Search NASA⌕ Search

SEARCH · Search NASA

Results for “system testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Small-sized specimen design with the provision for high-frequency bending-fatigue testing

The testing and study of emerging materials—such as additively manufactured materials—demands for specimen designs that are cost effective and time saving. Here the design of a small-sized bending-fatigue test specimen for an ultrasonic fatigue testing system is reported in this paper. The design is optimized based on the finite element analysis and analytical-solution results to achieve the proper vibration shape and stress distribution. The proposed design is evaluated in the high- and very-high-cycle fatigue regimes under 20-kHz frequency. Both simulation and testing results confirm that the desirable vibration mode occurs and the specimen fails at the designated test (gauge) section, where the maximum stress exists. The stress–life (S–N) curve is obtained for Inconel alloy 718 and indicates an expected trend.

36 MATERIALS SCIENCE↗

Decoupled Modulation Control

The objective of this research work is to develop decoupled modulation control methods for damping inter-area oscillations with low frequencies, so the damping control can be more effective and easier to design with less interference among different oscillation modes in the power system. A signal-decoupling algorithm was developed that can enable separation of multiple oscillation frequency contents and extraction of a “pure” oscillation frequency mode that are fed into Power System Stabilizers (PSSs) as the modulation input signals. As a result, instead of introducing interferences between different oscillation modes from the traditional approaches, the output of the new PSS modulation control signal mainly affects only one oscillation mode of interest. The new decoupled modulation damping control algorithm has been successfully developed and tested on the standard IEEE 4-machine 2-area test system and a minniWECC system. The results are compared against traditional modulation controls, which demonstrates the validity and effectiveness of the newly-developed decoupled modulation damping control algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Accelerated ADMM for Distributed DC Optimal Power Flow

We propose a novel data-driven method to accelerate the convergence of Alternating Direction Method of Multipliers (ADMM) for solving distributed DC optimal power flow (DC-OPF) where lines are shared between independent network partitions. Using previous observations of ADMM trajectories for a given system under varying load, the method trains a recurrent neural network (RNN) to predict the converged values of dual and consensus variables. Given a new realization of system load, a small number of initial ADMM iterations is taken as input to infer the converged values and directly inject them into the iteration. We empirically demonstrate that the online injection of these values into the ADMM iteration accelerates convergence by a significant factor for partitioned 14-, 118- and 2848-bus test systems under differing load scenarios. The proposed method has several advantages: it maintains the security of private decision variables inherent in consensus ADMM; inference is fast and so may be used in online settings; RNN-generated predictions can dramatically improve time to convergence but, by construction, can never result in infeasible ADMM subproblems; it can be easily integrated into existing software implementations. While we focus on the ADMM formulation of distributed DC-OPF in this paper, the ideas presented are naturally extended to other distributed optimization problems.

alternating direction method of multipliers↗

Systematic Approach to Better Understanding Integration Costs: Preprint

When someone mentions integration costs, thoughts of the costs of integrating renewable generation into an existing system come to mind. We think about how variability and uncertainty can increase power system cycling costs as increasing amounts of wind or solar generation are incorporated into the generation mix. However, seldom do we think about what happens to system costs when new baseload generation is added to an existing system or when generation self-schedules. What happens when a highly flexible combined-cycle plant is added? Do system costs go up, or do they go down? Are other, non-cycling, maintenance costs impacted? In this paper we investigate six technologies and operating practices--including VG, baseload generation, generation mix, gas prices, self-scheduling, and fast-start generation--and how changes in these areas can impact a system's operating costs. This paper provides a working definition of integration costs and four components of variable costs. It describes the study approach and how a production cost modeling-based method was used to determine the cost effects, and, as a part of the study approach section, it describes the test system and data used for the comparisons. Finally, it presents the research findings, and, in closing, suggests three areas for future work.

17 WIND ENERGY↗

Nanoparticle Injection Technology for Remediating Leaks of CO 2 Storage Formation (Final Technical Report)

Leakage of a well can occur through the wellbore, the annulus between well tubing and steel casing, or on the outside of the casing. The overall goal of the project is to develop a new technology that can repair or reduce the leakage of wellbore. The new technology is based on simultaneously injecting nanoparticles electrochemically and removing some of the harmful ions in the system so the distressed cement materials can be densified and the corrosion risk of steel casing can be reduced. There were two objectives. One is the development of the injection technology for leakage repair and the other is the development of new numerical simulation models that can simulate and predict the performance of the new repair technology. An electro-migration testing unit and an in-house wellbore testing system were developed; healing agents with nanoparticles were selected, numerical models were developed to simulate the electro-migration technology, and the effectiveness of the new technology was evaluated.

