Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

System and method for extracting a sample from a surface

A system and method is disclosed for extracting a sample from a sample surface. A sample is provided and a sample surface receives the sample which is deposited on the sample surface. A hydrophobic material is applied to the sample surface, and one or more devices are configured to dispense a liquid on the sample, the liquid dissolving the sample to form a dissolved sample material, and the one or more devices are configured to extract the dissolved sample material from the sample surface.

36 MATERIALS SCIENCE↗

Evidence for B - → τ - ν ¯ τ with a Hadronic Tagging Method Using the Full Data Sample of Belle

In this work, we measure the branching fraction of B - → τ - ν ¯ τ using the full Υ ( 4 S ) data sample containing 772 × 10 6 B B ¯ pairs collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. Events with B B ¯ pairs are tagged by reconstructing one of the B mesons decaying into hadronic final states, and B - → τ - ν ¯ τ candidates are detected in the recoil. We discover evidence for B - → τ - ν ¯ τ with a significance of 3.0 standard deviations including systematic errors and measure a branching fraction B ( B - → τ - ν ¯ τ ) = [ 0.72 - 0.25 + 0.27 ( stat ) ± 0.11 ( syst ) ] × 10 - 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sample analysis systems and methods of use thereof

The invention generally relates to sample analysis systems and methods of use thereof. In certain aspects, the invention provides a system for analyzing a sample that includes an ion generator configured to generate ions from a sample. The system additionally includes an ion separator configured to separate at or above atmospheric pressure the ions received from the ion generator without use of laminar flowing gas, and a detector that receives and detects the separated ions.

42 ENGINEERING↗

Random Sampling of Correlated Parameters – a Consistent Solution for Unfavourable Conditions

Two methods for random sampling according to a multivariate lognormal distribution – the correlated sampling method and the method of transformation of correlation coefficients – are briefly presented. The methods are mathematically exact and enable consistent sampling of correlated inherently positive parameters with given information on the first two distribution moments. Furthermore, a weighted sampling method to accelerate the convergence of parameters with extremely large relative uncertainties is described. However, the method is efficient only for a limited number of correlated parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Iodine-129 in Low Level Radioactive Wastes - 13334

For the radioactivity determination of {sup 129}I in the radioactive wastes, alkali fusion and anion-exchange resin separation methods, which are sample pretreatment methods, have been investigated in this study. To separate and quantify the {sup 129}I radionuclide in an evaporator bottom and spent resin, the radionuclide was chemically leached from the wastes and adsorbed on an anion exchange resin at pH 4, 7, 9. In the case of dry active waste and another solid type, the alkali fusion method was applied. KNO{sub 3} was added as a KOH and oxidizer to the wastes. It was then fused at 450 deg. C for 1 hour. The radioactivity of the separated iodine was measured with a low energy gamma spectrometer after the sample pretreatment. Finally, it was confirmed that the recovery rate of the iodine for the alkali fusion method was 83.6±3.8%, and 86.4±1.6% for the anionic exchange separation method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Techniques for Sample Processing of the Reusable Metal-Containing Raw Material (Review)

A review of the sample processing of different types of reusable metal-containing material (catalytic agents, e-wastes, cuttings, etc.) is given in the article; the purpose of the sample processing is the further analysis in the form of solutions: dilution in the mineral acid mix, alloying with different fluxes, leaching, etc. Increase in the temperature and pressure, ultrasonic impact, and microwave radiation are applied for the purpose of sample processing intensification. Methods of sample processing with application of sorbate concentration for the further definition of not only the noble, nonferrous, and rare metals but also the toxic elements are described. The review shows that the stage of sample processing is very important for achieving the potential of the applied analytical methods.

36 MATERIALS SCIENCE↗

Particulate Matter Sampling and Volatile Organic Compound Removal for Characterization of Spark Ignited Direct Injection Engine Emissions

