Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface modifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Interactions between fullerene derivatives and biological systems

Attention towards nanoparticles from the pharmaceutical and biomedical fields has significantly increased due to their attractive surface modification, high drug-loading, and improved pharmacokinetics. Fullerenes, an allotrope of carbon, stand out for their molecularly precise structure, potent radical-scavenging activity, photoactivatable reactive-oxygen species generation, and ability to definitively confine metal atoms and clusters. Accordingly, fullerene systems have been applied in various biological contexts, including increased and controlled drug delivery, antioxidative, anti-inflammatory, and photodynamic therapy, and magnetic resonance imaging. Ultimately, the pleiotropic activity of fullerenes, coupled with its precise structure and functionalization, can realize precise and tailorable medicines. Here, different from some excellent reviews focusing on the structure and chemistry of fullerene derivatives and their biomedical applications, this review highlights the interaction of fullerene materials with biological systems, with insights into their structural influence on their interactions with the cellular environment.

36 MATERIALS SCIENCE↗

Synergizing superwetting and architected electrodes for high-rate water splitting

Water splitting is one of the most promising technologies for generating green hydrogen. To meet industrial demand, it is essential to boost the operation current density to industrial levels, typically in the hundreds of mA cm -2 . However, operating at these high current densities presents significant challenges, with bubble formation being one of the most critical issues. Efficient bubble management is crucial as it directly impacts the performance and stability of the water splitting process. Superwetting electrodes, which can enhance aerophobicity, are particularly favorable for facilitating bubble detachment and transport. By reducing bubble contact time and minimizing the size of detached bubbles, these electrodes help prevent blockage and maintain high catalytic efficiency. Here, in this review, we aim to provide an overview of recent advancements in tackling bubble-related issues through the design and implementation of superwetting electrodes, including surface modification techniques and structural optimizations. We will also share our insights into the principles and mechanisms behind the design of superwetting electrodes, highlighting the key factors that influence their performance. Our review aims to guide future research directions and provides a solid foundation for developing more efficient and durable superwetting electrodes for high-rate water splitting.

36 MATERIALS SCIENCE↗

Biomimetic mineralization of positively charged silica nanoparticles templated by thermoresponsive protein micelles: applications to electrostatic assembly of hierarchical and composite superstructures

High information content building blocks offer a path toward the construction of precision materials by supporting the organization and reconfiguration of organic and inorganic components through engineered functions. Here, we combine thermoresponsiveness with biomimetic mineralization by fusing the Car9 silica-binding dodecapeptide to the C-terminus of the (VPGVG) 54 elastin-like polypeptide (ELP). Using small angle X-ray scattering, we show that the short Car9 cationic block is sufficient to promote the conversion of disordered unimers into 30 nm micelles comprising about 150 proteins, 5 °C above the transition temperature of the ELP. While both species catalyze self-limiting silica precipitation, micelles template the mineralization of highly monodisperse (62 nm) nanoparticles, while unimers yield larger polydisperse species. Strikingly, and unlike traditional synthetic silica, these particles exhibit a positive surface charge, likely due to cationic Car9 sidechains projecting from their surface. Capitalizing on the high monodispersity and positive charge of the micelle-templated products, we use smaller silica and gold particles bearing a native negative charge to create a variety of superstructures via electrostatic co-assembly. Furthermore, this simple biomimetic route to positively charged silica eliminates the need for multiple precursors or surface modifications and enables the rapid creation of single-material and composite architectures in which components of different sizes or compositions are well dispersed and integrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perturbation of nanoplastics on biomembranes: molecular insights from neutron scattering

Plastic waste is now pervasive in the environment, breaking down into microplastics and nanoplastics under many environmental conditions. These particles have been found in various ecosystems and even in human tissues, raising significant environmental and health concerns. In this study, we investigated the interaction of polystyrene nanoplastics, with and without surface modifications, on biomembrane structures using contrast-matching small-angle neutron scattering and neutron spin echo spectroscopy. The neutron contrast matching enabled the selective study of biomembranes in the presence of nanoplastics. Two model membranes were employed: a simple zwitterionic bilayer (i.e., dimyristoylphosphatidylcholine [DMPC]) and an Escherichia coli lipid extract as a bacterial membrane model. The results show profound membrane disruptions, including possible thinning, vesicle fragmentation, lipid monolayer formation, and inter-vesicle aggregation, with the more severe effects observed in DMPC membranes. Notably, E. coli membranes exhibited greater resilience, suggesting that natural membranes with diverse lipid compositions may reduce susceptibility to perturbation by extracellular nanoplastics. Here, these findings highlight potential risks posed by environmental nanoplastic particles to biological membranes, with insights into molecular-level interactions and the environmental toxicity of nanoplastics. This work provides a foundation for future studies into nanoplastic–biomembrane interactions and their broader implications for health and environment using neutrons.

