Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

2024.03.13 Bushing Subcommittee presentation on Transformer Bushing Seismic Resilience: Design, Hazard, & Prevention Analysis [Slides]

Presents results from power grid simulations on synthetic grids that estimate the impact from power transformer failures due to earthquakes. In the best-case scenario, there is an 82.9% likelihood of load loss greater or equal to 51 MW. Methodologies are described as well as path forward to improving transformer resilience and, consequently, the resilience of the bulk power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of TRMM and Global Precipitation Climatology Project (GPCP) Precipitation Analyses

This paper describes recent results of using Tropical Rainfall Measuring Mission (TRMM) (launched in November 1997) information as the key calibration tool in a merged analysis on a 1 x 1' latitude/longitude monthly scale based on multiple satellite sources and raingauge analyses. The TRMM-based product is compared with the community-based Global Precipitation Climatology Project (GPCP) results. The long-term GPCP analysis is compared to the new TRMM-based analysis which uses the most accurate TRMM information to calibrate the estimates from the Special Sensor Microwave/Imager (SSM/I) and geosynchronous IR observations and merges those estimates together with the TRMM and gauge information to produce accurate rainfall estimates with the increased sampling provided by the combined satellite information. The comparison with TRMM results on a month-to-month basis should clarify the strengths and weaknesses of the long-term GPCP product in the tropics and point to how to improve the monitoring analysis. Preliminary results from the TRMM merged satellite analysis indicates fairly close agreement with the GPCP estimates. The GPCP analysis is done at 2.5 degree latitude/longitude resolution and interpolated to a 1 degree grid for comparison with the TRMM analysis. As expected the same features are evident in both panels, but there are subtle differences in the magnitudes. Focusing on the Pacific Ocean Inter-Tropical Convergence Zone (ITCZ) one can see the TRMM-based estimates having higher peak values and lower values in the ITCZ periphery. These attributes also show up in the statistics, where GPCP>TRMM at low values (below 10 mm/d) and TRMM>GPCP at high values (greater than 15 mm/d). The area in the Indian Ocean which shows consistently higher values of TRMM over GPCP needs to be examined carefully to determine if the lack of geosynchronous data has led to a difference in the two analyses. By the time of the meeting over a year of TRMM products will be available for comparison. Global tropical and regional values will be compared. Both products will be compared to TRMM validation site data over land and water. The results should begin to determine the use of the TRMM estimates in the evaluation of the GPCP analysis.

Adler, Robert F.↗

Exploratory Climate Data Visualization and Analysis Using DV3D and UVCDAT

Earth system scientists are being inundated by an explosion of data generated by ever-increasing resolution in both global models and remote sensors. Advanced tools for accessing, analyzing, and visualizing very large and complex climate data are required to maintain rapid progress in Earth system research. To meet this need, NASA, in collaboration with the Ultra-scale Visualization Climate Data Analysis Tools (UVCOAT) consortium, is developing exploratory climate data analysis and visualization tools which provide data analysis capabilities for the Earth System Grid (ESG). This paper describes DV3D, a UV-COAT package that enables exploratory analysis of climate simulation and observation datasets. OV3D provides user-friendly interfaces for visualization and analysis of climate data at a level appropriate for scientists. It features workflow inte rfaces, interactive 40 data exploration, hyperwall and stereo visualization, automated provenance generation, and parallel task execution. DV30's integration with CDAT's climate data management system (COMS) and other climate data analysis tools provides a wide range of high performance climate data analysis operations. DV3D expands the scientists' toolbox by incorporating a suite of rich new exploratory visualization and analysis methods for addressing the complexity of climate datasets.

Maxwell, Thomas↗

Visual Methods for Model and Grid Validation

This joint research interchange proposal allowed us to contribute in two directions that are of interest to NASA. These are: (a) data level comparative visualization of experimental and computational fluid flow, and (b) visualization tools for analysis of adaptively refined Cartesian grids.

