Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Vector potential photoelectron microscopy

A new class of electron microscope has been developed for the chemical microanalysis of a wide range of real world samples using photoelectron spectroscopy. Highly structured, three-dimensional samples, such as fiber mats and fracture surfaces can be imaged, as well as insulators and magnetic materials. The new microscope uses the vector potential field from a solenoid magnet as a spatial reference for imaging. A prototype instrument has demonstrated imaging of uncoated silk, magnetic steel wool, and micron-sized single strand tungsten wires.

36 MATERIALS SCIENCE↗

Shocked Surface Stereo Imaging

Poster to be displayed at the upcoming SPIE job fair (August 28-Sept. 1) and recruiting trip to the Colorado School of Mines (Sept. 15). This poster will then also be used as a lab display at NMO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote Raman - laser induced breakdown spectroscopy (LIBS) geochemical investigation under Venus atmospheric conditions

The extreme Venus surface temperatures ({approx}740 K) and atmospheric pressures ({approx}93 atm) create a challenging environment for surface missions. Scientific investigations capable of Venus geochemical observations must be completed within hours of landing before the lander will be overcome by the harsh atmosphere. A combined remote Raman - LIBS (Laser Induced Breakdown Spectroscopy) instrument is capable of accomplishing the geochemical science goals without the risks associated with collecting samples and bringing them into the lander. Wiens et al. and Sharma et al. demonstrated that both analytical techniques can be integrated into a single instrument capable of planetary missions. The focus of this paper is to explore the capability to probe geologic samples with Raman - LIBS and demonstrate quantitative analysis under Venus surface conditions. Raman and LIBS are highly complementary analytical techniques capable of detecting both the mineralogical and geochemical composition of Venus surface materials. These techniques have the potential to profoundly increase our knowledge of the Venus surface composition, which is currently limited to geochemical data from Soviet Venera and VEGA landers that collectively suggest a surface composition that is primarily tholeiitic basaltic with some potentially more evolved compositions and, in some locations, K-rich trachyandesite. These landers were not equipped to probe the surface mineralogy as can be accomplished with Raman spectroscopy. Based on the observed compositional differences and recognizing the imprecise nature of the existing data, 15 samples were chosen to constitute a Venus-analog suite for this study, including five basalts, two each of andesites, dacites, and sulfates, and single samples of a foidite, trachyandesite, rhyolite, and basaltic trachyandesite under Venus conditions. LIBS data reduction involved generating a partial least squares (PLS) model with a subset of the rock powder standards to quantitatively determine the major elemental abundance of the remaining samples. PLS analysis suggests that the major element compositions can be determined with root mean square errors ca. 5% (absolute) for SiO{sub 2}, Al{sub 2}O{sub 3}, Fe{sub 2}O{sub 3}(total), MgO, and CaO, and ca. 2% or less for TiO{sub 2}, Cr{sub 2}O{sub 3}, MnO, K{sub 2}O, and Na{sub 2}O. Finally, the Raman experiments have been conducted under supercritical CO{sub 2} involving single-mineral and mixed-mineral samples containing talc, olivine, pyroxenes, feldspars, anhydrite, barite, and siderite. The Raman data have shown that the individual minerals can easily be identified individually or in mixtures.

36 MATERIALS SCIENCE↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic Spatial Gradients and Machine Learning-Based Classifiers for Explosion Monitoring (LDRD 218327)

This final report summarizes the work completed under the Laboratory Directed Research and Development (LDRD) project “Seismic Spatial Gradients as a Machine Learning-Based Classifier for Explosion Monitoring.” The overarching goal of the project was to explore the efficacy of using machine learning-based classification algorithms where the input data are the spatial gradient of the seismic wavefield collected at a single point on the Earth’s surface. The methods that I describe here are in direct contrast to conventional methods of seismic discrimination which typically rely on a spatially extended network of instruments and physics-based wavefield attributes such as, for example, the ratio between $\textit{P}$ and $\textit{S}$ waves. Rather, we use the spatial gradient of the seismic wavefield observed at a single point on the Earth’s surface and data processing approaches inspired by the machine learning community. We tested two algorithms, a neural network and a modified version of principal component analysis termed Spectrally Filtered Principal Component Analysis (SFPCA). To test these algorithms, we first conducted a series of numerical tests using synthetic data and then conducted a small-scale controlled field experiment. The tests using synthetic data showed that both algorithms had high success rates on gradiometric data, even when simulated noise was added to the signal. Furthermore, we found that using seismic spatial gradients increased the performance of our discrimination algorithms when compared to using just the traditional translational motion seismic data. The tests with field data also showed a high degree of discriminative success.

