Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Investigating Fast Scanning Calorimetry and Differential Scanning Calorimetry as Screening Tools for Thermoset Polymer Material Compatibility with Laser-Based Powder Bed Fusion

As additive manufacturing (AM) technology has developed and progressed, a constant topic of research in the area is expanding the library of materials to be used with these techniques. Among AM methods that utilize polymers, laser-based powder bed fusion (PBF-LB) has preferentially used thermoplastic polymers as its starting materials, but the deposition and material joining method employed in PBF-LB may also be compatible with powdered thermoset polymer precursors as feedstocks. To assess the compatibility of candidate thermosetting polymers and PBF-LB, characterization techniques and protocols that link fundamental material behavior to material behavior in the processing environment are needed. Therefore, the objectives of this work are to compare the curing behavior measured with two different calorimetry techniques that can operate in different heating rate regimes, differential scanning calorimetry (DSC) and fast scanning calorimetry (FSC), and to assess the capabilities of these techniques to act as materials screening tools for PBF-LB. A commercial polyester powder coating is used as a model material to evaluate the potential of obtaining complimentary information for material screening through a combination of calorimetry methods, and its non-isothermal curing behavior is measured at heating rates between 5 °C/min and 7500 °C/min. Curing exotherms are observed with both calorimetry techniques, and comparing the enthalpy associated with curing shows that incomplete curing occurs at higher heating rates, with relative conversion values of approximately 30%. The curing data are fit with two isoconversional models, Friedman and Starink, which show a reduced activation energy at higher heating rates as well, signifying a lower barrier to curing at the conditions used in the FSC experiments. Overall, the results of this work indicate that using these two calorimetry techniques as tiered screening tools can provide valuable information about how curing may proceed in PBF-LB and inform materials selection and design activities for additive manufacturing.

36 MATERIALS SCIENCE↗

Experimental Approach for Deep Proteome Measurements from Small-Scale Microbial Biomass Samples.

Many methods of microbial proteome characterizations require large quantities of cellular biomass (> 1-2 g) for sample preparation and protein identification. Our experimental approach differs from traditional techniques by providing the ability to identify the proteomic state of a microbe from a few milligrams of starting cellular material. The small-scale, guanidine-lysis method minimizes sample loss by achieving cellular lysis and protein digestion in a single tube experiment. For this experimental approach, the freshwater microbe Shewanella oneidensis MR-1 and the purple non-sulfur bacterium Rhodopseudomonas palustris CGA0010 were used as model organisms for technology development and evaluation. A 2-D LC-MS/MS comparison between a standard sonication lysis method and the small-scale guanidine-lysis techniques demonstrates that the guanidine-lysis method is more efficient with smaller sample amounts of cell pellet (i.e. down to 1 mg). The described methodology would enable deep proteome measurements from a few milliliters of confluent bacterial cultures. We also report a new protocol for efficient lysis from small amounts of natural biofilm samples for deep proteome measurements, which should greatly enhance the emerging field of microbial community proteomics. This straightforward sample boiling protocol is complementary to the small-scale guanidine-lysis technique, is amenable for small sample quantities, and requires no special reagents that might complicate the MS measurements.

09 BIOMASS FUELS↗

Molten Chloride Technology Pathway to Meet the U.S. DOE SunShot Initiative with Gen3 CSP

Third-generation (Gen3) concentrating solar power (CSP) technologies require a thermally stable and inexpensive fluid to be used for heat transfer and thermal energy storage. For Gen3 CSP plants, a molten salt composed of MgCl2 - KCl - NaCl is a new candidate, but it is familiar enough to plants with existing molten-salt systems. To determine the best composition for the heat-transfer fluid, we mixed nine different ratios of the salts, dry/purified them following strict protocols, and tested them with a differential scanning calorimeter and a thermogravimetric analyzer. Our results showed that the lowest melting and solidification temperature of 385 degrees C +/- 1 degrees C was determined for the eutectic composition 44.7 MgCl2 - 25.8 KCl - 29.4 NaCl (mol.%). We determined that improper handling and preparation of the salt mixture highly affects its thermal properties because of moisture absorption. Preparation standards - particularly the dehydration of hydrous MgCl2 - merit further development.

14 SOLAR ENERGY↗

SMAC: A soft MAC to reduce control overhead and latency in CDMA-based AMI networks

The utilization of state-of-the-art 3G cellular CDMA technologies in a utility owned AMI network results in a large amount of control traffic relative to data traffic, increases the average packet delay and hence are not an appropriate choice for smart grid distribution applications. Like the CDG, we consider a utility owned cellular like CDMA network for smart grid distribution applications and classify the distribution smart grid data as scheduled data and random data. Also, we propose SMAC protocol, which changes its mode of operation based on the type of the data being collected to reduce the data collection latency and control overhead when compared to 3G cellular CDMA2000 MAC. The reduction in the data collection latency and control overhead aids in increasing the number of smart meters served by a base station within the periodic data collection interval, which further reduces the number of base stations needed by a utility or reduces the bandwidth needed to collect data from all the smart meters. The reduction in the number of base stations and/or the reduction in the data transmission bandwidth reduces the CAPital EXpenditure (CAPEX) and OPerational EXpenditure (OPEX) of the AMI network. Finally, the proposed SMAC protocol is analyzed using markov chain, analytical expressions for average throughput and average packet delay are derived, and simulation results are also provided to verify the analysis.

