Search NASA⌕ Search

SEARCH · Search NASA

Results for “function as a service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Green Pricing Program Marketing Expenditures: Finding the Right Balance

In practice, it is difficult to determine the optimal amount to spend on marketing and administering a green pricing program. Budgets for marketing and administration of green pricing programs are a function of several factors: the region of the country; the size of the utility service area; the customer base and media markets encompassed within that service area; the point or stage in the lifespan of the program; and certainly, not least, the utility's commitment to and goals for the program. All of these factors vary significantly among programs. This report presents data on programs that have funded both marketing and program administration. The National Renewable Energy Laboratory (NREL) gathers the data annually from utility green pricing program managers. Programs reporting data to NREL spent a median of 18.8% of program revenues on marketing their programs in 2008 and 16.6% in 2007. The smallest utilities (those with less than 25,000 in their eligible customer base) spent 49% of revenues on marketing, significantly more than the overall median. This report addresses the role of renewable energy credit (REC) marketers and start-up costs--and the role of marketing, generally, in achieving program objectives, including expansion of renewable energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Networks and external sources of information, section 12

The basic functional aspects of telecommunications, text searching, and networking are reviewed. Some of the information services, both commercial and noncommercial, which are operational in the United States and Europe are described. The ARPANET, TELENET, TYMET, and EURONET packet networks are described. External online bibliographic data bases and factual data banks are reviewed. Details of services offered, specific topics available, and contact points are given for: (in the United States) the NASA/RECON, DOE/RECON, Defense RDT and E, Lockheed Information System (DIALOG), SDC ORBIT, and the bibliograhic Retrieval systems; and (in Europe), ESA/IRS, the International Atomic Energy Agency, TELESYSTEMS, SPIDEL, INKA DIMDI DATA-STAR, BLAISE, and PERGAMON-INFOLINE systems.

Eckert, P. F.↗

Satellite services system overview

The benefits of a satellite services system and the basic needs of the Space Transportation System to have improved satellite service capability are identified. Specific required servicing equipment are discussed in terms of their technology development status and their operative functions. Concepts include maneuverable television systems, extravehicular maneuvering unit, orbiter exterior lighting, satellite holding and positioning aid, fluid transfer equipment, end effectors for the remote manipulator system, teleoperator maneuvering system, and hand and power tools.

Rysavy, G.↗

The advanced tracking and data relay satellite system - The next generation

NASA is currently performing cost and feasibility studies for the next generation of TDRSS spacecraft. These spacecraft are needed to replenish the current generation of spacecraft and will be available in the 1997 time frame. The next generation of NASA satellites will perform tracking and data relay functions well into the next century. The challenge facing NASA is to provide new services in an evolutionary way without disrupting services provided to current users. Furthermore, these new services must be carefully coordinated with other similar international data relay activities to facilitate efficient and cost effective operation and to avoid interference. This orderly evolution requires careful planning and coordination. This paper describes the reference architecture and the new services under consideration by NASA including data rates and selected frequencies of operation. The paper also describes the planned implementation schedule and defines the evolutionary process from the current TDRSS system through the Space Station Freedom era and the implementation of the Advanced TDRSS.

Brandel, Daniel↗

Defense Technical Information Center (DTIC) - Its role in the USAF Scientific and Technical Information Program

The Defense Technical Information Center (DTIC), the central repository for DOD scientific and technical information concerning studies and research and engineering efforts, is discussed. The present makeup of DTIC is described and its functions in producing technical reports and technical report bibliographies are examined. DTIC's outreach services are reviewed, as are its DTIC information and technology transfer programs. DTIC's plans for the year 2000 and its relation to the mission of the U.S. Air Force, including the Air Force's STINFO program, are addressed.

Kuhn, Allan D.↗

NCCDS configuration management process improvement

By concentrating on defining and improving specific Configuration Management (CM) functions, processes, procedures, personnel selection/development, and tools, internal and external customers received improved CM services. Job performance within the section increased in both satisfaction and output. Participation in achieving major improvements has led to the delivery of consistent quality CM products as well as significant decreases in every measured CM metrics category.

