Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Feasibility study, software design, layout and simulation of a two-dimensional Fast Fourier Transform machine for use in optical array interferometry

The goal of this project was the feasibility study of a particular architecture of a digital signal processing machine operating in real time which could do in a pipeline fashion the computation of the fast Fourier transform (FFT) of a time-domain sampled complex digital data stream. The particular architecture makes use of simple identical processors (called inner product processors) in a linear organization called a systolic array. Through computer simulation the new architecture to compute the FFT with systolic arrays was proved to be viable, and computed the FFT correctly and with the predicted particulars of operation. Integrated circuits to compute the operations expected of the vital node of the systolic architecture were proven feasible, and even with a 2 micron VLSI technology can execute the required operations in the required time. Actual construction of the integrated circuits was successful in one variant (fixed point) and unsuccessful in the other (floating point).

Boriakoff, Valentin↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three dimensional metafilms with dual channel unit cells

Three-dimensional (3D) metafilms composed of periodic arrays of silicon unit cells containing single and multiple micrometer-scale vertical split ring resonators (SRRs) per unit cell were fabricated. In contrast to planar and stacked planar structures, these 3D metafilms have a thickness t ~λ d /4, allowing for classical thin film effects in the long wavelength limit. The infrared specular far-field scattering response was measured for metafilms containing one and two resonators per unit cell and compared to numerical simulations. Excellent agreement in the frequency region below the onset of diffractive scattering was obtained. For dense arrays of unit cells containing single SRRs, normally incident linearly polarized plane waves which do not excite a resonant response result in thin film interference fringes in the reflected spectra and are virtually indistinguishable from the scattering response of an undecorated array of unit cells. For the resonant linear polarization, the specular reflection for arrays is highly dependent on the SRR orientation on the vertical face for gap-up, gap-down, and gap-right orientations. For dense arrays of unit cells containing two SRRs per unit cell positioned on adjacent faces, the specular reflection spectra are slightly modified due to near-field coupling between the orthogonally oriented SRRs but otherwise exhibit reflection spectra largely representative of the corresponding single-SRR unit cell structures. Lastly, the ability to pack the unit cell with multiple inclusions which can be independently excited by choice of incident polarization suggests the construction of dual-channel films where the scattering response is selected by altering the incident polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of solar array voltage patterns on plasma power losses

The use of high-voltage solar arrays in space is discussed in connection with the draining of array power by currents flowing between exposed surfaces through the surrounding plasma. The possibility of reducing the power loss by arranging solar cell strings in repeated small-area modules to eliminate any large areas at high potentials is investigated. It is found that the difference in power loss between modular and linear patterned high-voltage arrays is fairly small. Although the use of modular patterns can reduce the effective mean potential by about 10%, for the type of configuration being considered there is also a 10% increase in sheath area, leading to only a few percent change in total power loss. It is concluded that plasma power loss should not be a primary consideration in designing the physical arrangement of high-voltage arrays.

Mandell, M. J.↗

High dynamic range measurement of spectral responsivity and linearity of a radiation thermometer using a super-continuum laser and LEDs

To realize the temperature scale above the freezing point of silver according to the definition of ITS-90, the dynamic range of the spectral responsivity is one of the most important factors which limit its uncertainty. When the residual spectral response at both side bands of a spectral band is not negligible, a significant uncertainty can be caused by a low dynamic range of the spectral responsivity measurement. In general, incandescent lamps are used to measure the spectral responsivity and the linearity. The dynamic range of the spectral responsivity measurement is often limited by a trade-off with the desired spectral resolution, which is less than 6 decades. Nonlinearity is another limiting fact of uncertainties of the temperature scale. Tungsten lamps have disadvantage in the nonlinearity measurements in terms of adjustability of radiance level and spectral selectivity. We report spectral responsivity measurements of which the measurable dynamic range is enhanced 50 times after replacing a QTH lamp with a super continuum laser. We also present a spectrally selected linearity measurement over a wide dynamic range using high-brightness light emitting diode arrays to observe a slight saturation of linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Topological Constraint Relaxation in Ring-Linear Polymer Blends

Polymers are an effective test bed for studying topological constraints in condensed matter due to a wide array of synthetically available chain topologies. When linear and ring polymers are blended together, emergent rheological properties are observed as the blend can be more viscous than either of the individual components. This emergent behavior arises since ring-linear blends can form long-lived topological constraints as the linear polymers thread the ring polymers. Here, in this work, we demonstrate how the Gauss linking integral can be used to efficiently evaluate the relaxation of topological constraints in ring-linear polymer blends. For majority-linear blends, the relaxation rate of topological constraints depends primarily on reptation of the linear polymers, resulting in the diffusive time τ d,R for rings of length N R blended with linear chains of length N l to scale as τ d,R ~ N$^2_R$N$^{3.4}_L$.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Fully Soft and Multifunctional Shape Sensing via Optical Waveguide Arrays

