Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Preparation of large-particle-size monodisperse polystyrene latexes in microgravity

Three large-particle-size monodisperse latexes (3.44, 4.08, and 4.98 micron diameter) were prepared in an automated four-reactor apparatus on the third orbital mission of the 'Columbia' begun on March 22. Comparison with ground-based controls showed that the 4.98 micron-size flight sample was the more uniform; the uniformity at the other two sizes was about the same. The rates of polymerization in microgravity and on earth were the same within experimental error, demonstrating that radical-initiated vinyl addition polymerizations are unaffected by the weightless environment.

Vanderhoff, J. W.↗

Evolution of lunar soil grain-size and shape parameters

Substrates at the Apollo 15 and 16 sites were analyzed and showed essentially the same graphic mean, graphic standard deviation, and graphic skewness. The graphic kurtosis of Apollo 16 soils is slightly smaller than that of Apollo 15. In Apollo 15 soil samples, grain size and graphic standard deviation increase with depth, while the trend is reversed in Apollo 16 soil samples. Lower sphericity values for Apollo 15 samples coincide with concentrations of highly irregularly shaped glass particles. Two-dimensional sphericity of Apollo 15 samples is contoured as a function of particle size and depth below lunar surface. The results are consistent with an overall model for soil development in which samples closer to the surface are more mature in response to more prolonged reworking of meteorite impact.

Lindsay, J. F.↗

Stability of bulk Ba2YCu3O(7-x) in a variety of environments

Small bars of ceramic Ba2YCu3O(7-x) were fabricated and subjected to environments similar to those that might be encountered during some NASA missions. These conditions include ambient conditions, high humidity, vacuum, and high fluences of electrons and protrons. The normal state resistivity or critical current density (J sub c) were monitored during these tests to assess the stability of the material. When normal state resistivity is used as a criterion, the ambient stability of these samples was relatively good, exhibiting only a 2 percent degradation over a 3 month period. The humidity stability was shown to be very poor, and to be a steep function of temperature. Samples stored at 50 C for 40 min increased in normal state resistivity by four orders of magnitude. Kinetic analysis indicates that the degradation reaction is second order with water vapor concentration. It is suspected that humidity degradation also accounts for the ambient instability. The samples were stable to vacuum over a period of at least 3 months. Degradation of J sub c in a 1 MeV electron fluence of 9.7 x 10 to the 14th e(-)/sq cm was determined to be no more than about 2 percent. Degradation of J sub c in a 8.7 x 10 to the 14th p(+)/sq cm of 42 MeV protons was found to be grain size dependent. Samples with smaller grain size and initial J sub c of about 240 A/sq cm showed no degradation. while that with larger grain size and an initial J sub c of about 30 A/sq cm degraded to 37 percent of its original value.

Gaier, James R.↗

Design of a Biomass Scale Cubical Triaxial Tester

The bioenergy industry is dependent on predictable and reliable feedstock handling equipment. High profile failures in the industry demonstrate the need for better modeling tools for feedstock handling, specifically tools which can model the bulk flow of biomass feedstock materials in handling equipment such as hoppers or screw conveyors. Measurement of bulk material flow characteristics is a critical component to inform modeling tools. Following examples in the soils and pharmaceuticals industries, a Cubical Triaxial Tester (CTT) was selected as a critical component to study relationships between applied stress on a bulk sample and the resulting strain on the bulk material. In cooperation with The Pennsylvania State University, Forest Concepts designed a CTT specifically to measure bulk biomass flowability characteristics. Several mechanical design constraints were identified to ensure proper scaling and repeatability. Major design constraints included sample chamber size versus particle length, volumetric strain sensing accuracy, independent axial pressure control, and sample chamber handling. This report explains how major design constraints were determined.

09 BIOMASS FUELS↗

Differential scanning calorimetry of coal

Differential scanning calorimetry studies performed during the first year of this project demonstrated the occurrence of exothermic reactions associated with the production of volatile matter in or near the plastic region. The temperature and magnitude of the exothermic peak were observed to be strongly affected by the heating rate, sample mass and, to a lesser extent, by sample particle size. Thermal properties also were found to be influenced by oxidation of the coal sample due to weathering effects.