More stringent emissions regulations are continually being proposed to mitigate adverse human health and environmental impacts of internal combustion. With that in mind, it has been proposed that vehicular particulate matter (PM) emissions should be regulated based on particle number in addition to particle mass. One aspect of this project is to study different sample handling methods for number based aerosol measurements, specifically, two different methods for removing volatile organic compounds (VOCs) from an aerosol sample. One method is a Dekati Thermodenuder (TD) and the other is an evaporative chamber/diluter (EvCh). These sample handling methods have been implemented for this project in an engine test cell built around a direct injection spark ignited (DISI) engine. The engine was designed for stoichiometric, homogeneous combustion. Direct injection is of particular interest for improved fuel efficiency but this comes with the production of a significant amount of (PM) and may therefore be subject to the proposed number based regulation. Another aspect of this project is to characterize PM from this engine in terms of particle number and composition. The first interesting observation is that PM number distributions, acquired using a TSI SMPS, have a large accumulation mode (30-294 nm) but a very small nuclei mode (8-30 nm). This is understood to represent a lack of condensation particles meaning that neither the exhaust conditions nor the sample handling conditions are conducive to condensation. This lack of nuclei mode does not, however, represent a lack of VOCs in the sample. It has been observed, using mass spectral analysis (limited to PM>50 nm), that PM from the DISI engine has approximately 40% organic content through varying operating conditions. This begs the question of how effective different sample handling methods are at removing these VOCs. For one specific operating condition, called Cold Start, the un-treated PM was 40% organic. The TD reduced this by 7% while the EvCh reduced it by 13%. For other operating conditions, PM treated for volatile removal actually exhibited an increase in organic fraction on the order of 5%. This addition appears to be sensitive to the gaseous hydrocarbon concentrations in the exhaust although a precise correlation has not yet been derived. It has been concluded that VOCs are tightly bound to the PM carbon core and thus are not effectively removed by either treatment method.

Environmental Molecular Sciences Laboratory↗

Convergence and Efficiency of Adaptive Importance Sampling Techniques with Partial Biasing

We propose a new Monte Carlo method to efficiently sample a multimodal distribution (known up to a normalization constant). We consider a generalization of the discrete-time Self Healing Umbrella Sampling method, which can also be seen as a generalization of well-tempered metadynamics. The dynamics is based on an adaptive importance technique. The importance function relies on the weights (namely the relative probabilities) of disjoint sets which form a partition of the space. These weights are unknown but are learnt on the fly yielding an adaptive algorithm. In the context of computational statistical physics, the logarithm of these weights is, up to an additive constant, the free-energy, and the discrete valued function defining the partition is called the collective variable. The algorithm falls into the general class of Wang–Landau type methods, and is a generalization of the original Self Healing Umbrella Sampling method in two ways: (i) the updating strategy leads to a larger penalization strength of already visited sets in order to escape more quickly from metastable states, and (ii) the target distribution is biased using only a fraction of the free-energy, in order to increase the effective sample size and reduce the variance of importance sampling estimators. We prove the convergence of the algorithm and analyze numerically its efficiency on a toy example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LICK INDICES AND SPECTRAL ENERGY DISTRIBUTION ANALYSIS BASED ON AN M31 STAR CLUSTER SAMPLE: COMPARISONS OF METHODS AND MODELS

Application of fitting techniques to obtain physical parameters—such as ages, metallicities, and α-element to iron ratios—of stellar populations is an important approach to understanding the nature of both galaxies and globular clusters (GCs). In fact, fitting methods based on different underlying models may yield different results and with varying precision. In this paper, we have selected 22 confirmed M31 GCs for which we do not have access to previously known spectroscopic metallicities. Most are located at approximately one degree (in projection) from the galactic center. We performed spectroscopic observations with the 6.5 m MMT telescope, equipped with its Red Channel Spectrograph. Lick/IDS absorption-line indices, radial velocities, ages, and metallicities were derived based on the EZ-Ages stellar population parameter calculator. We also applied full spectral fitting with the ULySS code to constrain the parameters of our sample star clusters. In addition, we performed χ{sub min}{sup 2} fitting of the clusters’ Lick/IDS indices with different models, including the Bruzual and Charlot models (adopting Chabrier or Salpeter stellar initial mass functions and 1994 or 2000 Padova stellar evolutionary tracks), the galev, and the Thomas et al. models. For comparison, we collected their UVBRIJK photometry from the Revised Bologna Catalogue (v.5) to obtain and fit the GCs’ spectral energy distributions (SEDs). Finally, we performed fits using a combination of Lick/IDS indices and SEDs. The latter results are more reliable and the associated error bars become significantly smaller than those resulting from either our Lick/IDS indices-only or our SED-only fits.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonparametric Multiparticle Set Methods for Interpreting Environmental Samples

