Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Investigation of the initial and volume recombination losses in gamma versatile cylindrical ionization chamber VGIC developed for gamma ray dosimetry

A versatile Gamma ionization chambers are used for flow control in systems with gamma nuclear reactors and reprocessing plants in and monitoring atmosphere around these facilities, this in order to protect staff. In the Laboratory Detection and Measures (LDM) Division for Study and Development of Nuclear Instrumentation (DSDNI) of CRNB, we designed, developed and characterized a versatile gamma ionization chamber (VGIC) to study experimentally its characteristics according to the geometry of the electrodes, the volume and pressure of the filler gas for the design of a gamma sealed chamber. The tests were conducted under the IEC (International Electro-technical Commission). In this paper, we present the results obtained in the various nuclear tests for characterization and calibration that we have made on the ionization chamber gamma VGIC prototype developed at our Department. To do this, three irradiators were operated at the Laboratory Calibration (SSDL) of the Department of Medical Physics Nuclear Research Center of Algiers (CRNA). Irradiator intensive gamma ({sup 60}Co: 1.25 MeV), one medium intensity gamma ({sup 137}Cs: 0.662 MeV) and 3rd low intensity ({sup 60}Co). Saturation curves and linearity were identified and the operating range and the sensitivity of the chamber have been deducted. The (I,V) characteristics of the chamber filled, with argon gas at 3 bar (0.3 M pa) pressure, for gamma ray irradiator sources were studied. To do so, the chamber was irradiated with gamma rays using different numbers of gamma sources (i.e. Up to 5). The plateau region is reached above 200 V and the detector operating voltage is found to be 600 V. It is observed that in the plateau region the slope is constant with an increase in the exposure rate. The (1/I, 1/V) and (I, l/V{sup 2}) characteristic curves reveal the presence of the initial and volume recombination losses. The volume recombination losses are found to be smaller than the initial recombination losses. Finally, in order to strengthen our results, we performed in the same conditions, a comparative characterization with another ionization gamma chamber type reference LND 504 (USA). (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument - Paper 75

High-power laser interaction with targets in vacuum at high laser irradiance levels can generate plasma and, consequently, create ionizing radiation hazards. The theory for ionizing radiation generation from laser-plasma interaction is complicated. The basics of theory and phenomenology are available qualitatively. However, the ionizing radiation yields associated with laser-plasma interaction have not been well quantified. Based on the theoretical analysis and review of the published reports and measurement data, SLAC National Accelerator Laboratory (SLAC) developed an analytic model to estimate conservatively the electron temperature and photon radiation yield (Sv/J) of a laser pulse hitting a solid target at 1 m as a function of laser irradiance between 10{sup 15} and 10{sup 21} W/cm{sup 2}. Ionizing radiation measurements from high-intensity laser-induced plasma interactions on solid targets inside the Al-walled vacuum chamber of the LCLS MEC instrument at SLAC were conducted using passive and active detectors at irradiance between 3x10{sup 16} and 6x10{sup 17} W/cm{sup 2}. Each run of the more than 20 runs had a unique set of laser, optic and target conditions with laser pulses rastering over the target surface mainly perpendicularly at a fixed irradiance. Significant effort was made in characterizing the laser irradiance values for each configuration of laser, focusing mirror, and target; four irradiances with targets of Au foils and copper plate were found to produce good measurement results. Electron doses inside the target chamber were highly anisotropic and peaked at backward direction by several orders of magnitude. Photon doses outside the target chamber were nearly isotropic (a factor of ∼2 higher in backward direction). When considering the large uncertainties of the irradiance (a factor of 2-3) and the potential shielding effects from detectors and target chamber, the measured photon dose rates at 1 m (150 mJ and 10 Hz) outside the target chamber (when averaged over different types of detectors) were in good agreement (a factor of ∼3) with the calculated values of the SLAC model, except at 3.0x10{sup 16} W/cm{sup 2}, which has an electron temperature of only 14 keV. At 6x10{sup 17} W/cm{sup 2}, a low level of ∼0.1 mrem/h from fast neutrons was measured (at 1 m, 150 mJ and 10 Hz) with a neutron-to-photon dose ratio of 0.2%. This is equivalent to a neutron dose yield of 2.8x10{sup -8} mSv/J (to be compared to the LULI measurements of 1x10{sup -4} mSv/J at 3x10{sup 19} W/cm{sup 2}). Both active and passive types of detectors performed well and the dose results were consistent, which is the same as the dose measurements in the Titan laser facility. Active detectors were not affected by the electromagnetic pulses associated with the MEC laser system; this was different from the Titan radiation measurements, in which all active detectors failed to respond, likely due to the high EMP in the Titan's high laser intensity fields. (authors)