Gold, P. I.↗

Diagnostics development for spray characterization in complex turbulent flows

The present work reports a detailed investigation of air-liquid interaction in sprays along with particle number density and mass flux measurements in complex turbulent flows such as those present in gas turbines and rocket combustors. Data have been obtained for the characterization of sprays in complex flows which include detailed drop size and drop velocity distributions, size-velocity correlations, mass flux, and particle number density. Key factors affecting the measurement of the sample volume size are discussed in detail since an accurate estimation of it is essential to the particle number density and volume flux determined by the instrument. The discrimination of refraction and reflective scattering components and their influence on the measurements are also discussed. Data comparing the phase Doppler results to alternate methods of measuring number density and volume flux are also presented. These results showed agreement to within 15 percent in most cases for realistic flow configurations.

Bachalo, W. D.↗

Densification, microstructure, and mechanical properties of Mo–30W alloys fabricated from conditioned powders

Refractory alloys, such as molybdenum-based systems, are attracting growing interest for applications in extreme environments, such as in the nuclear and aerospace industries. Recent advances in sintering technologies, coupled with mechanical alloying, have enabled the tailored design of these alloys by leveraging powder characteristics to control final microstructures and mechanical properties. In this study, Mo-30W alloys were fabricated using electric field-assisted sintering (EFAS) from ball-milled powders with and without hydrogen treatment to investigate the influence of surface oxides on material properties and sintering behavior. The results revealed that samples processed from as-ball-milled powder contained a high density of oxides within the microstructure, whereas oxide presence was significantly reduced in samples fabricated from hydrogen-treated powders. Interestingly, the two powder types led to opposite trends in grain size distribution: samples from untreated powders exhibited grain refinement from sample periphery to the center, while samples from hydrogen-treated powders showed grain coarsening toward the center. This behavior is attributed to temperature gradients present during sintering due to electrical percolation pathway differences during Joule heating. The powder surface oxides may have influenced the temperature distribution and grain evolution. Microhardness profiles measured along both axial and thickness directions were consistent with the grain size distribution. Furthermore, oxide films on powder surfaces have delayed densification by hindering particle necking and atomic diffusion during sintering.

36 - MATERIALS SCIENCE↗

Size dependence of chondrule textural types

Chrondrule textural types were studied for size sorted chondrules from the ordinary chondrites Dhajala, Eston and Chainpur and the CM chondrite Murchison. Aliquot samples from size sorted Dhajala chondrules were studied for their oxygen isotopic composition and chondrules from Weston were studied for their precompaction irradiation records by nuclear track technique. Correlations between chondrule textural types and oxygen isotope or track data were identified. A distinct dependence of chondrule textural type on chondrule size was evident in the data for both Dhajala and Weston chondrules. No significant deviation was noticed in the abundance pattern of nonporphyritic chondrules within individual size fractions in the 200 to 800 micron size interval. Overabundance is found of nonporphyritic chondrules in the 100 to 200 micron size fraction of Murchison chondrules, the trend is not as distinct for Chainpur chondrules. Two hundred microns is suggested as the cutoff size below which radiative cooling is extremely efficient during the chondrule forming process. It is suggested that this offers a possibility for use of physical and chemical characteristics of small chondrules to constrain the temperature history during the chondrule formation process.

Goswami, J. N.↗

Research and development of a luminol-carbon monoxide flow system

Adaption of the luminol-carbon monoxide injection system to a flowing type system is reported. Analysis of actual wastewater samples was carried out and revealed that bacteria can be associated with particles greater than 10 microns in size in samples such as mixed liquor. Research into the luminol reactive oxidation state indicates that oxidized iron porphyrins, cytochrome-c in particular, produce more luminol chemiluminescence than the reduced form. Correlation exists between the extent of porphyrin oxidation and relative chemiluminescence. In addition, the porphyrin nucleus is apparently destroyed under the current chemiluminescent reaction conditions.

