Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Reduction of magnetic damping constant of FeCo films by rare-earth Gd doping

Magnetic damping constant (α) is one of the key parameters to determine the critical current density of spin-transfer-torque devices and the switching time of magnetization for ultra-high-frequency devices. In this work, Gd doped FeCo films were fabricated to investigate α based on the ferromagnetic resonance technique. Gd doping not only can efficiently decrease the magnetic inhomogeneity and the extrinsic part of α but also the Landé g-factor and intrinsic part of α. The obtained α was roughly proportional to (g-2){sup 2} and the magnetic anisotropic constant, indicating that the decreased spin-orbit interaction decreases α by Gd doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE DATA REDUCTION PIPELINE FOR THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT

The Apache Point Observatory Galactic Evolution Experiment (APOGEE), part of the Sloan Digital Sky Survey III, explores the stellar populations of the Milky Way using the Sloan 2.5-m telescope linked to a high resolution (R ∼ 22,500), near-infrared (1.51–1.70 μm) spectrograph with 300 optical fibers. For over 150,000 predominantly red giant branch stars that APOGEE targeted across the Galactic bulge, disks and halo, the collected high signal-to-noise ratio (>100 per half-resolution element) spectra provide accurate (∼0.1 km s{sup −1}) RVs, stellar atmospheric parameters, and precise (≲0.1 dex) chemical abundances for about 15 chemical species. Here we describe the basic APOGEE data reduction software that reduces multiple 3D raw data cubes into calibrated, well-sampled, combined 1D spectra, as implemented for the SDSS-III/APOGEE data releases (DR10, DR11 and DR12). The processing of the near-IR spectral data of APOGEE presents some challenges for reduction, including automated sky subtraction and telluric correction over a 3°-diameter field and the combination of spectrally dithered spectra. We also discuss areas for future improvement.

79 ASTRONOMY AND ASTROPHYSICS↗

Wearable Sensor Application for Integrated Early Warning and Health Surveillance

Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health using physiologic and environmental indicators. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and landscape data, and calculates the corresponding physiological strain index. The information is presented to the analyst in a group and individual view with real-time alerting of abnormal health parameters. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agency's Biosurveillance Ecosystem (BSVE).Introduction: Wearable devices are a low cost, minimally invasive way to monitor health. Sensor data provides real-time physiological indictors of an individual’s health status without the requirement of health care professionals or facilities. Information gleamed from wearable sensors can be used to better understand physiological stressors and prodromal symptoms. In addition, this data can be used to monitor individuals that are in high risk of health-related problems.However, raw data from wearable sensors can be overwhelming to process and laborious to monitor for an individual and, even more so, for a group of individuals. Often specific combination of ranges of sensor readings are indicative of changes to health status and need to be evaluated together or used to calculate specific signal parameters. In addition, the environment surrounding the individual needs to be considered when interpreting the data. To address these issues, PNNL has developed an application that collects, analyzes, and integrates wearable sensor data with geographic landscape and weather information to provide a real-time early alert and situational awareness tool for monitoring the health of groups and individuals.Methods: The prototype application described here was a product of PNNL’s BSVE Application Development Competition. The final product that will be deployed in the BSVE is currently under development by PNNL and will vary slightly in the exact design and architecture described.Data. Wearable sensor data was collected from the Rim2Rim (R2R) Watch Study of individuals hiking the Grand Canyon in Arizona [1]. Weather information was obtained from nearby weather stations and mapping features were derived from Google Maps.Calculations. A physiological Strain Index (PSI) was calculated using core temperature estimates derived through a Kalman Filter approach and heart rate [2,3].Application. The prototype backend application development was based in Python with a MongoDB. The front-end development was built using a scalable architecture and modular approach with components in React and D3.Results: A prototype application was developed this past summer through the PNNL BSVE App Competition (Fig 1). The application was aimed at visualizing wearable sensor data from the Grand Canyon R2R hike dataset. Simulated real-time analysis was used to calculate health status of individuals hiking based on measured physiological parameters and to alert to individuals with signs of physiologic health stress. Visualization tools were incorporated to enable sensor data for individuals and the group to be viewed simultaneously along with pertinent weather, geographic, and elevation data.Many features described in the prototype application will be incorporated into the final BSVE application. The key changes will be 1) the ability to select given time periods for viewing historical data as well as the real-time data collection, 2) environmental data and map view will come from BSVE internal data sources, and 3) the alerts will provide more information and have their own page for reviewing.Conclusions: The Wearable Sensor Application developed by PNNL for integration into the BSVE provides an early warning system for individual and group health using physiologic and environmental parameters. The application highlights health status from wearable sensors and relevant environmental parameters while monitoring a calculated physiological strain index. With this tool, an analyst can easily monitor the health of individuals and groups with the aid of real-time alerting tool for early detection of abnormal health parameters.

