Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Precision Higgs physics at the CEPC

The discovery of the Higgs boson with its mass around 125 GeV by the ATLAS and CMS Collaborations marked the beginning of a new era in high energy physics. The Higgs boson will be the subject of extensive studies of the ongoing LHC program. At the same time, lepton collider based Higgs factories have been proposed as a possible next step beyond the LHC, with its main goal to precisely measure the properties of the Higgs boson and probe potential new physics associated with the Higgs boson. The Circular Electron Positron Collider~(CEPC) is one of such proposed Higgs factories. The CEPC is an $e^+e^-$ circular collider proposed by and to be hosted in China. Located in a tunnel of approximately 100~km in circumference, it will operate at a center-of-mass energy of 240~GeV as the Higgs factory. In this paper, we present the first estimates on the precision of the Higgs boson property measurements achievable at the CEPC and discuss implications of these measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Timing with the CMS MIP Timing Detector

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High Luminosity LHC (HL-LHC). A new timing layer is designed to measure minimum ionizing particles (MIPs) with a time resolution of 30 ps and hermetic coverage up to a pseudo-rapidity of |η|=3. This MIP Timing Detector (MTD) will consist of a central barrel region based on LYSO:Ce crystals read out with SiPMs and two end-caps instrumented with radiation-tolerant Low Gain Avalanche Detectors (LGADs). The precision time information from the MTD will reduce the effects of the high levels of pile-up expected at the HL-LHC and will bring new and unique capabilities to the CMS detector. The time information assigned to each track will enable the use of 4D-vertexing which will render a 5-fold pile-up reduction thus recovering the current conditions. Precision timing will also enable new time-based isolations and improved b-tagging algorithms. All of this translates into a 20% gain in effective luminosity when looking at di-Higgs boson events decaying to a pair of b-quarks and two photons. We present the current status and ongoing R&D of the MTD, including implications on the physics reach at the HL-LHC and test beam results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing with Silicon Sensors for Use in Calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 10 34 cm -2 s -1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-driven precision determination of the material budget in ALICE

The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH PRECISION ABUNDANCES IN THE 16 Cyg BINARY SYSTEM: A SIGNATURE OF THE ROCKY CORE IN THE GIANT PLANET

We study the stars of the binary system 16 Cygni to determine with high precision their chemical composition. Knowing that the component B has a detected planet of at least 1.5 Jupiter masses, we investigate if there are chemical peculiarities that could be attributed to planet formation around this star. We perform a differential abundance analysis using high resolution (R = 81,000) and high S/N (∼700) CFHT/ESPaDOnS spectra of the 16 Cygni stars and the Sun; the latter was obtained from light reflected of asteroids. We determine differential abundances of the binary components relative to the Sun and between components A and B as well. We achieve a precision of σ ≲ 0.005 dex and a total error ∼0.01 dex for most elements. The effective temperatures and surface gravities found for 16 Cyg A and B are T {sub eff} = 5830 ± 7 K, log g = 4.30 ± 0.02 dex, and T {sub eff} = 5751 ± 6 K, log g = 4.35 ± 0.02 dex, respectively. The component 16 Cyg A has a metallicity ([Fe/H]) higher by 0.047 ± 0.005 dex than 16 Cyg B, as well as a microturbulence velocity higher by 0.08 km s{sup –1}. All elements show abundance differences between the binary components, but while the volatile difference is about 0.03 dex, the refractories differ by more and show a trend with condensation temperature, which could be interpreted as the signature of the rocky accretion core of the giant planet 16 Cyg Bb. We estimate a mass of about 1.5-6 M {sub ⊕} for this rocky core, in good agreement with estimates of Jupiter's core.

79 ASTRONOMY AND ASTROPHYSICS↗

ARTIFICIAL INCOHERENT SPECKLES ENABLE PRECISION ASTROMETRY AND PHOTOMETRY IN HIGH-CONTRAST IMAGING

State-of-the-art coronagraphs employed on extreme adaptive optics enabled instruments are constantly improving the contrast detection limit for companions at ever-closer separations from the host star. In order to constrain their properties and, ultimately, compositions, it is important to precisely determine orbital parameters and contrasts with respect to the stars they orbit. This can be difficult in the post-coronagraphic image plane, as by definition the central star has been occulted by the coronagraph. We demonstrate the flexibility of utilizing the deformable mirror in the adaptive optics system of the Subaru Coronagraphic Extreme Adaptive Optics system to generate a field of speckles for the purposes of calibration. Speckles can be placed up to 22.5 λ/D from the star, with any position angle, brightness, and abundance required. Most importantly, we show that a fast modulation of the added speckle phase, between 0 and π, during a long science integration renders these speckles effectively incoherent with the underlying halo. We quantitatively show for the first time that this incoherence, in turn, increases the robustness and stability of the adaptive speckles, which will improve the precision of astrometric and photometric calibration procedures. This technique will be valuable for high-contrast imaging observations with imagers and integral field spectrographs alike.