Qian, Shuo [Oak Ridge National Laboratory (ORNL), ↗

rf-driven ion sources for industrial applications (invited) (abstract)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly developed combined rf ion-electron beam unit improves greatly the performance of the secondary ion mass spectrometry tool. (3) For neutron production, rf ion source is a major component of compact, high flux D-D, D-T, or T-T neutron generators. These neutron sources are now being employed in boron neutron capture therapy (BNCT) as well as in neutron imaging and material interrogation. (4) Large area rf-driven ion source will be used in an industrial design neutral beam diagnostic system for probing fusion plasmas. Such sources can be easily scaled to provide large ion beam current for future fusion reactor applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

rf plasma system as an atomic oxygen exposure facility

The materials of spacecraft external surfaces in low Earth orbit (LEO) are exposed to the various constituents of the space environment, including atomic oxygen (AO) and solar ultra violet (UV) radiation. Material degradation and erosion by LEO are simulated in ground laboratories using a variety of experimental facilities, each with their respective limitations. rf oxygen plasma is a simulation facility widely used for materials screening for LEO application. However, the complex plasma environment, which contains, in addition to the neutral oxygen atoms, excited species, electrons, and ions as well as vacuum ultraviolet (VUV) radiation, might lead to erroneous determination of materials reactivity with respect to LEO. This paper describes the development of a simple, low cost rf plasma system to produce a well-defined AO and VUV environment. The new system constrained the afterglow flow through two right-angle turns. The afterglow was characterized at three specific locations by (i) optical emission spectroscopy for assessment of electronically excited states, (ii) current measurements, and (iii) UV radiation measurements. Kapton registered samples were exposed at the three specific locations in the system and characterized by mass loss for etch rate evaluation, and atomic force microscopy for surface modification. It was found that there is a significant reduction in ionic species, excited species, and UV radiation as the afterglow advances through the right-angle turns. The reduction in charged particle flux is due to recombination within the afterglow as well as neutralization by colliding with the grounded metal chamber walls; similar decrease in UV radiation flux occurs through radiation absorption by the chamber walls. Finally, it is shown that the ground state AO is the dominant reactive specie of the plasma afterglow after passing through the two right-angle turns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Beam Measurements of a Dense Plasma Focus Device Using CR 39 Nuclear Track Detectors

The project is carried out using a small Mather type plasma focus device powered by a 15 kV, 30 {mu}F capacitor. The filling gas used is argon. The ion beam generated is investigated by both time resolved and time integrated methods. Investigation on the dynamic of the current sheath is also carried out in order to obtain an optimum condition for ion beam production. The angular distribution of the ion emission is measured at positions of 0 deg. (end-on), 45 deg. and 90 deg. (side-on) by using CR-39 nuclear track detectors. The divergence of the ion beam is also determined using these detectors. A biased ion collector is used for time resolved measurement of the ion beam. Time of flight technique is employed for the determination of the ion beam energy. Average ion beam energy obtained is about 180 keV. The ion beam produced can be used for applications such as material surface modification and ion implantation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser induced popcornlike conformational transition of nanodiamond as a nanoknife

Nanodiamond (ND) is surrounded by layers of graphite on its surface. This unique structure feature creates unusual fluorescence spectra, which can be used as an indicator to monitor its surface modification. Meanwhile, the impurity, nitroso (C-N=O) inside the ND can be photolyzed by two-photon absorption, releasing NO to facilitate the formation of a sp{sup 3} diamond structure in the core of ND and transforming it into a sp{sup 2} graphite structure. Such a conformational transition enlarges the size of ND from 8 to 90 nm, resulting in a popcornlike structure. This transition reaction may be useful as nanoknives in biomedical application.

