Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Atom Interferometry for Detection of Gravitational Waves: NASA Institute for Advanced Concepts (NIAC) - Phase 1 Final Report

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

Saif, Babak N.↗

Synchronization System for Next Generation Light Sources

An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

43 PARTICLE ACCELERATORS↗

A Laboratory Atom Interferometer Instrument

We have demonstrated a laboratory based, high bandwidth atom interferometer instrument and have performed an incipient gravity measurement with a fractional statistical uncertainty of ag/g = 4.4 x 10 -6 where g is the acceleration due to gravity. We have designed, constructed, and optimised numerous laser systems for this purpose, most notably a powerful Raman laser (12 W at 780 nm) which will allow large momentum transfer and large detuning interferometry to be carried out at high bandwidth for the first time. This experiment is a general purpose test bed for exploring the fundamental limitations of atom interferometer techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of frequency and time support for NASA systems

NASA has frequency and timing systems at many facilities and centers. Timing systems with specifications tighter than several microseconds are covered. These ground based systems support scientific experiments and spacecraft tracking for the following programs; NASA Satellite Laser Ranging (NSLR); Network Mission Operations Support (NMOS); Kennedy Space Center (KSC); Very Long Baseline Interferometry (VLBI); Tracking Data Relay Satellite System (TDRSS) Ground Terminal Network; and the Deep Space Network (DSN). Major equipment assemblies, specifications, performance, and requirements, both present and future, are presented.

Kuhnle, Paul F.↗

Talbot-Lau X-ray Phase-Contrast Research at Johns Hopkins

The Talbot-Lau (T-L) grating interferometer enables X-ray differential phase-contrast (DPC) imaging with low coherence conventional X-ray tubes, being thus attractive for medical and other applications. We studied several variations of the conventional T-L interferometer design. First, to extend the T-L method to high X-ray energy we developed a symmetric interferometer having gratings inclined at a glancing angle (GAI). This simple setup enables achieving high fringe contrast up to 80 kVp or more. The high GAI contrast in turn enabled demonstrating for the first time DPC-CT of soft tissues with clinically compatible X-ray dose and energy. Industrial and security applications of the GAI appear also possible. Further on, we studied high magnification T-L interferometry for electron density diagnostic in high energy density plasmas. High magnification refraction radiography with laser driven backlighters can help understand inertial confinement fusion experiments for instance. For plasma diagnostic using a single radiographic image we develop Moiré fringe deflectometry. We also extended the T-L method below 10 keV using membrane and free standing gratings. Lastly, we explored using grazing incidence micro-periodic mirrors instead of gratings in the T-L interferometers. These enable in principle achieving very small interferometer periods over a broad energy range, at the price of a narrow field of view in one dimension. The possibility of using these designs for DPC imaging of materials under extreme conditions will also be examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase imaging of irradiated foils at the OMEGA EP facility using phase-stepping X-ray Talbot–Lau deflectometry

Abstract Diagnosing the evolution of laser-generated high energy density (HED) systems is fundamental to develop a correct understanding of the behavior of matter under extreme conditions. Talbot–Lau interferometry constitutes a promising tool, since it permits simultaneous single-shot X-ray radiography and phase-contrast imaging of dense plasmas. We present the results of an experiment at OMEGA EP that aims to probe the ablation front of a laser-irradiated foil using a Talbot–Lau X-ray interferometer. A polystyrene (CH) foil was irradiated by a laser of 133 J, 1 ns and probed with 8 keV laser-produced backlighter radiation from Cu foils driven by a short-pulse laser (153 J, 11 ps). The ablation front interferograms were processed in combination with a set of reference images obtained ex situ using phase-stepping. We managed to obtain attenuation and phase-shift images of a laser-irradiated foil for electron densities above ${10}^{22}\;{\mathrm{cm}}^{-3}$ . These results showcase the capabilities of Talbot–Lau X-ray diagnostic methods to diagnose HED laser-generated plasmas through high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗

The Space Interferometry Mission (SIM): technology development progress and plans

Optical and infrared interferometry will open new vistas for astronomy over the next decade. Space based interferometers, operating unfettered by the Earth's atmosphere, will offer the greatest scientific payoff. They also present the greatest technological challenge: laser metrology systems must perform with sub-nanometer precision; mechanical vibrations must be controlled to nanometers requiring orders of magnitude distrubance rejection; a multitude of actuators and sensors must operate flawlessly and in concert.