Pang, Alex↗

Review of Challenges and Research Opportunities for Voltage Control in Smart Grids

In this report, we review the emerging challenges and research opportunities for voltage control in smart grids. For transmission grids, the voltage control for accommodating wind and solar power, fault-induced delayed voltage recovery (FIDVR), and measurement-based Th´evenin equivalent for voltage stability analysis are reviewed. For distribution grids, the impact of high penetration of distributed energy resources (DER) is analyzed, typical control strategies are reviewed, and the challenges for local inverter Volt-Var control is discussed. Furthermore, the motivation, state-of-art, and future directions of the coordination of transmission system operators (TSO) and distribution system operators (DSO) are also thoroughly discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Effect of Under-Resolved Grids on High Order Methods

There has been much discussion on verification and validation processes for establishing the credibility of CFD simulations. Since the early 1990s, many of the aeronautical and mechanical engineering related reference journals mandated that any accepted articles in numerical simulations (without known solutions to compared with) need to perform a minimum of one level of grid refinement and time step reduction. Due to the difficulty in analysis, the effect of under-resolved grids and the nonlinear behavior of available spatial discretizations, are scarcely discussed in the literature. Here, an under-resolved numerical simulation is one where the grid spacing being used is too coarse to resolve the smallest physically relevant scales of the chosen continuum governing equations that are of interest to the numerical modeler. With the advent of new developments in fourth-order or higher spatial schemes, it has become common to regard high order schemes as more accurate, reliable and require less grid points. The danger comes when one tries to perform computations with the coarsest grid possible while still hoping to maintain numerical results sufficiently accurate for complex flows, and especially, data-limited problems. On one hand, high order methods when applies to highly coupled multidimensional complex nonlinear problems might have different stability, convergence and reliability behavior than their well studied low order counterparts, especially for nonlinear schemes such as TVD, MUSCL with limiters, ENO, WENO and discrete Galerkin. On the other hand, high order methods involve more operation counts and systematic grid convergence study can be time consuming and prohibitively expansive. At the same time it is difficult to fully understand or categorize the different nonlinear behavior of finite discretizations, especially at the limits of under-resolution when different types of bifurcation phenomena might occur, depending on the combination of grid spacings, time steps, initial conditions and numerical treatments of boundary conditions.

Yee, H. C.↗

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

Impact of Transport Electrification Demand and Charging Schedules on Electricity Markets and Nuclear Generators

As the U.S. pursues deep decarbonization targets, electric vehicles (EVs) are likely to become a major driver of demand growth and a major determinant of daily demand patterns. This study analyzes a possible future ERCOT-like electricity grid, and examines the impact of different types of EV charging schedules on grid and market outcomes. This analysis demonstrates the significant impact of EV charging patterns on capacity expansion simulations. Even without EVs, the overall daily demand profile in a market can have significant impacts on prices and grid stability in that system, especially if non-dispatchable renewable generators (e.g. wind and solar) make up a significant fraction of the generation mix. EV demand will not necessarily follow this preexisting demand profile, so its daily trends may significantly change what generation portfolio would optimally serve the system. Furthermore, the effects of EV demand can alter the profitability of different types of units, by altering the frequency of market events like extreme-demand hours or zero-price hours. These effects are explored in this study. The EV demand levels were derived from MARKAL simulations of the West-South-Central North American Electric Reliability Corporation (NERC) region for the year 2050, using a carbon tax of $100/ton. The baseline MARKAL simulation forecasted that 23% of the region’s annual electricity demand in 2050 would be attributable to EVs, and broke out demand projections for EV and non-EV end-use in that year. To model lower EV penetration into the system, an additional case was explored which assumed that EVs only achieved 75% of the demand level projected by MARKAL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Dynamic Grid Impedance and Its Impacts on Harmonics and Stability of Inverter Based Resources Plant

Nowadays, a large number of inverter-based resources (IBRs) are integrated into the grid at a single connection point as an IBR plant. In this article, a virtual dynamic grid impedance concept is introduced to evaluate the harmonics and stability for grid integration of an IBR plant containing multiple IBRs. First, a detailed theoretical study is conducted to build a foundation of the virtual grid impedance concept, which is a dynamic impedance that changes with the number of IBRs added into an IBR plant. Then, based on the new virtual dynamic grid impedance concept, frequency spectrum analysis is performed to explore harmonic impact at the interconnection point for an IBR plant with IBRs having L, LC, and LCL filters, respectively. An electromagnetic transient (EMT) simulation model of a grid-connected IBR plant is developed to explore the harmonics and stability of the IBR plant connected to the grid as well as the reliable operation of IBRs within the plant from the novel virtual equivalent dynamic grid impedance point of view. Hardware experiments are conducted to validate the EMT simulation evaluation. The results show that the number of IBRs added into an IBR plant influences the grid impedance, i.e., grid strength, and the grid impedance variation has multiple impacts on the IBR plant and IBRs within the plant depending on the grid-connected filters of the IBRs.

