Text File Display Program

LOOK program permits user to examine text file in pseudorandom access manner. Program provides user with way of rapidly examining contents of ASCII text file. LOOK opens text file for input only and accesses it in blockwise fashion. Handles text formatting and displays text lines on screen. User moves forward or backward in file by any number of lines or blocks. Provides ability to "scroll" text at various speeds in forward or backward directions.

Vavrus, J. L.↗

PHOTCAL: The IRAF photometric calibration package

The IRAF photmetric calibration package PHOTCAL is discussed. PHOTCAL is a set of tasks designed to derive the transformation from the instrumental photometric system to the standard photometric system, and apply the transformation to the observations. The PHOTCAL package contains tasks for: (1) creating and/or editing standard star catalogs and observations catalogs, (2) creating, checking and editing the configuration file which specifies the format of the standard star and observations catalogs and the form of the transformation equations, (3) solving the transformation equations interactively or non-iteractively using non-linear least squares fitting routines, and (4) applying the transformation to the observations. PHOTCAL standard star and observations catalogs are simple text files, whose columns are delimited by whitespace, and whose first column contains the star names. This format makes it relatively easy to interface the output of non-IRAF photometry programs as well as the output of the IRAF APPHOT and DAOPHOT photometry packages to PHOTCAL. PHOTCAL maintains a standard star catalog directory for the convenience of the user, but users can easily create their own standard star catalogs and/or define their own standard star catalog directory. Separate observations files produced by APPHOT, DAOPHOT or a user program containing data for stellar fields taken through different filters, can be combined into observations catalogs using one of the PHOTCAL preprocessor tasks. The input configuration file required by PHOTCAL is a text file, consisting of a series of instructions written by the user in a mini-language understood by the PHOTCAL parser. These instructions: (1) assign names to the input data columns in the standard star and observations catalogs, (2) assign names and initial values to the parameters to be fit, (3) define and describe how to solve the transformation equations. The mini-language approach permits great flexibility in the format of the input catalogs and the form of the transformation equations.

Davis, L. E.↗

Multibody dynamics model building using graphical interfaces

In recent years, the extremely laborious task of manually deriving equations of motion for the simulation of multibody spacecraft dynamics has largely been eliminated. Instead, the dynamicist now works with commonly available general purpose dynamics simulation programs which generate the equations of motion either explicitly or implicitly via computer codes. The user interface to these programs has predominantly been via input data files, each with its own required format and peculiarities, causing errors and frustrations during program setup. Recent progress in a more natural method of data input for dynamics programs: the graphical interface, is described.

Macala, Glenn A.↗

Meteorological and hydrological parameters for 17 locations of meteorological stations of the East River Watershed

The Data Package includes a set of csv files of input meteorological parameters for locations of 17 meteorological stations within the East River watershed. These meteorological datasets were downloaded from the (1) PRISM database--monthly precipitation, air temperature (minimum, mean, and maximum), vapor pressure deficit (minimum and maximum), and dewpoint temperature, and (2) NCEP/NCAR Reanalysis database – wind database. The datasets were used for calculations of the Potential Evapotranspiration (ETo), Actual Evapotranspiration (ET), Standard Precipitation Index (SPI) , Standard Evapotranspiration-Precipitation Index (SPEI) for the period from 1966 to 2021. The main research questions addressed are: the evaluation of the long-term temporal trends of climatic parameters, hierarchical clustering, and areal mapping/zonation of the East River watershed. Calculations were conducted in the Rstudio environment. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.The input datasets were downloaded from (a) PRISM database (the Northwest Alliance for Computational Science and Engineering at the Oregon State University), and (b) NCEP/NCAR Reanalysis database.

54 ENVIRONMENTAL SCIENCES↗

Salton Sea Geodatabase for Geothermal Exploration Artificial Intelligence

These files contain the geodatabases related to Salton Sea Geothermal Field. It includes all input and output files used with the Geothermal Exploration Artificial Intelligence. Input and output files are sorted into three categories: raw data, pre-processed data, and analysis (post-processed data). In each of these categories there are six additional types of raster catalogs which are titled Radar, SWIR, Thermal, Geophysics, Geology, and Wells. The files are used with the Geothermal Exploration Artificial Intelligence for the Salton Sea Geothermal Site to identify indicators of blind geothermal systems. The included zip file is a geodatabase to be used with ArcGIS and the tar file is an inclusive database that encompasses the inputs and outputs for the Salton Sea Geothermal Site.