Early Warning↗

Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Viscous effects on the Rayleigh-Taylor instability with background temperature gradient

Here we studied the growth rate of the compressible Rayleigh-Taylor instability in the presence of a background temperature gradient, Θ, using a normal mode analysis. The effect of Θ variation is examined for three interface types corresponding to the combinations of the viscous properties of the fluids (inviscid-inviscid, viscous-viscous, and viscous-inviscid) at different Atwood numbers, At, and when at least one of the fluids' viscosity is non-zero, as a function of the Grashof number. For the general case, the resulting ordinary differential equations are solved numerically; however, dispersion relations for the growth rate are presented for several limiting cases. An analytical solution is found for the inviscid-inviscid interface and the corresponding dispersion equation for the growth rate is obtained in the limit of large Θ. For the viscous-inviscid case, a dispersion relation is derived in the incompressible limit and Θ=0. Compared to Θ=0 case, the role of Θ<0 (hotter light fluid) is destabilizing and becomes stabilizing when Θ>0 (colder light fluid). The most pronounced effect of Θ ≠ 0 is found at low At and/or at large perturbation wavelengths relative to the domain size for all interface types. On the other hand, at small perturbation wavelengths relative to the domain size, the growth rate for the Θ<0 case exceeds the infinite domain incompressible constant density result. The results are applied to two practical examples, using sets of parameters relevant to Inertial Confinement Fusion coasting stage and solar corona plumes. The role of viscosity on the growth rate reduction is discussed together with highlighting the range of wavenumbers most affected by viscosity. The viscous effects further increase in the presence of background temperature gradient, when the viscosity is temperature dependent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

Bifurcation theory of a one-dimensional transport model for the L-H transition

Transitions between low and high-confinement (L-H transitions) in magnetically confined plasmas can appear as three qualitatively different types: sharp, smooth, and oscillatory. Bifurcation analysis unravels these possible transition types and how they are situated in parameter space. In this paper the bifurcation analysis is applied to a 1-dimensional model for the radial transport of energy and density near the edge of magnetically confined plasmas. This phenomenological L-H transition model describes the reduction of the turbulent transport by E×B-flow shear self-consistently with the evolution of the radial electric field. Therewith, the exact parameter space, including the threshold values of the control parameters, of the possible L-H transitions in the model is determined. Furthermore, a generalised equal area rule is derived to describe the evolution of the transport barrier in space and time self-consistently. Applying this newly developed rule to the model analysed in this paper reveals a naturally occurring transition to an extra wide transport barrier that may correspond to the improved confinement known as the very-high-confinement mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of Possible Pathways for C–C Bond Formation during Electrochemical Reduction of CO 2 : New Theoretical Insights from an Improved Electrochemical Model