97 MATHEMATICS AND COMPUTING↗

Probing Curved Spacetime with a Distributed Atomic Processor Clock

Quantum dynamics on curved spacetime has never been directly probed beyond the Newtonian limit. Although we can describe such dynamics theoretically, experiments would provide empirical evidence that quantum theory holds even in this extreme limit. The practical challenge is the minute spacetime curvature difference over the length scale of the typical extent of quantum effects. Here, we propose a quantum network of alkaline earth (like) atomic processors for constructing a distributed quantum state that is sensitive to the differential proper time between its constituent atomic processor nodes, implementing a quantum observable that is affected by post-Newtonian curved spacetime. Conceptually, we propose to delocalize one clock between three locations by encoding the presence or absence of a clock into the state of the local atoms. By separating three atomic nodes over approximately kilometer-scale elevation differences and distributing one clock between them via a 𝑊 state, we demonstrate that the curvature of spacetime is manifest in the interference of the three different proper times that give rise to three distinct beat notes in our nonlocal observable. We further demonstrate that 𝑁-atom entanglement within each node enhances the interrogation bandwidth by a factor of 𝑁. We discuss how our proposed system can probe new facets of fundamental physics, such as the linearity, unitarity, and probabilistic nature of quantum theory on curved spacetime. Our protocol combines several recent advances with neutral atom and trapped ions to realize a novel quantum probe of gravity uniquely enabled by quantum networks.

Covey, Jacob P. [Univ. of Illinois at Urbana-Champ↗

Cryptographic robustness of practical quantum cryptography: BB84 key distribution protocol

In real fiber-optic quantum cryptography systems, the avalanche photodiodes are not perfect, the source of quantum states is not a single-photon one, and the communication channel is lossy. For these reasons, key distribution is impossible under certain conditions for the system parameters. A simple analysis is performed to find relations between the parameters of real cryptography systems and the length of the quantum channel that guarantee secure quantum key distribution when the eavesdropper's capabilities are limited only by fundamental laws of quantum mechanics while the devices employed by the legitimate users are based on current technologies. Critical values are determined for the rate of secure real-time key generation that can be reached under the current technology level. Calculations show that the upper bound on channel length can be as high as 300 km for imperfect photodetectors (avalanche photodiodes) with present-day quantum efficiency ({eta} {approx} 20%) and dark count probability (p{sub dark} {approx} 10{sup -7})

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-D-BRD-00: Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-02: Radiological Physics and Surface Lesion Treatments with Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Synthesis and Evaluation of Cu-SAPO-34 Catalysts for Ammonia Selective Catalytic Reduction. 1. Aqueous Solution Ion Exchange

SAPO-34 molecular sieves are synthesized using various structure directing agents (SDAs). Cu-SAPO-34 catalysts are prepared via aqueous solution ion exchange. Catalysts are characterized with surface area/pore volume measurements, temperature programmed reduction (TPR), electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR) spectroscopies. Catalytic properties are examined using standard ammonia selective catalytic reduction (NH3-SCR) and ammonia oxidation reactions. During solution ion exchange, different SAPO-34 samples undergo different extent of structural damage via irreversible hydrolysis. Si content within the samples (i.e., Al-O-Si bond density) and framework stress are key factors that affect irreversible hydrolysis. Even using very dilute Cu acetate solutions, it is not possible to generate Cu-SAPO-34 samples with only isolated Cu2+ ions. Small amounts of CuOx species always coexist with isolated Cu2+ ions. Highly active and selective Cu-SAPO-34 catalysts for NH3-SCR are readily generated using this synthesis protocol, even for SAPO-34 samples that degrade substantially during solution ion exchange. High-temperature aging is found to improve the catalytic performance. This is likely due to reduction of intracrystalline mass-transfer limitations via formation of additional porosity in the highly defective SAPO-34 particles formed after ion exchange. The authors gratefully acknowledge the US Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Office of Vehicle Technologies for the support of this work. The research described in this paper was performed at the Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory (PNNL). PNNL is operated for the US DOE by Battelle Memorial Institute under contract number DE-AC05-76RL01830.