Shay, Kathy↗

Applications of CCSDS recommendations to Integrated Ground Data Systems (IGDS)

This paper describes an application of the CCSDS Principle Network (CPH) service model to communications network elements of a postulated Integrated Ground Data System (IGDS). Functions are drawn principally from COSMICS (Cosmic Information and Control System), an integrated space control infrastructure, and the Earth Observing System Data and Information System (EOSDIS) Core System (ECS). From functional requirements, this paper derives a set of five communications network partitions which, taken together, support proposed space control infrastructures and data distribution systems. Our functional analysis indicates that the five network partitions derived in this paper should effectively interconnect the users, centers, processors, and other architectural elements of an IGDS. This paper illustrates a useful application of the CCSDS (Consultive Committee for Space Data Systems) Recommendations to ground data system development.

Mizuta, Hiroshi↗

Personnel Data Analysis and Retrieval of Phase 1 Move To LC-39 Area

As a technology major from Jackson State University (JSU) I was called in as a summer intern at Kennedy Space Center (KSC) to work in the NASA Engineering, Control and Data Systems (NE-C) Division supporting the Spaceport Command and Control System (SCCS) at the Space Station Processing Facility (SSPF). I was given a two-part project; the first consisted of lending support relocating SCCS Computer Equipment and Project Personnel to the Launch Control Center (LCC). This task involved me using a Microsoft Office data processing tool to assist with the analysis and information management of logistics worth millions of dollars. With the assistance of two other interns, I was responsible for collecting data on equipment used, on a daily basis, by over 200 KSC employees. The many network servers, enterprise switches, desktop computers, and fiber optics had to be handled in an equally prompt and precise manner in order to ensure a minimal amount of equipment down time; which is critical in ensuring a properly secured networking environment. The second part of my project was to assist KSC in developing a more cost effective way of maintaining and taking full advantage of the functionality of some new kiosk units. Since KSC currently has no expert on the servicing and maintenance of the units, I, as a computer technology major, was given the opportunity to assess the hardware and software of the machines. The goal was to learn to establish a secure and remote environment for the kiosks; a goal highly valuing convenience by preserving valuable man-hours saved by not having to travel to each individual kiosk location. In addition, I was to leave a clear and precise plan for future users and administrators of the devices to follow.

Davis, Derrick D.↗

"Giovanni at 20: Consistency and Persistency in Making Earth Remote Sensing Data Available (and Useful) to the Earth Science Community"

Since its creation in the year 2000, the NASA Geospatial Interactive Online Visualization ANd aNalysis Infrastructure (Giovanni) has been an exemplar of how to provide remotely-sensed satellite data and related Earth science datasets to a broad and globally diverse researcher community. One of the hallmarks of Giovanni system usage is that it is common to see practitioners of many branches of science – particularly those in fields not traditionally associated with remote-sensing data, such as animal behavior and paleooceanography – both accessing and employing datasets which the system provides. This usage pattern is attested to by the diversity of published science citing Giovanni. Giovanni has evolved through several versions, each of which increased analytical and visualization options while also enhancing ease-of-use. Information resources supporting Giovanni from the Goddard Earth Sciences Data and Information Services Center (GES DISC), which hosts the system, start with basic mapping and plotting functions and extend to “How-to” recipes demonstrating interusability with other data analysis systems and software. Giovanni is now being developed for use in a cloud environment, potentially expanding datasets the system can be applied to, and also improving performance for data having high spatial and temporal resolution. This presentation covers the system’s historical success with interesting examples of Giovanni-citing research, and will apply its current capabilities to a multi-dataset examination of derecho events associated with mesoscale convective phenomena in the summer of 2020, indicating how Giovanni is prepared for ongoing support of Earth science in a changing world.

