Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Performance Demonstration Program Plan for Analysis of Simulated Headspace Gases

The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements of prompt radiation induced conductivity of alumina and sapphire

We performed measurements of the prompt radiation induced conductivity in thin samples of Alumina and Sapphire at the Little Mountain Medusa LINAC facility in Ogden, UT. Five mil thick samples were irradiated with pulses of 20 MeV electrons, yielding dose rates of 1E7 to 1E9 rad/s. We applied variable potentials up to 1 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 1E 10 and 1E 9 mho/m/(rad/s), depending on the dose rate and the pulse width for Alumina and 1E 7 to 6E 7 mho/m/(rad/s) for Sapphire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparisons of Force Measurement Methods for DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators with cylindrical exposed electrodes, as the electrode diameter decrease the force efficiencies increase much faster than a previously reported linear trend. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. Actuators with rectangular cross-section exposed electrodes do not show the same rapid increase at small thicknesses. We have also shown that the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Federated Machine Learning-Based Anomaly Detection System for Synchrophasor Network Using Heterogeneous Data Sets: Preprint

Synchrophasor technology is widely deployed in the energy management system to monitor the grid health at micro level and perform necessary corrective actions in real time; however, integrated phasor devices and data aggregators are exposed to several cybersecurity threats. This paper proposes a federated ML(FML)-based ADS to detect several data integrity attacks in the synchrophasor network. The proposed approach integrates the horizontal FML technique and consists of substation-based local models and a control center-based global model. The proposed methodology includes training local models using heterogeneous data sets that include network and grid information and updating the global model through multiple iterations by sharing model gradients. Finally, the trained global model is applied to identify cyberattacks, normal operation, and physical events. To validate the proof of concept, we used synthetic data sets generated by Mississippi State University and Oak Ridge National Laboratory for training and testing the classification models using the National Renewable Energy Laboratory's high performance computing resources. Our experimental results, computed through several performance measures, reveal that the proposed approach shows consistent performance during the binary, three-class, and multiclass classifications while ensuring privacy of synchrophasor data.

anomaly detection system↗

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

SU-E-J-271: A Feasibility Study to Utilize XR-QA2 Radiochromic Films as An Alternative Tool for Measuring Beam Parameters of Kilovoltage CBCT Systems

Purpose: The beam parameters of the x-ray beams used in image guidance are difficult to measure in water due to the low exposure. This study is to investigate if XR-QA2 radiochromic films can be used in obtaining beam parameters, such as beam profiles and outputs for kV-CBCT systems. Methods: The kV-CBCT beams were from a Varian OBI system. The films used were XR-QA2-GAFCHROMICTM films placed in the middle of two Plastic -Water slab phantoms at isocenter. The scanner used to analyze the films was an Epson Expression 1680 flat-bed scanner. Pre and 24 h-post-irradiated scans of films were obtained by using the reflective mode. The corresponding pixel-by-pixel dose in the films was obtained using a dose calibration equation as a function of net reflectance from the literature. Beam profiles of different scan protocols with and without bow-tie filters were measured. Monte Carlo simulations were used to compare the accuracy of the measured dose profiles. Results: The beam profiles measured from XR-QA2 films for different clinical default kV-CBCT scan protocols were benchmarked against Monte Carlo simulated profiles which have been validated by measurements performed in water phantom. We confirmed that a minimum post-irradiated time of 24 hours is necessary to pass to scan the films to account for light scatter stability. We found that the uncertainties of the results depend on the scan orientation of the film when analyzed in different directions. Conclusion: The XR-QA2 radiochromic films are sensitive to measure the x-ray beam profiles with irradiated dose ranging 1–5 cGy. The film measurements can be performed with an easy setup compared to ion chamber measurements in a water phantom. These films provide an alternative method to obtain the beam profiles for kV-CBCT beams.