For soft bodies, surface deformation and pressure provide proprioceptive and exteroceptive information, including body configuration, body compliance, and external forces. We develop a sheet sensor with a fully soft sensing surface that provides surface shape reconstruction using optical waveguide arrays. The waveguides are fabricated to achieve a tunable linear response to bi‐directional bending curvature, and the waveguide arrays are configured to differentiate between ambiguous shapes. We characterize the waveguide performance, relating curvature sensitivity to the core's surface roughness. Synergy of waveguide responses reduces the number of sensing elements required and achieves damage resilience. Using waveguide sensitivity to pressure, we also demonstrate feasibility for exteroception. We demonstrate the multifunctional sensing capability by wrapping the sheet around an upper arm, showcasing joint motion and external force sensing. Integrated into or applied onto surfaces of robotic or living systems, this design can be implemented in applications such as virtual reality, teleoperation, physical therapy, and soft robotics.

Yu, Qifan [Department of Mechanical Engineering Ma↗

X-ray topography using the forward transmitted beam under multiple-beam diffraction conditions

X-ray topographs are taken for a sapphire wafer with the [0001] surface normal, as an example, by forward transmitted synchrotron x-ray beams combined with two-dimensional electronic arrays in the x-ray detector having a spatial resolution of 1 μm. They exhibit no shape deformation and no position shift of the dislocation lines on the topographs. Since the topography is performed under multiple-beam diffraction conditions, the topographic images of a single diffraction (two-wave approximation condition) or plural diffractions (six-wave approximation condition) can be recorded without large specimen position changes. As usual Lang topographs, it is possible to determine the Burgers vector of each dislocation line. Because of high parallelism of the incoming x-rays and linear sensitivity of the electronic arrays to the incident x-rays, the present technique can be used to visualize individual dislocations in single crystals of the dislocation density as high as 1 × 10{sup 5} cm{sup −2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Long Neglected Cycloidal Mass Analyzer

Cycloid mass spectrometers offer powerful advantages for isotope ratio measurements, including double focusing (mass and energy), linear mass dispersion over a large spatial area, and a small footprint. However, the linear cycloid has not been adopted as widely as other mass analyzer designs, in part because of challenges with utilizing common ion detectors such as electron multipliers and Faraday cups. Integration of a linear cycloid with a capacitive transimpedance amplifier detector arrays can overcome these challenges, resulting in a compact powerful mass spectrometer for precision isotope ratio measurements.

47 OTHER INSTRUMENTATION↗

Regression of exchangeable relational arrays

Relational arrays represent measures of association between pairs of actors, often in varied contexts or over time. Trade flows between countries, financial transactions between individuals, contact frequencies between school children in classrooms and dynamic protein-protein interactions are all examples of relational arrays. Elements of a relational array are often modelled as a linear function of observable covariates. Uncertainty estimates for regression coefficient estimators, and ideally the coefficient estimators themselves, must account for dependence between elements of the array, e.g., relations involving the same actor. Existing estimators of standard errors that recognize such relational dependence rely on estimating extremely complex, heterogeneous structure across actors. This paper develops a new class of parsimonious coefficient and standard error estimators for regressions of relational arrays. Here we leverage an exchangeability assumption to derive standard error estimators that pool information across actors, and are substantially more accurate than existing estimators in a variety of settings. This exchangeability assumption is pervasive in network and array models in the statistics literature, but not previously considered when adjusting for dependence in a regression setting with relational data. We demonstrate improvements in inference theoretically, via a simulation study, and by analysis of a dataset involving international trade.

97 MATHEMATICS AND COMPUTING↗

Multisource Rotating Shield Brachytherapy Apparatus for Prostate Cancer

Purpose: Our purpose is to present a novel multisource rotating shield brachytherapy (RSBT) apparatus for the simultaneous precise angular and linear positioning of partially shielded {sup 153}Gd brachytherapy sources in interstitial needles for the treatment of locally advanced prostate cancer. It is designed to lower the dose to nearby healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy techniques. Methods and Materials: Following needle implantation through the patient template, an angular drive mechanism is docked to the patient template. Each needle is coupled to a multisource afterloader catheter by a connector passing through a shaft. The shafts are rotated about their axes by translating a moving template between 2 stationary templates. The shafts' surfaces and moving template holes are helically threaded with the same pattern such that translation of the moving template causes simultaneous rotation of the shafts. The rotation of each shaft is mechanically transmitted to the catheter-source-shield combination, inside the needles, via several key-keyway pairs. The catheter angles are simultaneously incremented throughout treatment, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multisource afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a wire that controls catheter depth in a needle. Results: Treatment plans demonstrated that RSBT with the proposed apparatus reduced urethral D{sub 0.1cm{sup 3}} (the minimum dose delivered to the hottest 0.1cm{sup 3} of the urethra) below that of conventional high-dose-rate brachytherapy by 31% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with the proposed multisource RSBT apparatus by use of nineteen 62.4-GBq {sup 153}Gd sources was 122 minutes. Conclusions: The proposed RSBT delivery apparatus enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable time frame.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.