grid impedance↗

[Space Weather Impact on the Electricity Market]

Forbes & St. Cyr (2004, hereafter "FISC") have provided evidence that the electricity market can be impacted by space weather. Our analysis indicated that the estimated market impact for PJM was 3.7 % or approximately $500 million dollars over the 19 month sample period. Kappenman has taken exception to this estimate and contends that we have exaggerated the magnitude of the problem that space weather poses to PJM. There are four specific issues: (1) he claims that we have ignored relevant literature; (2) he asserts that Dst is not an appropriate proxy for GICs in PJM; (3) he charges that our findings are inconsistent with the impact of the 17 September 2000 storm; and (4) he alleges that our discussion of October 2003 storms is misleading. In our article, we have explained our methodology, multivariate regression analysis, with a particular focus on how it compares to correlation analysis. We have also explained the limitations of our analysis. We noted that "...While the Dstlprice relationship was found to be robust, the precise estimate should be treated with a relatively high degree of caution given that econometric modeling is not an exact science as well as the fact that the measure of space weather may be a poor proxy for GICs" (paragraph 96). We have also noted that additional research using local magnetometer data are needed (paragraph 97). We did not claim that that our findings for PJM are representative of the impact of space weather on other power grids. On the contrary, we noted that ... "Only analysis of other power grids will tell. " (paragraph 97). Kappenman inaccurately asserts that we have indicated that our findings . . . "imply much higher total costs are likely across the US and elsewhere in the world." He also inaccurately asserts that we have claimed that " . . . Dst is the most suited proxy for GIC in the PJM grid.. ." Moreover, he inaccurately refers to our analysis as a correlation study that uses Dst as quasi-binary indicator.

SaintCyr, O. Chris↗

Error Estimates of the Ares I Computed Turbulent Ascent Longitudinal Aerodynamic Analysis

Numerical predictions of the longitudinal aerodynamic characteristics for the Ares I class of vehicles, along with the associated error estimate derived from an iterative convergence grid refinement, are presented. Computational results are based on an unstructured grid, Reynolds-averaged Navier-Stokes analysis. The validity of the approach to compute the associated error estimates, derived from a base grid to an extrapolated infinite-size grid, was first demonstrated on a sub-scaled wind tunnel model at representative ascent flow conditions for which the experimental data existed. Such analysis at the transonic flow conditions revealed a maximum deviation of about 23% between the computed longitudinal aerodynamic coefficients with the base grid and the measured data across the entire roll angles. This maximum deviation from the wind tunnel data was associated with the computed normal force coefficient at the transonic flow condition and was reduced to approximately 16% based on the infinite-size grid. However, all the computed aerodynamic coefficients with the base grid at the supersonic flow conditions showed a maximum deviation of only about 8% with that level being improved to approximately 5% for the infinite-size grid. The results and the error estimates based on the established procedure are also presented for the flight flow conditions.

Abdol-Hamid, Khaled S.↗

Sizing SiC Storage Inverters for Fast Grid Frequency Support

As wind and solar displace synchronous generators whose inertia stabilizes the AC grid frequency on fast time scales, it has been proposed to use energy storage systems (ESSs) to mitigate frequency transient events. Such events require a rapid surge of power from the ESS, but they occur only rarely. The high temperature tolerance of SiC MOSFETs and diodes presents an opportunity for innovative ESS inverter designs. Herein we investigate a SiC ESS inverter design such that the SiC device ratings are obeyed during mild frequency events but are exceeded during rare, major events, for a potentially more economical inverter design. In support of this proposal we present: 1. An analysis of four years of grid frequency events in the U.S. Western Interconnection. 2. A switch-level ESS inverter simulation using SiC devices with detailed loss estimates. 3. Thermal analysis of the SiC power modules during a worst-case frequency event, showing that the modules can likely withstand the brief overcurrent. This analysis supports the conclusion that it may be advantageous for economical designs (acknowledging the increased risks) to undersize the SiC switches when designing inverters to perform active power control for grid frequency support. Such a strategy may result in SiC-based designs being more competitive with less costly silicon IGBT-based designs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Water-Energy Issues for Nuclear Power with Industry Perspective