60 APPLIED LIFE SCIENCES↗

ThickBrick: optimal event selection and categorization in high energy physics. Part I. Signal discovery

We provide a prescription called ThickBrick to train optimal machine-learning-based event selectors and categorizers that maximize the statistical significance of a potential signal excess in high energy physics (HEP) experiments, as quantified by any of six different performance measures. For analyses where the signal search is performed in the distribution of some event variables, our prescription ensures that only the information complementary to those event variables is used in event selection and categorization. This eliminates a major misalignment with the physics goals of the analysis (maximizing the significance of an excess) that exists in the training of typical ML-based event selectors and categorizers. In addition, this decorrelation of event selectors from the relevant event variables prevents the background distribution from becoming peaked in the signal region as a result of event selection, thereby ameliorating the challenges imposed on signal searches by systematic uncertainties. Our event selectors (categorizers) use the output of machine-learning-based classifiers as input and apply optimal selection cutoffs (categorization thresholds) that are functions of the event variables being analyzed, as opposed to flat cutoffs (thresholds). These optimal cutoffs and thresholds are learned iteratively, using a novel approach with connections to Lloyd’s k-means clustering algorithm. We provide a public, Python implementation of our prescription, also called ThickBrick, along with usage examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of top quark mass measurements in CMS

The top quark mass is one of the most intriguing parameters of the standard model (SM). Its value indicates a Yukawa coupling close to unity, and the resulting strong ties to Higgs physics make the top quark mass a crucial ingredient for understanding essential aspects of the electroweak sector of the SM. This review offers the first comprehensive overview of the top quark mass measurements performed by the CMS Collaboration using the data collected at centre-of-mass energies of 7, 8, and 13 TeV. Moreover, a detailed description of the top quark event reconstruction is provided and dedicated studies of the dominant uncertainties in the modelling of the signal processes are discussed. The interpretation of the experimental results on the top quark mass in terms of the SM Lagrangian parameter is challenging and is a focus of an ongoing discussion in the theory community. The CMS Collaboration has performed two main types of top quark mass measurements, addressing this challenge from different perspectives: highly precise ‘direct’ measurements, based on reconstructed top quark decay products and relying exclusively on Monte-Carlo simulations, as well as ‘indirect’ measurements, where the simulations are employed to determine parton-level cross sections that are compared to fixed-order perturbative calculations. Recent mass extractions using Lorentz-boosted top quarks open a new avenue of measurements based on top quark decay products contained in a single particle jet, with promising prospects for accurate theoretical interpretations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation Evaluation of a Large-Scale Implementation of Virtual-Phase Link-Based Model Predictive Control

Traffic congestion is a serious problem in the US, and traffic signal control is one of the effective solutions to congestion. Previous research on model predictive control (MPC)-based traffic signal control showed substantial benefits over conventional methods. This study focused on implementing MPC over a large-scale network with complex intersections and the impact of cycle length, network size, and imperfect state estimation on performances. This study implemented a virtual phase link (VPL)-based model predictive control method which used the number of vehicles in each VPL as input state variables and was suitable for National Electrical Manufacturing Association (NEMA) ring-barrier control. To test the impact of network size, the performance of distributed MPC (36 intersections in the network are divided into five subnetworks) was compared with that of MPC over the full network for a set of cycle lengths. To test the impact of imperfect state estimation, we synthetically infused estimation error and developed two scenarios, MPC-error and MPC-error narrow, which had higher and lower estimation errors, respectively. The performance of these MPC methods was compared with that of the existing time-of-day (TOD) method and an offline method that used Webster's method for split and MULTIBAND for cycle length and offset optimization. Trajectory and linkwise signal performance measures were collected from the simulation to evaluate performance. The distributed MPC method with perfect state estimation had the lowest delay and highest energy efficiency of all the methods. The performance of MPC decreased as the prediction inaccuracy increased. MPC-error had 7% and 11% more delay than MPC-error narrow in the morning and evening peaks, respectively. Overall, simulation results suggest that even with imperfect state estimation, MPC methods will outperform offline methods significantly.

large-scale simulation↗

Real-time feedback control of a mesoscopic superposition

We show that continuous real-time feedback can be used to track, control, and protect a mesoscopic superposition of two spatially separated wave packets. The feedback protocol is enabled by an approximate state estimator and requires two continuous measurements, performed simultaneously. For nanomechanical and superconducting resonators, both measurements can be implemented by coupling the resonators to superconducting qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance and rotor loads measurements of the Lynx XZ170 helicopter with rectangular blades

This report presents the results of a series of flight tests on the Lynx XZ170 helicopter with rectangular blades. The test objectives were to explore the flight envelope and to measure the performance and structural loads of the Lynx main-rotor system. The tests were conducted as part of the British Experimental Rotor Program (BERP) under a contract with the Ministry of Defense in England. Data were acquired for steady-level flights at five weight coefficients. Some flight conditions were tested at beyond the retreating-blade stall boundary, which was defined by a predetermined limit on the pitchlink vibratory load. In addition to documenting the flight conditions and data, this report describes the aircraft, particularly the rotor system, in detail.

