Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Electric Vehicle Managed Charging: Forward-Looking Estimates of Bulk Power System Value

When and where electric vehicle charging occurs has significant implications for power systems supporting widespread electric vehicle deployment with high shares of wind and solar generation. Numerous studies have estimated the value of scheduling or otherwise managing electric vehicle charging in such power systems. This study improves on those earlier works by leveraging detailed simulation models for electric vehicle adoption, electric vehicle use, electric vehicle charging, and bulk power system operations; and linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This study closely analyzes electric vehicle managed charging (EVMC) performance along the dimensions of flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and participation rate, under the assumptions of ubiquitous chargers and all trips completed on time. The study is located in a passenger light-duty vehicle adoption scenario with 100% electric vehicle sales by 2035, and in an envisioned 2038 New England power system for which within-region generation is 84% clean.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The multiwavelength view of shocks in the fastest nova V1674 Her

Classical novae are shock-powered multiwavelength transients triggered by a thermonuclear runaway on an accreting white dwarf. V1674 Her is the fastest nova ever recorded (time to declined by two magnitudes is t 2 = 1.1 d) that challenges our understanding of shock formation in novae. We investigate the physical mechanisms behind nova emission from GeV γ-rays to cm-band radio using coordinated Fermi-LAT, NuSTAR, Swift, and VLA observations supported by optical photometry. Fermi-LAT detected short-lived (18 h) 0.1–100 GeV emission from V1674 Her that appeared 6 h after the eruption began; this was at a level of (1.6 ± 0.4) × 10 −6 photons cm −2 s −1 . Eleven days later, simultaneous NuSTAR and Swift X-ray observations revealed optically thin thermal plasma shock-heated to k $T$ shock = 4 keV. The lack of a detectable 6.7 keV Fe Kα emission suggests super-solar CNO abundances. The radio emission from V1674 Her was consistent with thermal emission at early times and synchrotron at late times. The radio spectrum steeply rising with frequency may be a result of either free-free absorption of synchrotron and thermal emission by unshocked outer regions of the nova shell or the Razin–Tsytovich effect attenuating synchrotron emission in dense plasma. The development of the shock inside the ejecta is unaffected by the extraordinarily rapid evolution and the intermediate polar host of this nova.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Engineering design of a kW-scale continuous reactor-heat exchanger for high temperature discharge of particle-based thermochemical energy storage

This study investigates the theoretical design parameters and thermal performance of a kW-scale continuous oxidation reactor for high temperature (~1000 °C) thermochemical energy storage (TCES) applications. The concept comprises a counter-current particle-based system that includes a reaction zone with a heat exchanger to extract the heat produced from the oxidation reaction. Both above and below the hot reactive volume are sensible heat recuperation zones to enable the feed and removal of particles and oxidizing gas near ambient temperature during steady state operation. Two operation types for the reaction zone are studied, a fluidized bed reactor (FBR) and a moving bed reactor (MBR). The results of the parametric analysis suggest that the MBR requires a smaller volume per kW of heat produced, achieving power densities in excess of 2500 kW/m3 compared to ~ 900 kW/m 3 in the FBR. Additionally, the MBR achieves between 0.71 and 0.99 oxidation conversions compared to between 0.23 and 0.38 conversions in the FBR with the same volumes and flowrates. However, the FBR has the potential to maintain a uniform reactor temperature which can produce heat transfer fluid (HTF) outlet temperatures as high as the reactor temperature, i.e., ~1000 °C, whereas the MBR produces variable reactor temperatures that can create overheating zones and low HTF outlet temperatures (< 800 °C) depending on the operating conditions selected. Future work should aim at understanding the coupled fluid dynamics, heat and mass transfer, and thermochemical reaction for any given combination of reactor volume and contacting patterns. Here, these studies should be complemented by experimental work on particle-gas TCES reactors.

25 ENERGY STORAGE↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Parallax-corrected VISST-derived pixel-level products from satellite GOES-16