Giovanni Derecho visualization↗

COMPARING UTILITY CONNECTED TO STAND ALONE MICRO-GRIDS: FROM THE VIEWPOINT OF A UTILITY ENGINEER

Project examples of grid connected micro grid & example of grid isolated micro grid: drivers – economic, environmental and financial tools to plan/design modeling software resource options, tools to plan/design generation types, fuel options and services to provide smooth transitions required equipment and software controls minimal expense to maximum functionality, real time operational interfaces, getting it built real world complications and advice. This paper is an attempt to present a broad overview of micro grids, project examples, modeling tools, technology options, practical and business insights to enable those interested in micro-grids to quickly come up to speed on the basics and potentially move forward on their own projects with the tools and resources presented. Knowledge and experience with electrical distribution systems will make such an effort easier.

energy storage↗

AP1000{sup R} design robustness against extreme external events - Seismic, flooding, and aircraft crash

Both the International Atomic Energy Agency (IAEA) and the U.S. Nuclear Regulatory Commission (NRC) require existing and new nuclear power plants to conduct plant assessments to demonstrate the unit's ability to withstand external hazards. The events that occurred at the Fukushima-Dai-ichi nuclear power station demonstrated the importance of designing a nuclear power plant with the ability to protect the plant against extreme external hazards. The innovative design of the AP1000{sup R} nuclear power plant provides unparalleled protection against catastrophic external events which can lead to extensive infrastructure damage and place the plant in an extended abnormal situation. The AP1000 plant is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. The plant's compact safety related footprint and protection provided by its robust nuclear island structures prevent significant damage to systems, structures, and components required to safely shutdown the plant and maintain core and spent fuel pool cooling and containment integrity following extreme external events. The AP1000 nuclear power plant has been extensively analyzed and reviewed to demonstrate that it's nuclear island design and plant layout provide protection against both design basis and extreme beyond design basis external hazards such as extreme seismic events, external flooding that exceeds the maximum probable flood limit, and malicious aircraft impact. The AP1000 nuclear power plant uses fail safe passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems (such as AC power, component cooling water, service water, compressed air or HVAC). The plant has been designed to protect systems, structures, and components critical to placing the reactor in a safe shutdown condition within the steel containment vessel which is further surrounded by a substantial 'steel concrete' composite shield building. The containment vessel is not affected by external flooding, and the shield building design provides hazard protection beyond that provided by a comparable reinforced concrete structure. The intent of this paper is to demonstrate the robustness of the AP1000 design against extreme events. The paper will focus on the plants ability to withstand extreme external events such as beyond design basis flooding, seismic events, and malicious aircraft impact. The paper will highlight the robustness of the AP1000 nuclear island design including the protection provided by the unique AP1000 composite shield building. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AP1000{sup R} nuclear power plant safety overview for spent fuel cooling

The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first level of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all possible pool heat load conditions. - After 3 days, several different means are provided to continue spent fuel cooling using installed plant equipment as well as off-site equipment with built-in connections. Even for beyond design basis accidents with postulated pool damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 multiple spent fuel pool spray and fill systems provide additional lines of defense to prevent spent fuel damage. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Space Ops 2002: Bringing Space Operations into the 21st Century. Track 3: Operations, Mission Planning and Control. 2nd Generation Reusable Launch Vehicle-Concepts for Flight Operations