43 PARTICLE ACCELERATORS↗

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

Propagation of ultrashort laser pulses in optically ionized gases

Propagation of 800 nm, 120 fs laser pulses with intensities of 4x10{sup 16} W/cm{sup 2} in supersonic gas jets of N{sub 2} and H{sub 2} is studied using a shear-type interferometer. The plasma density distribution resulting from photoionization is resolved in space and time with simultaneously measured initial neutral density distribution. A distinct difference in laser beam propagation distance is observed when comparing propagation in jets of H{sub 2} and N{sub 2}. This is interpreted in terms of ionization induced refraction, which is stronger when electrons are produced from states of higher ionization potential. Three dimensional particle-in-cell simulations, based on directly solving the Maxwell-Lorentz system of equations, show the roles played by the forward Raman and ionization scattering instabilities, which further affect the propagation distance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced ionization of counter-rotating electrons via doorway states in ultrashort circularly polarized laser pulses

We have performed single-active-electron numerical calculations of neon- and argonlike atoms interacting with short, intense, circularly polarized laser pulses at wavelengths between 10 nm and 1000 nm. Our results reveal a surprisingly large change by a factor of about 100 in the ionization ratio of electrons in initial states counter-rotating with respect to the field over corotating electrons in the previously unexplored intermediate few-photon ionization regime. The physical mechanism behind this observation is related to resonant enhanced ionization via states close in energy to the initial states. These doorway states are accessible exclusively from the initial state for counter-rotating electrons within the respective wavelength regime. Furthermore, the results may open a new route for controlling the generation of spin-polarized electrons by ultrashort laser pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atmospheric Pressure Chemical Ionization Sources Used in The Detection of Explosives by Ion Mobility Spectrometry

Explosives detection is a necessary and wide spread field of research. From large shipping containers to airline luggage, numerous items are tested for explosives every day. In the area of trace explosives detection, ion mobility spectrometry (IMS) is the technique employed most often because it is a quick, simple, and accurate way to test many items in a short amount of time. Detection by IMS is based on the difference in drift times of product ions through the drift region of an IMS instrument. The product ions are created when the explosive compounds, introduced to the instrument, are chemically ionized through interactions with the reactant ions. The identity of the reactant ions determines the outcomes of the ionization process. This research investigated the reactant ions created by various ionization sources and looked into ways to manipulate the chemistry occurring in the sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass Spectrometry Imaging of Bio‐oligomer Polydispersity in Plant Tissues by Laser Desorption Ionization from Silicon Nanopost Arrays

Abstract Mass spectrometry imaging (MSI) enables simultaneous spatial mapping for diverse molecules in biological tissues. Matrix‐assisted laser desorption ionization (MALDI) mass spectrometry (MS) has been a mainstream MSI method for a wide range of biomolecules. However, MALDI‐MSI of biological homopolymers used for energy storage and molecular feedstock is limited by, e.g., preferential ionization for certain molecular classes. Matrix‐free nanophotonic ionization from silicon nanopost arrays (NAPAs) is an emerging laser desorption ionization (LDI) platform with ultra‐trace sensitivity and molecular imaging capabilities. Here, we show complementary analysis and MSI of polyhydroxybutyric acid (PHB), polyglutamic acid (PGA), and polysaccharide oligomers in soybean root nodule sections by NAPA‐LDI and MALDI. For PHB, number and weight average molar mass, polydispersity, and oligomer size distributions across the tissue section and in regions of interest were characterized by NAPA‐LDI‐MSI.