The NASA Langley group led by William Smith produced GOES-16 satellite cloud retrievals over an approximate 10 by 10 degree region over the CACTI field campaign location. These retrievals are described here: https://www.arm.gov/capabilities/vaps/visst and are available for download here . They use algorithms historically called VISST that are now referred to as SatCORPS. More information can be found in Trepte et al. (2019), Minnis et al. (2021), and Yost et al. (2021). If using this dataset, please cite these references, the CACTI VISST dataset DOI found at the download link above, and this dataset’s DOI. The CACTI VISST pixel-level retrievals are on a 2 km spatial grid and available every 15 minutes (every 10 minutes late in the campaign), producing 21,765 files for the entire field campaign between October 2018 and April 2019. They are not corrected for parallax error, which is an offset in the actual geographical location of a cloud above the surface due to the satellite viewing the cloud partly from the side off nadir. This dataset applies a correction for parallax using the location relative to the satellite and the retrieved cloud top height above the surface, which allows the dataset to be geo-located with surface-based observations. The parallax correction for each location depends on the longitude, latitude and cloud top height above ground level (AGL) for that longitude and latitude in the original VISST files. The cloud top height AGL requires first computing the surface elevation at each VISST grid point. Data from the Advanced Spaceborne Thermal Emission and Reflection (ASTER) Global Digital Elevation Map Version 3 at 30-m resolution is projected onto the VISST grid using conservative coarsening (conserving surface elevation) in the xESMF Python package. The surface elevation is then subtracted from the VISST-retrieved cloud top height above mean sea level. These cloud top heights AGL are then combined with longitude and latitude to estimate the latitude and longitude corrections. Due to variability in cloud top height, the parallax shifts produce an irregular grid of values since higher cloud tops are shifted further than lower cloud tops. A ball tree-based neighbor search with Haversine distance is performed using the Python-based scikit-learn library to find the nearest VISST grid point to each parallax correction-shifted point. The data value of the shifted point is then assigned to that VISST grid point. In this manner, the irregular geographical shifts to correct for parallax are projected back to the rectilinear VISST grid. Because relatively higher clouds should obscure lower clouds, the variable values for the highest cloud top are preferentially chosen if two or more values are assigned to a grid point. The parallax correction should be viewed as an improved but still imperfect estimation of the cloud top locations, largely because the cloud top height is an imperfect retrieval. Please see the attached README document for further information. Users are encouraged to contact the authors with any additional questions.

54 ENVIRONMENTAL SCIENCES↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Automated point dendrometer, soil moisture and temperature, and meteorological variables datasets, Oct 2024 – Nov 2025, G.A. Pearson Natural Area, Flagstaff, AZ, USA

This data package includes parsed, cleaned, and calibrated data from 48 TOMST automated point dendrometers, 48 TOMST 15 cm soil moisture sensors, and 12 TOMST 30 cm soil moisture sensors. The point dendrometers were cleaned with the “dendRoAnalyst” package in RStudio. The soil sensors were cleaned and calibrated for volumetric water content (VWC) with the “myClim” package in RStudio using the soil texture of the site (sandy clay loam). Additionally, this data package also includes raw data from 2 METER weather stations. Dendrometers and soil sensors have both their sensor ID, as well as the ID for the specific tree they were instrumented on at the G.A. Pearson Natural Area (GPNA) site and their experimental group. The purpose of these data is to understand how ponderosa pine trees in restored (thinned and burned) vs. unrestored (no treatment) areas are responding to drought and seasonal precipitation. These data use radial growth and soil moisture data to answer the following question: how are active season length, growth on different time scales (weekly, monthly, seasonally, and annually), growth during dry periods and after precipitation events, and environmental and biological drivers of radial growth different between restored versus unrestored areas?

Air temperature↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

A double peak in the seasonality of California's photosynthesis as observed from space

Solar-induced chlorophyll fluorescence (SIF) has been shown to be a powerful proxy for photosynthesis and gross primary productivity (GPP). The recently launched TROPOspheric Monitoring Instrument (TROPOMI) features the required spectral resolution and signal-to-noise ratio to retrieve SIF from space. Here, we present a downscaling method to obtain 500 m spatial resolution SIF over California. We report daily values based on a 14 d window. TROPOMI SIF data show a strong correspondence with daily GPP estimates at AmeriFlux sites across multiple ecosystems in California. We find a linear relationship between SIF and GPP that is largely invariant across ecosystems with an intercept that is not significantly different from zero. Measurements of SIF from TROPOMI agree with MODerate Resolution Imaging Spectroradiometer (MODIS) vegetation indices – the normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and near-infrared reflectance of vegetation index (NIR$_v$) – at annual timescales but indicate different temporal dynamics at monthly and daily timescales. TROPOMI SIF data show a double peak in the seasonality of photosynthesis, a feature that is not present in the MODIS vegetation indices. The different seasonality in the vegetation indices may be due to a clear-sky bias in the vegetation indices, whereas previous work has shown SIF to have a low sensitivity to clouds and to detect the downregulation of photosynthesis even when plants appear green. We further decompose the spatiotemporal patterns in the SIF data based on land cover. The double peak in the seasonality of California's photosynthesis is due to two processes that are out of phase: grasses, chaparral, and oak savanna ecosystems show an April maximum, while evergreen forests peak in June. An empirical orthogonal function (EOF) analysis corroborates the phase offset and spatial patterns driving the double peak. The EOF analysis further indicates that two spatiotemporal patterns explain 84 % of the variability in the SIF data. Results shown here are promising for obtaining global GPP at sub-kilometer spatial scales and identifying the processes driving carbon uptake.

