Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Influence of infrared illumination on the characteristics of CdZnTe detectors

Infrared (IR) radiation of proper wavelength deep penetrating inside the CdZnTe detector may interact with trapping centers and has a significant influence on the trapping-detrapping processes of charge carriers from traps, thereby influencing charge collection efficiency in the detector. We studied the effect of infrared (IR) illumination on the characteristics of planar and quasi-hemispherical CdZnTe detectors. These results show that the near bandgap IR illumination significantly affects the detectors characteristics. By selecting a wavelength and intensity of illumination, detectors spectrometric characteristics can be significantly improved. Improvement of spectrometric characteristics is due to better uniformity of charge collection on the detector volume, as evidenced by the improvement in the total absorption peak symmetry and shape of the output pulses. The degree of improvement is different for various detectors depending on the characteristics of source material used for detector fabrication and theirs dimensions. For example, a detector of sizes 10 x 10 x 5 mm{sup 3} with an initial energy resolution (FWHM) of 20.6 keV at 662 keV under IR illumination was improved up to 9.1 keV, but a detector of sizes 5 x 5 x 2.5 mm{sup 3} with an initial energy resolution (FWHM) of 7.1 keV can be improved up to 4.8 keV. The IR illumination with a properly chosen intensity improves spectrometric characteristic in a wide range of energies without any losses of registration effectiveness. IR Illumination was practically performed using conventional GaAlAs IR LEDs with different peak wavelengths of emitted radiation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Quasi-Static Method with Step Doubling Time Adaptation

The imminent restart of the Transient Reactor Testing Facility (TREAT) at Idaho National Laboratory (INL) has brought significant attention to the development of transient reactor modeling. TREAT was designed to subject fuels and other reactor components to various degrees of neutron pulses, from minor transients to accident scenario. Inherently, this task requires predicting pulse responses due to various control rod movements; which is a complicated endeavor. Originally, this was done using an iterative process of rod movements and measuring the resulting response. With the advances in computer modeling, the current goal, preceding the restart, is to use simulation to characterize responses before experiments take place. However, neutron transient modeling is extremely computationally expensive due to the required implicit time-stepping. Therefore, methods that mitigate computation time, with minimal detriment to accuracy, are highly desired. This paper will describe the improved quasi-static method (IQS), which hopes to decrease computation time significantly from traditional 'brute force' transient methods. IQS is a spatial kinetics method that involves factorizing the flux solution into time-dependent amplitude and space- and time-dependent shape. The impetus of the method is the assumption that shape is weakly time-dependent, so expensive space-dependent evaluations are only required on large time steps. While inexpensive amplitude evaluations are performed on much smaller time steps to retain accuracy. IQS has been tested extensively on kinetics benchmarks with constant time steps. However, to test it's viability for TREAT simulations, evaluating IQS's performance with time adaptation is required. The rest of this paper will briefly describe the derivation of IQS, the time adaptation technique used, and results from a kinetic benchmarks. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the Mass Resolution of Single Particle Mass Spectrometry Using Delayed Ion Extraction

A specific delayed ion extraction (DIE) technique, which combines a standard rectangular extraction pulse with an exponential pulse, was introduced for a single particle mass spectrometry (SPMS) instrument, and it can focus ions in a wide mass range and results in a mass resolution improvement for the mass range of the studied ions. The experimental results indicate that the average mass resolution for positive ions is about 1000 when the mass-to-charge ratio (m/z) is greater than 70, and for negative ions, when the m/z is greater than 70, the average resolution can reach 2000. The highest mass resolutions achieved so far are 1260 for positive ions and 2400 for negative ions for SPMS, which are very beneficial for mass peak interpretation and chemical compound identification. The primary applications for atmospheric particle measurements show that the high mass resolution of SPMS with the DIE technique is very beneficial for the analysis of carbon and metallic element containing particles, and {sup 39}K{sup +} with C{sub 3}H{sub 3}{sup +} and {sup 41}K{sup +} and C{sub 3}H{sub 5}{sup +} in organic particles were successfully differentiated using SPMS. The results indicate that SPMS with DIE technique can significantly ease mass peak interpretation and improve the mass assignment ability during analysis. Furthermore, existing SPMS instruments can be improved by a facile retrofitting process to implement the DIE technique. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and Study of Neutron-rich Nuclei Using the LICORNE Directional Neutron Source