60 APPLIED LIFE SCIENCES↗

Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilayer Microstrip Slot And Dipole Array Antenna

Multilayer antenna structure contains interleaved linear subarrays of microstrip dipole and slot radiating antenna elements to provide compact, dual-band antenna. Structure also contains associated microstrip transmission lines, plus high-power amplifiers for transmission and low-noise amplifiers for reception. Overall function is to transmit in horizontal polarization at frequency of 29.634 GHz and receive in vertical polarization at 19.914 GHz, in direction 44 degrees from broadside to antenna. Antenna structure is part of apparatus described in "Steerable K/Ka-band Antenna for Land-Mobile Satellite Applications," NPO-18772.

Tulintseff, Ann N.↗

Imaging Polarized Dust Emission in Star Formation Regions with the OVRO MM Array

We present OVRO interferometric observations of linearly polarized emission from magnetically aligned dust grains which allow the magnetic field geometry in nearby star formation regions to be probed on scales ranging from 100 to 3000 AU. Current results include observations of the young stellar objects NGC1333/IRAS 4A, IRAS 16293-2422 and Orion IRc2-KL.

Akeson, Rachel↗

Parallel plate capacitor TiN KID array development for the Balloon Experiment for Galactic Infrared Science

The Balloon Experiment for Galactic Infrared Science (BEGINS) will map dust spectral energy distributions (SEDs) between 25 and 250 microns near high-mass star regions, characterizing the radiation fields and dust properties of a variety of stellar environments. To accomplish these goals, BEGINS will be outfitted with roughly 1,800 titanium nitride (TiN), superconducting kinetic inductance detectors (KIDs). A parallel plate capacitor KID design is used to achieve high pixel density arrays. A cryogenic, silicon-based, metal-mesh linear variable filter will define detector band passes across the KID array. Optical coupling to the filters and telescope will be accomplished using silicon microlenses. Here we present laboratory characterization of prototype BEGINS detector arrays, describe future array development plans, and describe the testbed used to characterize the arrays.

Nicholas F. Cothard↗

Dependence of the Element Patterns of HYDROSTAR on Mutual Coupling

HYDROSTAR is a hybrid synthesis radiometer, intended for spaceborne applications, which employs a real aperture (waveguide stick antenna) for resolution along track and employs aperture synthesis to obtain resolution across track. This L-band system is an extension of the successful aircraft prototype, the Electronically Steered Thinned Array Radiometer (ESTAR). A proof-of-concept, full size system was constructed (45 wavelength in the synthesis direction) and subjected to extensive antenna pattern and associated microwave component measurements in an outdoor antenna test facility. HYDROSTAR employs a thinned array of 16 elements each 5.8 inches long in the along track dimension and spanning 9.5 inches across track. Each element is a narrow-wall shunt slot array with 36 slots. The polarization is linear (along-track). In the across track dimension, the antennas are deployed in a minimum redundancy array which has 90 independent baselines spaced in integer multiples of half a wavelength. The closest spacings used are for the first three elements at each end, which are spaced by only one-half wavelength. This study was intended to assess how closely each of 16 stick element patterns compare with their nominal values (as an individual, isolated radiator), when installed in their intended composite thinned array configuration. Extensive pattern measurements of the 16 elements that constitute the HYDROSTAR antenna subsystem were conducted to observe their relative features along the synthesis plane. Data was also collected for the mutual coupling between pairs of selected antennas. All antenna patterns had features different from that of an isolated element indicating some level of interaction among neighboring radiators. Those elements which had nearest neighbors at least five wavelengths away were located near the middle of the array. Their radiation patterns displayed sonic small, symmetric ripple across their full azimuth range. The patterns of elements that lie within 2.5 wavelengths of their neighbors showed stronger and asymmetric features. These are believed to be caused by mutual coupling among these structures. Evidence for this was seen when an antenna position was displaced by 0.05 wavelengths, Its pattern and those of its near neighbors were seen to change. Displacement within the plane of the array were observed to have different effects than displacements out-of-plane. A program of data analysis and theoretical development is in progress to provide a physical interpretation of the properties of these antenna patterns and to develop methods which can optimize the performance of this synthetic aperture imaging system. This includes compensation for pattern asymmetries and element position perturbation.

Weissman, David E.↗