79 ASTRONOMY AND ASTROPHYSICS↗

New candidates for regulated gene integrity revealed through precise mapping of integrative genetic elements

Abstract Integrative genetic elements (IGEs) are mobile multigene DNA units that integrate into and excise from host bacterial genomes. Each IGE usually targets a specific site within a conserved host gene, integrating in a manner that preserves target gene function. However, a small number of bacterial genes are known to be inactivated upon IGE integration and reactivated upon excision, regulating phenotypes of virulence, mutation rate, and terminal differentiation in multicellular bacteria. The list of regulated gene integrity (RGI) cases has been slow-growing because IGEs have been challenging to precisely and comprehensively locate in genomes. We present software (TIGER) that maps IGEs with unprecedented precision and without attB site bias. TIGER uses a comparative genomic, ping-pong BLAST approach, based on the principle that the IGE integration module (i.e. its int-attP region) is cohesive. The resultant IGEs from 2168 genomes, along with integrase phylogenetic analysis and gene inactivation tests, revealed 19 new cases of genes whose integrity is regulated by IGEs (including dut, eccCa1, gntT, hrpB, merA, ompN, prkA, tqsA, traG, yifB, yfaT and ynfE), as well as recovering previously known cases (in sigK, spsM, comK, mlrA and hlb genes). It also recovered known clades of site-promiscuous integrases and identified possible new ones.

59 BASIC BIOLOGICAL SCIENCES↗

Islander: A database of precisely mapped genomic islands in tRNA and tmRNA genes

Genomic islands are mobile DNAs that are major agents of bacterial and archaeal evolution. Integration into prokaryotic chromosomes usually occurs site-specifically at tRNA or tmRNA gene (together, tDNA) targets, catalyzed by tyrosine integrases. This splits the target gene, yet sequences within the island restore the disrupted gene; the regenerated target and its displaced fragment precisely mark the endpoints of the island. We applied this principle to search for islands in genomic DNA sequences. Our algorithm identifies tDNAs, finds fragments of those tDNAs in the same replicon and removes unlikely candidate islands through a series of filters. A search for islands in 2168 whole prokaryotic genomes produced 3919 candidates. The website Islander (recently moved to http://bioinformatics.sandia.gov/islander/) presents these precisely mapped candidate islands, the gene content and the island sequence. The algorithm further insists that each island encode an integrase, and attachment site sequence identity is carefully noted; therefore, the database also serves in the study of integrase site-specificity and its evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Precise mapping of new group I introns in tRNA genes

Bacterial tRNA have been found interrupted at various positions in the anticodon loop by group I introns, in four types. The primary bioinformatic tool for group I intron discovery is a covariance model that can identify conserved features in the catalytic core and can sometimes identify the typical uridine residue at the -1 position, preceding the 5-prime splice site, but cannot identify the typical guanidine residue at the omega position, preceding the 3-prime splice site, to achieve precise mapping. One approach to complete the automation of group I intron mapping is to focus instead on the exons, which is enabled by the regularity of tRNAs. We develop a software module, within a larger package (tFind) aimed at mapping bacterial tRNA and tmRNA genes precisely, that expands this list of four known classes of intron-interrupted tRNAs to 21 cases. A new covariance model for these introns is presented. The wobble base pair formed by the -1 uridine is considered a determinant of the 5-prime splice site, yet one reasonably large new type bears a cytidine nucleotide at that position.

Williams, Kelly P.↗

Precision Measurement of Net-Proton-Number Fluctuations in Au + Au Collisions at RHIC

We report precision measurements on cumulants (𝐶 𝑛 ) and factorial cumulants (𝜅 𝑛 ) of (net) proton number distributions up to fourth order in Au + Au collisions over center-of-mass energies $\sqrt{s_{NN}}$ = 7.7–27 GeV from phase II of the Beam Energy Scan program at RHIC. (Anti)protons are selected at midrapidity (|𝑦| < 0.5) within a transverse momentum range of 0.4 < 𝑝 𝑇 < 2.0 GeV/𝑐. Relative to various noncritical-point model calculations and peripheral collision 70%–80% data, the net proton 𝐶 4 /𝐶 2 measurement in 0%–5% collisions shows a minimum around 19.6 GeV for significance of deviation at ∼2–5⁢𝜎. A minimum in 𝐶 4 /𝐶 2 with respect to a noncritical baseline is expected to be a characteristic feature of the signature associated with a critical point in the QCD phase diagram. In addition, deviations from noncritical baselines around the same collision energy region are also seen in proton factorial cumulant ratios, especially in 𝜅 2 /𝜅 1 and 𝜅 3 /𝜅 1 . As a result, dynamical model calculations including a critical point are called for in order to understand these precision measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass of {sup 17}O from Penning-trap mass spectrometry and molecular spectroscopy: A precision test of the Dunham-Watson model in carbon monoxide

