally 584 A/W, and the NEP was 1.0 x 10 exp -16 W/sq rt Hz. A detailed description of the test setup and the procedure is presented.

Farhoomand, Jam↗

The OMPS Limb Profiler Instrument: An Alternative Data Analysis and Retrieval Algorithm

The upcoming Ozone Mapper and Profiler Suite (OMPS), which will be launched on the NPOESS Preparatory Project (NPP) platform in early 2011, will continue monitoring the global distribution of the Earth's middle atmosphere ozone and aerosol. OMPS is composed of three instruments, namely the Total Column Mapper (heritage: TOMS, OMI), the Nadir Profiler (heritage: SBUV) and the Limb Profiler (heritage: SOLSE/LORE, OSIRIS, SCIAMACHY, SAGE III). The ultimate goal of the mission is to better understand and quantify the rate of stratospheric ozone recovery. The focus of the paper will be on the Limb Profiler (LP) instrument. The LP instrument will measure the Earth fs limb radiance (which is due to the scattering of solar photons by air molecules, aerosol and Earth surface) in the ultra-violet (UV), visible and near infrared, from 285 to 1000 nm. The LP simultaneously images the whole vertical extent of the Earth's limb through three vertical slits, each covering a vertical tangent height range of 100 km and each horizontally spaced by 250 km in the cross-track direction. The focal plane of the LP spectrometer is a two ]dimensional CCD array comprised of 340 x 740 pixels. Several data analysis tools are presently being constructed and tested to retrieve ozone and aerosol vertical distribution from limb radiance measurements. The primary NASA algorithm is based on earlier algorithms developed for the SOLSE/LORE and SAGE III limb scatter missions. The paper will describe an alternative algorithm which will retrieve ozone density and aerosol extinction directly from radiance data collected on individual CCD pixels. This alternative method uses an optimal estimation approach to retrieve ozone and aerosol in the 10-60 km range from the information contained within an ensemble of about 50000 down-linked pixels. Tangent height registration is performed using the Rayleigh Scattering Attitude Sensor (RSAS) technique applied to columns of pixels in the 340-360 nm range. Cloud height is determined by analyzing the radiance first derivative along pixel columns at longer wavelengths. Wavelength registration is performed using rows of pixels and identifying Fraunhofer solar lines within the measured spectra. Special attention is given to stray-light decontamination and modeling of the measured finite spectral/spatial line shape functions.

Rault, Didier F.↗