15 GEOTHERMAL ENERGY↗

Model Scripts for "Old-Aged Groundwater Contributes to Mountain Hillslope Hydrologic Dynamics"

The partitioning of water inputs between deep and shallow groundwater flow paths is a fundamental processes, yet is challenging to observe. Numerical models provide a valuable tool to further develop insights on these groundwater mixing processes. This repository contains scripts to run the ParFlow-CLM and EcoSLIM integrated hydrologic models along the Pumphouse Hillslope in the East River Watershed and associated python scripts to process model outputs. Files includes input decks for the associated models, python scripts, and text and css files to support the model runs and processing. The 2-D hillslope model simulates from 2000 to 2021 using transient forcing conditions from the publicly available NLDAS-2 dataset. We develop an ensemble of models with variable hydrogeologic and soil parameters. Model outputs from the ensemble of runs are compared to to water level observations at the PLM1 and PLM6 wells published at (https://data.ess-dive.lbl.gov/view/doi:10.15485/1866836) and groundwater mean ages published at (https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1960042. The model results are used to evaluate hillslope water mass-balance transience and mixing dynamics between groundwater flow paths with young (<10 year) and old (>10 year) ages.

54 ENVIRONMENTAL SCIENCES↗

Integrated Hourly Meteorological Database of 20 Meteorological Stations (1981-2022) for Watershed Function SFA Hydrological Modeling

This dataset contains (a) a script “R_met_integrated_for_modeling.R”, and (b) associated input CSV files: 3 CSV files per location to create a 5-variable integrated meteorological dataset file (air temperature, precipitation, wind speed, relative humidity, and solar radiation) for 19 meteorological stations and 1 location within Trail Creek from the modeling team within the East River Community Observatory as part of the Watershed Function Scientific Focus Area (SFA). As meteorological forcings varied across the watershed, a high-frequency database is needed to ensure consistency in the data analysis and modeling. We evaluated several data sources, including gridded meteorological products and field data from meteorological stations. We determined that our modeling efforts required multiple data sources to meet all their needs. As output, this dataset contains (c) a single CSV data file (*_1981-2022.csv) for each location (20 CSV output files total) containing hourly time series data for 1981 to 2022 and (d) five PNG files of time series and density plots for each variable per location (100 PNG files). Detailed location metadata is contained within the Integrated_Met_Database_Locations.csv file for each point location included within this dataset, obtained from Varadharajan et al., 2023 doi:10.15485/1660962. This dataset also includes (e) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and (f) a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type. Review the (g) ReadMe_Integrated_Met_Database.pdf file for additional details on the script, methods, and structure of the dataset.The script integrates Northwest Alliance for Computational Science and Engineering’s PRISM gridded data product, National Oceanic and Atmospheric Administration’s NCEP-NCAR Reanalysis 1 gridded data product (through the `RCNEP` R package, Kemp et al., doi:10.32614/CRAN.package.RNCEP), and analytical-based calculations. Further, this script downscales the input data into hourly frequency, which is necessary for the modeling efforts.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

The 4-D guidance of STOL aircraft in the terminal area

Advanced STOL aircraft for the improvement of the nation's air transportation system by the elimination of delays and congestions associated with today's air travel are discussed. A new guidance technique, referred to as 4-D guidance, is being developed for STOL aircraft. The 4-D guidance technique synthesizes complex three-dimensional flight paths from a minimum set of input and files the aircraft along the paths according to a prespecified time schedule. The two major elements of a 4-D guidance system are the trajectory synthesizer and the control law. Inputs to the trajectory synthesizer are the three-dimensional coordinates of way points, the turning radii, the speed ranges, the acceleration limits, and the arrival times at time control way points. First, the three-dimensional trajectory is computed by using circular arcs and straight lines. Then the airspeed profile, compensated for wind, is calculated to achieve the desired arrival times. The synthesized trajectory is stored as a time sequence of reference states which the aircraft is forced to track by using a linear feedback law.

Pecsvaradi, T.↗

Timeline Resource Analysis Program (TRAP): User's manual and program document

The Timeline Resource Analysis Program (TRAP), developed for scheduling and timelining problems, is described. Given an activity network, TRAP generates timeline plots, resource histograms, and tabular summaries of the network, schedules, and resource levels. It is written in ANSI FORTRAN for the Honeywell SIGMA 5 computer and operates in the interactive mode using the TEKTRONIX 4014-1 graphics terminal. The input network file may be a standard SIGMA 5 file or one generated using the Interactive Graphics Design System. The timeline plots can be displayed in two orderings: according to the sequence in which the tasks were read on input, and a waterfall sequence in which the tasks are ordered by start time. The input order is especially meaningful when the network consists of several interacting subnetworks. The waterfall sequence is helpful in assessing the project status at any point in time.