36 MATERIALS SCIENCE↗

Diagnosis of high-intensity pulsed heavy ion beam generated by a novel magnetically insulated diode with gas puff plasma gun

Intense pulsed heavy ion beam is expected to be applied to materials processing including surface modification and ion implantation. For those applications, it is very important to generate high-purity ion beams with various ion species. For this purpose, we have developed a new type of a magnetically insulated ion diode with an active ion source of a gas puff plasma gun. When the ion diode was operated at a diode voltage of about 190 kV, a diode current of about 15 kA, and a pulse duration of about 100 ns, the ion beam with an ion current density of 54 A/cm{sup 2} was obtained at 50 mm downstream from the anode. By evaluating the ion species and the energy spectrum of the ion beam via a Thomson parabola spectrometer, it was confirmed that the ion beam consists of nitrogen ions (N{sup +} and N{sup 2+}) of energy of 100-400 keV and the proton impurities of energy of 90-200 keV. The purity of the beam was evaluated to be 94%. The high-purity pulsed nitrogen ion beam was successfully obtained by the developed ion diode system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4D Density Determination of NH Radicals in an MSE Microplasma Combining Planar Laser Induced Fluorescence and Cavity Ring-Down Spectroscopy

An application of microplasmas is surface modification under mild conditions and of small, well defined areas. For this, an understanding of the plasma composition is of importance. First results of our work on the production and detection of NH radicals in a capacitively coupled radio frequency (RF) microplasma are presented. A microstructured comb electrode was used to generate a glow discharge in a hydrogen/nitrogen gas mixture by applying 13.56 MHz RF voltage. The techniques of planar laser induced fluorescence (PLIF) and cavity ring-down spectroscopy (CRDS) are used for space and time resolved, quantitative detection of the NH radical in the plasma. The rotational temperature was determined to be 820 K and, the density 5.1x10{sup 12} cm{sup 3}. Also, time dependent behaviour of the NH production was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling and Simulation of the Advanced Plasma Source

Plasma ion assisted-deposition (PIAD) is a combination of conventional thermal evaporation deposition and plasma-beam surface modification; it serves as a well-established technology for the creation of high quality coatings on mirrors, lenses, and other optical devices. It is closely related to ion-assisted deposition to the extent that electrons preserve quasineutrality of the ion beam. This paper investigates the Advanced Plasma Source (APS), a plasma beam source employed for PIAD. A field enhanced glow discharge generates a radially expanding plasma flow with an ion energy of about 80-120 eV. Charge exchange collisions with the neutral background gas (pressure 0.1 Pa and below) produce a cold secondary plasma, which expands as well. A model is developed which describes the primary ions by a simplified Boltzmann equation, the secondary ions by the equations of continuity and momentum balance, and the electrons by the condition of Boltzmann equilibrium. Additionally, quasineutrality is assumed. The model can be reduced to a single nonlinear differential equation for the velocity of the secondary ions, which has several removable singularities and one essential singularity, identified as the Bohm singularity. Solving the model yields macroscopic plasma features, such as fluxes, densities, and the electrical field. An add-on Monte-Carlo simulation is employed to calculate the ion energy distribution function at the substrate. All results compare well to experiments conducted at a commercial APS system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron-beam direct processing on living cell membrane

We demonstrated a direct processing on a living Hep G2 cell membrane in conventional cultivation conditions using an electron beam. Electron beam-induced deposition from liquid precursor 3,4-ethylenedioxythiophene and ablation was performed on the living cells. The 2.5-10 keV electron beam which was irradiated through a 100-nm-thick SiN nanomembrane could induce a deposition pattern and a ablation on a living cell membrane. This electron beam direct processing can provide simple in-situ cell surface modification for an analytical method of living cell membrane dynamic.

60 APPLIED LIFE SCIENCES↗

Textured Nd2Fe14B flakes with enhanced coercivity

Morphology, structure, and magnetic properties of the [001] textured Nd2Fe14B nanocrystalline flakes prepared by surfactant-assisted high energy ball milling (HEBM) and subsequent annealing were studied. These flakes have a thickness of 80-200 nm, a length of 0.5-10 mu m, and an average grain size of 10-14nm. The addition of some amount of Dy, Nd70Cu30 alloy, and an appropriate post annealing increased the coercivity H-i(c) of the Nd2Fe14B flakes. iHc was 3.7, 4.3, and 5.7 kOe for the Nd15.5Fe78.5B6, Nd14Dy1.5Fe78.5B6 and 83.3wt.% Nd14Dy1.5Fe78.5B6+16.7 wt.% Nd70Cu30 flakes prepared by HEBM for 5 h in heptane with 20 wt.% oleylamine, respectively. After annealing at 450 degrees C for 0.5h, their iHc increased to 5.1, 6.2, and 7.0 kOe, respectively. Anisotropic magnetic behavior was found in all of the as-milled and annealed flakes. Both, the thickening of Nd-rich phase at grain boundaries via diffusion of Nd70Cu30 and the surface modification of the Nd2Fe14B flake could be the main reasons for the coercivity enhancement in the as-milled and annealed Nd70Cu30-added Nd2Fe14B flakes. (C) 2012 American Institute of Physics. [doi: 10.1063/1.3679425]