Collection and analysis of environmental samples is commonly used by a range of stakeholders in nuclear safeguards and security contexts. While the ubiquity of samples and their transport in the environment allow regular collection, developing and demonstrating methods for analyzing these samples is difficult. In this work, an environmental sample consists of a set of one or more individual particles. Recent advances in reactor simulation have allowed us to generate data that are more representative of real-world environmental samples, enabling statistically defensible method development and testing. The most notable of these advances is a drastic increase in the number of material depletion regions, which allows our simulations to capture the variation in isotopic composition seen at length scales consistent with environmental samples. Traditional approaches for handling multiparticle samples treat each particle in the sample individually, estimating the quantity of interest (e.g., core-average burnup) resulting from measurement and analysis of signatures (e.g., nuclide assays) from each individual particle. Individual estimates are then averaged to generate a single estimate of the quantity of interest over the entire sample. In this presentation, we introduce two novel approaches for interpreting environmental samples that comprise of multiple particles: (1) the Quantile-Quantile Comparator, which uses a multivariate generalization of quantile-quantile plots for comparing unknown statistical distributions, and (2) the Set Transformer, an attention-based neural network module designed to model interactions among elements (particles) in the input set (sample). Statistically representative sampling cannot be guaranteed as samples are passively collected and are beholden to what particles are available in the environment. These new analysis methods for set-input problems are expected to be more robust than traditional approaches to issues of sampling bias where particles are not uniformly distributed throughout regions of interest, as well as generally outperform traditional approaches by jointly considering all elements in the set. We will present results comparing the performance of traditional single particle approaches and the novel Quantile-Quantile Comparator and Set Transformer for interpretation of simulated environmental samples.

Phathanapirom, Birdy↗

Uncertainty quantification tools for multiphase gas-solid flow simulations using MFIX

Computational fluid dynamics (CFD) has been widely studied and used in the scientific community and in the industry. Various models were proposed to solve problems in different areas. However, all models deviate from reality. Uncertainty quantification (UQ) process evaluates the overall uncertainties associated with the prediction of quantities of interest. In particular it studies the propagation of input uncertainties to the outputs of the models so that confidence intervals can be provided for the simulation results. In the present work, a non-intrusive quadrature-based uncertainty quantification (QBUQ) approach is proposed. The probability distribution function (PDF) of the system response can be then reconstructed using extended quadrature method of moments (EQMOM) and extended conditional quadrature method of moments (ECQMOM). The report first explains the theory of QBUQ approach, including methods to generate samples for problems with single or multiple uncertain input parameters, low order statistics, and required number of samples. Then methods for univariate PDF reconstruction (EQMOM) and multivariate PDF reconstruction (ECQMOM) are explained. The implementation of QBUQ approach into the open-source CFD code MFIX is discussed next. At last, QBUQ approach is demonstrated in several applications. The method is first applied to two examples: a developing flow in a channel with uncertain viscosity, and an oblique shock problem with uncertain upstream Mach number. The error in the prediction of the moment response is studied as a function of the number of samples, and the accuracy of the moments required to reconstruct the PDF of the system response is discussed. The QBUQ approach is then demonstrated by considering a bubbling fluidized bed as example application. The mean particle size is assumed to be the uncertain input parameter. The system is simulated with a standard two-fluid model with kinetic theory closures for the particulate phase implemented into MFIX. The effect of uncertainty on the disperse-phase volume fraction, on the phase velocities and on the pressure drop inside the fluidized bed are examined, and the reconstructed PDFs are provided for the three quantities studied. Then the approach is applied to a bubbling fluidized bed with two uncertain parameters, particle-particle and particle-wall restitution coefficients. Contour plots of the mean and standard deviation of solid volume fraction, solid phase velocities and gas pressure are provided. The PDFs of the response are reconstructed using EQMOM with appropriate kernel density functions. The simulation results are compared to experimental data provided by the 2013 NETL small-scale challenge problem. Lastly, the proposed procedure is demonstrated by considering a riser of a circulating fluidized bed as an example application. The mean particle size is considered to be the uncertain input parameter. Contour plots of the mean and standard deviation of solid volume fraction, solid phase velocities, and granular temperature are provided. Mean values and confidence intervals of the quantities of interest are compared to the experiment results. The univariate and bivariate PDF reconstructions of the system response are performed using EQMOM and ECQMOM.

97 MATHEMATICS AND COMPUTING↗

Sampling Microbial Dynamics in the Salish Sea Estuary: Evaluating Methods to Capture Cyanobacteria and Cyanophage

Introduction: Picocyanobacteria from the genera Prochlorococcus and Synechococcus thrive across the globe in aquatic environments, have relatively small genomes, and have growth dynamics regulated by both viral interactions and abiotic conditions, making them excellent model organisms for exploring host-pathogencoevolution. Methods: We developed and refined methods to sample and sequence cyanobacteria, cyanophages, and measured features of their abiotic environment. Results: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons. Our preferred final protocol from this exploratory effort included a combination of in-line and single vacuum flask filtrations, which reduced filtration processing time by over threefold in some cases compared to other tested methods, such as a fully in-line sequence or in-site filtrations. We successfully extracted an average of approximately 400–1200 ng for all filter fractions, with some variations between kits. Discussion: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons.