Samarah, Laith Z.↗

Integration of paper spray ionization high‐field asymmetric waveform ion mobility spectrometry for forensic applications

Rationale Paper spray ionization (PSI) is an attractive ambient ionization source for mass spectrometry (MS) since it allows the combination of surface sampling and ionization. The minimal sample preparation inherent in this approach greatly reduces the time needed for analysis. However, the ions generated from interfering compounds in the sample and the paper substrate may interfere with the analyte ions. Therefore, the integration of PSI with high‐field asymmetric ion mobility spectrometry (FAIMS) is of significant interest since it should reduce the background ions entering the mass analyzer without complicating the analysis or increasing analysis time. Here we demonstrate the integration of PSI with FAIMS/MS and its potential for analysis of samples of forensic interest. Methods In this work, the parameters that can influence the integration, including sampling and ionization by paper spray, the FAIMS separation of analytes from each other and background interferences, and the length of time that a usable signal can be observed for explosives on paper, were evaluated with the integrated system. Results In the negative ion analysis of 2,4,6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocine (HMX), and 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), amounts as low as 1 ng on paper were readily observed. The successful positive ion separation of a set of illicit drugs including heroin, methamphetamine, and cocaine was also achieved. In addition, the positive ion analysis of the chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP) was evaluated. Conclusions The integration of PSI‐FAIMS/MS was demonstrated for the analyses of explosives in negative ion mode and for illicit drugs and CW simulants in positive mode. Paper background ions that could interfere with these analyses were separated by FAIMS. The compensation voltage of an ion obtained by FAIMS provided an additional identification parameter to be combined with the mass spectrum for each analyte.

Tsai, Chia‐Wei↗

Multireference Equation-of-Motion Driven Similarity Renormalization Group: Theoretical Foundations and Applications to Ionized States

We present a formulation and implementation of an equation-of-motion (EOM) extension of the multireference driven similarity renormalization group (MR-DSRG) formalism for ionization potentials (IP-EOM-DSRG). The IP-EOM-DSRG formalism results in a Hermitian generalized eigenvalue problem, delivering accurate ionization potentials for strongly correlated systems. The EOM step scales as O(N 5 ) with the basis set size N, allowing for efficient calculation of spectroscopic properties, such as transition energies and intensities. The IP-EOM-DSRG formalism is combined with three truncation schemes of the parent MR-DSRG theory: an iterative nonperturbative method with up to two-body excitations [MR-LDSRG(2)] and second- and third-order perturbative approximations [DSRG-MRPT2/3]. We benchmark these variants by computing (1) the vertical valence ionization potentials of a series of small molecules at both equilibrium and stretched geometries; (2) the spectroscopic constants of several low-lying electronic states of the OH, CN, N 2 + , and CO + radicals; and (3) the binding curves of low-lying electronic states of the CN radical. A comparison with experimental data and theoretical results shows that all three IP-EOM-DSRG methods accurately reproduce the vertical ionization potentials and spectroscopic constants of these systems. Notably, the DSRG-MRPT3 and MR-LDSRG(2) versions outperform several state-of-the-art multireference methods of comparable or higher cost.

Hamiltonians↗

Efficient Intermolecular Energy Exchange and Soft-ionization of Water at Nanoplatelet Interfaces

X-ray, energetic photon and electron irradiation can ionize and electronically excite target atoms and molecules. These excitations undergo complicated relaxation and energy transfer processes that ultimately determine the manifold of system responses to the deposited excess energy. In weakly bound gas- and solution-phase samples, intermolecular Coulomb decay (ICD) and electron-transfer mediated decay (ETMD) can occur with neighboring atoms or molecules leading to efficient transfer of the excess energy to the surroundings. In ionic solids such as metal-oxides, intra- and inter-atomic Auger decay produces localized final states that lead to lattice damage and typically removal of cations from the substrate. The relative importance of Auger stimulated damage (ASD) versus ICD and ETMD in micro-solvated nanoparticle interfaces is not known. Though ASD is generally expected, essentially no lattice damage and very efficient ICD and ETMD resulting from ionization and electronic excitation of micro-solvated boehmite (AlOOH) nanoplatelets has been observed. Efficient energy transfer and soft ionization of interfacial molecules is likely a general phenomenon at gas-oxyhydroxide nanoparticle interfaces where the density of states of the ionized chemisorbed species significantly overlap the core hole states of the solid.