Here, we have carried out a periodic Kohn-Sham density functional theory investigation of the pathways by which carbon-carbon bonds could be formed during the electrochemical reduction of CO 2 on Cu(100) using a model that includes the effects of the electrochemical potential, solvent, and electrolyte. The electrochemical potential was set by relating the applied potential to the Fermi energy and then calculating the number of electrons required by the simulation cell for that specific Fermi energy. The solvent was included as a continuum dielectric, and the electrolyte was described using a linearized Poisson-Boltzmann model. The calculated potential of zero charge for a variety of surfaces agrees with experiment to within a mean average error of 0.09 V, thereby validating the assumptions of the model. Analysis of the mechanism for C–C bond formation revealed that at low-applied potential, C–C bond formation occurs through a CO dimer. However, at high applied potentials, a large activation barrier blocks this pathway; therefore, C–C bond formation occurs through reaction of adsorbed CHO and CO. Rate parameters determined from our calculations were used to simulate the kinetics of ethene formation during the electrochemical reduction of CO over a Cu(100) surface. An excellent match was observed between previously reported measurements of the partial current for ethene formation as a function of applied voltage and the variation in the partial current for C–C bond formation predicted by our microkinetic model. The electrochemical model reported here is simple, fairly easy to implement, and involves only a small increase in computational cost over calculations neglecting the effects of the electrolyte and the applied field. Therefore, it can be used to study the effects of applied potential and electrolyte composition on the energetics of surface reactions for a wide variety of electrochemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building and testing correlations for the estimation of one‐electron reduction potentials of a diverse set of organic molecules

We describe and evaluate a method for computationally predicting reduction potentials of a diverse group of organic molecules by linearly correlating calculated lowest unoccupied molecular orbital energies with ground state reduction potentials measured in acetonitrile. The approach is shown to provide a unique combination of extreme computational simplicity and excellent accuracy across a diverse range of organic structures and a wide window of reduction potentials. A disparate set of molecules (74 compounds belonging to six distinct structural families, comprised of molecules containing C, H, N, O, F, Cl, and Br, with functional groups including esters, ketones, halides, nitriles, quinones, alkenes, arenes, heteroarenes, and pyridinium and higher benzologs, all containing conjugated pi systems, spanning a 3.5‐V range of reduction potentials) was used to build the correlations. This methodology was found to be computationally inexpensive compared with other approaches and to permit the useful prediction of reduction potentials of additional molecules of diverse structural types not included in the families used to determine the correlation parameters. The effects of varying the basis set used in the B3LYP electronic structure calculations and including solvent (compared with calculations in gas phase) were also examined. It was found that the inclusion of a continuum solvent model in the calculations was required for accurate results, particularly when including cationic species in the correlations (although when only neutral molecules were examined, reasonable results could even be obtained in vacuo ). Several of the best correlations were used to predict the reduction potentials of seven much larger and structurally diverse chromophores that were not included in the correlation data set. Strong correlations ( r 2 values > 0.99) with very good predictive abilities (root mean square deviation < 60 mV) were found. This extremely simple and computationally efficient entirely closed‐shell methodology is proven robust and useful for the design of new molecules capable of participating in redox processes, including electron transfer reactions. Copyright © 2015 John Wiley & Sons, Ltd.

Méndez‐Hernández, Dalvin D.↗

A modular methodology for time-domain stochastic seismic wave propagation

Presented here is a modular methodology for time-domain stochastic seismic wave propagation analysis. Presented methodology is designed to analyse uncertain seismic motions as an input, propagating through uncertain material. Traditional approach for uncertain wave propagation relies on models that include deep bedrock, local soil site, and their random process and random field information. Such models can become quite large and computationally intractable. The modular approach proposed herein features two step approach that allows separate consideration of the deep bedrock and local site along with corresponding random field information. In this work, the first step considers an auxiliary stochastic motions problem in the bedrock. Stochastic local site response can then be simulated in a reduced domain within certain depth from the surface. Application of uncertain seismic motions at depth, for local uncertain site response is done using stochastic effective forces developed through the Domain Reduction Method. By using Hermite polynomial chaos expansion to represent the non-Gaussian random field of material parameters and non-stationary random process of seismic motion, the proposed modular methodology is formulated using intrusive stochastic Galerkin approach, as seen in the Stochastic Elastic–Plastic Finite Element Method (SEPFEM). Developed modular methodology is illustrated using a 1-D stochastic seismic wave propagation analysis with three cases, and simulation results are also verified with results from conventional approach.