We have recently successfully demonstrated a new technique for production and study of many of the most exotic neutron-rich nuclei at moderate spins. LICORNE, a newly developed directional inverse-kinematic fast neutron source at the IPN Orsay, was coupled to the MINIBALL high resolution γ-ray spectrometer to study nuclei the furthest from stability using the 238 U(n,f)reaction. This reaction and 232 Th(n,f)are the most neutron-rich fission production mechanisms achievable and can be used to simultaneously populate hundreds of neutron-rich nuclei up to spins of ≈ 16h. High selectivity in the experiment was achieved via tripleγ-ray coincidences and the use of a 400 ns period pulsed neutron beam,a technique which is unavailable to other population mechanisms such as 235 U(nth,f) and 252 Cf(SF). The pulsing allows time correlations to be exploited to separate delayedγrays from isomeric states in the hundreds of nuclei produced, which are then used to cleanly select a particular nucleus and its exotic binary partners. In the recent experiment, several physics cases are simultaneously addressed such as shape coexistence, the evolution of shell closures far from stability, and the spectroscopy of nuclei in the r-process path near N= 82. Overall, preliminary physics results on anomalies in the 238 U(n,f) fission yields and the structure of the 138 Te and100Sr nuclei will soon be published. A future project,ν-ball, to couple LICORNE with a hybrid escape-suppressed spectrometer to refine further the technique and achieve a large increase in the observational limit is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimated vapor pressure for WTP process streams

Design assumptions during the vacuum refill phase of the Pulsed Jet Mixers (PJMs) in the Hanford Waste Treatment and Immobilization Plant (WTP) equate the vapor pressure of all process streams to that of water when calculating the temperature at which the vacuum refill is reduced or eliminated. WTP design authority asked the authors to assess this assumption by performing calculations on proposed feed slurries to calculate the vapor pressure as a function of temperature. The vapor pressure was estimated for each WTP waste group. The vapor pressure suppression caused by dissolved solids is much greater than the increase caused by organic components such that the vapor pressure for all of the waste group compositions is less than that of pure water. The vapor pressure for each group at 145°F ranges from 81% to 98% of the vapor pressure of water. If desired, the PJM could be operated at higher temperatures for waste groups with high dissolved solids that suppress vapor pressure. The SO4 group with the highest vapor pressure suppression could be operated up to 153°F before reaching the same vapor pressure of water at 145°F. However, most groups would reach equivalent vapor pressure at 147 to 148°F. If any of these waste streams are diluted, the vapor pressure can exceed the vapor pressure of water at mass dilution ratios greater than 10, but the overall effect is less than 0.5%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. Results: The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. Conclusions: These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Editorial: Using high energy density plasmas for nuclear experiments relevant to nuclear astrophysics

Thermonuclear reaction rates and nuclear processes have traditionally been explored by means of accelerator experiments, which are difficult to execute at conditions relevant to nucleosynthesis. High energy density (HED) plasmas generated using lasers, such as the inertial confinement fusion (ICF) platform, more closely mimic astrophysical environments in several ways, including with thermal distributions of reacting ions as opposed to mono-energetic ions impinging on a cold target; stellar-relevant plasma temperatures and densities; and neutron flux densities not found anywhere else on earth. The most extreme conditions can currently be achieved at the National Ignition Facility (NIF) laser in the US, where densities of 10 3 g/cm 3 and neutron fluxes up to 5∙10 27 neutrons/cm/s have been demonstrated over a time period of a few tens of picoseconds. The HED platform is emerging as an interesting complement to accelerator experiments.

charged-particle-induced reactions↗

Dynamics of confined reactive water in Smectic clay-zeolite composites.

The dynamics of water confined to mesoporous regions in minerals such as swelling clays and zeolites is fundamental to a wide range of resource management issues impacting many processes on a global scale, including radioactive waste containment, desalination, and enhanced oil recovery. Large-scale atomic models of freely diffusing multilayer smectite particles at low hydration confined in a silicalite cage are used to investigate water dynamics in the composite environment with the ReaxFF reactive force field over a temperature range of 300 647 K. The reactive capability of the force field enabled a range of relevant surface chemistry to emerge, including acid/base equilibria in the interlayer calcium hydrates and silanol formation on the edges of the clay and inner surface of the zeolite housing. After annealing, the resulting clay models exhibit both mono- and bilayer hydration structures. Clay surface hydration redistributed markedly and yielded to silicalite water loading. We find that the absolute rates and temperature dependence of water dynamics compare well to neutron scattering data and pulse field gradient measures from relevant samples of Ca-montmorillonite and silicalite, respectively. Within an atomistic, reactive context, our results distinguish water dynamics in the interlayer Ca(OH)2 nH2O environment from water flowing over the clay surface, and from water diffusing within silicalite. We find that the diffusion of water when complexed to Ca hydrates is considerably slower than freely diffusing water over the clay surface, and the reduced mobility is well described by a difference in the Arrhenius pre-exponential factor rather than a change in activation energy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of local concentration of H{sub 2}O molecules and gas temperature in the process of hydrogen - oxygen gas mixture heating by means of linear and nonlinear laser spectroscopy