54 ENVIRONMENTAL SCIENCES↗

Facets control charge separation during photoelectrochemical water oxidation with strontium titanate (SrTiO 3 ) single crystals

The photocatalytic overall water splitting reaction provides a pathway to hydrogen fuel from sunlight. Photocatalysts must achieve the reaction without the application of an external bias, which requires an effective charge separation mechanism. Photolabeling studies and electrostatic simulations for the well-known CoOOH/Al:SrTiO 3 /Rh/Cr 2 O 3 photocatalyst suggest that charge separation is driven by work function differences at the (100) and (110) facets of SrTiO 3 , which are electron and hole selective, respectively. Here we use hydrogen annealed SrTiO 3–x single crystals to obtain the first quantitative assessment of the charge separation ability of the (100), or (110), or (111) facets during oxygen evolution. Under UV illumination (60 mW cm –2 ), the crystals exhibit variable water oxidation photocurrents (0.34, 0.82, 1.36 mA cm –2 at 1.23 V versus RHE) and photovoltage values of 1.40, 1.52 and 1.52 V for (100), (110), and (111) SrTiO 3–x , respectively. A surface photovoltage increase in that same order (0.31 V < 0.57 V < 0.67 V) is confirmed independently with vibrating Kelvin probe surface photovoltage spectroscopy (VKP-SPV) under 375 nm (1.91 mW cm –2 ) illumination. Mott Schottky measurements in aqueous K 3/4 [Fe(CN) 6 ] reveal facet-dependent flatband positions of –0.58, –0.71, and –0.74 V RHE for the (100), (110), and (111) crystals respectively. This confirms that the photoelectrochemical water oxidation performance of SrTiO 3–x crystals is controlled by the work function of each facet, which determines the electron transfer barrier height of the respective solid–liquid junctions. After correcting for differences in electron donor concentrations, barriers are found to increase in the order (100) < (111) < (110) and differ by as much as 0.16 eV, similar to an earlier prediction. Altogehter, these results explain the charge separation mechanism in SrTiO 3 photocatalysts and highlight the need for faceted semiconductor crystals as light absorbers in particle-based photocatalysts.

08 HYDROGEN↗

Modeling Photovoltaics Innovation and Deployment Dynamics

PV’s historically rapid cost reduction is exceptional among technologies. Further cost reductions could play a major role in increasing deployment in the future. To enable such cost reductions, new modeling frameworks are needed to understand the determinants of innovation in PV. In this project, we study the mechanisms driving PV module and system cost reductions, delving deeply into the specific technological innovations that have occurred in the past and the policies that encouraged them, and also opportunities for future cost reduction and widespread deployment. The project contributes new fundamental insight on the determinants of technological innovation by developing novel methods and insights that are generalizable and can therefore be applied to other technologies. The results will allow policy makers, engineers, and other stakeholders to better prioritize their efforts and investments in the future. The project is organized around four journal articles as described below. The first article [1] identifies ‘low-level’ (e.g. conversion efficiency improvement) and ‘high- level’ (e.g. R&D efforts) mechanisms of cost reduction in PV systems (Tasks 1-4). This work builds on a previous DOE grant, where we developed a framework for technological innovation leading to PV module cost reduction [2]. We advance a method to disentangle the contributions of physical (‘hardware’) and non-physical (‘soft technology’) changes. Our results uncover reasons behind the relatively slow evolution of soft technology and can inform new innovation approaches to these technologies. The second article [3] identifies specific engineering or institutional innovations that enabled the low-level mechanisms of cost reduction in PV module and balance-of-systems (BOS) (Tasks 5, 9, 10). We identify 85 innovations and connect them to the cost variables they affected. By developing an innovations typology, this study shows the differences between the types of innovations affecting PV modules and BOS components. Finally, by analyzing the industry origins of innovations, this study also finds that PV was well-positioned within an ecosystem of continuously advancing technologies. The third article [4] studies prospective cost reduction opportunities (Task 10). We explore how design approaches that emphasize standardization and automation, such as plug-and-play PV systems, can create cost reduction opportunities by reducing interactions and speeding up activities with high process costs. We show that this can lead to cost reduction in cost components with the most untapped opportunity for improvement such as installation labor, overhead, electrical BOS, and customer acquisition. The fourth article [5] analyzes how various policies supporting PV deployment and R&D contributed to PV’s cost improvement by enabling high-level mechanisms, specific innovations, and ultimately low-level mechanisms of cost reduction (Tasks 8, 13, 14). We investigate examples from different countries and connect these policies to quantifiable cost change mechanisms. Our study sheds light on the roles that different nations played over time, through a diverse set of policy approaches.