The water-energy nexus is a dynamic, ever evolving challenge involving technological changes, regulatory updates, economic constraints, environmental issues, and political attributes. This report expands on a previous report that gave an initial assessment of the water-energy nexus challenges facing the U.S. commercial industry. This follow-up report provides analysis and insights from stakeholder interviews focusing on the issues faced by the U.S. commercial nuclear energy industry within the water-energy nexus space. This report updates and expand the “Cooling Water Issues and Opportunities at U.S. Nuclear Power Plants” This report includes analysis on water withdrawal and consumption by operating nuclear reactors, evolving policy risks that could impact the operation of the existing commercial nuclear fleet, implications of water markets, trading and water rights, the changing energy grid, progressing environmental risks (including analysis on the possible impact of climate change on water availability and nuclear power plant performance), and opportunities to reduce water related risk. The feedback from the stakeholders’ interviews helps incorporate viewpoints from within the nuclear and related industry that can lack representation in other research areas, without constituting a comprehensive opinion survey. Stakeholders interviewed include nuclear power plants operators, water treatment providers, developers, and vendors of reactor technologies.

99 GENERAL AND MISCELLANEOUS↗

Evaluating the Grid Impact of Oregon Offshore Wind

This analysis used high resolution offshore wind data and a detailed production cost model of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios varied offshore wind penetrations and explored the differences of integrating offshore wind in the current grid and a potential future grid. This allowed us to determine how changes to the rest of the system and increasing penetrations of offshore wind affected our findings. We identified a number of key findings from the analysis, including that 2.6 GW of nameplate capacity offshore wind could be integrated into the Oregon power system with minimal curtailment due to transmission congestion or other factors. The range of system value provided by offshore wind ranges between $\$$65/MWh and $\$$85/MWh across the various scenarios considered. We also examined the influence offshore wind had on the trans-Cascade power flow, where we determined a strong correlation between offshore wind generation and reduction in flow across the Cascades. Finally, we also determined that offshore wind could serve between 84 - 93% of Coastal Oregon loads depending on the scenario.

17 WIND ENERGY↗

Analysis of Multi-Output Hybrid Energy Systems Interacting with the Grid: Application of Improved Price-Taker and Price-Maker Approaches to Nuclear-Hydrogen Systems

The growing recognition of the value of hydrogen as an energy intermediate in supporting future power systems with high shares of variable renewable energy has prompted many studies to quantify the economic potential of multi-output hybrid systems, which are one type of integrated energy systems (IES). Because of the complexity of modeling multiple sectors, these studies typically use simplified modeling approaches to capture the interactions between sectors. In this study, we explore the implications of alternative modeling approaches for nuclear-hydrogen IES focusing on a power system in the Midwest United States. We combine highly resolved capacity expansion and production cost modeling tools of the power system with a detailed hydrogen system optimization tool to determine the optimal electrolyzer and storage sizing and optimal operations of the nuclear-hydrogen hybrid resource across three future study years. We compare economic and operational outcomes across a spectrum of modeling approaches, including a non-hybridized base approach; a traditional price-taker approach that does not include the impact of hydrogen production on the electricity system; a power-system-focused price-maker approach that does not account for temporal hydrogen constraints; and two improved price-taker and price-maker approaches that each address the impact of revenue-optimal levels of electricity production on the resulting power system and temporal hydrogen constraints on the overall feasible solution. Results show how a traditional price-taker approach can overestimate the economic benefits of multi-output nuclear-hydrogen IES compared to our two improved approaches that estimate both hydrogen system constraints and power system interaction. We find that hydrogen output requirements and storage size limits are key drivers to overall operations and some economic outcomes. Under our assumed constant hydrogen output requirement, storage costs, test system, and modeling approaches, our results indicate that hybridization can provide a net benefit, but results are sensitive to the treatment of hydrogen revenues and electricity prices as impacted by the power system evolution.

capacity expansion modeling↗