Employing the methods of linear absorption spectroscopy and nonlinear four-wave mixing spectroscopy using laserinduced gratings we have simultaneously measured the local concentrations of H{sub 2}O molecules and the gas temperature in the process of the H{sub 2} - O{sub 2} mixture heating. During the measurements of the deactivation rates of pulsed-laser excited singlet oxygen O{sub 2} (b {sup 1}{Sigma}{sup +}{sub g}) in collisions with H{sub 2} in the range 294 - 850 K, the joint use of the two methods made it possible to determine the degree of hydrogen oxidation at a given temperature. As the mixture is heated, H{sub 2}O molecules are formed by 'dark' reactions of H{sub 2} with O{sub 2} in the ground state. The experiments have shown that the measurements of tunable diode laser radiation absorption along an optical path through the inhomogeneously heated gas mixture in a cell allows high-accuracy determination of the local H{sub 2}O concentration in the O{sub 2} laser excitation volume, if the gas temperature in this volume is known. When studying the collisional deactivation of O{sub 2} (b {sup 1}{Sigma}{sup +}{sub g}) molecules, the necessary measurements of the local temperature can be implemented using laser-induced gratings, arising due to spatially periodic excitation of O{sub 2} (X{sup 3}{Sigma}{sup -}{sub g}) molecules to the b {sup 1}{Sigma}{sup +}{sub g} state by radiation of the pump laser of the four-wave mixing spectrometer. (laser spectroscopy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient Radiation-Induced Berkelium(III) and Californium(III) Redox Chemistry in Aqueous Solution

Despite the significant impact of radiation-induced redox reactions on the accessibility and lifetimes of actinide oxidation states, fundamental knowledge of aqueous actinide metal ion radiation chemistry is limited, especially for the late actinides. A quantitative understanding of these intrinsic radiation-induced processes is essential for investigating the fundamental properties of these actinides. We present here a picosecond electron pulse reaction kinetics study into the radiation-induced redox chemistry of trivalent berkelium (Bk(III)) and californium (Cf(III)) ions in acidic aqueous solutions at ambient temperature. New, and first of a kind, second-order rate coefficients are reported for the transient radical-induced reduction of Bk(III) and Cf(III) by the hydrated electron (eaq−) and hydrogen atom (H•), demonstrating significant reactivity (up to 1011M-1s-1) indicative of a preference of these metals to adopt divalent states. Additionally, we reportthe first-ever second-order rate coefficients for the transient radical-induced oxidation of these elements by reaction with hydroxyl (•OH) and nitrate (NO3•) radicals, which also exhibited fast reactivity (ca. 108 M-1s-1). Transient Cf(II), Cf(IV), and Bk(IV) absorption spectra are also reported. Overall, the presented data highlight the existence of rich, complex, intrinsic late actinide radiation-induced redox chemistry that has the potential to influence the findings of other areas of actinide science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-301: Spectral Comparison of the Xoft and Zeiss 50 KVp X-Ray Systems

Purpose: To compare x-ray spectra of the 50 kVp Xoft Axxent™ and Zeiss INTRABEAM™ x-ray sources after filtration by saline-filled balloons applicators or spherical polymer applicators, respectively. Methods: Measurements were made for 3.5, 4.0 and 5.0 cm diameter applicators using an AmpTek model XR-100T-CdTe cadmium telluride spectrometer with 100 μm diameter collimating aperture and model PX4 digital pulse processor. Spectra were then corrected for escape processes using AmpTek XRF-FP Escape software. Both Axxent and INTRABEAM sources were operated at 50 kV and 40 μA to eliminate pulse saturation. The balloon or spherical applicator was placed in a centering fixture in contact with the collimator cap. The distance through the collimator housing from the applicator surface to the spectrometer's beryllium entrance window was nominally 52mm. Approximately 500,000 counts were collected for each spectrum. Results: Measured spectra in all cases had a broad Bremsstrahlung continuum with subtle differences in characteristic low energy x-rays lines from the different materials used for the anode thin films and substrates. After corrections for escape events average energies were calculated for spectra emerging from applicators. The average energies were 28.2 ±0.3 keV, 29.0±0.7 keV, and 31.7±0.9 keV for the 3.5, 4.0 and 5.0 cm diameter applicators, respectively. Differences in average energies ranged from 2.0 to 5.6% for these diameters. The mean energies of the spectra are more dependent on balloon size than on the delivery system used. Conclusion: Energy spectra at the surfaces of 3.5, 4.0 and 5.0 cm diameter applicators were measured for the Axxent and INTRABEAM x-ray systems were using a Cd-Te spectrometer. The average energies of the two x-ray systems for comparable applicator sizes were within 5.6%, and as little as 0.6 keV difference for the smaller applicator size. Research sponsored by Xoft, a subsidiary of ICAD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term performance of engineered barriers for high-level waste repositories - 15358