58 GEOSCIENCES↗

An experimental setup for the simultaneous measurement of thermoelectric power of two samples from 77 K to 500 K

We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔT increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

U.S. NO₂ trends (2005–2013): EPA air quality system (AQS) data versus improved observations from the Ozone Monitoring Instrument (OMI)

Emissions of nitrogen oxides (NO x ) and, subsequently, atmospheric levels of nitrogen dioxide (NO₂) have decreased over the U.S. due to a combination of environmental policies and technological change. Consequently, NO₂ levels have decreased by 30–40% in the last decade. We quantify NO₂ trends (2005–2013) over the U.S. using surface measurements from the U.S. Environmental Protection Agency (EPA) Air Quality System (AQS) and an improved tropospheric NO₂ vertical column density (VCD) data product from the Ozone Monitoring Instrument (OMI) on the Aura satellite.We demonstrate that the current OMI NO₂ algorithm is of sufficient maturity to allow a favorable correspondence of trends and variations in OMI and AQS data. Our trend model accounts for the non-linear dependence of NO₂ concentration on emissions associated with the seasonal variation of the chemical lifetime, including the change in the amplitude of the seasonal cycle associated with the significant change in NO x emissions that occurred over the last decade. The direct relationship between observations and emissions becomes more robust when one accounts for these non-linear dependencies. We improve the OMI NO₂ standard retrieval algorithm and, subsequently, the data product by using monthly vertical concentration profiles, a required algorithm input, from a high-resolution chemistry and transport model (CTM) simulation with varying emissions (2005-2013). The impact of neglecting the time-dependence of the profiles leads to errors in trend estimation, particularly in regions where emissions have changed substantially. For example, trends calculated from retrievals based on time-dependent profiles offer 18% more instances of significant trends and up to 15% larger total NO₂ reduction versus the results based on profiles for 2005. Using a CTM, we explore the theoretical relation of the trends estimated from NO₂ VCDs to those estimated from ground-level concentrations. The model-simulated trends in VCDs strongly correlate with those estimated from surface concentrations (r = 0.83, N = 355). We then explore the observed correspondence of trends estimated from OMI and AQS data. We find a significant, but slightly weaker, correspondence (i.e., r = 0.68, N = 208) than predicted by the model and discuss some of the important factors affecting the relationship, including known problems (e.g., NO z interferents) associated with the AQS data. This significant correspondence gives confidence in trend and surface concentration estimates from OMI VCDs for locations, such as the majority of the U.S. and globe, that are not covered by surface monitoring networks. Using our improved trend model and our enhanced OMI data product, we find that both OMI and AQS data show substantial downward trends from 2005 to 2013, with an average reduction of 38% for each over the U.S. The annual reduction rates inferred from OMI and AQS measurements are larger (–4.8 ± 1.9%/yr, –3.7 ± 1.5%/yr) from 2005 to 2008 than 2010 to 2013 (–1.2 ± 1.2%/yr, –2.1 ± 1.4%/yr). We quantify NO₂ trends for major U.S. cities and power plants; the latter suggest larger negative trend (–4.0 ± 1.5%/yr) between 2005 and 2008 and smaller or insignificant changes (–0.5 ± 1.2%/yr) during 2010-2013.

54 ENVIRONMENTAL SCIENCES↗

Status Update for the Canister Deposition Field Demonstration

This report updates the high-level test plan for evaluating surface deposition on three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUTECH Horizontal Modular Storage (NUHOMS) Advanced Horizontal Storage Modules (AHSMs) from Orano (formerly Transnuclear Inc.) and provides a description of the surface characterization activities that have been conducted to date. The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or requirements. The goal of the testing is to collect highly defensible and detailed dust deposition measurements from the surface of dry storage canisters in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the decay heat and thermal hydraulic environment. Test and heater design is supported by detailed computational fluid dynamics modeling. Instrumentation throughout the canister, storage module, and environment will provide extensive information about thermal-hydraulic behavior. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment. Functional testing of the finalized heater assemblies and test apparatus is set to begin in December 2022. The proposed delivery of the canisters to the host test site is June/July 2023, which is well ahead of when the AHSM installations would be completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simplified technique for remote monitoring of deflection in arch structures