Cui, BZ↗

Performance enhancement of organic light-emitting diodes by chlorine plasma treatment of indium tin oxide

The characteristics of green phosphorescent organic light-emitting diodes (OLEDs) fabricated on ITO/glass substrates pretreated with low-energy O{sub 2} and Cl{sub 2} plasma were compared. At 20 mA/cm{sup 2}, the OLEDs with O{sub 2} and Cl{sub 2} plasma-treated indium tin oxide (ITO) had voltages of 9.6 and 7.6 eV, and brightness of 9580 and 12380 cd/m{sup 2}, respectively. At {approx}10{sup 4} cd/m{sup 2}, the latter had a 30% higher external quantum efficiency and a 74% higher power efficiency. Photoelectron spectroscopies revealed that Cl{sub 2} plasma treatment created stable In-Cl bonds and raised the work function of ITO by up to 0.9 eV. These results suggest that the better energy level alignment at the chlorinated ITO/organic interface enhances hole injection, leading to more efficient and more reliable operation of the OLEDs. The developed plasma chlorination process is very effective for surface modification of ITO and compatible with the fabrication of various organic electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Laser-induced breakdown spectroscopy of tantalum plasma

Laser Induced Breakdown spectroscopy (LIBS) of Tantalum (Ta) plasma has been investigated. For this purpose Q-switched Nd: YAG laser pulses (λ∼ 1064 nm, τ∼ 10 ns) of maximum pulse energy of 100 mJ have been employed as an ablation source. Ta targets were exposed under the ambient environment of various gases of Ar, mixture (CO{sub 2}: N{sub 2}: He), O{sub 2}, N{sub 2}, and He under various filling pressure. The emission spectrum of Ta is observed by using LIBS spectrometer. The emission intensity, excitation temperature, and electron number density of Ta plasma have been evaluated as a function of pressure for various gases. Our experimental results reveal that the optical emission intensity, the electron temperature and density are strongly dependent upon the nature and pressure of ambient environment. The SEM analysis of the ablated Ta target has also been carried out to explore the effect of ambient environment on the laser induced grown structures. The growth of grain like structures in case of molecular gases and cone-formation in case of inert gases is observed. The evaluated plasma parameters by LIBS analysis such as electron temperature and the electron density are well correlated with the surface modification of laser irradiated Ta revealed by SEM analysis.

36 MATERIALS SCIENCE↗

A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron

The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.

43 PARTICLE ACCELERATORS↗

Self-standing elastomeric composites based on lithium ferrites and their dielectric behavior

Lithium ferrite (LiFe{sub 5}O{sub 8}) is an attractive material for technological applications due to its physical properties, which are significantly dependent on the preparation method and raw materials. In this work, LiFe{sub 5}O{sub 8} crystallites were obtained by controlled heat-treatment process at 1100 °C, of a homogeneous mixture of Li{sub 2}O-Fe{sub 2}O{sub 3} powders, prepared by wet ball-milling and using lithium and iron nitrates as raw materials. The main goal was the preparation of a flexible and self-standing tick composite film by embedding lithium ferrite particles in a polymeric matrix, taking advantage of the good mechanical properties of the polymer and of the electrical and dielectric properties of the ferrite. The selected polymer matrix was styrene-b-isoprene-b-styrene copolymer. To prepare the composites, the lithium ferrite particles were chemically modified in order to functionalize their surface. To analyse the influence of the particles surface modification, different composites were made, with modified and unmodified particles. The structure of the obtained composites was studied by FTIR, XRD, TGA, and DSC techniques. The dielectric properties were analysed, in the frequency range between 10 Hz and 1 MHz and in function of temperature in the range between −73 °C and 127 °C. These properties were related with the structure and concentration of the particles in the matrix network. The composites with the modified particles present higher dielectric constant, maintaining values of loss tangent sufficiently low (<10{sup −2}) that can be considered interesting for technological applications.

36 MATERIALS SCIENCE↗