With the successful implementation of the International Space Station (ISS), the National Aeronautics and Space Administration (NASA) enters a new era of opportunity for scientific research. The ISS provides a working laboratory in space, with tremendous capabilities for scientific research. Utilization of these capabilities requires a launch system capable of routinely transporting crew and logistics to/from the ISS, as well as supporting ISS assembly and maintenance tasks. The Space Shuttle serves as NASA's launch system for performing these functions. The Space Shuttle also serves as NASA's launch system for supporting other science and servicing missions that require a human presence in space. The Space Shuttle provides proof that reusable launch vehicles are technically and physically implementable. However, a couple of problems faced by NASA are the prohibitive cost of operating and maintaining the Space Shuttle and its relative inability to support high launch rates. The 2nd Generation Reusable Launch Vehicle (2nd Gen RLV) is NASA's solution to this problem. The 2nd Gen RLV will provide a robust launch system with increased safety, improved reliability and performance, and less cost. The improved performance and reduced costs of the 2nd Gen RLV will free up resources currently spent on launch services. These resource savings can then be applied to scientific research, which in turn can be supported by the higher launch rate capability of the 2nd Gen RLV. The result is a win - win situation for science and NASA. While meeting NASA's needs, the 2nd Gen RLV also provides the United States aerospace industry with a commercially viable launch capability. One of the keys to achieving the goals of the 2nd Gen RLV is to develop and implement new technologies and processes in the area of flight operations. NASA's experience in operating the Space Shuttle and the ISS has brought to light several areas where automation can be used to augment or eliminate functions performed by crew and ground controllers. This experience has also identified the need for new approaches to staffing and training for both crew and ground controllers. This paper provides a brief overview of the mission capabilities provided by the 2nd Gen RLV, a description of NASA's approach to developing the 2nd Gen RLV, a discussion of operations concepts, and a list of challenges to implementing those concepts.

Hagopian, Jeff↗

Design Function and Structure of a Monomeric CLC Transporter

Channels and transporters of the ClC family cause the transmembrane movement of inorganic anions in service of a variety of biological tasks, from the unusual - the generation of the kilowatt pulses with which electric fish stun their prey - to the quotidian - the acidification of endosomes, vacuoles and lysosomes. The homodimeric architecture of ClC proteins, initially inferred from single-molecule studies of an elasmobranch Cl{sup -} channel and later confirmed by crystal structures of bacterial Cl{sup -}/H{sup +} antiporters, is apparently universal. Moreover, the basic machinery that enables ion movement through these proteins - the aqueous pores for anion diffusion in the channels and the ion-coupling chambers that coordinate Cl{sup -} and H{sup +} antiport in the transporters - are contained wholly within each subunit of the homodimer. The near-normal function of a bacterial ClC transporter straitjacketed by covalent crosslinks across the dimer interface and the behaviour of a concatemeric human homologue argue that the transport cycle resides within each subunit and does not require rigid-body rearrangements between subunits. However, this evidence is only inferential, and because examples are known in which quaternary rearrangements of extramembrane ClC domains that contribute to dimerization modulate transport activity, we cannot declare as definitive a 'parallel-pathways picture in which the homodimer consists of two single-subunit transporters operating independently. A strong prediction of such a view is that it should in principle be possible to obtain a monomeric ClC. Here we exploit the known structure of a ClC Cl{sup -}/H{sup +} exchanger, ClC-ec1 from Escherichia coli, to design mutants that destabilize the dimer interface while preserving both the structure and the transport function of individual subunits. The results demonstrate that the ClC subunit alone is the basic functional unit for transport and that cross-subunit interaction is not required for Cl{sup -}/H{sup +} exchange in ClC transporters.

59 BASIC BIOLOGICAL SCIENCES↗

Stand and environmental conditions drive functional shifts associated with mesophication in eastern US forests