14 SOLAR ENERGY↗

Irrigation Infrastructure and Modernization – Setting a Baseline: Estimates of Irrigation Water Conveyance Infrastructure Extents and Composition and the Potential Water, Energy, and Economic Benefits of Modernization in the Western U.S.

In the Western United States (U.S.), water delivery for irrigation is still largely managed using century-old equipment and designs. Modernization of this vital water conveyance infrastructure, such as piping of earthen canals, is known to improve water availability and water quality for farmers, while saving energy and enabling new hydropower. However, there is sparse information about the extent of irrigation water delivery infrastructure, which makes it challenging to estimate the cost of upgrades at scale and the potential benefits of accelerating modernization work. This report estimates a variety of previously unquantified data points related to irrigation water delivery infrastructure in the Western U.S. to support stakeholders interested in nationwide modernization planning. The findings should be considered approximations, useful for understanding the scale, range, or variability of these indicators. Taken together, the findings of this report illustrate some of the challenges and opportunities involved in modernizing the agricultural water delivery infrastructure in the Western U.S. Accelerating the pace of modernization could strengthen the long-term resilience of U.S. food systems while providing significant economic, energy, water, and environmental benefits.

13 HYDRO ENERGY↗

Machine Learning Derived Dynamic Operating Reserve Requirements in High-Renewable Power Systems

Accurately forecasting wind and solar power output poses challenges for deeply decarbonized electricity systems. Grid operators must commit resources to provide reserves to ensure reliable operations in the face of forecast errors, a process which can increase fuel consumption and emissions. We apply neural network-based machine learning to expand the usefulness of median point forecast data by creating probabilistic distributions of short-term uncertainty in demand, wind, and solar forecasts that adapt to prevailing grid conditions. Machine learning derived estimates of forecast errors compare favorably to estimates based on incumbent methods. Reserves derived from machine learning are usually smaller than values derived using incumbent methods, which enables fuel savings during most hours. Machine learning reserves are generally larger than incumbent reserves during times of higher forecast error, potentially improving system reliability. Performance is tested using multi-stage production simulation modeling of the California Independent System Operator (CAISO) system. Machine learning reserves provide production cost and greenhouse gas (GHG) emission reductions of approximately 0.3% relative to historical 2019 requirements. Savings in the 2030 timeframe are highly dependent on battery storage capacity. At lower levels of battery capacity, savings of 0.4% from machine learning reserves are shown. Significant quantities of battery storage are expected to be added to meet California's resource adequacy needs and GHG reduction targets. Addition of these batteries saturate reserve needs and results in minimal within-hour balancing costs in 2030.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Deliverability Assessment of Distributed Energy Resources via Scenario-Based AC Optimal Power Flow

As electric grids decarbonize and distributed energy resources (DERs) become increasingly prevalent, interconnection assessments must evolve to reflect operational variability and control flexibility. This paper highlights key modeling limitations observed in practice and reviews approaches for modeling uncertainty. It then introduces a Probabilistic Deliverability Assessment (PDA) framework designed to complement and extend existing procedures. The framework integrates scenario-based AC optimal power flow (AC OPF), corrective dispatch, and optional multi-temporal constraints. Together, these form a structured methodology for quantifying DER utilization, deliverability, and reliability under uncertainty in load, generation, and topology. Outputs include interpretable metrics with confidence intervals that inform siting decisions and evaluate compliance with reliability thresholds across sampled operating conditions. A case study on Puerto Rico’s publicly available bulk power system model demonstrates the framework’s application using minimal input data, consistent with current interconnection practice. Across staged fossil generation retirements, the PDA identifies high-value DER sites and regions requiring additional reactive power support. Results are presented through mean dispatch signals, reliability metrics, and geospatial visualizations, demonstrating how the framework provides transparent, data-driven siting recommendations. The framework’s modular design supports incremental adoption within existing workflows, encouraging broader use of AC OPF in interconnection and planning contexts.

14 SOLAR ENERGY↗