interferometry metrology pointing control nanomete↗

Space-based astrometric optical interferometry with POINTS

POINTS, a dual space-based astrometric optical interferometer with nominal baseline length of 2 meters and measurement accuracy of 5 microarcseconds, which could be a powerful new multidisciplinary research tool is introduced. The instrument, including the laser gauges which are a central aspect of the instrument, are described. The design of the spacecraft, and the mission operations, including the bias determination and correction, are discussed. As a candidate for the Astrometric Interferometry Mission (AIM) mission, POINTS could open new areas of astrophysical research and change the nature of the questions being asked in some old areas. As a candidate for the TOPS-1 (Towards Other Planetary Systems) mission, it could be used to perform a definitive search for extra solar planetary systems, either finding and characterizing a large number of them or showing that they are far less numerous than now believed. POINTS, which is small, agile, and mechanically simple, would be the first of a new class of powerful instruments in space and would prove the technology for the larger members of that class to follow.

Reasenberg, R. D.↗

Solar-System Tests of Gravitational Theories

We are engaged in testing gravitational theory, primarily using observations of objects in the solar system and primarily on that scale. Our goal is either to detect departures from the standard model (general relativity) - if any exist within the level of sensitivity of our data - or to place tighter bounds on such departures. For this project, we have analyzed a combination of observational data with our model of the solar system, including mostly planetary radar ranging, lunar laser ranging, and spacecraft tracking, but also including both pulsar timing and pulsar very long base interferometry (VLBI) measurements. This year, we have extended our model of Earth nutation with adjustable correction terms at the principal frequencies. We also refined our model of tidal drag on the Moon's orbit. We believe these changes will make no substantial changes in the results, but we are now repeating the analysis of the whole set of data to verify that belief. Additional information is contained in the original extended abstract.

Shapiro, Irwin I.↗

NASA Tech Briefs, November 2003

Topics covered include: Computer Program Recognizes Patterns in Time-Series Data; Program for User-Friendly Management of Input and Output Data Sets; Noncoherent Tracking of a Source of a Data-Modulated Signal; Software for Acquiring Image Data for PIV; Detecting Edges in Images by Use of Fuzzy Reasoning; A Timer for Synchronous Digital Systems; Prototype Parts of a Digital Beam-Forming Wide-Band Receiver; High-Voltage Droplet Dispenser; Network Extender for MIL-STD-1553 Bus; MMIC HEMT Power Amplifier for 140 to 170 GHz; Piezoelectric Diffraction-Based Optical Switches; Numerical Modeling of Nanoelectronic Devices; Organizing Diverse, Distributed Project Information; Eigensolver for a Sparse, Large Hermitian Matrix; Modified Polar-Format Software for Processing SAR Data; e-Stars Template Builder; Software for Acoustic Rendering; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Prolonging Microgravity on Parabolic Airplane Flights; Device for Locking a Control Knob; Cable-Dispensing Cart; Foam Sensor Structures Would be Self-Deployable and Survive Hard Landings; Real-Gas Effects on Binary Mixing Layers; Earth-Space Link Attenuation Estimation via Ground Radar Kdp; Wedge Heat-Flux Indicators for Flash Thermography; Measuring Diffusion of Liquids by Common-Path Interferometry; Zero-Shear, Low-Disturbance Optical Delay Line; Whispering-Gallery Mode-Locked Lasers; Spatial Light Modulators as Optical Crossbar Switches; Update on EMD and Hilbert-Spectra Analysis of Time Series; Quad-Tree Visual-Calculus Analysis of Satellite Coverage; Dyakonov-Perel Effect on Spin Dephasing in n-Type GaAs; Update on Area Production in Mixing of Supercritical Fluids; and Quasi-Sun-Pointing of Spacecraft Using Radiation Pressure.