This article describes a simplified technique to measure the vertical deflection of masonry arches in the presence of horizontal movements. One-dimensional laser Doppler vibrometer was utilized to measure the vertical displacement of the arch. A flat steel plate was mounted on the top surface of the arch crown to eliminate the measurement error due to the curvature of the arch. A reflective mirror was employed to guide the emitted laser beam normal to the surface of the steel plate. Vertical displacements recorded by laser Doppler vibrometer were compared to the readings of the mechanical dial gauge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of laser photothermal spectroscopy for standoff detection of trace explosive residues on surfaces

Laser photothermal methods of standoff detection of trace explosive residues on surfaces are considered. The analysis is restricted to the most promising methods: photoacoustic spectroscopy, deflection spectroscopy, and IR photothermal imaging of objects under resonant irradiation. Particular attention is paid to the choice of radiation sources and detectors. Comparative analysis of the existing standoff detection methods for explosive particles on the object surface is performed. Prospects of laser photothermal spectroscopy in this field are discussed. (review)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a dynamic biofilm imaging cell for white-light interferometric microscopy

In microbiology research there is a strong need for next generation imaging and sensing instrumentation that will enable minimally invasive and label-free investigation of soft, hydrated structures such as in bacterial biofilms. White light interferometry (WLI) can provide high resolution images of surface topology without the use of fluorescent labels but is not typically used to image biofilms because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ , especially in a non-destructive manner. In this report, we build on our prior description of static biofilm imaging and describe the design of a dynamic imaging flow cell that enables monitoring the thickness and topology of live biofilms over time using a WLI microscope. The microfluidic system is specifically designed to create a reflective interface on the surface of biofilms while minimizing disruption of fragile structures. The imaging cell was also designed to accommodate limitations imposed by the depth of focus of the microscope’s objective lens. Example images of live biofilm samples are shown in order to illustrate the ability of the flow cell and WLI instrument to 1) support bacterial growth and biofilm development, 2) image biofilm structure that reflects growth in flow conditions, and 3) monitor biofilm development over time non-destructively. In future work, the apparatus described here will enable surface metrology measurements (roughness, surface area, etc.) of biofilms and may be used to observe changes in biofilm structure in response to changes in environmental conditions (e.g., flow velocity, availability of nutrients, and presence of biocides). Furthermore, this development will open new opportunities for the use of WLI in bioimaging.

47 OTHER INSTRUMENTATION↗

A simple atomic force microscopy calibration method for direct measurement of surface energy on nanostructured surfaces covered with molecularly thin liquid films

A simple calibration method is described for the determination of surface energy by atomic force microscopy (AFM) pull-off force measurements on nanostructured surfaces covered with molecularly thin liquid films. The method is based on correlating pull-off forces measured in arbitrary units on a nanostructured surface with pull-off forces measured on macroscopically smooth dip-coated gauge surfaces with known surface energy. The method avoids the need for complex calibration of the AFM cantilever stiffness and the determination of the radius of curvature of the AFM tip. Both of the latter measurements are associated with indirect and less accurate measurements of surface energy based on various contact mechanics adhesion models.

36 MATERIALS SCIENCE↗

In-vacuum sensors for the beamline components of the ITER neutral beam test facility

Embedded sensors have been designed for installation on the components of the MITICA beamline, the prototype ITER neutral beam injector (Megavolt ITER Injector and Concept Advancement), to derive characteristics of the particle beam and to monitor the component conditions during operation for protection and thermal control. Along the beamline, the components interacting with the particle beam are the neutralizer, the residual ion dump, and the calorimeter. The design and the positioning of sensors on each component have been developed considering the expected beam-surface interaction including non-ideal and off-normal conditions. The arrangement of the following instrumentation is presented: thermal sensors, strain gages, electrostatic probes including secondary emission detectors, grounding shunt for electrical currents, and accelerometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AZIMUTHAL STRUCTURE OF THE Cyg X-2 X-RAY DUST HALO

There is little information concerning the azimuthal distribution of X-rays in dust-scattering halos. This paper describes a Chandra observation of the bright source Cyg X-2 designed specifically for this purpose. After measuring and subtracting Almost-Equal-To 10% instrument effects, we find the scattering halo to be rather uniform with possible fluctuations in the surface brightness of only 2%. Observations and data processing are discussed in detail. Some information about the dust distribution is derived.

79 ASTRONOMY AND ASTROPHYSICS↗