Thomas, R. R.↗

Results of Large-Scale Spacecraft Flammability Tests

For the first time, a large-scale fire was intentionally set inside a spacecraft while in orbit. Testing in low gravity aboard spacecraft had been limited to samples of modest size: for thin fuels the longest samples burned were around 15 cm in length and thick fuel samples have been even smaller. This is despite the fact that fire is a catastrophic hazard for spaceflight and the spread and growth of a fire, combined with its interactions with the vehicle cannot be expected to scale linearly. While every type of occupied structure on earth has been the subject of full scale fire testing, this had never been attempted in space owing to the complexity, cost, risk and absence of a safe location. Thus, there is a gap in knowledge of fire behavior in spacecraft. The recent utilization of large, unmanned, resupply craft has provided the needed capability: a habitable but unoccupied spacecraft in low earth orbit. One such vehicle was used to study the flame spread over a 94 x 40.6 cm thin charring solid (fiberglasscotton fabric). The sample was an order of magnitude larger than anything studied to date in microgravity and was of sufficient scale that it consumed 1.5 of the available oxygen. The experiment which is called Saffire consisted of two tests, forward or concurrent flame spread (with the direction of flow) and opposed flame spread (against the direction of flow). The average forced air speed was 20 cms. For the concurrent flame spread test, the flame size remained constrained after the ignition transient, which is not the case in 1-g. These results were qualitatively different from those on earth where an upward-spreading flame on a sample of this size accelerates and grows. In addition, a curious effect of the chamber size is noted. Compared to previous microgravity work in smaller tunnels, the flame in the larger tunnel spread more slowly, even for a wider sample. This is attributed to the effect of flow acceleration in the smaller tunnels as a result of hot gas expansion. These results clearly demonstrate the unique features of purely forced flow in microgravity on flame spread, the dependence of flame behavior on the scale of the experiment, and the importance of full-scale testing for spacecraft fire safety.

microgravity↗

Optimal spatial sampling techniques for ground truth data in microwave remote sensing of soil moisture

The paper examines optimal sampling techniques for obtaining accurate spatial averages of soil moisture, at various depths and for cell sizes in the range 2.5-40 acres, with a minimum number of samples. Both simple random sampling and stratified sampling procedures are used to reach a set of recommended sample sizes for each depth and for each cell size. Major conclusions from statistical sampling test results are that (1) the number of samples required decreases with increasing depth; (2) when the total number of samples cannot be prespecified or the moisture in only one single layer is of interest, then a simple random sample procedure should be used which is based on the observed mean and SD for data from a single field; (3) when the total number of samples can be prespecified and the objective is to measure the soil moisture profile with depth, then stratified random sampling based on optimal allocation should be used; and (4) decreasing the sensor resolution cell size leads to fairly large decreases in samples sizes with stratified sampling procedures, whereas only a moderate decrease is obtained in simple random sampling procedures.

Rao, R. G. S.↗

Efficient Probabilistic Visualization of Local Divergence of 2D Vector Fields with Independent Gaussian Uncertainty

This work focuses on visualizing uncertainty of local divergence of two-dimensional vector fields. Divergence is one of the fundamental attributes of fluid flows, as it can help domain scientists analyze potential positions of sources (positive divergence) and sinks (negative divergence) in the flow. However, uncertainty inherent in vector field data can lead to erroneous divergence computations, adversely impacting downstream analysis. While Monte Carlo (MC) sampling is a classical approach for estimating divergence uncertainty, it suffers from slow convergence and poor scalability with increasing data size and sample counts. Thus, we present a two-fold contribution that tackles the challenges of slow convergence and limited scalability of the MC approach. (1) We derive a closed-form approach for highly efficient and accurate uncertainty visualization of local divergence, assuming independently Gaussian-distributed vector uncertainties. (2) We further integrate our approach into Viskores, a platform-portable parallel library, to accelerate uncertainty visualization. In our results, we demonstrate significantly enhanced efficiency and accuracy of our serial analytical (speed-up up to 1946×) and parallel Viskores (speed-up up to 19698×) algorithms over the classical serial MC approach. We also demonstrate qualitative improvements of our probabilistic divergence visualizations over traditional mean-field visualization, which disregards uncertainty. We validate the accuracy and efficiency of our methods on wind forecast and ocean simulation datasets.