There is a growing body of evidence that mesic tree species are increasing in importance across much of the eastern US. This increase is often observed in tandem with a decrease in the abundance and importance of species considered to be better adapted to disturbance and drier conditions (e.g., Quercus species). Concern over this transition is related to several factors, including the potential that this transition is self-reinforcing (termed “mesophication”), will result in decreased resiliency of forests to a variety of disturbances, and may negatively impact ecosystem functioning, timber value, and wildlife habitat. Evidence for shifts in composition provide broad-scale support for mesophication, but we lack information on the fine-scale factors that drive the associated functional changes. Understanding this variability is particularly important as managers work to develop site-and condition-specific management practices to target stands or portions of the landscape where this transition is occurring or is likely to occur in the future. To address this knowledge gap and identify forests that are most susceptible to mesophication (which we evaluate as a functional shift to less drought or fire tolerant, or more shade tolerant, forests), we used data from the USDA Forest Service Forest Inventory and Analysis program to determine what fine-scale factors impact the rate (change through time) and degree (difference between the overstory and midstory) of change in eastern US forests. We found that mesophication varies along stand and environmental gradients, but this relationship depended on the functional trait examined. For example, shade and drought tolerance suggest mesophication is greatest at sites with more acidic soils, while fire tolerance suggests mesophication increases with soil pH. Mesophication was also generally more pronounced in older stands, stands with more variable diameters, and in wetter sites, but plots categorized as “hydric” were often highly variable. Our results provide evidence that stand-scale conditions impact current and potential future changes in trait conditions and composition across eastern US forests. We provide a starting point for managers looking to prioritize portions of the landscape most at risk and developing treatments to address the compositional and functional changes associated with mesophication.

Woodbridge, Margaret↗

Best Practices for Resilience Hub Development and Management

The Carbon League and its community partners in East St. Louis, Illinois, have identified five facilities to serve as resilience hubs. These hubs are intended to support the local community through a range of services and resources during blue-sky (everyday), gray-sky (pre-event), and black-sky (emergency) conditions. Transforming these facilities into fully functional resilience hubs requires a broad operational improvement and programmatic planning roadmap. This memo outlines best practices to guide the development of these resilience hubs in East St. Louis, including recommendations for infrastructure services; safety and physical protection; community services; operational protocols; and a phased implementation strategy aligned with realistic funding and capacity constraints. Infrastructure recommendations include strengthening electric power, communications, water, sanitation, and transportation/logistics capabilities, all of which are essential for hubs that may serve as cooling and warming centers, distribution points, and information hubs during emergencies. Safety recommendations focus on accessibility, emergency action planning, indoor air quality, and secure storage of critical equipment. A phased roadmap provides guidance from immediate, low-cost readiness actions to long-term optimization and community integration. Performance metrics and maintenance protocols ensure continuous improvement and operational readiness. This guidance draws on best practices that can be used to support the development of resilient, community-centered hubs capable of enhancing public safety, health, and well-being during everyday operations and emergencies alike.

99 GENERAL AND MISCELLANEOUS↗

Crack Growth Rate and Fracture Toughness Tests on Irradiated Ex-Plant Materials

The performance of structural materials is critical for the safe and economic operation of light water reactors. Exposed to neutron irradiation during service, the reactor core internal materials can undergo significant microstructural and microchemical changes, leading to irradiation hardening and embrittlement. To ensure the structural integrity and functionality of nuclear reactor components during long-term operation, material degradation and damage mechanisms must be understood and managed adequately. In this work, irradiated materials harvested from the decommissioned Zorita reactor were studied for their cracking susceptibility and fracture resistance as a function of irradiation dose up to 47 displacement per atom (dpa). The material is a Type 304 stainless steel sectioned from the baffle plates of this pressurized water reactor with 38 years of service. Crack growth rate and fracture toughness J-resistance (J-R) curve tests were performed in low-corrosion-potential environments at ~315°C. All samples behaved similarly under cyclic loading, and no deteriorated corrosion-fatigue behavior was observed in the test environments. Under constant stress intensity factors, most samples did not show elevated crack growth rates, suggesting an adequate stress corrosion cracking resistance in the test environments. However, an unstable cracking behavior was observed in a 47-dpa sample, resulting in significantly higher crack growth rates than expected at high stress intensity factors. Crack instability was also observed in a 0.06-dpa sample but did not lead to a sustained high crack growth rate. The impact of neutron irradiation was more evident in the fracture toughness J-R curve tests. As the dose increased, the J-R curve declined considerably and became very shallow at high doses. A fully intergranular fracture morphology was also observed among the high-dose samples ruptured in an air atmosphere at room temperature. This brittle fracture mode in the absence of high temperature water environment confirmed a high degree of embrittlement of this material resulting from its service exposure to neutron irradiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