Source record↗

Investigation of acoustic radiation from supersonic turbulent jets by double-pulse holographic interferometry

A new experimental method was used to optically investigate the acoustic field radiated from supersonic jets. The method utilizes a pulse ruby laser to obtain double exposure holograms of the sound field of a supersonic jet. The jet remains on during both exposures thus eliminating the no-flow exposure. The time separation between the pulses can be varied depending on the spectral component of the radiation to be observed. Optical records were obtained for supersonic jets with exit Mach number 1.0, 1.5 and 2.0. It was found that high frequency acoustic radiation mainly originates from the regions near the nozzle exit, whereas the low frequency noise is generated from regions further downstream. These findings are consistent with the acoustic data obtained by other investigators.

Ozkul, A.↗

Anomalous dispersion in atomic line filters applied for spatial frequency detection

The anomalous dispersion of an atomic line filter near a resonant transition is exploited for full-field frequency measurements. The influence of the line shape function on the dispersion in atomic vapors near resonance and the possibilities to increase sensitivity are discussed. From the model-calculated absorption of iodine vapor at frequency-doubled Nd:YAG laser wavelengths, the corresponding refractive index is obtained through the Kramers-Kronig relations. Both variables are used to assess the performance of a iodine vapor cell as a dispersive element in an interferometric setup for Doppler frequency shift detection. With good agreement, the predicted sensitivity of the setup is compared to an experimental calibration. Observed discrepancies are attributed to the assumption of a Gaussian line shape in the absorption model. The full-field Doppler frequency measurement capacity of the technique is demonstrated in a rotating disk experiment, and the measurement performance is assessed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-shot characterization of single plasma mirror temporal contrast improvement

Here, we report on the setup and commissioning of a compact recollimating single plasma mirror (PM) for temporal contrast enhancement at the Draco 150 TW laser during laser-proton acceleration experiments. The temporal contrast with and without PM is characterized single-shot by means of self-referenced spectral interferometry with extended time excursion at unprecedented dynamic and temporal range. This allows for the first single-shot measurement of the PM trigger point, which is interesting for the quantitative investigation of the complex pre-plasma formation process at the surface of the target used for proton acceleration. As a demonstration of high contrast laser plasma interaction we present proton acceleration results with ultra-thin liquid crystal targets of ~ 1 μm down to 10 nm thickness. Focus scans of different target thicknesses show that highest proton energies are reached for the thinnest targets at best focus. This indicates that the contrast enhancement is effective such that the acceleration process is not limited by target pre-expansion induced by laser light preceding the main laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering-type scanning near-field optical microscopy with Akiyama piezo-probes

Recent developments of the scattering-type scanning near-field optical microscope at cryogenic temperatures (cryogenic s-SNOM or cryo-SNOM) have led to many breakthroughs in the studies of low energy excitations in quantum materials. However, the simultaneous demands on vibration isolation, low base temperature, precise nano-positioning, and optical access make the construction of a cryo-SNOM a daunting task. Adding to the overhead space required for a cryo-SNOM is the atomic force microscopy control, which predominantly utilizes a laser-based detection scheme for determining the cantilever tapping motion. In this work, we provide an alternative and straightforward route to performing s-SNOM using metal-coated Akiyama probes, where the cantilever tapping motion is detected through a piezoelectric signal. We show that the Akiyama-based cryo-SNOM attains high spatial resolution, good near-field contrast, and is able to perform imaging with a significantly more compact system compared to other cryo-SNOM implementations. Our results firmly establish the potential of s-SNOM based on self-sensing piezo-probes, which can easily accommodate far-infrared wavelengths and high magnetic fields in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental results from magnetized-jet experiments executed at the Jupiter Laser Facility

Recent experiments at the Jupiter Laser Facility investigated magnetization effects on collimated plasma jets. Laser-irradiated plastic-cone-targets produced collimated, millimeter-scale plasma flows as indicated by optical interferometry. Proton radiography of these jets showed no indication of strong, self-generated magnetic fields, suggesting a dominantly hydrodynamic collimating mechanism. Targets were placed in a custom-designed solenoid capable of generating field strengths up to 5 T. Proton radiographs of the well-characterized B-field, without a plasma jet, suggested an external source of trapped electrons that affects proton trajectories. The background magnetic field was aligned with the jet propagation direction, as is the case in many astrophysical systems. Optical interferometry showed that magnetization of the plasma results in disruption of the collimated flow and instead produces a hollow cavity. Furthermore, this result is a topic of ongoing investigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