Jones, Brant M.↗

World’s strongest laser enables pressure-driven ionization

The degree of ionization inside giant planets and stars determines their material properties. In burning stars, ionization is controlled by temperature, whereas pressure-driven ionization is dominant in cooler objects. Finally, experiments creating the extreme conditions needed for pressure-driven ionization in the laboratory shed light on this complex process.

47 OTHER INSTRUMENTATION↗

Attosecond response of molecules to impulsive ionization

When matter interacts with energetic radiation it can undergo sudden, or impulsive, ionization. This process can drive chemical change and occurs widely in space and planetary atmospheres, yet its comprehensive description challenges our current theoretical and computational capabilities as it requires advanced treatment of electron correlation and nonadiabatic dynamics beyond the Born–Oppenheimer approximation. Here, in this study, we measure the response of the para-aminophenol molecule to sudden ionization. Using attosecond X-ray absorption spectroscopy, we resolve the ultrafast dynamics of the ionized molecule with atomic precision. A subfemtosecond decay corresponds to states undergoing non-radiative decay, whereas few-femtosecond oscillatory signatures are associated with electronic wavepacket motion in stable cation states that later couple to nuclear motion. We compare our measurement with state-of-the-art computational modelling, qualitatively reproducing the observed response across multiple timescales. These results provide a benchmark for computational models of sudden ionization and ultrafast charge motion in matter.

Driver, Taran [SLAC National Accelerator Laborator↗

Demonstration of cooling by the Muon Ionization Cooling Experiment

The use of accelerated beams of electrons, protons or ions has furthered the development of nearly every scientific discipline. However, high-energy muon beams of equivalent quality have not yet been delivered. Muon beams can be created through the decay of pions produced by the interaction of a proton beam with a target. Such ‘tertiary’ beams have much lower brightness than those created by accelerating electrons, protons or ions. High-brightness muon beams comparable to those produced by state-of-the-art electron, proton and ion accelerators could facilitate the study of lepton–antilepton collisions at extremely high energies and provide well characterized neutrino beams. Such muon beams could be realized using ionization cooling, which has been proposed to increase muon-beam brightness. Here we report the realization of ionization cooling, which was confirmed by the observation of an increased number of low-amplitude muons after passage of the muon beam through an absorber, as well as an increase in the corresponding phase-space density. The simulated performance of the ionization cooling system is consistent with the measured data, validating designs of the ionization cooling channel in which the cooling process is repeated to produce a substantial cooling effect. The results presented here are an important step towards achieving the muon-beam quality required to search for phenomena at energy scales beyond the reach of the Large Hadron Collider at a facility of equivalent or reduced footprint.

43 PARTICLE ACCELERATORS↗

Filming enhanced ionization in an ultrafast triatomic slingshot

Abstract Filming atomic motion within molecules is an active pursuit of molecular physics and quantum chemistry. A promising method is laser-induced Coulomb Explosion Imaging (CEI) where a laser pulse rapidly ionizes many electrons from a molecule, causing the remaining ions to undergo Coulomb repulsion. The ion momenta are used to reconstruct the molecular geometry which is tracked over time (i.e., filmed) by ionizing at an adjustable delay with respect to the start of interatomic motion. Results are distorted, however, by ultrafast motion during the ionizing pulse. We studied this effect in water and filmed the rapid “slingshot” motion that enhances ionization and distorts CEI results. Our investigation uncovered both the geometry and mechanism of the enhancement which may inform CEI experiments in many other polyatomic molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionization Study of Isomeric Molecules in Strong-field Laser Pulses

Through the use of the technique of time-of-flight mass spectroscopy, we obtain strong-field ionization yields for randomly oriented 1,2-dichloroethylene (1,2-DCE) (C 2 H 2 Cl 2 ) and 2-butene (C 4 H 8 ). Here, we are interested in studying the effect of conformal structure in strong-field ionization and, in particular, the role of molecular polarity. That is, we can perform strong-field ionization studies in polar vs non-polar molecules that have the same chemical composition. Here, we report our findings through the ionization yields and the ratio (trans/cis) of each stereoisomer pair as a function of intensity.