chabazite↗

Performance Evaluation of LPBF Manufactured 316H Components

This work represents the continuation of a benchmark study that includes modeling, fabrication and characterization as demonstration to support industry’s adoption of advanced manufacturing processes in a variety of structures. This comprehensive study investigated the feasibility of using additive manufacturing (AM) technologies, specifically Laser Powder Direct Energy Deposition (LP-DED) and Laser Powder Bed Fusion (LPBF), to produce complex nuclear microreactor components using 316H stainless steel. The research focused on manufacturing an expanded elbow pipe component with transitioning sections, which are traditionally difficult and costly to produce through conventional manufacturing methods. The overall study’s primary objectives are therefore demonstrating AM viability for nuclear applications, optimizing process parameters, developing comprehensive material characterization protocols, validating computational modeling approaches, and establishing manufacturing guidelines for complex geometries. Although the initial work included the phased approach of cubical, upscaled cylindrical components, it is to enable to obtain more knowledge for the printing of the expanded elbow structure. The project achieved significant progress in process development by successfully optimizing LP-DED parameters to achieve 99.16-99.97% relative density in 316H stainless steel components. Through systematic evaluation of sixteen cube samples with varied laser powers (400-700W) and scan speeds (600-900 mm/min), optimal processing windows were identified at 500-550W with 600-700 mm/min or 650-700W with 650-900 mm/min scan speeds. The DED manufactured 316H demonstrated mechanical properties comparable or superior to wrought materials, with Young's modulus ranging from 153-208 GPa and controlled microstructural characteristics including greater than 95% face-centered cubic (FCC) phases and engineered cellular structures with sizes between 3.23-6.17 µm.

36 MATERIALS SCIENCE↗

What Can DMIS 5.2 Do For You?

The Dimensional Measuring Interface Standard (DMIS) is the first data interoperability protocol standard created specifically for dimensional metrology. DMIS applications are multi-facetted. The standard can behave as a coordinate metrology language to execute measurement part programs, or it can be used as a neutral data exchange mechanism for part programs and measurement results. DMIS is full featured and has many successful implementations. It also has a strong reputation as a progressive standard, one that has been responsive to user needs and technology advances. It is maintained and improved upon by a volunteer committee, the DMIS Standards Committee (DSC), under the auspices of the Dimensional Metrology Standards Consortium (DMSC Inc.). DMIS has progressed as its eighth version and its sixth as a national and/or international standard. Some notable advances of DMIS have included: • support for thin-walled (i.e., sheet-metal) measurements • alignment with American and International tolerancing standards • complete suite of measure features • harmonization with complementary standards and specifications • extension of additional sensors and scanning processes • introduction of measurement uncertainty computations • tighter CAD associativity • enhancements for multi-axis scanning • provisioning for functional subsets (application profiles) • progression of conformance class validations • designation of key characteristics with criticality designators • removal of ambiguities and syntactic limitations • clarification through additional diagrams and code fragments • resolution to over 600 standard improvement requests

97 MATHEMATICS AND COMPUTING↗

SELF-POWERED WIRELESS SENSOR NODE POWER MODELING BASED ON IEEE 802.11 COMMUNICATION PROTOCOL

Design and technical advancements in sensing, processing, and wireless communication capabilities of small, portable devices known as wireless sensor nodes (WSNs) have drawn extensive research attention and are vastly applied in science and engineering applications. The WSNs are typically powered by a chemical battery source that has a load dependent finite lifetime. Most applications, including the nuclear industry applications, require WSNs to operate for an extended period of time beginning with their deployment. To ensure longevity, it is important to develop self-powered WSNs. The benefit of self-powered WSNs goes far beyond the cost savings of removing the need for cable installation and maintenance. Self-powered WSNs will potentially offer significant expansion in remote monitoring of nuclear facilities, and provide important data on plant equipment and component status during normal operation, as well as in case of abnormal operation, station blackouts or post-accident evaluation. Advancements in power harvesting technologies enable electric energy generation from many sources, including kinetic, thermal, and radiated energy. For the ongoing research at Idaho National Laboratory, a solid-state thermoelectric-based technology, the thermoelectric generator (TEG), is used to convert thermal energy to power a WSN. The design and development of TEGs to power WSNs that would remain active for a long period of time requires comprehensive understanding of WSN operational. This motivates the research in modeling the lifetime, i.e., power consumption, of a WSN by taking into consideration various node and network level activities. A WSN must perform three essential tasks: sense events, perform quick local information processing of sensed events, and wirelessly exchange locally processed data with the base station or with other WSNs in the network. Each task has a power cost per unit tine and an additional cost when switching between tasks. There are number of other considerations that must also be taken into account when computing the power consumption associated with each task. The considerations includes: number of events occurring in a fixed active time period and the duration of each event, event-information processing time, total communication time, number of retransmission, etc. Additionally, at the network level the communication of information data packets between WSNs involves collisions, latency, andretransmission, which result in unanticipated power losses. This paper presents stochastic modeling of power demand for a schedule-driven WSN utilizing Institute of Electrical and Electronics Engineers, IEEE, 802.11 communication protocols. The model captures the generic operation of a schedule-driven WSN when an external event occurs, i.e., sensing, following by processing, and followed by communication. The results are verified via simulation.

IEEE 802.11 Protocol↗