Lau, Benton H.↗

Advanced Communication Technology Satellite (ACTS) Multibeam Antenna On-Orbit Performance

The NASA Lewis Research Center's Advanced Communication Technology Satellite (ACTS) was launched in September 1993. ACTS introduced several new technologies, including a multibeam antenna (MBA) operating at extremely short wavelengths never before used in communications. This antenna, which has both fixed and rapidly reconfigurable high-energy spot beams (150 miles in diameter), serves users equipped with small antenna terminals. Extensive structural and thermal analyses have been performed for simulating the ACTS MBA on-orbit performance. The results show that the reflector surfaces (mainly the front subreflector), antenna support assembly, and metallic surfaces on the spacecraft body will be distorted because of the thermal effects of varying solar heating, which degrade the ACTS MBA performance. Since ACTS was launched, a number of evaluations have been performed to assess MBA performance in the space environment. For example, the on-orbit performance measurements found systematic environmental disturbances to the MBA beam pointing. These disturbances were found to be imposed by the attitude control system, antenna and spacecraft mechanical alignments, and on-orbit thermal effects. As a result, the MBA may not always exactly cover the intended service area. In addition, the on-orbit measurements showed that antenna pointing accuracy is the performance parameter most sensitive to thermal distortions on the front subreflector surface and antenna support assemblies. Several compensation approaches were tested and evaluated to restore on-orbit pointing stability. A combination of autotrack (75 percent of the time) and Earth sensor control (25 percent of the time) was found to be the best way to compensate for antenna pointing error during orbit. This approach greatly minimizes the effects of thermal distortions on antenna beam pointing.

Source record↗

Existing Whole-House Solutions Case Study: Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland

Under this project, the BA-PIRC research team evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit at the Bay Ridge multifamily development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This case study summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete.

BA-PIRC↗

Performance Portability Evaluation of OpenCL Benchmarks across Intel and NVIDIA Platforms

We evaluate the capabilities of vendor-provided OpenCL implementations for performance portability across multiple computing platforms. The Rodinia benchmark suite is used for this evaluation. We apply the metric defined by Pennycook et al., and we use roofline efficiency from the Roofline performance model as the "performance efficiency" in the metric's definition. We found that the delivered performance portability is similar for several benchmarks, even if the roofline-based performance efficiencies across platforms are very different among the benchmarks. To help distinguish between these instances, we extend the metric by adding the standard deviation of the performance efficiencies for each benchmark. We argue that the standard deviation gives additional insight into performance portability assessment since it adds the performance variability across platforms. Additionally, we discuss the challenges to measure performance portability associated with algorithms and system software. In terms of algorithms, we need to carefully construct the benchmarks and appropriately use the concurrency available on a platform. In terms of system software, we depend on the vendor performance tools to support the desired programming model and runtime to be able to measure the metrics of interest.

GPU↗

Olympus receiver evaluation and phase noise measurements

A set of measurements performed by the Michigan Tech Sensing and Signal Processing Group on the analog receiver built by the Virginia Polytechnic Institute (VPI) and the Jet Propulsion Laboratory (JPL) for propagation measurements using the Olympus Satellite is described. Measurements of local oscillator (LO) phase noise were performed for all of the LOs supplied by JPL. In order to obtain the most useful set of measurements, LO phase noise measurements were made using the complete VPI receiver front end. This set of measurements demonstrates the performance of the receiver from the Radio Frequency (RF) input through the high Intermediate Frequency (IF) output. Three different measurements were made: LO phase noise with DC on the voltage controlled crystal oscillator (VCXO) port; LO phase noise with the 11.381 GHz LO locked to the reference signal generator; and a reference measurement with the JPL LOs out of the system.

Campbell, Richard L.↗