74 ATOMIC AND MOLECULAR PHYSICS↗

An approach toward quantification of organic compounds in complex environmental samples using high-resolution electrospray ionization mass spectrometry

Quantitative analysis of individual compounds in complex mixtures using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) is complicated by differences in the ionization efficiencies of analyte molecules in the mixture, resulting in signal suppression during ionization. However, the ability to obtain concentration estimates of compounds in an environmental sample is important for data interpretation and comparison. We introduce an approach for estimating mass concentrations of analytes observed in a multicomponent mixture by HR-ESI-MS, without prior separation. The approach relies on a calibration of the instrument using appropriate standards added to the mixture of studied analytes. An illustration of how the proposed calibration can be applied in practice is provided for aqueous extracts of isoprene photooxidation organic aerosol, with multifunctional organic acids standards. We show that the observed ion sensitivities in ESI-MS are positively correlated with the “adjusted mass,” defined as a product of the molecular mass and the H/C ratio in the molecule (adjusted mass = H/C x molecular mass). The correlation of the observed ESI sensitivity with adjusted mass is justified by considering trends of the physical and chemical properties of organic compounds that affect ionization in the positive ion mode, i.e., gas-phase basicity, polarizability, and molecular size.

Environmental Molecular Sciences Laboratory↗

Development and investigation of efficient resonance ionization mass spectrometry schemes of gadolinium

Resonance ionization mass spectrometry of gadolinium can be used for nuclear forensics and to further the understanding of stellar nucleosynthesis but has been used only a handful of times due to the high laser power required and interference from non-resonant ionization of molecules of other elements. Herein we present the development of two novel resonance ionization spectroscopy schemes for gadolinium that provide improvements in isotopic fractionation and ionization efficiency, respectively, opening new applications for gadolinium analysis. The schemes are demonstrated and compared in a mixed sample of gadolinium and neodymium.

and nuclear chemistry↗

Delving into the depths of NGC 3783 with XRISM V. Broad-band modelling of ionized outflows

The Seyfert 1 galaxy NGC 3783 hosts a multi-phase warm absorber (WA) that has been extensively studied in the X-ray band. High-resolution spectra from 2000−2001 revealed a complex outflow with multiple ionization and velocity components. Two decades later, new XMM-Newton and XRISM observations allow us to investigate the long-term evolution of these outflows. We performed joint spectral modelling of the XMM-Newton /RGS and XRISM/Resolve time-averaged spectra using the pion photoionization code within SPEX. We derived the ionization parameter, column density, turbulent velocity, and outflow velocity for each absorption component, and investigated their thermal stability and absorption measure distribution (AMD) to characterize the physical and dynamical properties of the WA in NGC 3783 in 2024. We compared these results with the 2000−2001 epoch to assess long-term variability, stability, and possible changes in the absorber population. We identify eight WA components spanning log ξ = 1.08 − 3.38 and outflow velocities of 480−1230 km s −1 . The ranges of column densities and turbulent velocities remain broadly consistent with the WAs from 2000−2001, but the earlier data contained more low-ionization, high-velocity components. The total column density of all the outflows in 2024 is 1.5 times larger than in 2000−2001, which means that it has been replenished by fresh material. The dominant unresolved transition array (UTA) absorber (component B3) has increased its column density by a factor of three while maintaining a similar ionization parameter. The WAs in NGC 3783 have undergone significant structural and dynamical evolution over the past 24 years.

79 ASTRONOMY AND ASTROPHYSICS↗