Ouermi, Timbwaoga [University of Utah]↗

Understanding the limitations and potential of micro tensile testing of tungsten and needs for crystal plasticity modelling

Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.

36 - MATERIALS SCIENCE↗

Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

36 MATERIALS SCIENCE↗

Nanophase Carbonates on Mars: Implications for Carbonate Formation and Habitability

Despite having an atmosphere composed primarily of CO2 and evidence for abundant water in the past, carbonate minerals have only been discovered in small amounts in martian dust [1], in outcrops of very limited extent [2, 3], in soils in the Northern Plains (the landing site of the 2007 Phoenix Mars Scout Mission) [4] and may have recently been detected in aeolian material and drilled and powdered sedimentary rock in Gale Crater (the Mars Science Laboratory [MSL] landing site) [5]. Thermal analysis of martian soils by instruments on Phoenix and MSL has demonstrated a release of CO2 at temperatures as low as 250-300 degC, much lower than the traditional decomposition temperatures of calcium or magnesium carbonates. Thermal decomposition temperature can depend on a number of factors such as instrument pressure and ramp rate, and sample particle size [6]. However, if the CO2 released at low temperatures is from carbonates, small particle size is the only effect that could have such a large impact on decomposition temperature, implying the presence of extremely fine-grained (i.e., "nanophase" or clay-sized) carbonates. We hypothesize that this lower temperature release is the signature of small particle-sized (clay-sized) carbonates formed by the weathering of primary minerals in dust or soils through interactions with atmospheric water and carbon dioxide and that this process may persist under current martian conditions. Preliminary work has shown that clay-sized carbonate grains can decompose at much lower temperatures than previously thought. The first work took carbonate, decomposed it to CaO, then flowed CO2 over these samples held at temperatures >100 degC to reform carbonates. Thermal analysis confirmed that carbonates were indeed formed and transmission electron microsopy was used to determine crystal sized were on the order of 10 nm. The next step used minerals such as diopside and wollastonite that were sealed in a glass tube with a CO2 and H2O source. After reacting these materials for a number of hours, thermal analysis demonstrated the formations of carbonates that decomposed at temperatures as low as 500 degC [7]. Further work is underway to carry out the weathering process under more Mars-like conditions (low pressure and low temperature) to determine if the carbonate decomposition temperature can be shifted to even lower temperatures, consistent with what has been detected by thermal analysis instruments on Mars.

Archer, P. Douglas, Jr.↗

Exact intervals and tests for median when one sample value possibly an outliner

Available are independent observations (continuous data) that are believed to be a random sample. Desired are distribution-free confidence intervals and significance tests for the population median. However, there is the possibility that either the smallest or the largest observation is an outlier. Then, use of a procedure for rejection of an outlying observation might seem appropriate. Such a procedure would consider that two alternative situations are possible and would select one of them. Either (1) the n observations are truly a random sample, or (2) an outlier exists and its removal leaves a random sample of size n-1. For either situation, confidence intervals and tests are desired for the median of the population yielding the random sample. Unfortunately, satisfactory rejection procedures of a distribution-free nature do not seem to be available. Moreover, all rejection procedures impose undesirable conditional effects on the observations, and also, can select the wrong one of the two above situations. It is found that two-sided intervals and tests based on two symmetrically located order statistics (not the largest and smallest) of the n observations have this property.

Keller, G. J.↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Stardust Sample Collection at Wild 2 and Its Preliminary Examination

The primary objective of STARDUST is to collect coma samples from 81P/Wild 2. This was made on January 2, 2004. Before the encounter three significant model predictions existed for the number and size of samples to be captured. Three investigations during the Wild 2 encounter (Dust Flux Monitor, Comet and Interstellar Dust Analyzer and Dynamic Science) made in situ measurements of the dust. Spectacular images were captured of the Wild 2 nucleus and dust jets. This abstract compares the model predictions with the in situ measurements and Wild 2 images and assesses the likely samples to be returned for analysis on January 15, 2006. To give some lead time for sample analysts to prepare for the analyses of the returned samples, the organization of the Preliminary Examination is presented.

Tsou, P.↗