The evolution of the engineered barrier system (EBS) of geological repositories for high-level radioactive waste (HLW) and spent fuel (SF) has been the subject of many national and international research programs during recent years. The emphasis of the research activities was on the elaboration of a detailed understanding of the complex coupled thermo-hydro-mechanical and -chemical (THM-C) processes, which are expected to evolve in the early post-closure period in the near field. From the perspective of radiological long-term safety, an in-depth understanding of these coupled processes is of great significance, because the evolution of the EBS during the early post-closure phase may have a non-negligible impact on the safety functions at later stages of the repository's lifetime. Process interactions during the re-saturation phase (heat pulse, gas generation, non-uniform water uptake from the host rock) could impair the homogeneity of the safety-relevant properties in the EBS (e.g. swelling pressure, hydraulic conductivity, diffusivity). The 7. Framework EURATOM PEBS project (long-term Performance of Engineered Barrier Systems) was initiated in 2010 and completed in March 2014. The project aimed at evaluating the sealing and barrier performance of clay-based EBS over time. The project approach included experiments, model development and consideration of the potential impact on long-term safety functions. The specific project aims were to: -deepen the understanding of the THM and THM-C evolution of the EBS system with time, - provide an enhanced quantitative basis for relating the evolutionary behavior to the safety functions, - clarify further the significance of residual uncertainties for long-term performance assessment. It can be concluded that uncertainties in process understanding occurring in the re-saturation period have been better constrained through PEBS studies, thus the uncertainties in the long-term performance of bentonite barriers have been reduced in some areas. Improvements are in the areas of evolution of materials properties and model development and testing at various scales. On-going in-situ experiments in underground research laboratories may play an important role in further confirming bentonite performance over periods of 10 - 20 years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CONVECTIVE-REACTIVE PROTON-{sup 12}C COMBUSTION IN SAKURAI'S OBJECT (V4334 SAGITTARII) AND IMPLICATIONS FOR THE EVOLUTION AND YIELDS FROM THE FIRST GENERATIONS OF STARS

Depending on mass and metallicity as well as evolutionary phase, stars occasionally experience convective-reactive nucleosynthesis episodes. We specifically investigate the situation when nucleosynthetically unprocessed, H-rich material is convectively mixed with an He-burning zone, for example in a convectively unstable shell on top of electron-degenerate cores in asymptotic giant branch stars, young white dwarfs, or X-ray bursting neutron stars. Such episodes are frequently encountered in stellar evolution models of stars of extremely low or zero metal content, such as the first stars. We have carried out detailed nucleosynthesis simulations based on stellar evolution models and informed by hydrodynamic simulations. We focus on the convective-reactive episode in the very late thermal pulse star Sakurai's object (V4334 Sagittarii). Asplund et al. determined the abundances of 28 elements, many of which are highly non-solar, ranging from H, He, and Li all the way to Ba and La, plus the C isotopic ratio. Our simulations show that the mixing evolution according to standard, one-dimensional stellar evolution models implies neutron densities in the He intershell ({approx}< few 10{sup 11} cm{sup -3}) that are too low to obtain a significant neutron capture nucleosynthesis on the heavy elements. We have carried out three-dimensional hydrodynamic He-shell flash convection simulations in 4{pi} geometry to study the entrainment of H-rich material. Guided by these simulations we assume that the ingestion process of H into the He-shell convection zone leads only after some delay time to a sufficient entropy barrier that splits the convection zone into the original one driven by He burning and a new one driven by the rapid burning of ingested H. By making such mixing assumptions that are motivated by our hydrodynamic simulations we obtain significantly higher neutron densities ({approx} few 10{sup 15} cm{sup -3}) and reproduce the key observed abundance trends found in Sakurai's object. These include an overproduction of Rb, Sr, and Y by about two orders of magnitude higher than the overproduction of Ba and La. Such a peculiar nucleosynthesis signature is impossible to obtain with the mixing predictions in our one-dimensional stellar evolution models. The simulated Li abundance and the isotopic ratio {sup 12}C/{sup 13}C are as well in agreement with observations. Details of the observed heavy element abundances can be used as a sensitive diagnostic tool for the neutron density, for the neutron exposure and, in general, for the physics of the convective-reactive phases in stellar evolution. For example, the high elemental ratio Sc/Ca and the high Sc production indicate high neutron densities. The diagnostic value of such abundance markers depends on uncertain nuclear physics input. We determine how our results depend on uncertainties of nuclear reaction rates, for example for the {sup 13}C({alpha}, n){sup 16}O reaction.

79 ASTRONOMY AND ASTROPHYSICS↗