58 GEOSCIENCES↗

SU-F-T-31: Shape and Isodose Distributions in Co60 HDR Brachytherapy for Different Utero-Vaginal Time Ratios

Purpose: To optimize the dose in bladder and rectum and show the different shapes of the isodose volumes in Co60-HDR brachytherapy, considering different utero and vaginal sources dwell ratio times (TU:TV). Methods: Besides Ir192-HDR, new Co60-HDR sources are being incorporated. We considered different TU:TV times and computed the dosis in bladder, rectum and at the reference points of the Manchester system. Also, we calculated the isodose volume and shape in each case. We used a EZAG-BEBIG Co0.A86 model with TPS HDRplus3.0.4. and LCT42-7, LCT42-2(R,L) applicators. A reference dose RA= 1.00 Gy was given to the A-right point. We considered the TU:TV dwell time ratios 1:0.25, 1:0.33, 1:0.5, 1:1, 1:2, 1:3, and 1:4. Given TU:TV, the stop time at each dwell position is fixed for each applicator. Results: Increasing TU:TV systematically results in a decreasing of the dose in bladder and rectum, e.g. 9% and 27% reduction were found in 1:0.25 with respect to 1:1, while 12% and 34% increase were found in 1:4 with respect to 1:1. Also, the isodose volume parameters height (h), width (w), thickness (t) and volume (hwt) increased from the 1:0.25 case to the 1:4 value: hwt is 25% lower and 31% higher than the 1:1 reference volume in these cases. Also w decreased for higher TU:TV and may compromise the tumoral volume coverage, decreasing 17% in the 1:0.25 case compared to the 1:1 case. The shape of the isodose volume was obtained for the different TU:TV considered. Conclusion: We obtained the shape of isodose volumes for different TU:TV values in gynecological Co60-HDR. We studied the dose reduction in bladder and rectum for different TU:TV ratios. The volume parameters and hwt are strongly dependent on this ratio. This information is useful for a quantitative check of the TPS and as a starting point towards optimization.

60 APPLIED LIFE SCIENCES↗

Quantization of the B=1 and B=2 Skyrmions

We propose to set the Skyrme parameters F{sub {pi}} and e such that they reproduce the physical masses of the nucleon and the deuteron. We allow deformation using an axially symmetric solution and simulated annealing to minimize the total energy for the B=1 nucleon and B=2 deuteron. First we find that axial deformations are responsible for a significant reduction (factor of {approx_equal}4) of the rotational energy but also that it is not possible to get a common set of parameters F{sub {pi}} and e which would fit both nucleon and deuteron masses simultaneously at least for m{sub {pi}}=138 MeV, 345 MeV and 500 MeV. This suggests that either m{sub {pi}}>500 MeV or additional terms must be added to the Skyrme Lagrangian.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Frequency and field dependent dynamic properties of CoFe{sub 2−x}Al{sub x}O{sub 4} ferrite nanoparticles

Highlights: “CoFe{sub 2−x} Al{sub x}O{sub 4} ferrite nanoparticles: Static and dynamic properties” • Grain size reduction with Al{sup 3+} content. • Reduction in Ms, Hc, with increasing Al{sup 3+} content. • Increase in resonance frequency with applied field. • Decrease in resonance field with increase in Al{sup 3+} content. • Decrease in Gilbert parameter with increase in Al{sup 3+} content. - Abstract: Aluminum doped CoFe{sub 2−x}Al{sub x}O{sub 4} (0 ≤ x ≤ 0.9) nanoparticles were synthesized via auto-combustion. Formation of single phase cubic spinel structure was confirmed by X-ray diffraction (XRD) analysis. XRD analysis suggests a linear decrease in lattice cell parameters and grain size (90–55 nm) with the increase in Al{sup 3+} content. The saturation magnetization of samples decrease with increasing Al{sup 3+} content due to magnetic dilution effect. A concomitant linear reduction in coercivity was also observed mainly due to decrease in magnetic anisotropy. Frequency and field dependent dynamic properties of nanoparticles were studied by ferromagnetic resonance (FMR) technique. The resonance frequency increases linearly with magnetic field for all nanoparticles. Magnetic field dependent experimental absorption data (S{sub 21} vs. frequency) were compared with effective medium theory considering an effective demagnetization field and was observed to be in good agreement with each other. High Al{sup 3+} content reduces the Gilbert damping parameter thus making CoFe{sub 2−x}Al{sub x}O{sub 4} as an attractive material for high frequency applications.