Salish Sea↗

The Effects of Different Lattice Codes on Results of Sensitivity and Uncertainty Analysis

According to the UAM ('Uncertainty Analysis in Modeling') benchmark, uncertainties in the LWR system calculations at all stages should be determined and quantified. As the neutronics calculations are prerequisite for the predictions of the reactor system, and the uncertainties introduced by the neutronics calculations would be propagated to the subsequent calculations, hence uncertainty analysis has been firstly focused on the neutronics phase to quantify the uncertainties of the reactor-physics predictions in UAM. For the lattice physics, the objective of uncertainty analysis is focused on uncertainty quantifications of the few-group constants; for the core physics, uncertainties of the core steady-state stand-alone neutronics calculations are focused on. Based on the previous researches, the nuclear-data uncertainty has been treated as one of the most significant source of uncertainty and received the most focus. In the previous works, the domestic code UNICORN has the capability of performing sensitivity analysis and uncertainty analysis using the direct numerical perturbation (DNP) method and statistical sampling (SS) method. In this paper, the capability of the UNICORN code has been improved. The domestic lattice code NECP-CACTI has been added in UNICORN to perform the lattice calculations, with DRAGON5.0 and NECP-CACTI available for lattice calculations. For DRAGON5.0 and NECP-CACTI, all the methods and technologies are shared in UNICORN. Therefore, the effects of different lattice codes on the results of sensitivity and uncertainty analysis have been researched and determined in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stochastic and deterministic methods for the calculation of small-sample reactivity experiments

Several calculations methods for the analysis of small-sample reactivity experiments are presented, as their main advantages and drawbacks. A numerical benchmark has been defined for this study consisting in a regular lattice of UO{sub 2} fuel pins, in which the central one is successively poisoned with isotopes of interest (actinides, absorbers, ...). A first method, based on a forward calculation ('eigenvalues difference method'), is presented, using either a deterministic or a stochastic calculation code. A first perturbative method studied is based on the 'Exact Perturbation Theory' (EPT) implemented in the deterministic code APOLLO2.8, and gives consistent results against forward calculations. A second perturbative method, the 'correlated sampling method', implemented in the stochastic calculation code TRIPOLI4.7 is tested. It should be use carefully as it is generally validated against small atomic density changes, but can be useful for conception studies. An 'hybrid method', based on the EPT formalism, using both Monte Carlo and deterministic results is tested, and shows reliable results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extraction Chromatographic Methods in the Sample Preparation Sequence for Thermal Ionization Mass Spectrometric Analysis of Plutonium Isotopes

A sample preparation sequence for actinide isotopic analysis by TIMS is described that includes column-based extraction chromatography as the first separation step, followed by anion exchange column separations. The sequence is designed to include a wet ashing step after the extraction chromatography to prevent any leached extractant or oxalic acid eluent reagents from interfering with subsequent separations, source preparation, or TIMS ionization. TEVA-resin and DGA-resin materials, containing extractants that consist only of C, N, O, and H atoms, were investigated for isolation of plutonium. Radiotracer level studies confirmed expected high yields from column-based separation procedures. Femtogram-level studies were carried out with TIMS detection, using multiple isotopic spikes through the separation sequence. Pu recoveries were 87% and 86% for TEVA- and DGA-resins separations respectively. The Pu recoveries from 400 {mu}L anion-exchange column separations were 89% and 93% for trial sequences incorporating TEVA and DGA-resin. Thus, a prior extraction chromatography step in the sequence did not interfere with the subsequent anion exchange separation when a simple wet ash step was carried out in between these column separations. The average measurement efficiency, for Pu, encompassing the chemical separation recoveries and the TIMS ionization efficiency, was 2.73 {+-} 0.77% (2-sigma) for the DGA-resin trials and 2.67 {+-} 0.54% for the TEVA-resin trials, compared to 3.41% and 2.37% (average 2.89%) for two spikes in the experimental set. These compare with an average measurement efficiency of 2.78 {+-} 1.70%, n = 33 from process benchmark analyses using Pu spikes processed through a sequence of oxalate precipitation, wet ash, iron hydroxide precipitation, and anion exchange column separations. We conclude that extraction chromatography can be a viable separation procedure as part of a multistep sequence for TIMS sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