By fitting the Dunham-Watson model to extensive rotational and vibrational spectroscopic data of isotopic variants of CO, and by using existing precise masses of {sup 13}C,{sup 16}O, and {sup 18}O from Penning-trap mass spectrometry, we determine the atomic mass of {sup 17}O to be M[{sup 17}O]=16.999 131 644(30) u, where the uncertainty is purely statistical. Using Penning-trap mass spectrometry, we have also directly determined the atomic mass of {sup 17}O with the more precise result M[{sup 17}O]=16.999 131 756 6(9) u. The Dunham-Watson model applied to the molecular spectroscopic data hence predicts the mass of {sup 17}O to better than 1 part in 10{sup 8}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Relativistic general-order coupled-cluster method for high-precision calculations: Application to the Al{sup +} atomic clock

We report the implementation of a general-order relativistic coupled-cluster method for performing high-precision calculations of atomic and molecular properties. As a first application, the black-body radiation shift of the Al{sup +} clock has been estimated precisely. The computed shift relative to the frequency of the 3s{sup 2} {sup 1}S{sub 0}{sup e}{yields}3s3p {sup 3}P{sub 0}{sup o} clock transition given by (-3.66{+-}0.60)x10{sup -18} calls for an improvement over the recent measurement with a reported result of (-9{+-}3)x10{sup -18}[Phys. Rev. Lett. 104, 070802 (2010)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Precision requirements for spin-echo-based quantum memories

Spin-echo techniques are essential for achieving long coherence times in solid-state quantum memories for light because of inhomogeneous broadening of the spin transitions. It has been suggested that unrealistic levels of precision for the radio-frequency control pulses would be necessary for successful decoherence control at the quantum level. Here we study the effects of pulse imperfections in detail, using both a semiclassical and a fully quantum-mechanical approach. Our results show that high efficiencies and low noise-to-signal ratios can be achieved for the quantum memories in the single-photon regime for realistic levels of control pulse precision. We also analyze errors due to imperfect initial-state preparation (optical pumping), showing that they are likely to be more important than control pulse errors in many practical circumstances. These results are crucial for future developments of solid-state quantum memories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Making precise predictions of the Casimir force between metallic plates via a weighted Kramers-Kronig transform

The possibility of making precise predictions for the Casimir force is essential for the theoretical interpretation of current precision experiments on the thermal Casimir effect with metallic plates, especially for submicron separations. For this purpose it is necessary to estimate very accurately the dielectric function of a conductor along the imaginary frequency axis. This task is complicated in the case of ohmic conductors because optical data do not usually extend to sufficiently low frequencies to permit an accurate evaluation of the standard Kramers-Kronig integral used to compute {epsilon}(i{xi}). By making important improvements to the results of a previous paper by the author, it is shown that this difficulty can be resolved by considering suitable weighted dispersion relations, which strongly suppress the contribution of low frequencies. The weighted dispersion formulas presented in this paper permit us to estimate accurately the dielectric function of ohmic conductors for imaginary frequencies, on the basis of optical data extending from the IR to the UV, with no need for uncontrolled data extrapolations toward zero frequency that are necessary with standard Kramers-Kronig relations. Applications to several sets of data for gold films are presented to demonstrate the viability of the dispersion formulas presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utility of atomic kicked-rotor interferometers for precision measurements

We theoretically investigate a proposed scheme to use an atomic {delta}-kicked rotor resonance for high-precision measurements of accelerations and the photon recoil frequency. Although the technique offers rapid scaling of the measurement sensitivity with pulse number, it also features a high sensitivity to initial atomic momentum. We find that for realistic atom sources, the momentum sensitivity significantly limits the achievable precision. We consider several different variations on the technique, but find similar limitations in all cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise determination of atomic g-factor ratios from a dual isotope magneto-optical trap

We demonstrate a technique, for carrying out precise measurements of atomic g-factor ratios, which relies on measurements of Larmor oscillations from coherences between magnetic sublevels in the ground states of {sup 85}Rb and {sup 87}Rb atoms confined in a dual isotope magneto-optical trap. We show that a measurement of g{sub F}{sup (87)}/g{sub F}{sup (85)} with a resolution of 0.69 parts per 10{sup 6} is possible by recording the ratio of Larmor frequencies in the presence of a constant magnetic field. This represents the most precise single measurement of g{sub F}{sup (87)}/g{sub F}{sup (85)} without correcting for systematic effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Precise branching ratio measurement for the superallowed β+ decay of 26 Si: Completion of a second mirror pair

As part of a continuing effort to test the unitarity of the Cabbibo-Kobayashi-Maskawa matrix, we have measured the branching ratio for the superallowed 0 + → 0 + β + -decay transition from 26 Si to be 0.7569(14), a result with 0.18% relative precision. With this result, the ft value for the transition is now established with comparable precision to the well-known superallowed transitions currently used in the determination of V ud . Furthermore, it also completes a second pair of mirror superallowed transitions, 26 Si → 26m Al and 26m Al → 26 Mg, the ratio of whose measured ft values provides a sensitive test of the method used to calculate the isospin-symmetry-breaking correction δ C needed to determine V ud . Like the previously measured ratio for the mass-38 mirror pair, the new result agrees well with the calculation based on Woods-Saxon radial wave functions and strengthens the case for rejecting the calculation that uses Hartree-Fock radial functions.

20 ≤ A ≤ 38↗