36 MATERIALS SCIENCE↗

Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relating fish health and reproductive metrics to contaminant bioaccumulation at the Tennessee Valley Authority Kingston coal ash spill site

A 4.1 million m 3 release of coal ash into the Emory and Clinch rivers in December 2008 at Tennessee Valley Authority s Kingston Fossil Plant has prompted a long-term, large-scale biological monitoring effort to determine if there are chronic effects of this spill on biota. Of concern in this spill were arsenic (As) and selenium (Se), heavy metal constituents of coal ash that can be toxic to fish and wildlife and also mercury (Hg): a legacy contaminant that can interact with Se in organisms. We used fish filet bioaccumulation data from Bluegill Lepomis macrochirus, Redear Lepomis microlophus, Largemouth Bass Micropterus salmoides and Channel Catfish Ictalurus punctatus and metrics of fish health including fish condition indices, blood chemistry parameters and liver histopathology data collected from 2009-2013 to determine whether tissue heavy metal burdens relate 1) to each other 2) to metrics of fish health (e.g., blood chemistry characteristics and liver histopathology) and condition, and 3) whether relationships between fish health characteristics and heavy metals are related to site and ash-exposure. We found that burdens of Se and As are generally related to each other between tissues, but burdens of Hg between tissues are not generally positively associated. Taking analyses together, there appears to be reductions in growth and sublethal liver and kidney dysfunction in Bluegill and Largemouth Bass as indicated by blood chemistry parameters (elevated blood protein, glucose, phosphorous, blood urea nitrogen and creatinine in ash-affected sites) and related to concentrations of As and Se. Seeing sub-lethal effects in these species of fish is interesting because Redear had the highest filet burdens of Se, but did not have biomarkers indicating disease or dysfunction. We conclude our study by highlighting the complexities inherent in multimetric fish health data and the need for continued monitoring to further untangle contaminant and fish health associations.

54 ENVIRONMENTAL SCIENCES↗

A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282

Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.

36 MATERIALS SCIENCE↗

Long-Term Prediction of Radionuclide Emission from Submerged Objects in the Kara Sea

Analysis of the distribution of radionuclides in the water and bottom deposits in the bays of the Kara Sea attests that the radionuclide emission from the sources of radioactive materials dumped into the bays decrease over time. The equations of the transport of radionuclides in submerged objects into the marine environment beyond their limits were constructed on the basis of new results. Evaluations of the consequences of the long-term presence of submerged radiation-hazardous objects at the sea bottom depend on the temporal reduction of the time constant for the emission of radionuclides. The calculations show that taking account of this parameter with the formation of corrosion openings in closed submerged objects the emission of {sup 239}Pu from them into the ambient environment will almost cease after several hundreds of years (700 or more years). Neglecting this factor, the emission of {sup 239}Pu will continue to increase for 6000–12000 years, and the contamination of the bottom deposits by this isotope will be significant.

54 ENVIRONMENTAL SCIENCES↗

Dynamic deformation and failure of ultrafine-grained titanium

Dynamic deformation and shear localization of ultrafine-grained (~120 nm) pure titanium are examined. The strain hardening can be considered as having two regimes: below and above a strain ~0.04; at this point there is a drastic decrease in the slope. The strain-rate sensitivity of ultrafine-grained titanium is found to be approximately the same as its coarse grained counterpart. Based on experimentally determined parameters, the Zerilli-Armstrong equation is modified to describe the mechanical response of the ultrafine-grained titanium over the strain rate range 10 -5 to 10 3 s -1 . Adiabatic shear banding is examined in a forced shear configuration where large strain is imposed in a narrow region. The microstructure inside the adiabatic shear band consists of a mixture of elongated grains and equiaxed nanograins (~40 nm) that are significantly smaller than the initial grains (~120 nm). The formation of equiaxed nanograins is modeled through a mechanism of rotational dynamic recrystallization. This further reduction in grain size from the one generated by ECAP is interpreted in terms of the Zener-Hollomon parameter for quasistatic and dynamic deformation. The adiabatic shear band eventually fractures by a combination of brittle and ductile failure.

36 MATERIALS SCIENCE↗