42 ENGINEERING↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

Model Reduction for Fast Assessment of Grid Impact of High Penetration PV

A key challenge in properly analyzing the impact of solar photovoltaics (PV) during planning, interconnection and operation in the distribution grid is computational complexity. Such studies require the use of Quasi-Steady-Time-Series (QSTS) power flow to capture the complex interaction of PV with voltage regulating equipment and protection devices and a large number of scenario studies are needed to capture location specific constraints and uncertainties. In addition, a typical distribution feeder can have thousands of nodes and there can be thousands of such feeders in a given utility system. To solve this problem, a new and systematic method for distribution network reduction is proposed. The objective is to reduce the size of distribution systems by more than 80% while preserving the accuracy of power flow results. To this end, an extended Ward-equivalent method has been proposed to create an equivalent circuit. Moreover, load and PV aggregation based on the backward sweep method has been developed to further simplify the feeder. The proposed method is tested with a modified IEEE 123-node distribution test system. The simulation results demonstrate the high efficiency and accuracy of the proposed approach for distribution network reduction.

reduced order systems, load flow, load modeling, v↗

Multi-time Scale Coordination of Distributed Energy Resources in Isolated Power Systems

In isolated power systems, including microgrids, distributed assets, such as renewable energy resources (e.g. wind, solar) and energy storage, can be actively coordinated to reduce dependency on fossil fuel generation. The key challenge of such coordination arises from significant uncertainty and variability occurring at small time scales associated with increased penetration of renewables. Specifically, the problem is with ensuring economic and efficient utilization of DERs, while also meeting operational objectives such as adequate frequency performance. One possible solution is to reduce the time step at which tertiary controls are implemented and to ensure feedback and look-ahead capability are incorporated to handle variability and uncertainty. However, reducing the time step of tertiary controls necessitates investigating time-scale coupling with primary controls so as not to exacerbate system stability issues. In this paper, an optimal coordination (OC) strategy, which considers multiple time-scales, is proposed for isolated microgrid systems with a mix of DERs. This coordination strategy is based on an online moving horizon optimization approach. The effectiveness of the strategy was evaluated in terms of economics, technical performance, and computation time by varying key parameters that significantly impact performance. The illustrative example with realistic scenarios on a simulated isolated microgrid test system suggests that the proposed approach is generalizable towards designing multi-time scale optimal coordination strategies for isolated power systems.

Mayhorn, Ebony↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient Stability Assessment of Power Systems With Uncertain Renewable Generation: Preprint

The transient stability of a power system depends heavily on its operational state at the moment of a fault. In systems where the penetration of renewable generation is significant, the dispatch of the conventional fleet of synchronous generators is uncertain at the time of dynamic security analysis. Hence, the assessment of transient stability requires the solution of a system of nonlinear ordinary differential equations with unknown initial conditions and inputs. To this end, we set forth a computational framework that relies on Taylor polynomials, where variables are associated with the level of renewable generation. This paper describes the details of the method and illustrates its application on a nine-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of a Versatile Loading System for Anisotropic Material Property Characterization

Additive manufacturing, cold rolling, and other thermomechanical treatments on metals, especially HCP, can cause texture and oriented grain structures resulting in anisotropic mechanical properties. This can lead to macroscopic response that significantly deviates from isotropic assumptions which motivates studying mechanical properties in multiple directions. In addition, multiaxial loading and complex stress states overlapping the above mentioned material anisotropy can lead to unexpected outcomes. Idaho National Laboratory developed an advanced mechanical testing system to study a range of uniaxial to multiaxial stress states while measuring the anisotropic response bringing insight into the overlap between material properties and stress states. High-temperature capability and stress- or strain-controlled loading is available to enable a variety of experiment types and conditions to measure elastic, plastic, and viscoplastic properties. This poster presents the design and capabilities of this system with preliminary results highlighting the benefits of multiaxial loading and anisotropic analysis in an integrated system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

DOESC Closure Leak Test Assembly

This conceptual design report is for the DOESC Closure Leak Test Assembly, which satisfies a portion of the milestone "Preliminary Design Report for Remote Helium Leak Test System". This CDR is part of the Preliminary Design Report/Package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transmission system protection screening for integration of offshore wind power plants

This paper develops an efficient methodology for protection screening of large-scale transmission systems as part of the planning studies for the integration of offshore wind power plants into the power grid. This methodology avails to determine whether any upgrades are required to the protection system. The uncertainty is considered in form of variability of the power generation by offshore wind power plant. This paper uses the integration of a 1000 MW offshore wind power plant operating in Lake Erie into the FirstEnergy/PJM service territory as a case study. This study uses a realistic model of a 63,000-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Utility-Scale Power Tower Solar Systems: Performance Acceptance Test Guidelines

The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.

14 SOLAR ENERGY↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

The Dominant Influencer of Voltage Fluctuation (DIVF) for Power Distribution System

Variability in power generation at multiple consumer owned renewable energy sources can cause random voltage fluctuations, which may result in voltage violations at multiple nodes in a power distribution system. Traditional methods of voltage control are ineffective to address fast voltage variations. New dynamic methods of voltage control using end user devices can significantly benefit from the knowledge of the dominant influencer of voltage fluctuation (DIVF). This paper introduces information theoretic metrics to identify DIVF for every node in the power distribution system. A node can be DIVF due to its location in the distribution system and its capacity to generate and change its power. Use of traditional power flow algorithms to identify the DIVF is computationally complex which limits their use in real-time applications. In this work, information theoretic indicators of the DIVF are computed analytically in a computationally efficient manner, and their effectiveness to identify the DIVF is tested using the IEEE 69 node test system. From simulations, it is illustrated that differential entropy, Kullback-Leibler distance and Frechet distance are effective indicators of the DIVF and can successfully identify the most influential nodes providing the foundation for intelligent voltage control.

24 POWER TRANSMISSION AND DISTRIBUTION↗