Sessler, J. G.↗

MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

TFaNS-Tone Fan Noise Design/Prediction System: Users' Manual TFaNS Version 1.5

TFaNS is the Tone Fan Noise Design/Prediction System developed by Pratt & Whitney under contract to NASA Glenn. The purpose of this system is to predict tone noise emanating from a fan stage including the effects of reflection and transmission by the rotor and stator and by the duct inlet and nozzle. The first version of this design system was developed under a previous NASA contract. Several improvements have been made to TFaNS. This users' manual shows how to run this new system. TFaNS consists of the codes that compute the acoustic properties (reflection and transmission coefficients) of the various elements and writes them to files, CUP3D Fan Noise Coupling Code that reads these files, solves the coupling problem, and outputs the desired noise predictions, and AWAKEN CFD/Measured Wake Postprocessor which reformats CFD wake predictions and/or measured wake data so they can be used by the system. This report provides information on code input and file structure essential for potential users of TFaNS.

Topol, David A.↗

TFaNS Tone Fan Noise Design/Prediction System: User's Manual - Volume 2

TFaNS is the Tone Fan Noise Design/Prediction System developed by Pratt & Whitney under contract to NASA Lewis (presently NASA Glenn). The purpose of this system is to predict tone noise emanating from a fan stage including the effects of reflection and transmission by the rotor and stator and by the duct inlet and nozzle. These effects have been added to an existing annular duct/isolated stator noise prediction capability. TFaNS consists of: the codes that compute the acoustic properties (reflection and transmission coefficients) of the various elements and write them to files. CUP3D: Fan Noise Coupling Code that reads these files, solves the coupling problem, and outputs the desired noise predictions. AWAKEN: CFD/Measured Wake Postprocessor which reformats CFD wake predictions and/or measured wake data so it can be used by the system. This volume of the report provides information on code input and file structure essential for potential users of TFANS. This report is divided into three volumes: Volume 1. System Description, CUP3D Technical Documentation, and Manual for Code Developers; Volume 2. User's Manual, TFANS Vers. 1.4; Volume 3. Evaluation of System Codes.

Topol, David A.↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WaterTAP-REFLO models of Solar Still, Solar Still ZLD, Enhanced Evaporation pond results for baseline analysis

This folder contains results from models that were adapted into WaterTAP-REFLO. The files contain inputs and outputs for solar still, solar still ZLD, and enhanced evaporation pond unit process models for 4 different locations in the USA: Phoenix, Miami, Houston, and Baltimore. The WaterTAP-REFLO implementation may be different and thus may have different results. The data structure and content are described in a ReadMe.txt file. For WaterTAP-REFLO documentation and/or contact the developers please see: https://github.com/watertap-org/watertap-reflo.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Features of the NEQAIR Radiation Code

The longest-lived code for predicting shock layer radiation, NEQAIR, is now in its 5th decade of service. Substantial changes to the code have been made over the previous decade, the most recent report of which was at the 5th Workshop on Radiation in High Temperature Gases in 2014, for the version referred to as NEQAIR14. This paper will review some of the improvements made to the NEQAIR code since then, which is now at v15.2. Some of these features are discussed briefly below. NEQAIR15 and subsequent versions have enabled parallel evaluation of multiple lines of sight. This is accomplished by utilizing the HDF5 file format and placing multiple lines into a single file, LOS.h5, which is used for both input and output. This approach enables straightforward parallel execution both over the number of lines of sight and the number of points per line. For large problems, runtime reduces linearly with the number of nodes deployed since each line is processed independently by a subset of MPI ranks. Three applications of the multi-line solver are discussed. The first has to do with performing loosely coupled radiation-flowfield solutions. In this case the computed absorption and emission coefficients are used to evaluate the total energy absorbed or emitted at each point, allowing evaluation of the volumetric source term in the flowfield. The second computation is for obtaining heat flux from nonuniform flows, which require integration over spherical co-ordinates. These are of particular interest for evaluating radiation on the vehicle backshell. This 3D option improves the angular integration scheme and allows adaptive line selection that together reduce the number of lines required by about an order of magnitude. The final application is for remote observation, which is essentially the 3D integration problem over a small solid angle. For all three of these computations, data can be stored in the HDF5 file which allows a NEQAIR run to be restarted when it times out, or to add atmospheric absorption or instrument scan functions. An additional level of parallelism is enabled in NEQAIR15.2 using GPU routines. The GPU parallelism has realized up to 8x speed-up when running on a single core but diminishes as CPU parallelism is increased. For running multi-line simulations, it may be easier to reserve a large number of CPU nodes than to obtain the number of GPU nodes required for similar performance. A GUI, known as NEQTPY, allows for reading and creating input files, running NEQAIR, and displaying results. A significant feature of NEQTPY is the ability to perform spectral fits to data. The fits can operate on a single line spectrum (radiance vs. wavelength) or a 3D input file with multiple columns of data. Other new features include improved constants, additional species, more detailed non-Boltzmann modelling, advanced user controls, the ability to read and calculate spectra from HITRAN datafiles, photodissociation and photoionization cross-sections. A “fast” automatic grid option may reduce the size and time of spectral calculations while still maintaining good accuracy for total heat flux.

Brett A Cruden↗